| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PP-TOFMS |
| Acquisition Rate | 1 spectrum per 30 µs |
| Mass Resolution | 5,000 at m/z 208 (high-resolution mode) |
| Dynamic Range | 10⁷ |
| Mass Accuracy | ±40 ppm |
| Sensitivity | 10³ cps/ppm |
| Depth Resolution | down to 1 nm |
| Ion Modes | Positive and Negative |
| Flexible Ion Gating | up to 4 ions |
| Sample Loading | Horizontal, tool-free |
| Mass Coverage | H to U, including isotopes and molecular species |
| RF Pulsed Glow Discharge Mode | Patented |
| Quantitative Capability | Matrix-effect-minimized semi-quantitative depth profiling without calibration standards |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QuantaMaster 8000 |
| Wavelength Range | UV–NIR (up to 5500 nm) |
| Monochromator Type | Triple-grating Czerny-Turner with 300 mm focal length |
| Slit Resolution (Spectral Bandpass) | 0.01 nm |
| Optical Resolution | 0.1 nm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Wavelength Accuracy | ±0.3 nm |
| Excitation Sources | Up to 4 integrated sources including PowerArc™ Xe lamp and pulsed lasers (210–2200 nm) |
| Detection Channels | 6 configurable PMT/InGaAs/MCT channels |
| Lifetime Techniques | TCSPC, Strobe, SSTD (Single-Shot Time-Domain), up to 5500 nm |
| Automation | Fully motorized gratings, slits, mirrors, filter wheels, and accessory control via FelixGX software |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | QuantaMaster 8000 |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Resolution | 0.1 nm |
| Slit Width (Spectral Bandpass) | 0–30 µm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Dispersive Element | Grating |
| Pulse Excitation Capability | Up to 100 MHz |
| NIR Phosphorescence Lifetime Range | Up to 5500 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ratio Master |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Monochromator Type | Grating-Based |
| Spectral Bandpass | Adjustable down to <1 nm (typical operational minimum) |
| Wavelength Accuracy | ±0.2 nm (calibrated with Hg/Ne lamp traceable to NIST standards) |
| Detection Speed | Sub-2 ms wavelength switching |
| Temporal Resolution | ≤5 ms per dual-wavelength ratio frame (with optional high-speed PMT or sCMOS detection) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | RZ-660 |
| Price | Upon Request |
| Spectral Range | 680 – 3,800 cm⁻¹ |
| Spatial Resolution | < 5 µm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Instrument Type | Pen-Style pH Meter |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | 0–14 pH |
| Resolution | ±0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Solutions | pH 4.01 and pH 7.00 standard buffers |
| Temperature Compensation | Automatic (ATC) |
| Electrode Type | Flat-Surface pH Sensor |
| Minimum Sample Volume | 100 µL |
| Compliance | Designed for routine QC, field testing, and educational use in accordance with ISO 7888 and ASTM D1293 guidelines |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Aqualog |
| Dispersion Element | Grating and Filter |
| Slit Width (Spectral Bandpass) | 5 nm |
| Resolution | 0.41 nm/pixel |
| Sensitivity | 20,000:1 (water Raman SNR, RMS, 350 nm excitation, 30 s integration) |
| Wavelength Accuracy | ±1 nm |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.0 nm to 32 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity | >3000:1 |
| Wavelength Accuracy | ±0.5 nm |
| Detector Range (Standard) | 185–650 nm (upgradable to 850 nm or 900 nm) |
| Minimum Measurable Lifetime | 25 ps (with DeltaDiode/NanoLED) |
| Lifetime Range | 25 ps to 1 s (software-selectable source-dependent) |
| Excitation Sources | DeltaDiode (UV–NIR, 10 kHz–100 MHz rep. rate), NanoLED (UV–VIS, 10 kHz–1 MHz), SpectraLED (VIS–NIR, 0.1 Hz–10 kHz) |
| System Response FWHM | <200 ps (PPD/TBX + laser diode) |
| Dead Time | 10 ns |
| Time Range | 10 ns to 11 s (DeltaPro-DD configuration) |
| Interface | USB 2.0 (no PCI card required) |
| Operating System | Windows XP/7 (32-/64-bit English) |
| Dimensions (L×W×H) | 1875 mm × 1125 mm × 625 mm (excl. PC) |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | DeltaPro |
| Dispersion Element | Grating |
| Excitation Sources | NanoLED (up to 1 MHz), DeltaDiode (up to 100 MHz), SpectraLED (for phosphorescence, multi-wavelength) |
| Lifetime Range | 25 ps to >1 s |
| Detection Module | PPD photon counting detector (standard), optional NIR extension to ~1700 nm |
| Data Acquisition | Time-Correlated Single Photon Counting (TCSPC) with DeltaHub core (dead time: 10 ns) |
| Software Control | F-Link USB 2.0 interface, no PCI card required |
| Sample Compatibility | Liquid cuvettes (with temperature control & stirring), solid sample holders, large UV-grade sample chamber |
| Optional Accessories | Monochromators, motorized polarizers, automated optical components, PPD-850C/PPD-900C IR modules |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | DynaMyc |
| Detection Principle | Time-Correlated Single Photon Counting (TCSPC) |
| Lifetime Range | 100 ps – 10 µs |
| Spectral Detection Range | 185–650 nm / 300–850 nm (with TBX fast detector) |
| Spatial Resolution | 0.5 µm |
| Scan Stage Travel | 75 × 50 mm |
| Laser Source Options | Pulsed diode lasers (370–980 nm), DeltaDiode series, repetition rate up to 100 MHz, CW/pulsed mode selectable |
| Excitation Filtering | Motorized filter wheel with dichroic mirrors and pinholes (100–1000 µm) |
| Data Acquisition Modes | Single-point, multi-point, FLIM mapping |
| Software | DataStation (instrument control), DAS6 (lifetime decay analysis & deconvolution) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluoroCube |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Dispersive Element | Grating |
| Slit Width (Spectral Bandpass) | 1–32 nm |
| Spectral Resolution | 1 nm |
| Sensitivity | >3000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.05 nm |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Fluorolog-3 |
| Wavelength Range (Optional) | 185 nm – 14 µm |
| Excitation/Emission Monochromators | Single or Dual Grating |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Optical Resolution | 0.06 nm |
| Sensitivity | 20,000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.2 nm |
| Light Source | 450 W Xenon Arc Lamp |
| Detection Method | Photon Counting |
| Data Acquisition | TCSPC (Time-Correlated Single Photon Counting) for Lifetime Measurements |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | FluoroMax-4 |
| Wavelength Accuracy | ±0.5 nm |
| Spectral Bandwidth (Slit Width) | 0–30 nm |
| Optical Resolution | 0.2 nm |
| Sensitivity | >6000:1 (RMS method reported as up to 16,000:1) |
| Excitation Source | 150 W ozone-free Xenon lamp (vertically mounted) |
| Monochromator Type | Plane grating, Czerny-Turner design |
| Detection Mode | Photon counting |
| Optional Upgrades | TCSPC fluorescence lifetime module, phosphorescence lifetime unit, IR extension, integrating sphere, TIRF, Stop-Flow, polarization, temperature-controlled stages (Peltier & LN₂), microplate reader, microscope coupling |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Nanolog® |
| Excitation Source | 450 W continuous xenon lamp |
| Wavelength Range | UV–NIR (200–1700 nm, extendable to ~3 µm) |
| Spectral Resolution | 0.06 nm |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Sensitivity | >20,000:1 (at 1,550 nm, using liquid-nitrogen-cooled InGaAs array) |
| Detection Modes | Steady-state, time-resolved (TCSPC), and combined steady-state/time-resolved spectroscopy |
| Detector Options | PMT (UV–NIR), Symphony II InGaAs array (800–1700 nm |
| Lifetime Range | Fluorescence 100 ps–1 ms |
| Software | NanoSizer® for SWNT characterization (diameter distribution, FRET analysis), FluoroLog®-based acquisition and analysis suite |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Model | Tempro |
| Excitation Source | Pulsed LED/Laser Diodes (255–NIR) |
| Detection Range | 185–650 nm (upgradable to 850 nm or 1700 nm with optional NIR detectors) |
| Lifetime Range | 100 ps to 1 s |
| Detection Method | Time-Correlated Single Photon Counting (TCSPC) |
| Wavelength Selection | Filter-based (monochromator optional) |
| Detector Type | PPD (Photon-Counting Photodiode) Module |
| Software | Horiba FluoroLog®-3 compatible analysis suite |
| Compliance | Designed for GLP/GMP environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | T64000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Resolution (Additive Mode) | 0.15 cm⁻¹ |
| Low-Wavenumber Limit (Subtractive Mode) | 5 cm⁻¹ |
| Focal Length (Single Stage) | 640 mm |
| Total Focal Length (Triple Additive) | 3 × 640 mm |
| Excitation Range | UV–VIS–NIR |
| Detector | Research-Grade Air-Cooled Large-Format CCD |
| Optical Output | Flat-Field Spectral Dispersion |
| Laser Power Control | Multi-Step Attenuation Wheel |
| Configuration Options | Confocal Microscopy & Macro Sample Chamber |
| Polarization Compatibility | Full-Line (Excitation, Raman, White Light) |
| Optional Detectors | Secondary Output Port for PL or NIR Raman |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ToupH™ Series (e.g., 9615-10D, 9625-10D, 0040-10D) |
| Temperature Range | 0–100 °C (glass) |
| pH Range | 0–14 (standard) |
| Construction | Composite glass or ISFET sensing element with integrated temperature sensor and double-junction reference system |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <791>, and GLP/GMP environments requiring traceable calibration and stable long-term drift performance |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Import Status | Imported |
| Model | Tunable PowerArc / Tunable KiloArc |
| Output Power (Tunable PowerArc) | Up to 20 mW (wavelength-, grating-, and bandwidth-dependent) |
| Output Power (Tunable KiloArc) | >300 mW (wavelength-, grating-, and bandwidth-dependent) |
| Beam Divergence | 14.5° (PowerArc) / 14.4° (KiloArc) |
| Numerical Aperture (N.A.) | 0.12 |
| Optical Noise | 0.07% RMS |
| Power Stability | ±0.2% (over 8 hours, temperature-controlled environment) |
| Spectral Range | 180–2200 nm |
| Bandwidth Tunability | 0–25 nm (continuously adjustable) |
| Lamp Options | 75 W to 1000 W Xenon arc lamps |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | U-50 Portable |
| Instrument Type | Multiparameter |
| Parameter Count | 11 |
| pH Range | 0–14 |
| pH Resolution & Accuracy | 0.01 pH |
| ORP Range | −2000 to +2000 mV |
| DO Range | 0–50.0 mg/L |
| DO Resolution | 0.01 mg/L |
| Conductivity Range | 0–10 S/m |
| Turbidity Methods | LED forward scatter (U-53), tungsten lamp 90° scatter (U-53G), LED 90° scatter (U-54) |
| Turbidity Resolution | 0.01 NTU (0–10 NTU range) |
| Depth Measurement | up to 30 m (pressure-based, optional on U-52G/U-53G/U-54G) |
| Temperature Range | −10 to 55 °C |
| IP Rating | IP67 (host), IP68 (probe) |
| Battery Life | up to 70 h (alkaline AA ×4, backlight off) |
| Data Storage | 10,000 sets |
| Communication | USB |
| Calibration | 2-point pH (pH 4.01/7.00/9.18 buffers), multi-point turbidity/conductivity |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ultima Expert |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Not Specified |
| Precision (RSD) | ≤1% |
| Long-Term Stability (RSD) | ≤2% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | ≤0.005 nm at 200 nm (Constant Resolution Across Full Range) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Ultima Expert |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Not Specified |
| Repeatability | ≤1% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 160–800 nm |
| Optical Resolution | ≤0.005 nm (5 pm) |
| Detector | High-Density Diode (HDD) Array |
| Grating Options | 2400 g/mm holographic grating (≤5 pm @ 120–320 nm |
| Grating Size | 110 × 110 mm ion-etched holographic grating |
| Stray Light Level | <1 × 10⁻⁷ |
| Monochromator | Czerny-Turner with 1 m focal length |
| Plasma Observation | Vertical torch with side-on viewing geometry |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | VS20 |
| Resolution | ≤6.5 nm (with 50 µm slit) |
| Stray Light | <0.25% @ 260 nm, <0.1% @ 400 nm, <0.2% @ 600 nm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-1000WR/1700WR |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-1700 |
| Price Range | USD 42,000–70,000 |
| Instrument Type | Scanning |
| X-ray Tube Power | Not Applicable (Rh anode, max 50 kV / 1 mA) |
| Elemental Range | Na to U |
| Detection Limits | Cd ≤ 2 ppm, Pb ≤ 5 ppm, Cl ≤ 50 ppm |
| Sample Chamber Max Size | 460 × 360 × 150 mm |
| X-ray Beam Diameters | Φ1.2 mm and Φ3.0 mm (motorized switching) |
| Detector | High-Purity Silicon XEROPHY Detector |
| Liquid Nitrogen Capacity | 3 L |
| LN₂ Consumption | <1 L/day (only during operation) |
| Optical Magnification | 50× (coaxial with X-ray beam) |
| Software | Automated qualitative/quantitative analysis (fundamental parameters method, calibration curve method, single-point correction) |
| PC Requirements | Pentium IV ≥1.8 GHz, ≥1 GB RAM, ≥120 GB HDD, Windows XP, 17″ monitor, color inkjet printer |
| Ambient Temp | 10–35 °C (optimal), 5–40 °C (operational) |
| Humidity | ≤80% RH at 5–31 °C |
| Power Supply | AC 100/120/220/240 V ±10%, 50/60 Hz |
| Power Consumption | ≤1.3 kVA (system-wide) |
| Weight | ~265 kg (analysis unit only) |
| Dimensions | Analyzer Unit: 610(W) × 750(D) × 500(H) mm |
| Signal Processing Unit | 220(W) × 500(D) × 480(H) mm |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-5200 |
| Price Range | USD 42,000–70,000 (FOB) |
| Instrument Type | Scanning Micro-XRF |
| X-Ray Tube Power | 50 kV / 1 mA |
| Target Material | Rhodium (Rh) |
| Detectable Elements | Na (Z=11) to U (Z=92) |
| Primary Beam Spot Sizes | 10, 50, 100, 400 µm, 1.2 mm, 3 mm |
| Detector | Silicon Drift Detector (SDD) |
| Sample Stage | 100 × 100 mm (standard), up to 200 × 200 mm (optional) |
| Sample Chamber Dimensions | 400 × 350 × 40 mm (customizable) |
| Optical Imaging | Macro-view 100 × 100 mm (400K pixels standard |
| Analysis Modes | Qualitative (auto-identification, ROI color mapping, background subtraction, spectral matching) and Quantitative (Fundamental Parameters Method, calibration curve, Cl/thickness/wire compensation) |
| Data Export | Excel®-compatible reporting module |
| Power Supply | AC 100/120/220/240 V, 50/60 Hz |
| Weight | ~280 kg |
| Dimensions (W×D×H) | 680 × 833 × 670 mm |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-5200WR |
| Sample Environment | Air (Atmospheric) |
| Elemental Range | Na to U |
| Quantification Range | 1 ppm – 99.99% |
| Operating Conditions | 50 kV / 1 mA |
| Repeatability | ±0.1% RSD |
| Spot Size | Standard 400 µm, Optional 10 µm |
| Detector | Silicon Drift Detector (SDD), LN2-free |
| Geometry | Coaxial Optical Microscope Integration |
| Analysis Mode | Non-destructive, No Vacuum Required, No Sample Preparation |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-7000V |
| Detector | Silicon Drift Detector (SDD) |
| X-ray Source | Rh anode, 50 kV / 1 mA |
| Spatial Resolution | Down to 10 µm |
| Measurement Range | Na (11) to U (92) |
| Vacuum Modes | Full vacuum & local vacuum (switchable in <5 s) |
| Optical Imaging | Co-axial CCD with macro/micro view |
| Sample Chamber | 300 mm × 300 mm × 80 mm (full vacuum), XY stage: 100 mm × 100 mm |
| Software | SmartMap™ for hyperspectral mapping, INCA™ pulse processor, GLP-compliant data handling |
| Quantification Methods | Fundamental Parameters (FP), single-standard FP, calibration curve, multilayer thin-film analysis (nm–µm scale) |
| Elemental Mapping | Pixel-resolved full-spectrum acquisition, offline reprocessing, RGB overlay, line scan, ROI masking |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XGT-7200 |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Scanning Micro-XRF |
| X-ray Tube Power | Not Applicable (Microfocus Rh Target, Fixed Excitation) |
| Elemental Range | Na (11) to U (92) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | XGT-7200WR |
| Detection Principle | Energy Dispersive X-Ray Fluorescence (ED-XRF) |
| Spot Size Range | 10 µm to 1.2 mm |
| Detector Type | Silicon Drift Detector (SDD), Liquid-Nitrogen-Free |
| Maximum Scan Area | 10 cm × 10 cm |
| Optical-Element Image Co-Registration | Yes |
| Elemental Mapping Resolution | ≤10 µm |
| Compliance | ASTM E1621, ISO 8256, IEC 62321-5 (RoHS), USP <232>/<233>, GLP/GMP-ready data audit trail |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XGT-9000 |
| Excitation Mode | Single-Wavelength Excitation |
| X-ray Tube Power | 50 W |
| Voltage Range | Up to 50 kV |
| Current Range | Up to 1000 µA |
| Elemental Coverage | Na (11) to U (92) |
| Minimum Spot Size | ≥10 µm |
| Optional Capillary Probes | 15 µm and 100 µm |
| Detector Configuration | Dual-mode — Energy-Dispersive XRF + Transmission X-ray Imaging |
| Sample Chamber Flexibility | Up to 4 configurable measurement atmospheres (air, He, vacuum, N₂) |
| Software Platform | HORIBA X-RAY LAB |