Chemical Analysis Instruments
Filter
Showing 3961–3990 of 10741 results
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| pH Measurement Range | 0.000–14.000 (Resolution: 0.001 pH) |
| mV Measurement Range | ±2000.0 mV (Resolution: 0.1 mV |
| Accuracy | ±0.1 mV) |
| Temperature Range | −5 to 125 °C (Resolution: 0.1 °C) |
| Burette Precision | 1 µL (20 mL standard burette) |
| Burette Resolution | 0.5 µL (10 mL optional burette) |
| Endpoint Detection Modes | EQP (Equivalence Point), EP (Endpoint) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | STI5000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.003–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Maximum Pressure | 5400 psi |
| Injection Mode | Manual (Reodyne 7725i injector) |
| Standard Injection Volume | 20 µL |
| Column Oven Temperature Range | Ambient to 60 °C |
| UV-Vis Wavelength Range | 190–700 nm (extendable to 850 nm) |
| Data Acquisition Rate | 20 Hz |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TCl-1 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Cement-Specific |
| Potential Range | ±2000 mV |
| pH Range | 0–14 pH |
| Potential Resolution | 0.01 mV |
| pH Resolution | 0.01 |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Titration Volume | 20 mL |
| Minimum Dispensing Increment | 0.001 mL per step |
| Titration Repeatability | RSD ≤ 1% |
| Titration Accuracy | ±1 µL |
| Potential Measurement Accuracy | ±0.3 mV ±1 digit over 3 h |
| Electrode System | Chloride Ion-Selective Electrode + Double-Junction Saturated Calomel Reference Electrode (Outer Junction: KNO₃ |
| Inner Junction | KCl) |
| Data Export | PDF via USB or WLAN |
| GLP Compliance | Electrode calibration logs, titrant standardization records, user operation audit trail, non-overwritable data history |
| Environmental Operating Conditions | 5–35 °C, ≤80% RH |
| Power Supply | 100–220 V AC, 50–60 Hz |
| Dimensions (W×D×H) | 250 × 360 × 330 mm |
| Weight | 10 kg |
| Brand | SGM |
|---|---|
| Origin | Beijing, China |
| Model | KY-PE |
| Designed Compatibility | PerkinElmer Atomic Absorption Spectrometers |
| Rated Lifetime | ≥5000 mAh (most elements), ≥3000 mAh (low-melting-point elements) |
| Intensity Noise | <0.1% RMS |
| Drift Stability | ≤1% over 30 min after 30-min warm-up |
| Spectral Background at Analytical Line | ≤1% |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LC-R720 |
| Operating Principle | Liquid Crystal on Silicon (LCoS)-Based Optical Phase/Amplitude Modulation |
| Imaging Method | Binary Optical Element |
| Deployment Environment | Benchtop / Laboratory |
| Spectral Range | 420–700 nm |
| Spatial Resolution | 1280 × 768 pixels |
| Pixel Pitch | 20 µm |
| Fill Factor | 92% |
| Addressing Depth | 8-bit |
| Frame Rate | 180 Hz |
| Response Time | <3 ms |
| Phase Modulation Range | >π radians (visible spectrum) |
| Dynamic Range | 1000:1 |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 78 µrad |
| Synchronization | Hardware Trigger Support |
| Video Interface | Digital Visual Interface (DVI) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | LETO-3 |
| Spectral Range | 400–1100 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 6.4 µm |
| Fill Factor | 93% |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µrad |
| Frame Rate | 60 Hz |
| Interface | HDMI (video input), USB 2.0 (control) |
| Operating Mode | Pure-phase modulation only |
| Optical Configuration | Transmissive, binary-optical element |
| Mounting | Benchtop / Ground-based optical setup |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1 NIR-015 |
| Spectral Range | 650–1100 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µrad |
| Frame Rate | 60 Hz |
| Addressing | 8-bit grayscale via VGA/HDMI/DisplayPort (green channel), USB-controlled gamma and voltage range tuning |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PLUTO-2.1 NIR-145 |
| Spectral Range | 420–1064 nm |
| Resolution (Spatial & Spectral) | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Total Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µm |
| Frame Rate | 60 Hz |
| Interface | USB-controlled driver + HDMI/DisplayPort video input |
| Operating Mode | Pure-phase modulation |
| Compatibility | Standard GPU-based phase pattern streaming via green-channel 8-bit grayscale addressing |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PLUTO-2.1-NIR-118 |
| Operating Wavelength Range | 730–950 nm |
| Spatial Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 62.5 lp/mm |
| Frame Rate | 60 Hz |
| Modulation Type | Pure-Phase, Liquid Crystal on Silicon (LCoS) |
| Interface | USB-controlled gamma calibration + HDMI/DisplayPort video input |
| Bit Depth | 8-bit grayscale (green channel addressing) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1-TELCO-013 |
| Spectral Range | 1400–1700 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 7.8 µrad |
| Frame Rate | 60 Hz |
| Modulation Type | Pure-Phase, Liquid-Crystal-on-Silicon (LCoS) |
| Brand | Holoeye |
|---|---|
| Origin | Germany |
| Model | PLUTO-2.1-VIS-016 |
| Spectral Range | 420–650 nm |
| Resolution | 1920 × 1080 pixels |
| Pixel Pitch | 8 µm |
| Field of View (TFOV) | 15.36 × 8.64 mm |
| Instantaneous Field of View (IFOV) | 62.5 lp/mm |
| Frame Rate | 60 Hz |
| Interface | USB-controlled gamma calibration + HDMI/DisplayPort video input |
| Operating Mode | Pure-phase modulation via liquid crystal on silicon (LCoS) |
| Brand | Hongtu |
|---|---|
| Origin | Shandong, China |
| Model | SP-6802 |
| Detection Limit (as S in H₂S) | 0.01 mg/m³ (Type A, non-conversion) |
| Measurement Range (as S in H₂S, undiluted) | 0.01–50 mg/m³ (extendable to 0.1–500 mg/m³) |
| Repeatability (RMS error) | <5% (n ≥10, certified H₂S standard gas or CS₂ permeation source) |
| Column Temperature Control | Ambient to 100°C ±0.2°C |
| Permeation Source Temperature Control | Ambient to 50°C ±0.1°C |
| Detector Temperature Control | Ambient to 110°C ±1°C |
| Converter Furnace Temperature | Ambient to 900°C ±5°C |
| High-Voltage Power Supply | –400 V to –800 V adjustable |
| Compliance | GB/T 19001–2016 (ISO 9001), GB/T 14001–2016 (ISO 14001) |
| Brand | Hongweiliangzi |
|---|---|
| Origin | Shandong, China |
| Model | HW-DYS2 |
| Measurement Channels | 6 |
| Sample Throughput | 20 consecutive samples |
| Analysis Time per Sample (8 elements) | ≤5 min |
| Stability | ±1 digit within 5 min |
| Compliance Standards | GB/T 4734, GB/T 6900, QB/T 2578–2002 |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤85% |
| Power Supply | 220 V, 50/60 Hz |
| Power Consumption | 1 kW |
| Dimensions (Instrument) | 500 × 460 × 350 mm |
| Weight (Instrument + Packaging) | 15 kg |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Flame AAS |
| Model | HD-AAS4H |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner enhanced optical system |
| Grating Density | 1800 lines/mm |
| Spectral Bandwidth | 0.2 / 0.4 / 1.0 / 2.0 nm (auto-switchable) |
| Wavelength Accuracy | ≤ ±0.1 nm |
| Wavelength Repeatability | ≤ ±0.025 nm |
| Resolution | 0.2 nm (Cu 324.7 nm, 0.2 nm bandwidth) |
| Baseline Drift | 0.003 ABS/30 min (static), 0.005 ABS/15 min (dynamic) |
| Detector | Hamamatsu photomultiplier tube |
| Background Correction | Deuterium lamp |
| Characteristic Concentration (Cu) | 0.025 µg/mL/1% |
| Detection Limit (Cu) | 0.006 µg/mL |
| Precision (RSD) | ≤ 0.5% |
| Atomizer | Titanium 0.5 mm × 100 mm burner head |
| Nebulizer | High-efficiency glass nebulizer with metal cap |
| Spray Chamber | Corrosion-resistant all-plastic chamber |
| Safety System | Real-time acetylene leak detection, flame-out monitoring, gas pressure interlock, automatic shutdown |
| Lamp System | Motorized turret for 4/6/8 lamp positions |
| Data Interface | RS232, USB |
| Software | Windows-compatible AAS control suite with dual-language UI (EN/CN), remote calibration support, GLP-compliant audit trail, multi-format export (CSV, PDF, Excel) |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 400 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–800 nm |
| Analog-to-Digital Resolution | 16-bit per pixel |
| Optical Architecture | Paschen-Runge Mount with Rowland Circle Design |
| Vacuum System | Intermittent Vacuum Maintenance |
| Compliance | ASTM E415, ISO 11573, GB/T 4336 (Chinese National Standard for Spark OES) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 0030-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Sensor Type | Integrated Silicon-based Ion-Sensitive Field-Effect Transistor (ISFET) |
| Tip Geometry | Flat-ended needle tip |
| Tip-to-Sleeve Gap | < 100 µm |
| Electrode Body Material | Chemically resistant polymer |
| Storage | Dry storage compatible (no KCl solution immersion required) |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ASTM D1293 and ISO 3696 Grade 3 water monitoring protocols |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 0040-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Solid-State ISFET (Ion-Sensitive Field-Effect Transistor) |
| Sensing Surface | Flat-tip, <100 µm gap between sensor surface and protective sleeve |
| Compliance | Designed for GLP/GMP-relevant environments |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3551-10D |
| Cell Constant | 10 m⁻¹ (0.1 cm⁻¹) |
| Conductivity Range | 10 µS/cm to 1 S/cm (0.1 µS/cm to 10 mS/cm) |
| Minimum Sample Volume | 50 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014081712 (9056000800) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3551-10D |
| Cell Constant | 10 m⁻¹ (0.1 cm⁻¹) |
| Conductivity Range | 10 µS/cm to 1 S/cm (0.1 µS/cm to 10 mS/cm) |
| Minimum Sample Volume | 50 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014081712 (9056000800) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3561-10D |
| Cell Constant | 10 m⁻¹ (0.1 cm⁻¹) |
| Conductivity Range | 10 μS/cm to 1 S/cm (0.1 μS/cm to 10 mS/cm) |
| Minimum Sample Volume | 10 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014082350 (Legacy: 9056001100) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3562-10D |
| Conductivity Range | 0.1 mS/cm to 10 S/cm (1 µS/cm to 100 mS/cm) |
| Cell Constant | 100 m⁻¹ (1 cm⁻¹) |
| Minimum Sample Volume | 16 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014082513 (Legacy: 9056001200) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 4163-10T |
| Temperature Range | 0–100 °C |
| Compatibility | Designed for use with HORIBA pH/ORP meters (e.g., LAQUA series) and compatible third-party analyzers requiring Pt1000 or analog temperature input |
| Output Signal | Analog (2-wire RTD, Pt1000 class B per IEC 60751) |
| Enclosure Material | Chemically resistant PPS (polyphenylene sulfide) body with stainless steel tip |
| Cable Length | 1 m standard (custom lengths available) |
| IP Rating | IP67 |
| Calibration Traceability | NIST-traceable reference data provided upon request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9300-10D |
| Temperature Range | 0–60 °C |
| Electrode Type | Waterproof Pt/Ag-AgCl Composite ORP Electrode |
| Body Material | Titanium |
| Output Signal | mV (vs. Standard Hydrogen Electrode) |
| Compatibility | Designed for standalone ORP measurement only — not to be used concurrently with pH or other reference electrodes |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Type | Composite Redox Electrode (Pt/Ag-AgCl Reference) |
| Model | 9300-10D |
| Temperature Range | 0–60 °C |
| Body Material | Waterproof Glass |
| Electrode Configuration | Integrated Pt Sensing Element + Double-Junction Ag/AgCl Reference |
| Compatibility | Aqueous Solutions, Wastewater, Industrial Process Streams |
| Electrical Connection | BNC |
| IP Rating | IP67 (when capped) |
| Calibration Support | Single-point or multi-point ORP standard verification (e.g., ±200 mV, +450 mV Zobell’s solution, +220 mV saturated quinhydrone) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9300-10D |
| Temperature Range | 0–60 °C |
| Electrode Type | Waterproof Pt-based composite redox electrode |
| Compatibility | Designed for standalone ORP measurement (not to be used simultaneously with pH or other reference electrodes) |
| Compliance | Engineered for routine electrochemical monitoring in accordance with ISO 10523, ASTM D1293, and EPA Method 150.1 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| Compliance | ISO 3696 (Grade 2 water), ASTM D1293, USP <791>, JIS Z 8802 |
| Electrode Type | Integrated Glass pH Sensor + Ag/AgCl Reference + Pt ORP Element + NTC Thermistor |
| Body Material | Chemically Resistant PPS Plastic |
| Tip Geometry | Flat-Surface Ceramic Junction with Sub-100 µm Guard Gap |
| Response Time (t₉₀) | ≤15 s (pH 4 → 7 → 10 buffer transition, 25 °C) |
| Drift | <0.01 pH/h (24 h, stable electrolyte fill) |
| Mechanical Strength | >10× JIS R 3201 (Glass Electrode Impact Resistance Standard) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9618-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Combination pH Electrode with Flat-tip ISFET-enhanced Glass Membrane |
| Compliance | JIS Z 8802 (pH electrode performance), ISO 7888 (water quality — pH determination) |
| Enclosure Material | Chemically resistant PPS body |
| Tip Geometry | Hemispherical + flat-surface sensing zone |
| Reference System | Cation-conductive hollow-fiber junction |
| Response Time (t₉₀) | ≤15 s (typical, at 25 °C, ΔpH = 1.0) |
| Mechanical Strength | >10× JIS Z 8802 specified impact resistance |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9625-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| ORP Range | ±1500 mV |
| Electrode Type | Combination pH/ORP/Temp (3-in-1), Gel-Filled, Plastic Body, Flat-Tipped ISFET-Glass Hybrid Design |
| Response Time (pH) | ≤15 s (t₉₀, ΔpH = 1.0) |
| Drift | <0.01 pH/h (25 °C, buffered solution) |
| Reference System | Cation-Selective Hollow-Fiber Junction |
| Glass Membrane | Rare-Earth-Doped High-Strength Bulb (JIS S 6001 Compliant, >10× strength) |
| Storage | Dry (no KCl soaking required) |
| Electrode Head Geometry | Flat, 100 µm clearance to protective sleeve |
| ESD Protection | Integrated semiconductor-grade anti-static circuitry |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9680-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| Electrode Type | Composite Glass pH Electrode with Integrated Reference System |
| Body Material | Chemically Resistant Plastic |
| Tip Geometry | Flat-Surface, Semi-Hemispherical Bulb |
| Compliance | JIS Z 8802 (pH Electrode Performance Standards), ISO 7027 (for optical interface compatibility in hybrid systems) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9681-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Combined Glass/Reference/ATC (Integrated Temperature Compensation) |
| Construction | Ruggedized Plastic Body with Hemispherical Tip |
| Sensing Surface | Flat-Tip Glass Membrane |
| Compliance | Meets JIS Z 8802 for pH electrode mechanical strength (10× requirement) |