| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Specialty Gas Analysis |
| Oven Temperature Range | Ambient + 5 °C to 400 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | ≤9 min (350 °C → 50 °C) |
| Carrier Gas (He) Flow Range | 0–500 mL/min |
| Carrier Gas (He) Pressure Range | 0–500 kPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setting Range (He) | 0–100 kPa |
| Injector Total Flow Setting Range (He) | 0–500 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Temperature Control Range | Ambient to 450 °C (oven) |
| Ramp Rate | Up to 120 °C/min |
| Cool-down Rate | From 450 °C to 50 °C in <3.5 min |
| Carrier Gas Flow Range | 0–1200 mL/min (He, H₂, N₂) |
| Carrier Gas Pressure Control | 0–100 psi (EPC resolution: 0.001 psi) |
| Inlet Pressure Setting Range | 0–100 psi (split/splitless), 0–150 psi (high-pressure option) |
| Total Inlet Flow Setting Range | 0–1200 mL/min |
| Inlet Operating Temperature | Up to 450 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 450 °C to 50 °C (typical) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A GC / 5975C MSD |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate at 1 pg on-column injection |
| Scan Speed | 15,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 7890A-5975C |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (at 10% valley, peak width at half height) |
| Sensitivity | >300:1 (Signal-to-Noise Ratio, SIM mode, using octafluoronaphthalene) |
| Scan Speed | 15,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7890A-7000B |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1.2–1050 amu (0.1 amu increment) |
| Resolution | Unit Mass Resolution |
| Sensitivity | Auto-tune Mode |
| Scan Speed | 150,000 u/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Heating/Cooling Rate | Enabled by Low Thermal Mass (LTM) modules for direct, rapid column heating and cooling |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable data systems (when paired with OpenLab CDS or ChemStation software) |
| Brand | Agilent |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 400 °C |
| Oven Ramp Rate | 0.1–120 °C/min |
| Cooling Mechanism | Low Thermal Mass (LTM) module enables rapid column heating and cooling |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | up to 970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | up to 970 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B-5977B |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional Gas Chromatography-Mass Spectrometry |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (full width at half maximum, FWHM) |
| Sensitivity | >300:1 signal-to-noise ratio (S/N) for methyl stearate or chlorobenzene (typical electron ionization, EI) |
| Scan Speed | 15,000 u/s |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Control | Electronic Pressure Control (EPC) |
| Oven Temperature Range | 4 °C above ambient to 450 °C |
| Detection Limit (FID) | <5 pg C/s (propane) |
| Autosampler | Agilent 7683 with 100-position tray |
| Injection Volume | 0.1–100 µL |
| Total Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 7900 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization with Quadrupole Mass Filtering |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | 8255 NCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Selective Nitrogen-Specific Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 8355 SCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Elemental-Specific Chromatographic Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 8453 |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | < ±0.2 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | ≤ 0.03% T |
| Automation Level | Automatic Wavelength Scanning |
| Instrument Classification | Imported High-Performance UV-Vis Spectrophotometer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Valve Temperature Control Range | Ambient + 5 °C to 300 °C |
| Sample Vial Capacity | 48 positions |
| Compatible Vial Sizes | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Pricing | Available upon request |
| Temperature Control Precision | Optional cooling plate enables sample stabilization at 4 °C |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | 8860 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | +8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C to 50 °C in 5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Agilent 8860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Ultra-High-Purity (UHP) Electronic Specialty Gas Analysis |
| Oven Temperature Range | 8 °C above ambient to 425 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Model | Agilent 8860 |
| Detector Type | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Column Oven Temp Range | 8 °C above ambient to 425 °C |
| Max Ramp Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Temperature Resolution | 0.1 °C |
| Max Run Time | 999.99 min |
| PDHID Detection Limit | ≤10 ppb (as CH₄) |
| Linear Dynamic Range | 10⁵ |
| Measurable Impurities | H₂, O₂/Ar, N₂, CH₄, CO, CO₂, C₂H₆ |
| Compliance | GB/T 28726–2012, JJG 700–2016, GB/T 8979–2008, GB/T 4842–2006, GB/T 4844.3–2005, GB/T 3634.2–2011, GB/T 6052–2011 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Agilent 8860 |
| Instrument Type | Laboratory Gas Chromatograph |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Oven Dimensions | 28.0 × 30.5 × 16.5 cm |
| Operating Temperature Range | 8 °C above ambient to 425 °C |
| Temperature Setpoint Resolution | 0.1 °C |
| Max Heating Rate | 75 °C/min |
| Cooling Rate | 300 °C → 50 °C in ≤5.7 min (at 25 °C ambient) |
| Max Run Time | 999.99 min |
| Temperature Programming | Up to 20 ramps (including negative ramps) |
| Ambient Temperature Rejection | <0.01 °C per 1 °C ambient change |
| Analog Outputs | Two channels (1 V and 10 V standard) |
| Remote Control | Start/Stop via digital I/O |
| Connectivity | Ethernet (LAN) |
| Flow Selection Valve | BCD-encoded input |
| Operating Environment | 15–35 °C, 5–90% RH (non-condensing) |
| Storage Range | −40 to 70 °C |
| Max Operating Altitude | 4600 m |
| PDHID Detection Limit | ≤10 ppb (as CH₄) |
| Linear Dynamic Range | 10⁵ |
| Measurable Impurities in HBr | H₂, O₂, N₂, CH₄, CO, CO₂, C₂H₆, H₂O, HCl |
| Compliance Standards | GB/T 28726–2012, JJG 700–2016 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8890 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Maximum Ramp Rate | 120 °C/min (75 °C/min with 120 V power supply) |
| Oven Cool-down | 4.0 min from 450 °C to 50 °C (ambient 22 °C) |
| Detector Options | FID, TCD, SCD, NCD, compatible with single-quadrupole, triple-quadrupole, and Q-TOF GC/MS platforms |
| Retention Time Reproducibility | <0.008% RSD |
| Peak Area Reproducibility | <0.5% RSD |
| Pressure Control Resolution | 0.001 psi |
| Dual-Tower Simultaneous Injection | Yes |
| Dimensions (W × D × H) | 58 cm × 51 cm × 49 cm |
| Microfluidic Flow Control Technology (CFT) | Fully integrated |
| Cryogenic Cooling Options | –80 °C (LN₂), –40 °C (CO₂) |
| Inlet Configurations | Up to 2 inlets + 10 valves |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Agilent 8890 PDD |
| Pricing | Available Upon Request |
| Detection Principle | Pulsed Discharge Helium Ionization Detection (PDHID) |
| Column Oven Range | 40 °C above ambient to 450 °C |
| Temperature Stability | < 0.01 °C per 1 °C ambient fluctuation |
| Max Ramp Rate | 120 °C/min |
| Cooling Time | ≤6 min (450 °C → 50 °C at 22 °C ambient) |
| LOD | 5–25 ppb (gas-dependent) |
| Compliance | GB/T 28726-2012, JJG 700-2016, GB/T 8979-2008, GB/T 4842-2006, GB/T 4844.3-2005, GB/T 3634.2-2011, GB/T 6052-2011 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Agilent 8890 |
| Quotation | Upon Request |
| Detector | Dual-Pulse Helium Ionization Detector (PDHID) |
| Column Oven Temp Range | 40 °C above ambient to 450 °C |
| Temp Setpoint Resolution | 1 °C |
| Ramp Rate | 0.1–120 °C/min |
| Temp Stability | <0.01 °C per 1 °C ambient fluctuation |
| Programmable Temperature Steps | 20 ramps / 21 platforms |
| Max Run Time | 999.99 min |
| Cool-down | ≤6 min (450 °C → 50 °C at 22 °C ambient) |
| Detection Limits | 5–10 ppb for H₂, O₂/Ar, N₂, CH₄, CO, CO₂, C₂–C₄ hydrocarbons, SiH₃Cl, Si₂H₆, and other silicon-containing impurities in electronic-grade silane (≥99.9995% purity) |
| Compliance | GB/T 28726–2012, JJG 700–2016, GB/T 15909–2017 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Agilent 8890 |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 8900 |
| Instrument Type | Quadrupole-based Triple Quadrupole Mass Spectrometer |
| Application Environment | Laboratory |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | 990 GC |
| Detection Limit | 0.5 ppm (on WCOT capillary column) |
| Repeatability | RSD < 0.5% for 1 mol% propane on WCOT column under isothermal and isobaric conditions |
| Carrier Gases | Helium, Hydrogen, Nitrogen, Argon |
| Column Oven Max Temperature | 180 °C |
| Injector Max Temperature | 110 °C |
| TCD Linear Dynamic Range | 10⁵ (0.5 ppm to 5%) |
| TCD Concentration Range | 0.5 ppm to 100% |
| Inlet Pressure Rating | 100 kPa (14.5 psi) |
| Sample Loop | Micro-machined, fixed-volume, non-split |
| Detector Type | Micromachined Dual-Channel Thermal Conductivity Detector (TCD) |
| Maximum Independent Channels | 4 |
| Column Types Supported | WCOT, PLOT, Micro-packed (Hayesep D, Carboxen) |
| Peak Area Reproducibility | < 0.5% RSD |
| Environmental Certification | My Green Lab ACT Label (Accountability, Consistency, Transparency) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AA DUO |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Monochromator Type | Custom High-Resolution Echelle Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Zeeman Effect |
| Linear Dynamic Range | Sub-ppt to Percent-Level Concentrations |
| Automation | Fully Integrated Dual-Atomizer Control via Agilent Workstation Software |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ADS 2 |
| Pricing | Available upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 3500 |
| Instrument Architecture | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 – 1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 0.1 – 5.0 nm (UV-Vis) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Cary 4000 |
| Optical Design | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 175–900 nm |
| Automation Level | Motorized Wavelength Scanning |
| Spectral Bandwidth | 0.01–5.00 nm (variable) |
| Photometric Range | 0–8.0 Abs |
| Light Sources | Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Maximum Scan Speed | 2000 nm/min |
| Sample Compartment Z-Height | 20 mm |
| Dimensions (W×D×H) | 1020 × 710 × 380 mm |
| Weight | 91 kg |
| Power Requirement | 100–240 VAC, 50/60 Hz |