| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry Dedicated |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Time | ~6 minutes (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Solvent Residue GC for Plastic Flexible Packaging |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific |
| Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | ~6 min (400°C → 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | Refinery Gas-Specific GC |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD and FID |
| Column Types | Packed and Capillary |
| Multi-Valve Auto-Switching | Yes |
| Signal Auto-Switching | Yes |
| Analysis Scope | H₂, O₂, N₂, CO₂, CO, C₁–C₆₀ hydrocarbons (including C₂=–C₄= olefins and C₆⁺ saturates/olefins/aromatics) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Solvent Residue Analysis in Edible Oils, Food Additives, and Pesticide Residues |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Time | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column Compatibility | Capillary columns for volatile organic solvent separation (e.g., DB-VRX, HP-PONA, or equivalent polar/non-polar GC columns) |
| Data System | Integrated GC workstation with peak integration, calibration curve generation, and audit-trail-capable reporting |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | Solvent Residue-Specific Gas Chromatograph |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Instrument Type | Laboratory-Grade Gas Chromatograph |
| Primary Application Domain | Food Packaging Safety Testing |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Flame Ionization Detector (FID) |
| Column | Pre-configured Capillary Column for Volatile Organic Solvent Separation |
| Data System | Integrated Chromatography Workstation with Audit Trail Capability |
| Required Gases | High-Purity Nitrogen (carrier), Hydrogen (detector fuel), and Compressed Air (detector oxidant) |
| Brand | HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TDS-3410A |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–300 mL/min |
| Tube Capacity | 6–10 tubes |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | ±0.5% of setpoint |
| Timer Range | 0–655 minutes |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Italy |
| Model | HT200H Headspace Autosampler |
| Sample Capacity | 40 positions (for 10 mL or 20 mL headspace vials) |
| Sample Heating Block | Simultaneous heating of up to 6 vials |
| Heating Temperature Range | 40–150 °C |
| Heating Time Range | 0–23 h 59 min |
| Agitation Duration | 0–99 min |
| Agitation Speed | Adjustable |
| Syringe Volume | Standard 2.5 mL, optional 5 mL |
| Minimum Injection Volume | 0.01 mL |
| Injection Flow Rate | 0.1–100 mL/min |
| Equilibration Delay | 0–60 s |
| Needle Temperature Control | 40–150 °C |
| Carrier/Purge Gas | Inert gas (N₂ or He) |
| Extraction Mode | Multiple Headspace Extraction (MHE), up to 15 cycles |
| Software Compatibility | HT-Comsoft-H and Clarity Chromatography Data Systems |
| Position Flexibility | Removable sample tray configurable for left- or right-side installation |
| Brand | HTA |
|---|---|
| Origin | Italy |
| Model | HT4150L |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 32 tubes (2 × 16-position racks) |
| Minimum Dispensing Volume | 0.1 mL |
| Quantitative Loop Volumes | 1 mL and 2.5 mL |
| Positioning Accuracy | < 0.2 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external wall rinsing |
| Repeat Injection Capability | Unlimited cycles |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis (Specialized for Kr, He, Ne, Xe, Ar) |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate (350 °C → 50 °C) | ≤8 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Detection Limit (for N₂, O₂, CH₄, CO, CO₂, H₂, H₂O, CF₄) | ≤5 ppb (v/v) |
| Detector Type | High-Sensitivity Helium Ionization Detector (HID) |
| Column Configuration | Multi-Column Oven with Independent Temperature Zones |
| Sample Introduction | Dual-Channel Valve System with Purge-Protected Switching Valves |
| Flow Compensation | Automatic Inlet Pressure Correction Algorithm for Variable Base-Gas Matrices |
| Compliance Reference | GB/T 5829–2006 (Krypton Specification), GB/T 28123–2011 (High-Purity Noble Gases), ASTM D7606–22 (Trace Impurity Analysis in Ultra-High-Purity Gases) |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-PDD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Dedicated High-Purity & Electronic Specialty Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | ~7 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–500 psi |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | GC-9560-HD DGA System |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Power Industry–Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Column Oven Cooling Time | <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399 °C |
| Injector Pressure Setpoint Range | 0–0.4 MPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detection Limits (as per DL/T 703–1999) | H₂ <2 µL/L, O₂ <5 µL/L, N₂ <5 µL/L, CO <2 µL/L, CO₂ <2 µL/L, Hydrocarbons <0.1 µL/L |
| Temperature Stability | ±0.1 °C across all zones (oven, injector, detectors, methanizer) |
| Detectors | Dual-channel TCD and FID with Ni-catalyst methanizer |
| Column Configuration | Parallel dual-column gas separation path |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560-HM |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Temperature Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~50 °C in ≤7 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Dimensions | 315 × 300 × 195 mm |
| Temperature Control Precision | ±0.1 °C (six independent zones) |
| Programmed Temperature Ramping | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| Detector | TCD (Thermal Conductivity Detector), dual-channel, rhenium-tungsten filament, constant-current operation |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane/isooctane) |
| Baseline Noise | ≤15 μV |
| Baseline Drift | ≤100 μV/30 min |
| Linearity | ≥10⁴ |
| Compliance | GB 10410–1989 |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GC-9780A |
| Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane/isooctane) |
| Repeatability | <3% RSD |
| Weight | <48 kg |
| Dimensions | 590 × 550 × 680 mm |
| Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HA-9660-PDD |
| Instrument Type | Online Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8°C above ambient to 400°C |
| Ramp Rate | 1–40°C/min |
| Cool-down Rate | 400°C to 50°C in 7 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min (electronic monitoring) |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa (8-step setting) |
| Injector Max Temp | 400°C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detector | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Detection Limit | ≤5 ppb |
| Drift/Repeatability | ±1%–±5% |
| Sample Gas Flow | 50 mL/min |
| Sample Gas Pressure | 0.1 MPa |
| Sample Inlet | 1/4″ Swagelok SS |
| Carrier Gas | He |
| Carrier Inlet | 1/8″ Swagelok SS |
| Display | LED |
| Power Supply | AC 220 V, 50–60 Hz |
| Power Consumption | 400 W |
| Weight | 20 kg |
| Dimensions | 482 mm (W) × 222 mm (H) × 400 mm (D), 5U rack-mountable |
| Communication Interface | RS-232 / RS-485 |
| Protocol | Modbus |
| Brand | Huai Chromatography |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9560-HC |
| Temperature Control Range | 0–400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cool-down Rate | 350→50 °C in ≤8 min |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Limit (H₂ matrix, TCD) | O₂/N₂/CO/CH₄/CO₂ ≤ 0.1–2 ppm (3 mL sample) |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | GC-9760A |
| Price Range | USD 14,000 – 42,000 |
| Dimensions | 380 × 450 × 180 mm |
| Weight | <15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Column Oven Temp Range | 8 °C above ambient to 400 °C (±0.1 °C) |
| TCD Detection Limit | ≤ 100 μL/L (H₂) |
| FID Detection Limit | ≤ 0.1 μL/L (C₂H₂) |
| Linear Dynamic Range | ≥10⁴ (TCD), ≥10⁶ (FID) |
| Standard Compliance | GB/T 17623–1998, GB/T 7252–2001, DL/T 703–1999 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petrochemical & Electronic Specialty Gases |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Maximum Ramp Rate | 40 °C/min |
| Oven Cooling Time | <5 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-1 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cool-down Time | ~7 min (350 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Column Oven Precision | ±0.1 °C |
| Programmed Temperature Steps | 8-step |
| Hold Time per Step | 0–655 min (1-min increments) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (n-hexadecane / isooctane) |
| FID Baseline Noise | ≤2×10⁻¹³ A |
| FID Drift | ≤2×10⁻¹² A/30 min |
| FID Linearity | ≥10⁶ |
| TCD Sensitivity | ≥2500 mV·mL/mg (n-hexadecane / isooctane) |
| TCD Baseline Noise | ≤20 µV |
| TCD Drift | ≤100 µV/30 min |
| TCD Linearity | ≥10⁴ |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ± 22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GC-9560-EG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) and Electronic Grade (EG) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C in ~7 min |
| Carrier Gas Flow Control Range | 0–400 mL/min |
| Carrier Gas Pressure Control Range | 0–1000 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–400 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | GC-9560-HB |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | High-Purity Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Ramp Rate | 1–40 °C/min |
| Cooling Rate | ~7 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Specific |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~50 °C in ≈7 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-HG |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | +8 °C to 400 °C |
| Heating Rate | 1–40 °C/min |
| Cooling Rate | ~7 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization (PDHID) |
| Detection Limit | ≤1.0×10⁻¹⁰ g/mL (for organic compounds) |
| H₂ | 5 ppb, O₂/Ar: 10 ppb, N₂: 10 ppb, CH₄: 5 ppb, CO: 25 ppb, CO₂: 5 ppb |
| Temperature Control Precision | ±0.1 °C (eight independent zones) |
| Programmed Temperature Ramping | 8-step |
| Data Acquisition | 20 Hz, 24-bit A/D, dynamic range 10⁶ |
| Compliance | GB/T 28726–2012, GB/T 3634.2–2011, GB/T 14599–2008, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844–2011, GB/T 17873–1999, GB/T 5829–2006, GB/T 5828–2006, HG/T 3633–1999, GB 10621–2006, GB/T 23938–2009, GB/T 28125.1–2011 |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9560-HQ |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Rate | ~7 minutes from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9560-HS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum Refining & Fuel Quality Control |
| Temperature Control Range | Ambient +8 °C to 399 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Time | ~7 min (350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Max Operating Temperature | 399 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-HT |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8°C to 399°C |
| Maximum Ramp Rate | 40°C/min |
| Cooling Rate | 350°C → 50°C in <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC-9560-HTP |
| Price Range | USD 14,000 – 21,000 (FOB Shanghai) |
| Application Scope | General-Purpose Catalytic Reaction Monitoring |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-9560-N2 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry–Specific |
| Temperature Control Range | Ambient + 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 6 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9560-PDD |
| Temperature Control Range | 0–400 °C |
| Ramp Rate | 0–40 °C/min |
| Cool-down Rate | 350 °C → 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 psi |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDD) |
| Detection Limit for Trace Impurities | ≤5 ppb (v/v) in high-purity SiCl₄ matrix |
| Application Focus | Ultra-high-purity electronic-grade gas analysis (e.g., SiCl₄, SiHCl₃, SiH₂Cl₂, CH₃SiCl₂) |
| Column Configuration | Multi-oven column switching architecture with center-cutting valving |
| Sample Introduction | Backflush-capable, purged valve system with active guard gas routing |
| Pressure Calibration | Integrated automatic inlet pressure correction algorithm for variable-base-gas samples |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GC-9560-PED |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Ultra-High-Purity Gas Analysis |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Cooling Rate | 350 °C to 50 °C in ≤7 min |
| Carrier Gas Pressure Control Range | 0–0.4 MPa (8-step programmable) |
| Carrier Gas Flow Control Range | 0–0.4 MPa (8-step programmable) |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.1 MPa |
| Injector Total Flow Setting Range | 0–50 mL/min |
| Detection Limit | Sub-ppb (e.g., 0.5–20 ppb depending on analyte and carrier gas) |
| Temperature Stability | ±0.1 °C |
| Programmable Temperature Program | 8-stage |
| Dimensions | 655 mm (W) × 500 mm (H) × 480 mm (D) |
| Weight | ~48 kg |
| Power Supply | 220 V ±22 V, 50 Hz, ≥2 kW |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-9580-HD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry Dedicated |
| Temperature Control Range | 8 °C above ambient to 400 °C |
| Oven Ramp Rate | 1–40 °C/min |
| Oven Cool-down Time | ≤7 min (from 350 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–500 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–500 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |