TSI
Filter
Showing 31–60 of 105 results
| Brand | TSI |
|---|---|
| Country of Origin | USA |
| Model | 8535 |
| Application | Weatherproof Housing for DustTrak II 8530 and DRX 8533 Aerosol Monitors |
| Mounting | Standard 5/8"-11 Tripod Interface |
| Inlet | 360° Omnidirectional Sampling Port |
| Water Repellent Design | Integrated Hydrophobic Filter & Drainable Water Trap |
| Power Options | AC/DC Adapter Included |
| Thermal Management | Optional Insulation Kit Available |
| Compliance | Designed for Field Deployment in Accordance with EPA Reference Method Guidance for PM2.5/PM10 Ambient Monitoring (40 CFR Part 53), ASTM D6245, and ISO 12103-1 Test Dust Protocols |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533EP |
| Instrument Type | Real-Time Aerosol Mass Concentration and Size-Fractionated Monitor |
| Aerosol Concentration Range | 0.001–150 mg/m³ |
| Power Supply | Rechargeable 6600 mAh Lithium Battery + AC Adapter |
| Data Logging | Internal Memory with Programmable Interval (1 sec–1 hr) |
| Output Interfaces | Analog (0–5 V, 4–20 mA), USB, Alarm Relay |
| Compliance | NIOSH 0600 (PM1, PM2.5, PM10), ISO 7708, ASTM D6245, US EPA EQOA-PM Reference Method Equivalent (for screening) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533 / 8534 / 8533EP |
| Measurement Principle | Laser Light Scattering |
| Measured Parameters | PM₁, PM₂.₅, Respirable Suspended Particulates (RSP), PM₁₀, Total PM (<15 µm) |
| Measurement Range | 0.001–150 mg/m³ |
| Sampling Flow Rate | 3 L/min |
| Minimum Detectable Concentration | 1 µg/m³ |
| Flow Rate Stability | ±5% |
| Display | Color Touchscreen GUI |
| Data Output Interfaces | USB Device/Host, Ethernet, Analog Alarm Output |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533EP |
| Instrument Type | Real-time Aerosol Mass Concentration Monitor |
| Detection Principle | 90° Light Scattering (Laser Photometry) |
| Mass Concentration Range | 0.001–150 mg/m³ |
| Simultaneous Size-Fractionated Outputs | PM₁, PM₂.₅, Respirable (PM₄), PM₁₀, and Total PM (<15 µm) |
| Flow Rate | 3.0 L/min (±5% accuracy, internally controlled) |
| Optical System | Sheath-Air Isolated Laser Cavity |
| Display | 5.7″ VGA Color Touchscreen |
| Data Storage | 5 MB internal memory (>60,000 data points |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Time Constant | User-selectable (1–60 s) |
| Resolution | ±0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Zero Stability | ±0.002 mg/m³ over 24 h |
| Particle Size Range | 0.1–15 µm |
| Power | Rechargeable Li-ion battery (2.0 kg w/1 battery |
| Connectivity | USB, Ethernet (8533EP only), USB mass storage support |
| Analog Output | User-selectable 0–5 V or 2–20 mA |
| Alarm Output | Relay (non-latching MOSFET) or audible buzzer |
| Filter Holder | Replaceable 37 mm filter cassette (user-supplied) |
| Compliance | Designed for use in occupational health monitoring per OSHA, NIOSH, and ISO 7708 air sampling protocols |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | DustTrak II 8532 |
| Measurement Principle | 90° Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Mass Concentration Range | 0.001–150 mg/m³ |
| Resolution | ±0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Zero Stability | ±0.002 mg/m³ over 24 h (10-s averaging time) |
| Flow Rate | Factory-set at 3.0 L/min, user-adjustable from 1.40–3.0 L/min |
| Flow Accuracy | ±5% at factory-set point with internal flow control |
| Temperature Coefficient | +0.001 mg/m³/°C |
| Selectable Fractional Cuts | PM₁, PM₂.₅, PM₄, PM₁₀ (integrated sharp-cut cyclones) |
| Data Memory | 5 MB (>60,000 data points at 1-min interval |
| Recording Interval | 1 s–1 h, programmable |
| Time Constant | 1–60 s, user-selectable |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −20–60 °C |
| Dimensions (H×W×D) | 12.5 × 12.1 × 31.6 cm |
| Weight | 1.3 kg (bare), 1.5 kg (with Li-ion battery) |
| Display | 3.5″ VGA color touchscreen |
| Power | Rechargeable lithium-ion battery (internal/external charging) |
| Certifications | CPA certified (UK), CE compliant (EN 61326-1:2006 for immunity & emissions) |
| Alarm | Visual and audible (user-configurable setpoints, ±5% deadband) |
| Interface | USB port for data export |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8530 / 8532 / 8530EP |
| Measurement Principle | Light Scattering (90° Nephelometry) |
| Safety Rating | Intrinsically Safe (Class I, Division 1, Groups A–D) |
| Measurement Range | 0.001–400 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±10% of reading (traceable to NIST-traceable aerosol standards) |
| Particle Size Selectivity | PM₁, PM₂.₅, PM₁₀, and Respirable Dust (RSP) |
| Operating Temperature | −10 to 50 °C |
| Relative Humidity Limit | ≤95% RH (non-condensing) |
| Data Logging | Internal memory (up to 32,000 data points) |
| Power | Rechargeable Li-ion battery (up to 20 hrs), AC adapter, or external 12 V DC |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | DUSTTRAK™ II 8530 |
| Measurement Range | 0.001–400 mg/m³ |
| Resolution | Greater of 0.1% of reading or 0.001 mg/m³ |
| Sensor Principle | 90° Light Scattering |
| Flow Rate | 3.0 L/min (adjustable 1.4–3.0 L/min) |
| Particle Size Range | 0.1–15 µm |
| Data Memory | 5 MB (>60,000 points at 1-min interval) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Display | 5.7″ VGA color touchscreen |
| Communication | USB, Ethernet, USB flash drive export |
| Analog Output | User-selectable 0–5 V or 4–20 mA |
| Alarm Output | Relay and/or audible buzzer |
| Filter Holder | Replaceable 37 mm cassette |
| Compliance | EN 61326-1:2006 (EMC immunity & emissions) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | Edge 4 Plus Personal Noise Dosimeter |
| Instrument Type | Handheld Noise Dosimeter |
| Measurement Range | 70–140 dB |
| Accuracy Class | Class 2 (per IEC 61672-1:2013) |
| Battery Life | ≥40 hours (typical usage, display timeout enabled) |
| Microphone | ¼″ pre-polarized electret condenser, field-replaceable |
| Frequency Weightings | A, C, and Z |
| Exchange Rate Options | 3 dB, 4 dB, or 5 dB |
| Dose Counters | Dual independent dosimeters |
| Compliance Presets | OSHA 1910.95 & ACGIH TLV® preconfigured |
| Display | Full-color OLED screen |
| Connectivity | Bluetooth® 4.2 LE |
| App Compatibility | iOS 10.0+, Android 4.3+ |
| Enclosure | IP54-rated housing |
| Mass | 85 g (3 oz) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | EDGE 5 |
| Instrument Type | Handheld Noise Dosimeter |
| Measurement Range | 70–140 dB |
| Accuracy Class | Class 2 (per IEC 61252 & ANSI S1.25) |
| Battery Life | ≥40 hours |
| Certifications | ATEX, IECEx (Simtars), MSHA, CSA (US/Canada), UL |
| Ingress Protection | IP65 |
| Weight | 85 g |
| Dimensions | 89 × 53 × 19 mm |
| Microphone | 1/4″ pre-polarized electret condenser (field-replaceable) |
| Frequency Weightings | A, C, Z |
| Exchange Rates | 3 dB, 4 dB, or 5 dB (user-selectable per dosimeter channel) |
| Dose Channels | Three independent simultaneous dose calculations |
| Presets | OSHA 1910.95, ACGIH TLV® |
| Data Logging | L<sub>avg</sub>, L<sub>eq</sub>, L<sub>max</sub>, Peak, Overload events, Minute-interval energy averaging |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | EDGE |
| Measurement Range | 70 dB to 140 dB (A-weighted, linear RMS) |
| Frequency Range | 20 Hz to 8 kHz (±1.5 dB per IEC 61252:2017) |
| Self-Noise | <2.5 dB(A) |
| Accuracy | ±0.5 dB (per ANSI S1.25-1991 & IEC 61252:2017) |
| Operating Temperature | −10 °C to +50 °C |
| Ingress Protection | IP54 |
| Certifications | MSHA, ATEX Category 3G (SIRA), CSA C/US Class I Div 2, IECEx Simtars Ex ib IIC T4 Gb |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | Edge4+ |
| Weight | 85 g |
| Display | OLED color screen |
| Alarm | LED dose-exceedance indicator |
| Dose Groups | 2 independent configurable dose calculation sets |
| Power Management | Auto-display-off option for extended battery life |
| Compliance Standards Support | OSHA 1910.95, ISO 9612, ANSI S1.25, EU Directive 2003/10/EC |
| Data Storage | Internal logging with timestamped dose history |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8540 |
| Measurement Principle | Light Scattering (90° Nephelometry) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0.001–400 mg/m³ |
| Detection Limit | 1 µg/m³ |
| Sample Flow Rate | 3 L/min |
| Flow Stability | ±5% |
| Operating Temperature | −20 to +50 °C |
| Pump Lifetime | >10,000 hours |
| Certification | MCERTS Certified (PM₁₀ & PM₂.₅ variants available) |
| Data Management | Cloud-Based Platform with Remote Access and Alerting |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FHC50 / FHM10 |
| Cabinet Type | Single-Face Chemical Fume Hood |
| Construction Material | Polypropylene (PP) |
| Compliance Standards | ANSI Z9.5, NFPA 45, OSHA 1910.145, SEFA 1.5 |
| Communication Protocols | BACnet®, LonWorks®, Modbus™ |
| Alarm Outputs | Visual (LED), Audible (85 dB), Remote Relay |
| Display | Backlit LCD with Real-Time Surface Velocity, Temperature, and Status Indicators |
| Installation Options | Surface-Mount or Flush-Mount |
| Sensor Technology | Thermal Anemometry (FHM10), Dual-Sensor Fusion (FHC50: Sash Position + Face Velocity) |
| Actuation | Fast-Response Linear Actuator for VAV Valve Control |
| Environmental Compensation | Integrated Temperature and Barometric Pressure Compensation |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FHC50 |
| Communication Protocols | BACnet®, LonWorks®, Modbus™ |
| Alarm Types | Visual, Audible, Remote |
| Mounting Options | Surface or Flush Mount |
| Actuator Response | Fast-acting |
| Sensor Integration | Sash Position Sensor + Wall-Mounted Face Velocity Sensor |
| Control Method | Linear Venturi Valve or Pressure-Independent Air Valve |
| Compliance Support | ASHRAE 110, ANSI Z9.5, EN 14175 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FHC50 / FHM10 |
| Communication Protocols | BACnet®, LonWorks®, Modbus™ |
| Alarm Types | Visual, Audible, Remote |
| Installation Options | Surface-Mount or Flush-Mount |
| Sensor Integration | Sash Position, Face Velocity (via thermal anemometry), Static Pressure, Thermal Mass Flow |
| Compliance Support | ANSI/ASHRAE 110, EN 14175, ISO 10632, GLP-relevant audit trails via BMS integration |
| Output | 4–20 mA analog output (FHM10), relay outputs, digital status reporting |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | FMS |
| Instrument Type | Online Continuous Monitoring System |
| Flow Capability | High-Flow Sampling Support |
| Regulatory Compliance | FDA 21 CFR Part 11, EU GMP Annex 1, ISO 14644, GAMP® 5 |
| Database | Redundant SQL-based (Microsoft SQL Server / MySQL compatible) |
| Communication Protocols | Modbus RTU/ASCII, 4–20 mA, Digital I/O, PoE, Ethernet |
| Output Control | Vacuum pump trigger, fixed-point air sampler activation |
| Data Export | CSV, PDF, scheduled/real-time reports |
| Security | Role-based access, password aging, full audit trail, electronic signatures |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | M32-01 |
| Application | Laboratory Environmental Monitoring |
| Sampling Ports | 32 |
| Compatible Flow Rate | 28.3 L/min (1 CFM) |
| Minimum Detectable Particle Size | 100 nm |
| Software Control | FMS 5 |
| Maximum Tubing Length per Port | 38.1 m |
| Self-Cleaning Cycle | Enabled |
| Vacuum Flow Monitoring | Integrated Pressure Sensors |
| Warranty | 2 Years |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 3076 |
| Aerosol Generation Principle | Collison-type nebulization |
| Nominal Aerosol Flow Rate | 3.0 L/min |
| Maximum Aerosol Concentration | ≥1 × 10⁷ particles/cm³ |
| Particle Size Range | 0.01–2 µm (multimodal, adjustable via solution formulation and operational parameters) |
| Aerosol Precursors | PSL, DOP, silicone oil, NaCl, sucrose, and other soluble or colloidal suspensions |
| Construction | All-stainless-steel nozzle assembly, borosilicate glass reservoir, integrated low-noise diaphragm compressor |
| Compliance | Designed for ISO 14644-3, ISO 21501-4, ASTM F2894, and EN 1822 test protocols |
| Brand | TSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3088 |
| Price Range | USD 13,500 – 27,000 (est.) |
| Operating Principle | Controlled Corona Discharge Neutralization |
| Safety Rating | Non-Explosive (Class I, Division 2 compliant per ANSI/ISA-12.12.01) |
| Measurement Range | N/A (Neutralization device — no direct concentration measurement) |
| Resolution | N/A |
| Accuracy | N/A |
| Relative Error | N/A |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 3330-OPS |
| Principle | Optical Single-Particle Detection (Light Scattering) |
| Sample Flow Rate | 1.0 L/min ±5% |
| Particle Size Range | 0.3–10 μm |
| Counting Concentration Range | 3,000,000 particles/L |
| Size Channels | 16 |
| Mass Concentration Range | 0.001–275,000 µg/m³ |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 4046 |
| Flow Range | 2.5–300 L/min |
| Accuracy | ±2% of reading or ±0.05 STD L/min (whichever is greater) |
| Display | Real-time volumetric flow (temperature- and pressure-compensated) |
| Response Time | 4 ms |
| Dimensions | 183 × 64 × 53 mm |
| Weight | 0.5 kg |
| Power | 7.5 VDC ±1.5 V, peak current 300 mA |
| Warm-up Time | 1 min |
| Calibration | NIST-traceable certificate included |
| Compliance | NIOSH-approved primary calibration reference instrument |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 4146 |
| Flow Range | 0.01–20 L/min |
| Accuracy | ±2% of reading or ±0.05 STD L/min (whichever is greater) |
| Response Time | 4 ms |
| Dimensions | 127 mm × 50 mm × 32 mm |
| Weight | 0.8 kg |
| Power Supply | 7.5 VDC ±1.5 V, peak current 300 mA |
| Warm-up Time | 1 min |
| Temperature Compensation | Yes |
| Pressure Correction | Yes |
| NIST-Traceable Calibration Certificate | Included |
| NIOSH-Approved Primary Reference Standard | Yes |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 4146 / 4046 |
| Calibration Level | Primary (NIOSH-Recognized) |
| Flow Measurement Principle | Critical Orifice (Restriction-Type) |
| Accuracy | ±2% of reading |
| Certifications | NIST-traceable calibration certificate included |
| Power Source | Rechargeable battery |
| Portability | Handheld, lightweight design for field use |
| Compliance | Recognized as a Primary Reference Instrument by NIOSH for personal sampling pump calibration |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5725 |
| Velocity Range | 0.25–30 m/s |
| Accuracy | ±1% of reading or ±0.02 m/s (whichever is greater) |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Duct Area Range | 0–16 m² |
| Data Storage | 12,700 readings across 100 data groups |
| Sampling Interval | 1 s – 1 h |
| Time Constant | User-adjustable |
| Operating Temperature | 5–45 °C |
| Probe Operating Temperature | 0–60 °C |
| Storage Temperature | −20–60 °C |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with batteries) | 270 g |
| Power | 4 × AA alkaline batteries |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5815, 5825 |
| Pressure Range | −3735 to +3735 Pa (−28.0 to +28.0 mmHg) |
| Pressure Resolution | 0.1 Pa, 0.001 mmHg |
| Pressure Accuracy | ±1% of reading, ±0.01 mmHg, or ±1 Pa (whichever is greater) |
| Air Velocity Range (with Pitot Tube) | 1.27–78.7 m/s |
| Air Velocity Resolution | 0.1 m/s |
| Air Velocity Accuracy | ±1.5% at 10.16 m/s |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Data Storage Capacity | 12,700 readings across up to 100 data sets |
| Sampling Interval | 1 s to 1 h |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with batteries) | 0.27 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Volume Flow Calculation | Supported via user-defined duct dimensions (1–635 mm, 0.1 mm increments) and programmable K-factor |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7415, 7425 |
| Temperature Sensor | Thermistor |
| Temperature Range | 0–60°C |
| Temperature Accuracy | ±0.6°C at 25°C (with ±0.03°C/°C thermal drift compensation) |
| Temperature Resolution | 0.1°C |
| Relative Humidity Sensor | Thin-film Capacitive |
| RH Range | 5–95% RH |
| RH Accuracy | ±3% RH at 25°C (with ±0.2% RH/°C thermal drift compensation |
| RH Resolution | 0.1% RH |
| Operating Temperature (Instrument) | 5–45°C |
| Operating Temperature (Probe) | −10–60°C |
| Storage Temperature | −20–60°C |
| Data Memory Capacity | 12,700 measurements across 100 data sets |
| Logging Interval | 1 s to 1 h |
| Time Constant | User-configurable |
| Dimensions (Instrument) | 8.4 × 17.8 × 4.4 cm |
| Probe Dimensions | 17.8 cm length × 1.9 cm diameter |
| Weight | 270 g |
| Power Supply | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7515 |
| Instrument Type | Portable |
| Resolution | 1 ppm |
| Response Time | 20 s |
| Measurement Range | 0–5000 ppm |
| Accuracy | ±3.0% of reading or ±50 ppm (whichever is greater) |
| Power Supply | 4 × AA batteries |
| Operating Temperature | -20 to 60 °C |
| Dimensions (main unit) | 8.4 × 17.8 × 4.4 cm |
| Probe Dimensions | 7 cm length × 1.9 cm diameter |
| Sensor Technology | Dual-wavelength NDIR (Non-Dispersive Infrared) |
| Certification | CPA Pattern Approval Certificate (P.R. China) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7525 |
| CO₂ Sensor Type | Dual-Wavelength NDIR |
| CO₂ Range | 0–5000 ppm |
| CO₂ Accuracy | ±3.0% of reading or ±50 ppm (whichever is greater) |
| CO₂ Resolution | 1 ppm |
| CO₂ Response Time | 20 s (t₉₀) |
| Temperature Sensor | Thermistor |
| Temp Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Temp Response Time | 30 s (at 2 m/s air velocity, t₉₀) |
| RH Sensor | Thin-Film Capacitive |
| RH Range | 5–95 %RH |
| RH Accuracy | ±3.0 %RH |
| RH Resolution | 0.1 %RH |
| RH Response Time | 20 s (t₆₃) |
| Outdoor Air Percentage Calculation | 0–100 % |
| Resolution | 0.1 % |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Dimensions (Instrument) | 8.4 × 17.8 × 4.4 cm |
| Probe Length | 17.8 cm |
| Probe Diameter | 1.9 cm |
| Time Constants | 1, 5, 10, 20, 30 s |
| Logging Interval | 1 s to 1 hr (user-selectable) |
| Data Storage Capacity | Up to 30,300 records |
| Weight (with batteries) | 0.27 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7545 |
| Measured Parameters | CO₂, CO, Temperature, Relative Humidity |
| Derived Parameters | Dew Point Temperature, Wet-Bulb Temperature, Outdoor Air Fraction (calculated) |
| Sensor Technology | NDIR (CO₂), Electrochemical (CO), Capacitive (RH), Thermistor (Temperature) |
| Data Logging | Internal memory with timestamped records |
| Interface | USB for data download via TSI LogDat2™ software |
| Compliance | Designed to support ASHRAE 62.1, ISO 16814, and EN 13779 indoor air quality assessment protocols |