Chemical Analysis Instruments
Filter
Showing 331–360 of 10547 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Quadrupole Mass Spectrometer (Single Quadrupole) |
| GC Compatibility | Agilent 6890 Series GC |
| Mass Range | Up to 1050 u |
| Ion Source | Inert, Temp-Controlled to 350 °C |
| Ionization Modes | Electron Ionization (EI) and Chemical Ionization (CI) with AutoCI |
| Scan Speed | Up to 4.8 scans/sec (typical) |
| Resolution | Unit mass resolution (R = 1000, 10% valley) |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI full-scan mode (S/N ≥ 20:1) |
| Data System | MSD ChemStation (G1701DA) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 1.6–800 u (amu) |
| Mass Accuracy | ±0.1 u |
| EI Sensitivity | ≥20:1 S/N for 1 pg OFN at m/z 272 (Full Scan) |
| SIM Sensitivity | ≥10:1 S/N for 20 fg OFN at m/z 272 |
| PCI Sensitivity | ≥75:1 S/N for 100 pg Benzophenone at m/z 183.1 |
| NCI Sensitivity | ≥500:1 S/N for 1 pg OFN at m/z 272 |
| Ion Source | Electron Ionization (EI), Chemical Ionization (CI), and Negative Chemical Ionization (NCI) capable |
| Ion Source Material | Molybdenum alloy, temperature-controlled |
| Quadrupole | Gold-coated quartz, hyperbolic rod set, heated and independently temperature-regulated |
| GC Oven Temperature Range | Ambient to 400 °C |
| Injector Types | Programmable Temperature Vaporizer (PTV) and Split/Splitless Capillary Injector |
| Mass Scan Modes | Full Scan, Selected Ion Monitoring (SIM), and Tuning |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Service Provider |
| Product Category | Imported Instrument |
| Model | 6890/7890/8890 Qualification Services |
| Price Range | USD 10,500–20,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Pharmaceutical Analysis |
| Oven Temperature Range | 0–500 °C |
| Oven Ramp Rate | 0–100 °C/min |
| Oven Cool-down Rate | 0–100 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Inlet Maximum Operating Temperature | 450 °C |
| Inlet Pressure Setting Range | 0–970 psi |
| Inlet Total Flow Setting Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N-5973N |
| Instrument Type | Single Quadrupole GC-MS System |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| MS Analyzer Type | Quadrupole Mass Filter |
| Mass Range | 1.5–650 u (nominal mass scale) |
| Resolution | Unit mass resolution (typical, 10% valley definition) |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in full-scan mode (m/z 272, S/N ≥ 10:1) |
| Scan Speed | Up to 6,400 Da/sec (full-scan, 0.1 sec/decade) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890N |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Instrument Type | Gas Chromatograph (GC) |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–50 µL |
| Oven Temperature Range | 10–60 °C |
| Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N-5973 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Mass Range | 1.6–800 amu |
| Resolution | Unit mass resolution (nominal) |
| EI Sensitivity | ≥20:1 S/N for 1 pg OFN at m/z 272 (full scan) |
| SIM Sensitivity | ≥10:1 S/N for 20 fg OFN at m/z 272 |
| Scan Speed | 11,000 amu/sec |
| Ion Source | Electron Ionization (EI), optional Chemical Ionization (CI) and Negative Chemical Ionization (NCI) |
| GC Oven Temperature Range | Ambient to 400 °C |
| GC Inlet Types | Programmable Temperature Vaporizing (PTV) inlet and split/splitless capillary inlet |
| Mass Spectrometer Operating Temperature | Independently controlled ion source and quadrupole (up to 350 °C) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N (GC) / 5973N (MSD) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Capillary Column Inlet with Electronic Pressure Control (EPC) |
| MS Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Negative Chemical Ionization (NCI) |
| Mass Range | 1.6–800 u |
| Mass Accuracy | ±0.1 u |
| EI Sensitivity | 1 pg OFN (m/z 272), S/N ≥ 20:1 (full scan) |
| 20 fg OFN (m/z 272), S/N ≥ 10 | 1 (SIM) |
| PCI Sensitivity | 100 pg di-tert-butyl methylamine (m/z 183.1), S/N ≥ 75:1 |
| NCI Sensitivity | 1 pg OFN (m/z 272), S/N ≥ 500:1 |
| Quadrupole | Gold-coated quartz, temperature-controlled, hyperbolic geometry |
| Ion Source | Molybdenum alloy, independently heated, inert surface finish |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GCMS 6890N-5973N |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1–1000 amu |
| Resolution | 1000–2000 (FWHM at m/z 272) |
| Sensitivity | >300:1 (S/N, EI mode, 1 pg octafluoronaphthalene, m/z 272) |
| Scan Speed | 15,000 u/s |
| Ionization Modes | Electron Impact (EI), Chemical Ionization (CI), Negative Chemical Ionization (NCI) |
| Injector Types | Split/Splitless and Programmable Temperature Vaporizing (PTV) inlets |
| Oven Temperature Range | Ambient to 400 °C |
| Mass Accuracy | ±0.1 u |
| Library | NIST 2008 Mass Spectral Library |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890PLUS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Time | ~6 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 7000E GC/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | Inert Plus EI Ion Source – IDL ≤ 4 fg (10 fg OFN injection) |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent Triple-Axis HED-EM with Extended-Life Electron Multiplier and Dynamically Ramped Iris |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | IDL ≤ 0.3 fg for 1 fg OFN injection |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent triple-axis high-efficiency dynamic electron multiplier (HED-EM) with extended-life EM and dynamically ramped iris aperture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 7100 |
| Instrument Category | Capillary Electrochromatography (CEC) |
| Sample Analysis Scope | Organic Compounds |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| GC Configuration | Conventional GC/MS |
| Mass Range | m/z 20–3000 |
| Resolution | >25,000 FWHM at m/z 271.9867, acquisition-rate independent |
| Sensitivity | IDL <60 fg for 100 fg OFN injection |
| Detector | Microchannel plate/scintillator/PMT with ADC electronics |
| Mass Accuracy | <2 ppm (1 pg OFN, m/z 271.9867) |
| Quadrupole Mass Range | m/z 20–1050 |
| Acquisition Rate | 1–50 spectra/sec, resolution-independent |
| Software Platform | Agilent MassHunter |
| GC Compatibility | Fully compatible with Agilent 8890/8860 GC systems and ZOEX thermal modulator for comprehensive 2D-GC (GC×GC) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7694 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | 15 °C above ambient to 220 °C (±1 °C accuracy) |
| Valve Heating Range | 15 °C above ambient to 220 °C (±1 °C accuracy) |
| Sample Loop Volumes | 0.5 mL, 1 mL, or 3 mL nickel tubing (user-selectable) |
| Vial Capacity | 44 positions |
| Vial Sizes | 10 mL and 20 mL standard |
| Brand | Agilent Technologies |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-manufactured under Agilent OEM/technology license) |
| Model | 7694E |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Up to 200 °C |
| Valve Temperature Control Range | Up to 200 °C |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 12 positions |
| Vial Size | 20 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7694E |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 15 °C above ambient to 200 °C (±1 °C) |
| Valve Heating Range | 15 °C above ambient to 200 °C (±1 °C) |
| Sample Loop Volume | 1 mL |
| Vial Capacity | 44 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Agilent 7697A |
| Sample Vial Capacity (Standard) | 111 positions, including 3 priority vial slots |
| Sample Vial Capacity (Optional) | 12-position configuration for academic or low-throughput labs |
| Vial Sizes Supported | 10 mL, 20 mL, and 22 mL vials without adapters |
| Injection Valve Loop Volume | Not specified in source data |
| Carrier Gas Compatibility | Hydrogen (H₂), Helium (He), Nitrogen (N₂) |
| Leak Detection | Automated, real-time vial pressure integrity check prior to analysis |
| Pressure Control | Independent headspace vial pressure and column head pressure regulation |
| Barcoding | Integrated sample vial barcode reader with LIMS-compatible data transmission |
| Method Transfer | Cross-platform method conversion and rapid re-optimization via Agilent Method Translation Software |
| Multi-HeadSpace Modes | Multiple Headspace Extraction (MHE) up to 100 cycles per vial |
| Vial Depressurization | Automatic post-analysis vial depressurization before return to tray |
| Interface | GC inlet-compatible transfer line kit for co-location with Agilent 7693A ALS on same GC inlet |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7700 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (Unit Mass Resolution, amu) | ≤ 0.8 |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 5, In ≥ 30, Bi ≥ 20 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | 7820 |
| Configuration | Single-Channel, FID-Detected System |
| Regulatory Compliance | Designed to meet ASTM D3606, ISO 10301, and USP <621> chromatographic method requirements |
| Software Platform | OpenLAB CDS (Compatible with 21 CFR Part 11-compliant configurations) |
| Detector Options | Flame Ionization Detector (FID), optional TCD or ECD available |
| Carrier Gas Compatibility | Helium, Hydrogen, Nitrogen |
| Column Compatibility | Capillary and packed columns (0.1–0.53 mm ID, up to 60 m length) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose Analytical Chemistry |
| Detector Options | FID, TCD, FPD Plus, NPD, µECD |
| Injector Types | Split/Splitless, Packed Column, Purge-and-Trap, Headspace |
| Valve Configuration | Up to 3 Valves |
| Control Architecture | Full Electronic Pressure Control (EPC) from Injector to Detector |
| Software Interface | Compatible with OpenLab CDS and Third-party Data Systems |
| Regulatory Alignment | Designed for GLP/GMP environments |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 8 °C to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Time | 999.99 min (maximum runtime) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 psi |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| Power Requirement | 220 V (±10%), 47.5–63 Hz, 1500 W (100 V: 2250 W) |
| Weight | 50 kg |
| Compliance | IEC/EN 61010, UL 61010, CSA C22.2 No. 61010, CISPR 11/EN 55011 Class A, ISO 9001 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7820A VL |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose analysis |
| Control System | Electronic Pressure Control (EPC) at inlet |
| Detector Regulation | Electronic Pressure Regulation (EPR) for FID |
| Included Configuration Options | SSL/EPC inlet + FID/EPR detector |
| Software | OpenLab CDS VL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.2–1 (adjustable) |
| Detection Limit (ng·L⁻¹) | ≤5×10⁻⁷ for low-mass elements, ≤1×10⁻⁷ for high-mass elements |
| Sensitivity (Mcps / mg·L⁻¹) | Li ≥ 80, Y ≥ 240, U ≥ 300 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7850 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 5–260 |
| Unit Mass Resolution (amu) | 0.5 |
| Detection Limit (ng·L⁻¹) | 10 |
| Sensitivity (Mcps / mg·L⁻¹) | 10 |
| Short-Term Stability (RSD %) | 3 |
| Long-Term Stability (RSD %) | 5 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | 7890 |
| Configuration | Dual Inlet / Triple Detector (FID, TCD, and Optional Third Detector) |
| EPC Channels | Up to 16 |
| Pressure Control Resolution | 0.001 psi |
| Retention Time Reproducibility | < 0.0008 min (RSD < 0.008%) |
| Peak Area Reproducibility | < 1% RSD |
| Oven Temperature Range | 35–450 °C |
| Oven Ramp Rate | Up to 120 °C/min |
| Column Flow Control Modes | Constant Pressure, Gradient Pressure (3-step), Constant Flow, Gradient Flow (3-step) |
| Data Output | Full-range digital signal (e.g., FID dynamic range: 10⁷) |