Chemical Analysis Instruments
Filter
Showing 3871–3900 of 4194 results
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ Absolute XR |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | Universal LC-MS/MS Analysis |
| Mass Range | Not Specified by Manufacturer |
| Sensitivity | Not Specified by Manufacturer |
| Resolution | Not Specified by Manufacturer |
| Mass Accuracy | Not Specified by Manufacturer |
| Operating Pressure Range | Not Specified by Manufacturer |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Xevo TQ-GC |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Gas Chromatography (GC) |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) |
| Software Platform | TargetLynx™, Quanpedia™, IntelliStart™ |
| Compliance Framework | Designed for GLP/GMP environments |
| Detection Principle | Selected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) in triple quadrupole configuration |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Model | Xevo TQ-S cronos |
| Configuration | LC-MS/MS System |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem mass spectrometry in Multiple Reaction Monitoring (MRM) mode |
| MRM Transition Rate | Up to 555 transitions per second |
| Linear Dynamic Range | >5 orders of magnitude |
| Typical Precision | <4% RSD for challenging analytes with 5 ms dwell time |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP audit trails, ISO/IEC 17025-aligned workflows |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQ-S micro |
| Ion Sources Compatibility | ESI, APCI, ESCi, UniSpray, APGC, ionKey/MS, ASAP, Nanoflow ESI |
| LC Compatibility | ACQUITY UPLC H-Class PLUS/Bio PLUS, I-Class PLUS, UPC2, M-Class |
| Key Technology | Z-Spray Ion Source, StepWave Off-Axis Ion Focusing |
| Regulatory Alignment | Compliant with SANTE/11813/2017, FDA 21 CFR Part 11 (via MassLynx software), GLP/GMP data integrity requirements |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQ-S |
| Ionization Flexibility | Universal Source Architecture |
| Key Technology | StepWave™ Ion Guide, T-Wave™ Collision Cell, RADAR™ Simultaneous Quant/Qual Mode |
| Software Suite | MassLynx™, TargetLynx™, QCMonitor™, IntelliStart™, Quanpedia™ |
| Regulatory Support | 21 CFR Part 11 compliant workflows, GLP/GMP-ready audit trails, ISO/IEC 17025-aligned data integrity framework |
| Brand | Waters |
|---|---|
| Origin | United Kingdom |
| Model | Xevo TQ-XS |
| Instrument Type | Tandem Quadrupole (Triple Quad) |
| Ionization Source Compatibility | UniSpray™, Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI) |
| Detection Principle | Selected Reaction Monitoring (SRM) / Multiple Reaction Monitoring (MRM) |
| Dynamic Range | 6 orders of magnitude (Xtended Dynamic Range, XDR™) |
| Ion Transmission Technology | StepWave XS™ off-axis ion optics |
| Probe Design | Tool-free atmospheric pressure ionization (API) source |
| Software Platform | MassLynx™ NX, TargetLynx XS™, Intellistart™, QUANPEDIA™ |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP audit trails, electronic signatures |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | Xevo TQD |
| Ionization Flexibility | Universal Source Architecture Supporting ESI, APCI, ESCi, and Optional Atmospheric Pressure Photoionization (APPI) |
| Chromatographic Compatibility | Optimized for UPLC and HPLC Coupling |
| Data Acquisition Speed | High-speed MRM acquisition supporting sub-3-second UPLC peaks |
| Software Suite | MassLynx v4.2 with IntelliStart, Quanpedia, QCMonitor, TargetLynx, TrendPlot, and RADAR™ Mode |
| Regulatory Compliance Support | 21 CFR Part 11–compliant audit trails, electronic signatures, and GLP/GMP-ready workflow tools |
| Hardware Architecture | Robust RF-only quadrupole design with T-Wave collision cell for enhanced ion transmission and fragmentation efficiency |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Wave500, Wave700 |
| Detector Integration | Ultim Max EDS |
| Geometry | Focusing Rowland Circle with Curved Crystals |
| Energy Resolution | <10 eV at Mn Kα |
| Detection Limit | <100 ppm (typical, matrix-dependent) |
| Slit Mechanism | Motorized Incident Slit for Resolution/Background Optimization |
| Mounting Configuration | Tilted Geometry for Enhanced SEM Compatibility and Reproducible Sample Positioning |
| Compliance | Designed for integration with Zeiss SEM platforms (e.g., GeminiSEM, Sigma, Merlin) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam (Optical for Flame / Electronic for GF) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Detection Limit (Cu, Flame) | ≤0.002 μg/mL |
| Baseline Stability | Zero Drift ±0.002 Abs / 30 min |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–800 nm |
| Baseline Drift | ≤ 3 × 10⁻⁵ AU/h |
| Wavelength Accuracy & Reproducibility | ≤ ±0.1 nm |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ELSD |
| Compatible Instrument | Liquid Chromatography (HPLC/UHPLC) |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | Visible Light (400–700 nm) |
| Detection Principle | Light Scattering of Nebulized Analyte Particles |
| Light Source | High-Stability LED |
| Nebulization/Evaporation/Detection Gas Flow | Independently Controlled Triple-Gas System |
| Display | 7-inch Capacitive Touchscreen LCD |
| Operating Temperature Range | Ambient to 120 °C (Evaporator), Adjustable in 1 °C Increments |
| Sensitivity | Sub-nanogram Level for Non-Volatile and Semi-Volatile Compounds |
| Compliance | Designed to Support GLP/GMP Environments with Audit-Trail-Capable Software Integration |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FLD |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 200–650 nm |
| Detection Mode | Fluorescence |
| Light Source | Mercury-Xenon Lamp |
| Display Interface | Touchscreen LCD |
| Data Output | Dual Analog Channels |
| Communication Interfaces | RS232, Ethernet |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Brand | Wayeal |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model Series | GC6000 |
| Temperature Control Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Carrier Gas Flow Control | Electronic Flow Control (EFC) |
| Injector Maximum Operating Temperature | 400 °C |
| Detector Options | FID6000 (standard), ECD (optional) |
| Autosampler Compatibility | ALS6000 (optional) |
| Air Purification System | Wayeal-built (optional) |
| MS Interface | 预留接口 (MS coupling port available upon request) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC6100 |
| Application Scope | General-Purpose |
| Control Architecture | Dual-Core Mainboard (Quad-Core Application Processor + Dual-Core Co-Processor) |
| Temperature Control | PID with Auto-Tuning & Environmental Compensation |
| EPC System | High-Stability Electronic Pressure Control |
| Detectors Supported | FID (1000 Hz Sampling Rate, 0.5 ms Minimum Peak Width), ECD (Low-Radiation Microcell), MS (Integrated with WAYEAL Mass Spectrometer) |
| Software Platform | SmartLab CDS Workstation with H.B.C-ApexFinder & SmartPeak Algorithms |
| Connectivity | Web-Based UI, Touchscreen (10.1" Capacitive), Remote Access via Browser |
| Compliance Features | Audit Trail, User Permission Levels, Electronic Signatures (FDA 21 CFR Part 11 Ready), GLP/GMP Data Integrity Support |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer | WAYEAL Scientific Instrument Co., Ltd. |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| System Architecture | Integrated GC-MS Platform |
| Control Software | Unified GUI for Acquisition, Processing & Reporting |
| Compliance Framework | Designed to support GLP/GMP workflows and 21 CFR Part 11–ready audit trail functionality (configuration-dependent) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | High-Capacity Direct-Pressure Helium Leak Detector |
| Pricing | Available Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | High-Precision Differential Pressure Leak Tester |
| Pricing | Available Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZH600-X Multi-Station Hermeticity Leak Detector |
| Pricing | Available Upon Request |
| Pressure Sensor Range (ZH600-X) | 10–500 kPa (mechanically regulated) |
| Sensor Accuracy | ±0.1% FS |
| Display Resolution | Adjustable to 0–4 decimal places |
| Pressure Units | kPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg |
| Leak Rate Units | Pa, kPa, Pa/s, kPa/s, kPa/min, mL/s, mL/min, mL/h, L/min, L/h, SCCM |
| Programmable Test Profiles | 64 total (16 per channel across A/B/C/D channels) |
| Test Cycle Time | 0–999 s (max test duration: 1800 s) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Required Test Gas Source | Clean, dry, ≥500 kPa supply pressure, ≥100 kPa above test pressure |
| Dimensions (ZH600-X) | 431 × 187 × 460 mm |
| Weight | ~14 kg |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | IC6000 Plus |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | Universal Anion/Cation Analysis |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 21 MPa |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | IC6200 Series |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 35 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Eluent Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | 35 MPa (main unit) / 21 MPa (Eluent Generator) |
| Temperature Control Range | 4–65 °C |
| Temperature Reproducibility | ±0.005 °C |
| Eluent Concentration Range | 0–100 mmol/L (KOH) or 0–15 mmol/L (K₂CO₃) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Model | IC6500 |
| Pump Pressure Rating | 42 MPa |
| Operating Temperature Range | 5 °C to 70 °C |
| Flow Path Material | Full PEEK |
| Detector Configuration | Dual Conductivity Detector |
| Eluent Generation | Integrated On-Line Electrolytic Eluent Generator |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | IC6600 Series |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Pump Maximum Pressure | 35 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Eluent Flow Rate Range | 0.001–10.000 mL/min |
| Max Operating Pressure | 35 MPa (main unit) / 21 MPa (eluent generator) |
| Operating Temperature Range | 4–65 °C |
| Temperature Reproducibility | ±0.005 °C |
| Eluent Concentration Range | 0–100 mmol/L (KOH) |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LC103(V5) / LC101(V6) Wide-Range Flow-Based Leak Detector |
| Price Range | USD 14,000 – 28,000 |
| Flow Range | 30–1000 mL/min (selectable) |
| Pressure Regulation | Mechanical, 10–600 kPa (selectable) |
| Test Pressure Units | kPa, MPa, kg/cm², psi, mbar, bar, Torr, mmH₂O, mmHg |
| Leak Rate Units | mL/s, mL/min, L/min, L/h, m³/h, Pa/min, g/h, SCCM |
| Display Resolution | Adjustable to 0–4 decimal places |
| Sensor Accuracy | ±3% F.S. (LC103 V5), ±0.1% F.S. (LC101 V6) |
| Programmable Test Profiles | 64 sets |
| Test Cycle Timing | 0–999 s |
| Max Test Duration | 1800 s |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Required Test Gas Source | Clean, dry, ≥500 kPa supply pressure, at least 100 kPa above test pressure |
| Dimensions (V5) | 330 × 222 × 448 mm |
| Dimensions (V6) | 321 × 205 × 460 mm |
| Weight | ~16 kg |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC3200S Series |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Maximum Operating Pressure | 45 MPa |
| Wavelength Range (UV/Vis Detector) | 188–900 nm |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LC3400 |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Maximum Operating Pressure | 75 MPa |
| Application Scope | General-Purpose HPLC/UHPLC Analysis |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | LC3500 Plus |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical chromatography |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Software Compatibility | Native support for WAYEAL ChromNav CDS (Chromatography Data System), compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LC3600 Series |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Instrumentation |
| Wavelength Range | 188–900 nm |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | Modular Differential Pressure Airtightness Leak Tester |
| Pricing | Upon Request |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RID-2000 |
| Detector Type | Refractive Index Detector (RID) |
| Signal Channels | 2 |
| Compatible System | HPLC |
| Output Modes | Digital Protocol (RS-485/Modbus) & Analog (0–5 V / 4–20 mA) |
| Display | 7-inch Capacitive Touch LCD |
| Light Source | Long-life High-Stability LED |
| Temperature Control | Precision Heated Flow Cell with PID Regulation |
| Leak Detection | Integrated Photoelectric Sensor with Real-time Alert |
| Compliance | Designed for ISO/IEC 17025-aligned QC labs |
| Brand | WAYEAL |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | SFJ-16C / SFJ-16D |
| Base Pump | Rotary Vane Vacuum Pump (SFJ-16C) / Scroll Vacuum Pump (SFJ-16D) |
| Minimum Detectable Leak Rate (Vacuum Mode) | 5.0 × 10⁻¹³ Pa·m³/s |
| Minimum Detectable Leak Rate (Sniffer Mode) | 2.5 × 10⁻⁹ Pa·m³/s |
| Maximum Allowable Test Pressure | 1800 Pa |
| Human-Machine Interface | 7-inch Color TFT LCD Touchscreen |
| Leak Port Connection | DN25 KF |
| Dimensions (W×D×H) | 475 × 714 × 1168 mm |
| Power Supply | AC 220 V (±10%), 50/60 Hz |
| Response Time | <1 s |
| Pump-Down/Startup Time | <95 s |
| Detectable Masses | m/z = 2 (H₂), 3 (³He), 4 (⁴He) |
| Ion Source | Dual Filament, Yttria-Coated Iridium, Auto-Switching |
| I/O Interfaces | RS-232, RS-485, LAN, MES Integration Ready |
| Operating Temperature | 0–40 °C |
| Display Languages | English & Chinese |
| Leak Rate Visualization | Numeric Value, Bar Graph, Real-Time Trend Curve |
| Compliance | Designed for ISO 10110-7, ASTM E1003, and JIS Z 2301 aligned workflows |
