| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Baijiu (Chinese Liquor) Analysis |
| Temperature Control Range | 20 °C to 450 °C |
| Temperature Ramp Rate | 0.1–80 °C/min |
| Cooling Rate | Up to 39.9 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01 °C |
| Minimum Temperature Increment | 1 °C |
| Programmable Temperature Program | Multi-step (≥8 stages) |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Injector Options | Packed column, capillary column, 6-port gas valve, automatic thermal desorption, purge-and-trap, and headspace sampling |
| Detector Capacity | Up to 3 detectors simultaneously |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | Baijiu-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Clinical Toxicology & Forensic Medical Testing |
| Temperature Control Range | Ambient + 5°C to 400°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Cool-down Time | ~6 min (from 450°C to 50°C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Temperature Accuracy | ±0.01°C |
| Max Programmed Ramp Stages | 16 |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 simultaneous detectors (FID, TCD, ECD, FPD, NPD configurable) |
| Injector Options | Packed column, capillary column, 6-port gas valve, automated headspace, purge-and-trap, thermal desorption |
| Software | Dual-language (English/Chinese) GC workstation with audit trail, method validation support, and CFR Part 11–compliant data integrity features |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry Dedicated |
| Column Oven Temperature Range | Ambient + 5°C to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | 400°C to 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | HuaShengPuXin/HSPX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | LPG-Dedicated |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-down Rate | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC-BA1000 |
| Price Range | USD 4,200–7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Beverage Quality Control & Regulatory Compliance |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gaseous Oxygen & Liquid Oxygen Analysis |
| Temperature Control Range | 4 °C above ambient to 450 °C |
| Oven Ramp Rate | 0.1–39 °C/min (standard) |
| Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Mine Safety & Gas Monitoring) |
| Oven Temperature Range | Ambient +12 °C to 400 °C |
| Oven Ramp Rate | 0.1–39 °C/min (Standard) |
| Oven Cooling Rate | ~6 min from 450 °C to 50 °C |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detectors | TCD (MDL ≤9×10⁻⁶ mg/mL in H₂, n-C₁₆), FID (MDL ≤8×10⁻¹² g/s, n-C₁₆), ECD (MDL ≤0.1 pg, γ-BHC), FPD ([P] ≤1×10⁻¹² g/s, TBP |
| Column Configuration | Packed-column system with methanizer and automated 6-port valve for simultaneous O₂/N₂/CH₄/CO/CO₂ analysis |
| Detection Ranges | O₂ (20.9±5%), N₂ (78±10%), CH₄ (0.5 ppm–10%), CO (0.5 ppm–0.3%), CO₂ (1 ppm–0.5%), C₂H₆/C₂H₄/C₂H₂ (1 ppm–0.3%) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 1650 W |
| Net Weight | ~50 kg |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China-made) |
| Model | Formaldehyde Dimethyl-Specific Gas Chromatograph |
| Price Range | USD 4,200 – 7,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Solvent Purity Analysis & Quality Control |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | From 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–60 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Oven Temperature Range | Ambient +5°C to 400°C |
| Temperature Ramp Rate | 0.1–40°C/min |
| Cooling Rate | 400°C → 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Sensitivity | ≥3000 mV·mL/mg (benzene) |
| TCD Baseline Drift | ≤3% of full scale per hour |
| Column | 3 mm ID × 6 m stainless steel packed column |
| Injection Mode | 6-port gas sampling valve |
| Display & Control | Microprocessor-controlled with backlit LCD and Chinese-language keypad |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC3000 |
| Price Range | USD 7,000 – 14,000 (FOB China) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Pump Type | Dual-Piston Reciprocating High-Pressure Solvent Delivery System (P3000 Series) |
| Detector Type | UV/VIS Absorbance Detector (UV3000) |
| Display | 320 × 240 dot-matrix LCD with adjustable blue backlight |
| Control Modes | Standalone front-panel operation & RS232 serial interface |
| Power Supply | 220 V ±10%, 50 Hz, 400 W (pump) |
| Dimensions (D×H×W) | 398 × 149 × 267 mm |
| Weight | 14 kg |
| GLP Data Logging | Lamp operating time, lamp ignition count, lamp replacement history, and instrument serial number |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3600A |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Sample Tray Capacity | ≥30 positions |
| Trap Tube Temperature Range | Ambient to 350 °C |
| Sample Heating Temperature Range | Ambient to 90 °C |
| Water Trap Temperature Range | Ambient to 200 °C |
| Valve & Transfer Line Temperature Range | Ambient to 250 °C |
| Desorption Ramp Rate | >2000 °C/min |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity Gradient | < ±1 °C |
| Vial Format | 40 mL |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-3900A |
| Sample Tray Capacity | 84 positions |
| Temperature Control Accuracy | ±0.1°C |
| Trap Desorption Temperature Range | 100–350°C |
| Sample Heating Temperature (Purge Vessel) | up to 250°C |
| Sample Vial Cooling Temperature Range | 0–40°C |
| Water Removal Trap Temp Range | Ambient–200°C |
| Valve & Transfer Line Temp Range | Ambient–250°C |
| Trap Cryo-Focusing Temp Range | 0–40°C |
| Sample Oven Temp Range | Ambient–90°C |
| Hot Water Bath Temp Range | Ambient–90°C |
| Purge Tube Temp Range | Ambient–90°C |
| Desorption Ramp Rate | >2000°C/min |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PT-4000 |
| Sample Tray Capacity | 100 positions |
| Injection Precision | RSD < 1% |
| Trap Temperature Range | Ambient to 350 °C |
| Sample Heating Temperature Range (Purge Zone) | Ambient to 90 °C |
| Application Class | Water and Soil VOC Analysis |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ATDS-3600A |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Desorption Temperature Range | −30 °C to 400 °C |
| Cold Trap Temperature Range | −30 °C to 50 °C |
| Desorption Recovery Rate | >95% |
| Sample Capacity | 20 positions |
| Temperature Control Accuracy | <±0.1 °C |
| Heating Ramp Rate | >2000 °C/min |
| Carrier Gas Flow | 0–400 mL/min (continuously adjustable) |
| Dimensions | 450 × 360 × 510 mm |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ADHS-8890A |
| Sample Capacity | 20 positions |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Chilled Vial Temperature Range | 4–10 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Water Removal Trap Range | Ambient to −30 °C |
| Desorption Ramp Rate | >250 °C/min |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–500 mL/min |
| Tubing & Line Heating Range | Ambient to 250 °C |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 500×400×650 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ADHS-8890B |
| Instrument Type | Water & Soil Integrated Purge-and-Trap System |
| Sample Tray Capacity | 20 positions |
| Injection Precision | RSD < 10% |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Vial Cooling Range | 4–10 °C |
| Cold Trap (Desorption) Range | Ambient to –40 °C |
| Water Removal Trap Range | Ambient to –30 °C |
| Desorption Ramp Rate | >250 °C/min (low-voltage safe design) |
| Transfer Line & Valve Block Temp | Ambient to 250 °C |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–500 mL/min |
| Trap Tube Materials | Stainless steel / Quartz / Fused silica capillary (customizable) |
| Adsorbent Options | Custom-fill available |
| Programmable External Events | 7 channels |
| Timing Resolution | 0.1–99 min (timing accuracy <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa |
| System Pressure Rating | >0.4 MPa |
| Analytical Repeatability (GC-coupled) | RSD < 2.5% |
| Power Consumption | <1000 VA |
| Trigger Signal Latency | <2 s |
| Dimensions (H×W×D) | 500 × 400 × 650 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AFS-100 |
| Detection Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Linear Range | Dual-channel ≥ 0.999 |
| Detection Limit | Dual-channel ≤ 0.03 ng/mL |
| Atomizer Temperature Control Range | 15–30 °C |
| Operating Ambient Temperature | 15–30 °C |
| Relative Humidity | ≤75% |
| Argon Supply Pressure | 0.2–0.3 MPa (regulated to 0.2 MPa) |
| Alarm Threshold | <0.15 MPa |
| Power Supply | 220 V ± 22 V AC |
| Host Power Consumption | ≤400 W |
| Warm-up Time | 30 min |
| Repeatability | Dual-channel ≤1% |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-20 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Loop Volume | 20 mL standard |
| Temperature Control Stability | ±0.5 °C |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-50 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 50 positions |
| Vial Size Compatibility | 10 mL and 20 mL standard crimp-top vials |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| External Event Control Channels | 15 |
| Timing Resolution | 0.1–99 minutes (timing error <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Heated Incubation Zones | 4 independent zones |
| Repeatability | RSD <1% (dependent on GC system performance and operator technique) |
| Power Requirement | <1000 VA |
| Trigger Signal Output Latency | <2 s |
| Dimensions (H×W×D) | 580 × 564 × 666 mm |
| Net Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-6890S |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 9 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 350 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C (1 °C increment) |
| Temperature Accuracy | < ±0.5 °C |
| Pressure Control Range | 0–0.2 MPa (up to 0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Dimensions | 260 × 360 × 420 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-8890 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C / Ambient to 150 °C (1 °C increment) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Pressurization Range | 0–0.2 MPa (0–0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Dimensions (W×D×H) | 570 × 330 × 265 mm |
| Weight | ~25 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430 |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 1 tube per run |
| Carrier Gas Flow | 0–100 mL/min (adjustable, with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Timing Resolution | 0.1–99 min (timing error <0.1%) |
| Programmable External Events | 15 |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430S |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery Rate | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 30 tubes |
| Programmable Events | Up to 15 |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, digital indication) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Trigger Signal Output Delay | <2 s |
| Dimensions (H×W×D) | 470×490×450 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Secondary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment, >3000 °C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40 °C (±1 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Sample Capacity | 1 tube per run |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, visual indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Tube Materials | Stainless steel, quartz glass, fused silica capillary (optional) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment |
| Secondary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate |
| Cold Trap Temp Range | Ambient to –40°C (ambient-dependent), ±1°C accuracy, 1°C increment |
| Valve & Transfer Line Temp Range | Ambient to 260°C, ±1°C accuracy, 1°C increment |
| Sample Capacity | 30 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S-II |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to –40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy, 1°C increment) |
| Sample Capacity | 40 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (system-dependent, GC and operator performance included) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-4133 |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy) |
| Sample Pathway Temp Range | Ambient to 200°C (±1°C accuracy) |
| Sample Capacity | 50 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% |
| Tube Material | Stainless steel |
| Trap Options | Stainless steel, quartz glass, or fused silica capillary |
| Carrier Gas Flow | 0–100 mL/min (adjustable with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 500 × 485 × 650 mm |
| Weight | ~45 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-51 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | 50–380 °C |
| Secondary Desorption Temperature Range | 150–380 °C |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Peak Width (FWHM) | < 3 s |
| Desorption Efficiency | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Sample Capacity | 51 positions |
| Compliance | Designed for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | CAAM-2001C |
| Detection Elements | Na, K, Mg, Ca, Cr, Mn, Fe, Co, Ni, Pt, Au, Cu, Ag, Zn, Cd, Pb, Bi, Li |
| Detection Limit | 0.002 µg/mL (for Cu) |
| Atomizer Temperature Control Range | +15 °C to +35 °C |
| Grating | 1800 lines/mm |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0 nm (auto-selectable) |
| Wavelength Accuracy | ±0.15 nm |
| Baseline Drift (static) | ≤±0.002 A/30 min |