Chemical Analysis Instruments
Filter
Showing 391–420 of 4239 results
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AL-ICP9090 |
| Pricing | Upon Request |
| Brand | Ailun General |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | AULUN-H9886 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal |
| Pump Pressure Range | 0–42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 0–35 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | YC9000 Enhanced |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Pump Pressure Range | 0–37 MPa (0–5000 psi) |
| Flow Rate Range | 0.00–9.99 mL/min |
| Eluent Flow Rate | 0.1–3.0 mL/min |
| Maximum Operating Pressure | 21 MPa (3000 psi) |
| Column Oven Temperature Range | 30–60 °C (86–140 °F) |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | ICP-MS9800 |
| Pricing | Upon Request |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | YC-9000 |
| Price | ¥800,000 CNY |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-purpose Ion Analysis |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | YC3000 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Pressure Range | 0–42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate (Typical) | 1.5 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 0–65 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–60 mM |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | YC3080 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal Anion/Cation Analysis |
| Pump Pressure Range | 0–42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 42 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detection Range | μg/L to mg/L |
| Conductivity Detector | Digital Microprocessor-Controlled |
| Conductivity Range | 0–15,000 µS/cm |
| Resolution | 0.0012 nS/cm |
| Cell Material | Titanium |
| Column | Patented AJS-80 (Anion-Specific) |
| Software | Full-Featured Chinese GUI with Peak Recognition Algorithms (Solvent Peaks, Tailing Peaks, Shoulder Peaks, Artifacts) |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | YC7000 |
| Price | ¥250,000 |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Range | 0–42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | YC7060 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Pressure Range | 0–42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 42 MPa |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detector Options | Conductivity, UV, Electrochemical |
| Sample Introduction Modes | Manual, Motorized, Autosampler-Integrated |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YC9000 |
| Price Range | USD 70,000–100,000 (FOB Qingdao) |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal |
| Pump Pressure Rating | 0–37 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.1–5.0 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YC9000 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal Ion Analysis |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YC988 |
| Instrument Type | Portable |
| Application Scope | General-purpose |
| Pump Pressure Range | 0–25 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate (Typical) | 1.5 mL/min |
| Maximum Operating Pressure | 25 MPa |
| Operating Temperature Range | 0–35 °C |
| Temperature Reproducibility | ±10 °C |
| Eluent Concentration Range | 0.1–60 mM |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | YC988 |
| Instrument Type | Portable |
| Application Scope | General-purpose |
| Pump Pressure Range | 0–25 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate (Typical) | 1.5 mL/min |
| Maximum Operating Pressure | 25 MPa |
| Operating Temperature Range | 0–35 °C |
| Temperature Reproducibility | ±10 °C |
| Eluent Concentration Range | 0.1–60 mM |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | EDU3 |
| Product Type | Olfactory Analysis System (Electronic Nose) |
| Adsorbent Compatibility | Multiple proprietary sorbents |
| Sample Flow Rate | 0.2–0.5 L/min (programmable) |
| Sample Temperature Range | 30–100 °C (adjustable) |
| Desorption Flow Rate | 50–100 mL/min (adjustable) |
| Desorption Temperature | >250 °C (adjustable) |
| Injection Port Temperature | >150 °C (heated transfer line) |
| Enrichment Factor | 10–1,000× (compound- and time-dependent) |
| Interface Compatibility | PEN3 electronic nose, GC, GC-MS, MS |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | HT2000 |
| Sample Tray Capacity | 14-position or 42-position (selectable) |
| Heating Temperature Range | Off / 40–170 °C |
| Heating Time | Off / 0–999 min |
| Vibration Mode | Oscillatory agitation |
| Vibration Cycle | Off / 0–9.9 min |
| Sample Analysis Time | 0–60 min |
| Dimensions (H×W×D) | 696 × 330/350 × 320/520 mm (door open/closed |
| Power Supply | 100–240 V AC, 50–60 Hz, 1.6 A |
| Weight | 10 kg |
| Brand | AIRSENSE |
|---|---|
| Origin | Imported |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FTIR) |
| Model | MI10 |
| Wavenumber Range | 500–5000 cm⁻¹ |
| Spectral Resolution | 2 cm⁻¹ |
| Compliance | Designed for field-deployable chemical identification in accordance with ISO 17025-aligned operational workflows |
| Software | Embedded real-time spectral acquisition and library-matching interface |
| Data Handling | On-device storage with USB export and optional cloud-sync capability |
| Environmental Rating | IP54-rated enclosure for dust and splash resistance |
| Power Supply | Rechargeable Li-ion battery (≥4 h continuous operation) |
| Dimensions & Weight | 320 × 240 × 120 mm |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Type | Olfactory Analysis System (Electronic Nose) |
| Sensor Technology | Metal Oxide Semiconductor (MOS) Array |
| Data Acquisition | Standalone Operation with Onboard LCD Display & Internal Data Storage |
| Sampling Modes | Manual, Automated Headspace, Adsorption-Desorption Gas Interface, Optional Pre-concentration Unit |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Models | TS-5000Z (Electronic Tongue), PEN3 (Electronic Nose) |
| Application | Odor and Taste Profiling, Quality Control, Process Monitoring, Sensory Fingerprinting |
| Detection Principle | Multi-channel Biomimetic Lipid Membrane Sensors (TS-5000Z) |
| Sensitivity | Sub-ppb (PEN3), Quantitative Taste Index Resolution (TS-5000Z) |
| Compliance | Designed for GLP-compliant workflows |
| supports ASTM E2897-21 (Standard Guide for Electronic Nose Data Acquisition and Analysis) and ISO 22964 | 2021 (Electronic Tongues — Performance Requirements and Test Methods) |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | AISA Eagle, AISA Hawk, AISA Dual |
| Spectral Range | 400–970 nm (Eagle), 970–2450 nm (Hawk), 400–2450 nm (Dual) |
| Spatial Pixels | 512 or 1024 (Eagle), 320 (Hawk and Dual) |
| Spectral Bands | 488 (Eagle), 256 (Hawk), 500 (Dual) |
| Frame Rate | 160 Hz (Eagle), 100 Hz (Hawk and Dual) |
| Weight | < 12 kg (system total) |
| Integration | GPS/INS-aided georeferencing module included |
| Data Acquisition | Real-time onboard storage with lossless compression |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AisaFENIX |
| Pricing | Upon Request |
| Brand | Aisida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XG6000 |
| Pricing | Upon Request |
| Brand | Aisite/ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DM2400 |
| Price Range | USD 42,000–70,000 |
| Form Factor | Benchtop/Floor-Standing |
| Industry Application | Energy & Petrochemicals |
| Elemental Range | F (Z=9) to Cl (Z=17) |
| Quantification Range | 1 ppm – 10 wt% |
| Energy Resolution | <135 eV (Mn Kα) |
| Repeatability (S) | 0.3 ppm (RSD ≤ 2.7% at 1 ppm S level) |
| Brand | Aist / ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DM1230 |
| Configuration | Benchtop |
| Industry Application | Cement, Energy & Chemicals |
| Elemental Analysis Range | Al₂O₃, SiO₂ |
| Concentration Range | 0.01%–100% (w/w) |
| Energy Resolution | ≤18% at Mn Kα (5.9 keV) |
| Repeatability | σ(Al₂O₃) ≤ 0.07%, σ(SiO₂) ≤ 0.07% (n=11, cement raw meal) |
| Detector | Thin-Be-window gas-flow proportional counter |
| X-ray Source | Low-power microfocus tube (≤10 kV, ≤0.5 mA, ≤5 W) |
| Measurement Time | 100–300 s (user-selectable |
| default | 300 s) |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Brand | Aist / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM2100 |
| Form Factor | Benchtop |
| Industry Application | Cement & Energy Chemicals |
| Elemental Range | Si, Al, S, Ca, Fe |
| Concentration Range | 0.01% – 99.99% |
| Energy Resolution | 16% (at Mn Kα) |
| Repeatability (RSD) | ≤0.20% |
| Detector | Thin-Be-window Proportional Counter |
| X-ray Tube | ≤10 kV, ≤0.5 mA, ≤5 W |
| Measurement Time | 1–999 s (default 310 s) |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Radiation Status | Exempted per National Radiation Safety Authority (First EDXRF instrument in China granted exemption) |
| Brand | Aist (ST) |
|---|---|
| Model | DM2500 |
| Element Range | B (Z=5) to Zn (Z=30) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <129 eV (Mn Kα) |
| Repeatability | ≤0.3 ppm (S, typical) |
| Detector | Silicon Drift Detector (SDD), 20 mm² active area, AP3.3 polymer window |
| X-ray Source | 50 W microfocus Ag-target tube with thin Be window, optimized kV/mA/target combination |
| Excitation Method | Multiple Monochromatic Excitation (MMEDXRF) using Logarithmic Spiral Doubly Curved Crystal (LSDCC) and Ge secondary target |
| Sample Geometry | Downward-beam configuration with sample rotation |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Form Factor | Benchtop |
| Regulatory Status | Radiation-exempt design per national safety standards |
| Brand | Aist / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM2300 |
| Configuration | Benchtop / Floor-standing |
| Analytical Range | Cl (Z=17) to U (Z=92) |
| Detection Limit | ≤2 ppm (for Pb, Cd, Hg, Cr, Br, Cl) |
| Measurement Time | 300 s (typical) |
| X-ray Tube | 0–50 kV, 0–1 mA (continuously adjustable) |
| Collimators | Ø1 mm, Ø3 mm, Ø5 mm, Ø7 mm (motorized auto-switching) |
| Filters | 4-position motorized filter wheel |
| Detector | High-resolution silicon PIN diode |
| Energy Resolution | ≤155 eV at Mn Kα (5.9 keV) |
| Sample Chamber | 480 × 350 × 125 mm (L×W×H) |
| Operating Environment | 5–30 °C, RH ≤80% @ 25 °C, 220 ±20 V, 50 Hz |
| Power Consumption | ≤150 W |
| Dimensions | 503 × 412 × 478 mm |
| Weight | 45 kg |
| Brand | Aist (ST) |
|---|---|
| Model | DM8000 |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 400 W |
| X-ray Tube | Varian EG-60 thin Be-window, Rh anode |
| Detectable Elements | Any 10 elements from Na (11) to U (92) |
| Detector Window | Moxtek ProLINE 0.6 µm polyimide |
| Detector Linear Range | 500 kcps |
| Be Window Thickness | 75 µm |
| Compliance | GB/T 176–2017, JC/T 1085–2008, JB/T 11145–2011 |
| Brand | AIWEI |
|---|---|
| Origin | Tianjin, China |
| Model | 30kW Fuel Cell Stack Test Station |
| Instrument Type | Electrochemical Workstation |
| Current Range | 0–1500 A |
| Power Rating | 30 kW (DC output) |
| Electronic Load Capacity | 36 kW (optional) |
| Voltage Range | 0–400 V DC |
| AC Input | Three-phase 220/380 VAC, Max 150 A |
| Dimensions (W×D×H) | 1300 × 2500 × 2000 mm |
| Mass Flow Control | Anode (H₂/N₂) up to 500 SLPM |
| Humidification | Direct-injection humidifier with temperature-controlled heating chamber & pressure pump |
| Backpressure Control | 0–3.5 bar, proportional control, ΔP < 2 kPa at max flow |
| Cooling System | 100 L water reservoir, 0–95 °C heating/cooling, conductivity monitoring |
| Software Platform | LabVIEW-based real-time control & data acquisition, ASTM/ISO-compliant test sequencing, FDA 21 CFR Part 11-ready audit trail (optional) |
| Brand | AIWEI |
|---|---|
| Model | 50–200 kW Electrochemical Workstation |
| Type | Regenerative/Energy-Dissipative Stack Test System |
| Power Range | 50–200 kW |
| Current Range | ±1000 A / ±1500 A |
| Voltage Range | 0–400 V / 0–600 V / 0–800 V |
| Enclosure Dimensions | 1500(W) × 3300(D) × 2000(H) mm |
| Input Power | 3-phase 220 VAC or 380 VAC, up to 200 A |
| Anode Gas Flow Control | H₂/N₂, up to 2000/4000 SLPM |
| Cathode Gas Flow Control | Air/N₂, up to 6000/12000 SLPM |
| Humidification | Direct-injection humidifier with temperature-controlled heating chamber & pressure pump |
| Backpressure Control | 0–3.5 bar, proportional control, ΔP < 2 kPa at max flow |
| Cooling/Heating | 100 L water reservoir, 20–95 °C temperature range, conductivity monitoring |
| DI Water System | Integrated deionization filtration with auto-regeneration |
| Condensate Management | Automated drainage with heat-exchange cooling loop |
| Preheater | SUS 316 tubing (anode: 1.5", cathode: 2"), inline gas temperature control |
| Data Acquisition | LabVIEW-based platform with DAQ integration, real-time visualization, automated protocol execution, load-following control, and customizable test sequencing |
| Optional Modules | Individual cell voltage monitoring (±5 V per cell), multi-channel EIS (10 mHz–10 kHz), HFR/IR drop analysis, combined IV + EIS operation |
| Brand | AIWEI |
|---|---|
| Model | 7–10 kW Fuel Cell Stack Test Station |
| Category | Electrochemical Workstation |
| Power Rating | 7–10 kW |
| Current Range | ±600 A / ±1000 A |
| Voltage Range | 0–60 V / 0–120 V / 0–400 V (configurable) |
| Cooling | Liquid-cooled electronic load modules (9 kW / 12 kW) |
| Enclosure | Floor-standing modular cabinet (1100 W × 1800 D × 2000 H mm) |
| Input Power | 3-phase 220 VAC or 380 VAC, max. 75 A |
| Anode Gas Flow Control | H₂/N₂, up to 150 SLPM |
| Cathode Gas Flow Control | Air/N₂, up to 500 SLPM |
| Humidification | Bubble-type or membrane-type humidifiers with temperature-controlled water bath, liquid-level monitoring, wet/bypass mode |
| Water Management | Automated DI-water injection, 50 L thermal reservoir with heating (up to 95 °C) and cooling, conductivity monitoring, integrated deionization filtration |
| Backpressure Control | 0–3.5 bar, proportional pressure regulation, ΔP < 2 kPa at max flow, differential pressure control for anode/cathode inlet/outlet |
| Preheater | SUS316 tubing (anode: 1/2″, cathode: 3/4″), inline gas temperature control |
| Condensate Handling | Auto-drain water traps with heat sink & fan cooling |
| Software | LabVIEW-based control suite with real-time DAQ, automated test protocols (load-following, polarization, EIS), GLP-compliant audit trail (optional), FDA 21 CFR Part 11 ready (with optional digital signature module) |
| Optional Modules | Individual cell voltage monitoring (±5 V per cell, channel-selectable), multi-channel EIS (10 mHz–10 kHz), HFR/IR/Ohmic resistance extraction, stack discharge resistive load bank (1–2 kW) |
