Cell Analysis
Filter
Showing 181–210 of 367 results
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HIC-1.2 |
| Compatible Instruments | HI-7, HI-9 Micromanipulators |
| Outer Diameter Compatibility | 1.2 mm |
| Seal Material | Silicone Rubber |
| Dimensions (Cap) | 20 × 5 × 5 mm |
| Weight | 1 g |
| Package Includes | Single cap with integrated silicone gasket (HI01PK01) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | HIC-1.5 |
| Compatible Instruments | HI-7, HI-9 Micromanipulators |
| Cap Outer Diameter | 1.5 mm |
| Silicone Gasket Included | HI01PK04 (20 × 5 × 5 mm, 1 g) |
| Brand | Hiscore |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region Classification | Domestic (China) |
| Model | EOS Series |
| Pricing | Available Upon Request |
| Brand | Hiscore |
|---|---|
| Origin | Beijing, China |
| Model | Halocounter |
| Detection Time | 3 s |
| Cell Concentration Range | 1×10³–3×10⁷ cells/mL |
| Sample Volume | 5–40 µL |
| Throughput | 2–8 samples per run |
| Detectable Cell Diameter | 0.8–400 µm |
| Regulatory Compliance Option | FDA 21 CFR Part 11 Audit Trail (Software Module) |
| Brand | HOOKE INSTRUMENTS |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PRECI SCS |
| Type | Fully Automated |
| Pricing | Upon Request |
| Brand | Huawei (Dalian Huawei) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HW-HURRICANE |
| Pricing | Upon Request |
| Brand | Huawei (Dalian Huawei) |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HW-SeaBreeze Series II |
| Price Range | USD $135,000 – $405,000 |
| Automation Level | Fully Automated |
| Sample Volume | 1–1001 nL |
| Cell Handling Capacity | 1–10,000 cells per run |
| Temperature Control Range | 0–100 °C |
| Maximum Culture Volume per Chip | 10 µL |
| Gas Pressure Control Range | 0–5 bar |
| Key | Brand: NARISHIGE |
|---|---|
| Origin | Japan |
| Model | IM-H2 |
| Application | Dedicated mounting system for IM-9C pneumatic microinjector with 1 mm capillary pipettes |
| Includes | HI-7 micromanipulator mount, CT-1 PTFE tubing (1 m), Type III connector, HI01PK01 silicone rubber gasket (2.5 mm ID, pack of 10) |
| Brand | Instec |
|---|---|
| Origin | USA |
| Model | HCS60 |
| Temperature Range | 5 °C to 60 °C (optional up to 95 °C) |
| Temperature Resolution | 0.01 °C |
| Temperature Stability | ±0.1 °C at 37 °C |
| Max. Heating Rate | +50 °C/min at 37 °C |
| Max. Cooling Rate | −50 °C/min at 37 °C |
| Min. Heating/Cooling Rate | ±0.1 °C/hour |
| Control Method | PID with Variable Bipolar DC Control |
| Sensor | 100 Ω Platinum RTD |
| Working Distance | 5.6 mm (with optional insert) |
| Condenser Distance | 19.1 mm |
| Sample Area | 35 mm diameter |
| Chamber Height | 19 mm |
| Viewing Aperture | 13 mm (with insert), 20 mm (without insert) |
| Brand | iotaSciences |
|---|---|
| Origin | United Kingdom |
| Model | isoCell |
| Type | Fully Automated |
| Sorting Throughput | 256 cells per 10 minutes |
| Total Sortable Cells per Run | 256 |
| Sample Processing Capacity | 256 single cells per cycle |
| Programmable Protocols | 1 |
| Sample Preparation | Direct sorting from untreated single-cell suspension without pre-enrichment or staining |
| Brand | iotaSciences |
|---|---|
| Origin | United Kingdom |
| Model | isoPick |
| Type | Fully Automated |
| Sorting Speed | High-throughput |
| Core Technology | GRID Microfluidic Patterning (Patent WO2019197373A1) |
| Chamber Density | 256 single-cell cavities per 6 cm dish |
| Dispense Volume | Nanoliter-scale precision |
| Imaging | Integrated high-resolution optical microscopy |
| Sample Transfer Compatibility | Direct transfer to PCR tubes or 96-well plates |
| Cell Viability | Optimized for minimal mechanical stress |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IsoSpark |
| Pricing | Available Upon Request |
| Brand | JIMBIO |
|---|---|
| Model | CL II |
| Detection Time | 40 s |
| Sample Volume | 10 µL (full-sample analysis) |
| Concentration Range | 1×10⁴–1×10⁷ cells/mL |
| Particle Diameter Range | 5–30 µm |
| Resolution | 0.5 µm |
| CV Value | ≤5% |
| Cleaning | Fully automated in-situ rinse cycle |
| Data Interface | USB 2.0 |
| Power Supply | Dedicated external power adapter |
| Integrated System | Yes |
| Regulatory Compliance | 21 CFR Part 11-ready, 3Q validated (IQ/OQ/PQ documentation available) |
| Brand | JJD |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JD-S |
| Price Range | USD 14,000–42,000 |
| System Type | Integrated Cell Observation Platform |
| Workbench Surface Finish | 8K Mirror-Polished Stainless Steel |
| Optical Magnification | 7×–180× |
| Video Magnification | 460× |
| Monitor Size | 17-inch LCD |
| Cold Light Source | 150 W, 21 V, 60 Hz, Uniformly Adjustable Intensity |
| Power Supply | 220 V, 50 Hz |
| Bench Dimensions | 1000 × 600 × 800 mm |
| Temperature Stability | Continuous operation at 37 °C ambient |
| Imaging Capability | Real-time capture, time-lapse recording, digital archiving |
| Stage Motion | Motorized X-Y translation platform |
| Objective Lenses | Standard 10× (optional 5× and 40×) |
| Camera | High-resolution digital CCD sensor |
| Illumination | Fiber-optic cold light delivery |
| Software Control | PC-based acquisition and annotation suite |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Kaluza |
| Product Type | Flow Cytometry Data Analysis Software |
| Intended Use | Research-Grade Flow Cytometry Data Processing |
| Minimum Display Resolution | 1440×900 |
| File Format Support | FCS 2.0/3.0/3.1, LMD |
| Operating System | Windows 7 (64-bit) and later |
| Brand | Kilby |
|---|---|
| Origin | Beijing, China |
| Model | K-TDMG2403A |
| Simulated Gravity Range | 10⁻³g (microgravity) to 3g (hypergravity) |
| Gravity Monitoring | Triaxial (X/Y/Z), ±0.001g resolution |
| Rotation Modes | 4 microgravity presets (1–4 rpm), 3 hypergravity presets (2.0g, 2.5g, 3.0g) |
| Sample Holders | ≥12× T25 vented flasks |
| Environmental Compatibility | Designed for integration into standard CO₂ incubators (up to 37°C, 5% CO₂) and biochemical incubators |
| Control Interface | Touchscreen with real-time gravity display, programmable scheduling, and integrated HD monitoring camera |
| Compliance | Engineered to support GLP-compliant workflows |
| Brand | Leica Biosystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aperio GT 450 |
| Pricing | Available Upon Request |
| Maximum Throughput | 450 slides |
| Slide Rack Capacity | 15 racks × 30 slides or 15 racks × 20 slides |
| Rack Compatibility with Leica HistoCore SPECTRA | Yes |
| Continuous Loading During Scanning | Yes |
| Priority Rack Scanning | Yes |
| Objective Magnification | 40× |
| Pixel Resolution | 0.26 µm/pixel at 40× |
| Scan Speed (15 mm × 15 mm FOV at 40×) | 32 seconds |
| Sustained Throughput | 81 slides/hour |
| Automated Image Quality Control | Yes |
| Slide Dimensions | 1" × 3" (25.4 mm × 76.2 mm) |
| Field of View (FOV) | 1 mm diameter |
| Barcode Recognition | Supports 1D (Code 128, Code 39) and 2D (DataMatrix, QR) symbologies |
| Dimensions (W × L × H) | 20.8" × 23" × 19.5" (52.83 cm × 58.43 cm × 49.53 cm) |
| Weight | 140 lbs (63.5 kg) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | CELL DIVE Solution |
| Category | Ultra-Multiplex Tissue Imaging & Spatial Biomarker Quantification System |
| Regulatory Status | CE-IVD compliant (for research use only in US) |
| Software Platform | CELL DIVE Analysis Suite v3.2+ |
| Imaging Modality | Cyclic Immunofluorescence (cycIF) with Automated Staining, Imaging, and Stripping |
| Max Biomarkers per Section | ≥60 |
| Spatial Resolution | Subcellular (≤300 nm lateral resolution with confocal mode) |
| Throughput | Up to 12 tissue sections per run |
| Data Output Format | OME-TIFF, JSON metadata, CSV cell-level feature tables |
| Compliance | ISO 13485 certified manufacturing, FDA 21 CFR Part 11–ready audit trail (software-enabled), GLP/GMP-compatible workflow logging |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | HistoCore SPECTRA ST-CV |
| Dimensions (closed) | 135.4 × 78.5 × 58.5 cm |
| Dimensions (open) | 135.4 × 78.5 × 94.3 cm |
| Weight (empty) | 185 kg |
| Weight (loaded) | ~220 kg |
| Power Supply | 100–240 V AC |
| Throughput | up to 330 H&E slides/hour |
| Slide Capacity | 1,600 slides per run |
| Staining Reagent Volume | 380 mL per bottle |
| Slide Rack Capacity | 30 racks (5 dedicated to special stains) |
| Tube Stations | 36 |
| Tube Wash Stations | 6 |
| Input/Output Drawer Slots | 5 per drawer (max. 150 slides continuous load) |
| Integrated Drying Oven | 6-rack capacity |
| Drying Time | ≤5 min |
| Brand | Leopard |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BFCC-8 |
| Detection Time | <10 s |
| Cell Concentration Range | 2×10³–3×10⁷ cells/mL |
| Sample Volume | 10 µL |
| Sample Throughput | 1–200 µm (particle size range) |
| Detectable Cell Diameter | 1–200 µm |
| Ambient Operating Temperature | 4–32 °C |
| Relative Humidity | <80% (non-condensing) |
| Objective Lens | 10× |
| Imaging Sensor | 12 MP (12 million pixel) CMOS camera |
| Onboard Storage | 500 GB |
| Interfaces | HDMI ×1, USB ×2, RJ45 ×1 |
| Power Input | AC 110/220 V, 50/60 Hz |
| Dimensions (W×D×H) | 280 × 280 × 370 mm |
| Weight | 8.2 kg |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L20001 |
| Detection Time | 30 s (fluorescence), 10 s (brightfield) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm (optimized for 5–60 µm) |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm (GFP), 600 nm (long-pass, RFP-compatible) |
| Light Source | High-stability LED |
| Image Resolution | 5 MP |
| Display | 800 × 480-pixel TFT LCD touchscreen |
| Dimensions (W×D×H) | 22 × 21 × 9 cm (8.6 × 8.3 × 3.5 in) |
| Weight | 1.8 kg (4 lb) |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L70001 |
| Detection Concentration Range | 1 × 10⁴ – 5 × 10⁷ cells/mL |
| Detectable Cell Size Range | 1–90 µm |
| Optical Modes | Brightfield, Dual-Fluorescence (Green: Ex 470±20 nm / Em 530±25 nm |
| Red | Ex 530±20 nm / Em 620±30 nm) |
| Autofocus | Motorized Precision Autofocus |
| Display | 7" Capacitive Touch LCD |
| Data Export | USB, Wi-Fi, Ethernet |
| Storage | 250 GB internal |
| Compliance | FDA 21 CFR Part 11 (via optional CountWire™ software) |
| Dimensions | 245 × 280 × 240 mm |
| Weight | 5.0 kg |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L10001 |
| Counting Time | <10 s (manual focus), <15 s (auto-focus) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Cell Size Range | 3–60 µm (optimal: 8–30 µm) |
| Viability Range | 0–100% |
| Image Resolution | 5 MP |
| Output Formats | TIFF (annotated), PDF reports |
| Dimensions (W×D×H) | 16 × 18 × 28 cm |
| Weight | 1.6 kg |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC output | 12 VDC, 3.3 A |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L30001 |
| Detection Time | 30–60 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm and 600 nm (long-pass) |
| Light Source | LED |
| Image Resolution | 5 MP |
| Display | 800 × 480 pixels |
| Dimensions (W×D×H) | 22 × 21 × 9 cm |
| Weight | 1.8 kg |
| Brand | Axion BioSystems |
|---|---|
| Model | Maestro Z / ZHT |
| Origin | USA |
| Manufacturer | Axion BioSystems, Inc. |
| Category | Imported |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | CellStream |
| Product Type | Flow Cytometry Analyzer |
| Lasers | Up to 7 (configurable) |
| Detection Channels | 22 |
| Fluorescence Sensitivity (MESF) | FITC < 10, PE < 5 |
| Flow Rate | 3.66–14.64 µL/min |
| Fluorescence Detection Limit | 20,000 events/sec |
| Cell Analysis Throughput | FITC MESF < 10, PE MESF < 5 |
| Detector Technology | Time-Delay Integration CCD (TDI-CCD) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | guava easyCyte 6-2L |
| Product Type | Flow Cytometer |
| Sample Vial Format | 1.2 mL or 1.5 mL microtubes |
| Fluorescence Channels | Red2 (661/19 nm), Red1 (690/50 nm), Yellow (583/26 nm), Green (525/30 nm) |
| Excitation Lasers | 488 nm blue laser, 638 nm red laser |
| Parameters Measured | 6-parameter (4 fluorescence + 2 light scatter) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | guava easyCyte 6HT-2L |
| Pricing | Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck Millipore (acquired Amnis) |
| Product Type | Imported Instrument |
| Model | FlowSight |
| Pricing | Available Upon Request |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Category | Imported |
| Model | Muse |
| Product Type | Flow Cytometry-Based Cell Analyzer |
| Pricing | Available Upon Request |