| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AM520i Intrinsically Safe |
| Measurement Principle | Light Scattering |
| Safety Certification | IECEx / ATEX / CSA / UL Class I, Div 1 |
| Operating Temperature Range | 0 °C to +50 °C |
| Power Supply | 12 Vdc SELV, 2.5 A |
| Compliance | IEC 60079-0, IEC 60079-11, CSA C22.2 No. 258, UL 913, ANSI/ISA-12.12.01 |
| Software | TrakPro™ 5.0 Data Analysis Suite |
| Data Logging | Internal memory with time-stamped mass concentration (mg/m³) and particle count (#/cm³) records |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AM520i |
| Operating Principle | Optical Light Scattering (90° forward-scattered laser photometry) |
| Safety Rating | Intrinsically Safe (Class I, Division 1, Groups A–D |
| Measurement Range | 0.001–100 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Particle Size Selectivity | PM₁, PM₂.₅, PM₄ (Respirable), PM₅ (China Respirable Dust), PM₁₀, DPM (Diesel Particulate Matter, 0.8 µm aerodynamic diameter cut-point) |
| Battery Life | >20 hours continuous operation |
| Display | Full-color OLED screen |
| Data Logging | Internal flash memory with time-stamped mass concentration records |
| Compliance | Meets NIOSH BC 0500 and ISO 7706 for respirable dust sampling when used with appropriate cyclones |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SMPS-3938 |
| Size Range | 2.5–1000 nm |
| Resolution | Up to 167 channels per scan |
| Scan Time | <10 s |
| Concentration Range | Up to 1×10⁷ particles/cm³ |
| Compliance | ISO 15900:2009 |
| Detector Options | Butanol or Water-based CPCs |
| Neutralizer Options | Radioactive (⁸⁵Kr) or Non-radioactive (Bipolar Corona) |
| Control Interface | Integrated touchscreen, PC-free operation |
| Software | TSIGuard™ and Instrument Manager™ (PC required for full data analysis) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SoundPro™ SE-DL |
| Instrument Type | Handheld Noise Measurement Instrument |
| Accuracy Class | Class 1 or Class 2 (IEC 61672-1:2013, ANSI S1.4-2014) |
| Frequency Weighting | A, C, and Z (Linear) |
| Time Weighting | Fast, Slow, Impulse (IEC 61672) |
| Dynamic Range | 10 dB to 140 dB |
| Exchange Rate Options | 3 dB, 4 dB, 5 dB, or 6 dB |
| Data Logging Interval | 1 second to 60 minutes |
| Storage | Removable SD card |
| Connectivity | USB + RS-232 serial output |
| Display | Backlit graphical LCD with multilingual UI |
| Calibration | Internal reference tone + external acoustic calibrator compatible |
| Noise Dose Calculation | Enabled per OSHA 1910.95 & ISO 1999 |
| Real-time Octave Band Analysis | 1/1-octave (31.5 Hz – 8 kHz), conforming to IEC 61260-1:2014 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SOUNDPRO™ SE/DL Series |
| Frequency Range | 1 kHz (reference) |
| Measurement Range | 10–140 dB(A) selectable |
| Self-Noise Floor | ≤10 dB(A) (typical, per IEC 61672-1 Class 1) |
| Accuracy | ±1 dB (per ANSI S1.4 and IEC 61672-1) |
| Battery Life | >10 hours (alkaline, no backlight, basic SLM mode) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8636 |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Communication Protocol | MODBUS RTU (open standard) |
| Power Input | 120 VAC, output: 24 VAC |
| Sensor Type | Wall-mounted differential pressure transducer |
| Control Outputs | Dual analog (0–10 VDC or 4–20 mA) for supply & exhaust dampers, auxiliary outputs for heating/cooling control |
| Alarm Interface | Relay output with visual & audible alert |
| Enclosure Rating | NEMA 1 (indoor use) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–90 % RH (non-condensing) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8681 |
| Control Principle | Differential Pressure-Based Closed-Loop Airflow Balancing |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Communication Protocol | MODBUS RTU (Open Standard) |
| Power Input | 120 VAC → 24 VAC (included transformer) |
| Sensor Interface | Dedicated wall-mount differential pressure transducer (included) |
| Alarm Output | Relay + visual/audible indicators |
| Temperature Control Capability | Integrated supply air heating & volume modulation |
| Enclosure Type | Standalone DIN-rail or surface-mount controller |
| Software Integration | BMS-ready via RS-485 serial interface |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682 |
| Communication Protocol | Modbus RTU (Open Standard) |
| Power Input | 120 VAC to 24 VAC, 25 VA |
| Control Outputs | Relay Alarm + Analog/Digital Interface |
| Sensor Compatibility | External Room Pressure Transducer (Optional) |
| Compliance | NFPA 45-2000, ANSI Z9.5-2003 |
| Integration | BMS via Modbus or LonWorks (Optional) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8682-ST |
| Control Channels | Up to 5 independent duct systems |
| Pressure Sensing | Differential pressure transducer input |
| Output Interfaces | Analog (4–20 mA / 0–10 V), Relay alarms, MODBUS RTU (RS-485) |
| Power Supply | 120 VAC to 24 VAC transformer included (25 VA) |
| Enclosure | NEMA 1 indoor-rated |
| Compliance | CE, RoHS |
| Software Integration | Compatible with BMS via open MODBUS protocol |
| Alarm Logic | Adjustable delay to suppress transient false alarms |
| Local Interface | Backlit keypad and LCD display with password-protected configuration |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | VELOCICALC 9565 |
| Measurement Range | 0–20 m/s |
| Display | 5-parameter simultaneous readout |
| Data Storage | 26,500 points across 100 test groups |
| Probe Interface | Smart interchangeable probe system (vane, pitot tube, CO₂, VOC) |
| Pressure Range (Differential/Static) | ±15 in. H₂O (±3735 Pa) |
| Accuracy (Air Velocity, Pitot Mode) | ±2% of reading ±0.03 m/s at 10.16 m/s |
| Resolution (Velocity) | 0.01 m/s |
| Resolution (Pressure) | 0.001 in. H₂O (0.1 Pa) |
| Dimensions | 9.7 × 21.1 × 5.3 cm |
| Weight (with batteries) | 0.36 kg |
| Power | 4 × AA alkaline or optional AC adapter |
| Communication | Bluetooth v4.0 + USB |
| Compliance | Designed for HVAC commissioning per ASHRAE Guideline 1, ISO 16813, and ANSI/ASHRAE Standard 62.1 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565 |
| Compliance | NIST-traceable calibration certificate included |
| Probe Interface | Hot-swap modular probe system |
| Display | Backlit graphical LCD (up to 5 simultaneous parameters) |
| Data Logging | Internal memory supports up to 38.9 days at 1-minute sampling interval |
| Connectivity | USB and Bluetooth® v4.0 |
| Software | LogDat2™ and TrakPro™ Data Analysis Software included |
| Environmental Rating | IP54-rated housing |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –20–60 °C |
| Power | 4× AA alkaline or rechargeable NiMH batteries (typical life: 20 hrs with continuous use) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9535 / 9535-A / 9545 / 9545-A |
| Instrument Type | Hot-Wire Anemometer |
| Resolution | 0.01 m/s |
| Velocity Range | 0–30 m/s |
| Accuracy | ±3% of reading (for 0.15–30 m/s at 25°C) |
| Operating Temperature | –18°C to +93°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Temperature Compensation | ±0.03°C/°C deviation from 25°C |
| RH Compensation | ±0.2% RH/°C (including 1% hysteresis) |
| Data Storage | 12,700 samples + 100 test IDs |
| Included Software | LogDat2™ data download and analysis software |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565 / 9565A / 9565P / 9565X |
| Temperature Range (964/966/980/982 probes) | −10 to 60 °C, ±0.3 °C accuracy |
| Temperature Range (960/962 probes) | −18 to 93 °C, ±0.3 °C accuracy |
| Temperature Range (995 vane probe) | 0 to 60 °C, ±0.1 °C accuracy |
| Air Velocity Range (960/962) | 0–50 m/s, ±3% of reading or ±0.015 m/s (whichever is greater), 0.01 m/s resolution |
| Air Velocity Range (995 vane) | 0.25–30 m/s, ±1% of reading or ±0.02 m/s |
| Air Velocity Range (pitot tube) | 31.27–78.7 m/s, ±1.5% at 10.16 m/s |
| CO Range (982 probe) | 0–500 ppm, ±3% of reading or ±3 ppm |
| CO₂ Range (980/982 probes) | 0–5000 ppm, ±3% of reading or ±50 ppm |
| Relative Humidity Range | 0–95% RH, ±3% RH |
| Static/Differential Pressure Range | −28.0 to +28.0 mmHg (−3735 to +3735 Pa), ±1% of reading or ±0.01 mmHg |
| Barometric Pressure Range | 517.15–930.87 mmHg, ±2% of reading |
| Data Storage | 26,500 readings across 100 user-defined data groups |
| Sampling Interval | 1 s to 1 h |
| Operating Temperature | 5–45 °C |
| Dimensions | 9.7 × 21.1 × 5.3 cm |
| Weight (with batteries) | 0.36 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9565 / 9565-A / 9565-P / 9565-X |
| Temperature Range (964/966/980/982 probes) | −10 to 60 °C |
| Temperature Accuracy | ±0.3 °C (at 25 °C) |
| Temperature Resolution | 0.1 °C |
| Air Velocity Range (960/962 probes) | 0–50 m/s |
| Air Velocity Accuracy | ±3% of reading or ±0.015 m/s, whichever is greater |
| Air Velocity Resolution | 0.01 m/s |
| CO Range (982 probe) | 0–500 ppm |
| CO Accuracy | ±3% of reading or ±3 ppm, whichever is greater |
| CO₂ Range (980/982 probes) | 0–5000 ppm |
| CO₂ Accuracy | ±3% of reading or ±50 ppm, whichever is greater |
| CO₂ Resolution | 1 ppm |
| Relative Humidity Range | 0–95% RH |
| RH Accuracy | ±3% RH (at 25 °C) |
| RH Resolution | 0.1% RH |
| Pressure Range (Differential/Static) | −3735 to +3735 Pa |
| Pressure Accuracy | ±1% of reading or ±1 Pa |
| Pressure Resolution | 1 Pa |
| Data Storage Capacity | 26,500 data points across 100 user-defined groups |
| Operating Temperature | 5–45 °C |
| Dimensions | 9.7 × 21.1 × 5.3 cm |
| Weight (with batteries) | 0.36 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | VelociCalc™ 9600 / 9630 / 9650-NB |
| Air Velocity Range (Pitot Tube, 9630/9650-NB) | 1.27–78.7 m/s |
| Accuracy (at 10.16 m/s) | ±1.5% |
| Resolution | 0.01 m/s |
| Static/Differential Pressure Range | −3735 to +3735 Pa |
| Accuracy | ±1% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Barometric Pressure Range | 517.15–930.87 mmHg |
| Operating Temperature | 5–45 °C |
| Dimensions | 8.1 × 24.1 × 4.1 cm |
| Weight | 0.41 kg |
| Data Storage | 200 test IDs / 162,200 samples |
| Sampling Interval | 1 s – 1 h |
| Time Constants | 1, 5, 10, 20, 30, 60, 90 s |