Chemical Analysis Instruments
Filter
Showing 4201–4230 of 4329 results
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fourier Transform |
| Spectral Resolution | ≤0.25 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | ≥55,000:1 |
| Wavenumber Accuracy | ±0.005 cm⁻¹ |
| Spectral Range (Standard) | 8000–350 cm⁻¹ |
| Extended Range (Optional) | 12800–4000 cm⁻¹ |
| Interferometer | Cube Corner Retroreflector-Based Michelson Design |
| Detector Interface | Dual-Channel 32-bit ADC Architecture |
| Standard Detector | Room-Temperature DLaTGS |
| Optional Detectors | Liquid-Nitrogen-Cooled MCT, TE-Cooled MCT, LN₂-Cooled InSb, TE-Cooled InGaAs, LN₂-Cooled Ge |
| Beam Splitter Options | Ge-Coated KBr, Quartz, CaF₂, ZnSe |
| Source Options | Ceramic Globar, Tungsten-Halogen |
| Sample Compartment | Transmission-Compatible with Vacuum/N₂-Purged External Ports |
| Optional Accessories | TGA-FTIR Coupling Module, GC-FTIR Interface, UHV-Ready External Chamber, Gas Cells (2 cm–20 m), Integrating Sphere, In Situ Transmission/DRIFTS Cells, Micro-FTIR, ATR Probes (Including Mid-IR Fiber ATR), Specular Reflection Stage |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fourier Transform |
| Spectral Resolution | ≤0.25 cm⁻¹ |
| Wavenumber Accuracy | <0.01 cm⁻¹ |
| Vacuum Level | ≤0.2 mbar |
| Spectral Range (Standard) | 6000–50 cm⁻¹ |
| Extended Range | 12500–10 cm⁻¹ |
| Interferometer | Domestic High-Stability Retroreflector-Based Interferometer |
| Beam Splitter Options | KBr, CaF₂, Quartz, ZnSe |
| Detector Options | DLaTGS (standard), InGaAs, MCT, Liquid-He-Cooled Bolometer |
| Light Source Options | Ceramic IR Source (standard), Water-Cooled Hg Arc Lamp, Tungsten Filament Lamp |
| ATR Accessory | Diamond Crystal (Vacuum-Compatible) |
| Software | Windows 10–Based Full Chinese GUI with Spectral Library Management, Quantitative Analysis, and Automated CO₂/H₂O Subtraction |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Spectral Range | 5000–500 cm⁻¹ (ZnSe anti-humidity version) |
| Spectral Resolution | < 0.9 cm⁻¹ |
| Wavenumber Accuracy | < 0.01 cm⁻¹ |
| Interferometer | Domestic high-stability立体角镜 interferometer with permanent alignment |
| Beam Splitter | Ge-coated KBr, optimized for mid-IR |
| Detector | Fast-response pyroelectric detector |
| IR Source | High-energy SiN mid-IR source |
| Laser | Solid-state diode laser (>10 yr lifetime) |
| Environmental Sealing | Integrated desiccant system with real-time internal T/RH monitoring and auto-humidity alarm |
| Dimensions | 17 × 39.5 × 22.3 cm |
| Connectivity | Ethernet interface |
| Power | 100–240 VAC, 50–60 Hz |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FI-RXM-S |
| Price | Upon Request |
| Application Scope | General-purpose (Universities & Research Institutions) |
| Spectral Range | 12,500–4,000 cm⁻¹ (800–2500 nm) |
| Spectral Resolution | Better than 2 cm⁻¹ |
| Wavenumber Accuracy | < 0.1 cm⁻¹ |
| Light Source | Tungsten-Halogen Lamp (5-year lifetime) |
| Interferometer | Solid-angle Mirror Interferometer with Permanent Alignment |
| Beam Splitter | Calcium Fluoride (CaF₂) |
| Detector | Thermoelectrically Cooled Indium Gallium Arsenide (InGaAs) |
| Sample Compartment | Sapphire Rotating Cup (Low-OH, High-Transmittance) |
| Laser | Solid-State Laser (10-year lifetime) |
| Integration Sphere | Gold-Coated Internal Integrating Sphere with Auto-Switching Gold Reference Background |
| Environmental Monitoring | Real-time internal temperature and humidity display with automatic humidity alarm |
| Software | Built-in chemometric suite supporting preprocessing, multivariate calibration (PLS, PCR), multi-component simultaneous prediction, and model transfer |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Instrument Category | Fourier Transform |
| Spectral Resolution | <1 cm⁻¹ |
| Wavenumber Accuracy | <0.01 cm⁻¹ |
| Spectral Range | 5000–500 cm⁻¹ |
| Interferometer | Domestic High-Stability Cubic Corner Retroreflector Interferometer (Lifetime >10 years) |
| Beam Splitter | ZnSe for Mid-IR, Humidity-Resistant |
| Detector | Desiccated High-Sensitivity DLaTGS with Integrated ADC |
| Light Source | Long-Life Mid-IR Ceramic Source |
| Laser | Solid-State Laser (Lifetime >10 years) |
| ATR Crystal | Monolithic Diamond Embedded in Passivated Stainless Steel |
| Display | 7-inch Capacitive Touchscreen Running Windows 10 |
| Battery | Rechargeable Li-ion, 4 h Continuous Operation |
| Power Input | 100–240 VAC, 50–60 Hz |
| Dimensions | 260 × 163 × 128 mm (with auto-pressure ATR head) |
| Weight | <4.5 kg |
| Operating Temperature | −10 °C to +40 °C |
| Storage Temperature | −20 °C to +55 °C |
| Environmental Sealing | Integrated Desiccant Dry Tube + Real-Time Internal Humidity/Temperature Monitoring & Alert |
| Connectivity | Wi-Fi 802.11ac, Bluetooth 5.0, USB-C Data/Charging Port |
| Onboard Camera | Integrated for Sample Imaging |
| Software | Fully Localized Chinese FTIR Analysis Suite with Automated “Acquire–Analyze–Report” Workflow |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Instrument Principle | Fourier Transform Infrared (FT-IR) |
| Spectral Resolution | 1 cm⁻¹ |
| Spectral Range | 500–5000 cm⁻¹ |
| Interferometer | Cube Corner Michelson Interferometer |
| IR Source | Air-Cooled Ceramic Source |
| Beam Splitter | Zinc Selenide (ZnSe) |
| Detector | High-Sensitivity DLATGS |
| ATR Sampling | Single-Bounce Diamond ATR |
| Operating Temperature | −5 to 40 °C |
| Operating Humidity | 0–100% RH |
| Weight | 10 kg |
| Dimensions | 41 × 32 × 17 cm |
| Battery Life | Up to 4 hours (internal Li-ion) |
| Power Input | 18–24 V DC (vehicle battery compatible) or 100–240 V AC, 50–60 Hz, 20 W |
| Control Interface | 10-inch capacitive touchscreen (Windows 10 OS optional) |
| Reference Libraries | Hazardous Chemicals, Explosives, Narcotics, Pesticides, Pharmaceuticals, White Powders, Gases |
| Brand | ZOLIX |
|---|---|
| Model | FI-RXT-TS |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (OEM Producer) |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Optical Principle | Fourier Transform Interferometry |
| Spectral Range | 12,500–4,000 cm⁻¹ (800–2500 nm) |
| Spectral Resolution | <2 cm⁻¹ |
| Wavelength Accuracy | <0.1 cm⁻¹ |
| Light Source | Tungsten-Halogen Lamp (5-year lifetime) |
| Interferometer | Cube-Corner Retroreflector-Based, Self-Aligning Design |
| Beam Splitter | CaF₂ |
| Detector | Thermoelectrically Cooled InGaAs |
| Laser | Solid-State Reference Laser (10-year lifetime) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | Finder 930 |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–2500 cm⁻¹ |
| Spectral Resolution | < 1.5 cm⁻¹ |
| Spatial Resolution | 50 µm (with 532 nm excitation and 50 µm pinhole) |
| Minimum Wavenumber | See manual |
| Spectral Repeatability | See manual |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Finder Edge 1064 nm |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 200–2500 cm⁻¹ |
| Spectral Resolution | <14 cm⁻¹ @ 1262.339 nm |
| Detector | Cooled InGaAs array |
| Excitation Wavelength | 1064 nm (NIR) |
| Spatial Resolution | Not specified in datasheet |
| Minimum Detectable Wavenumber | Not specified in datasheet |
| Spectral Reproducibility | Not specified in datasheet |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | Configurable per application (e.g., 200–3200 cm⁻¹ typical) |
| Spectral Resolution | <10 cm⁻¹ (FWHM, dependent on grating and detector configuration) |
| Spatial Resolution | Diffraction-limited at excitation wavelength (e.g., ~1–5 µm at 785 nm) |
| Minimum Wavenumber | ≥200 cm⁻¹ (laser rejection optimized) |
| Spectral Reproducibility | <±0.5 cm⁻¹ over 8-hour operation |
| Battery Life | 4–6 hours continuous operation |
| Compliance | Designed for ASTM E1840, ISO/IEC 17025-aligned workflows, FDA 21 CFR Part 11-ready software architecture |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Finder Edge |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–2000 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Low-Wavenumber Cutoff | 150 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.15 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX (Producer) |
| Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–2000 cm⁻¹ (optional: 150–2300 cm⁻¹) |
| Spectral Resolution | 6–10 cm⁻¹ |
| Spatial Resolution | 1 µm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | 0.01 cm⁻¹ |
| Excitation Wavelength | 785 nm |
| Laser Power | 100 mW |
| Detector | Scientific-grade Thermoelectrically Cooled CCD (NIR-enhanced) |
| F-number | f/3 |
| Power Supply | 110/220 V AC (12 V @ 4 A DC output) |
| Dimensions (W×H×L) | 216 × 166 × 352 mm |
| Weight | 5 kg |
| Baseline Subtraction | Real-time & post-acquisition polynomial fitting and subtraction |
| Monitoring Pathway | Integrated coaxial visible-light monitoring optical path with on-screen crosshair positioning and focus-point memory |
| Standard Sample Carrier | Microscope slide (25 × 75 mm), customizable |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Finder Insight |
| Price Range | USD 28,000 – 42,500 |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–2000 cm⁻¹ (FI-R-A) |
| Spectral Resolution | 6–10 cm⁻¹ |
| Spatial Resolution | Micron-level |
| Minimum Wavenumber | 150 cm⁻¹ |
| Spectral Repeatability | ≤ ±0.25 cm⁻¹ |
| Excitation Wavelengths | 785 nm (FI-R-A), 532 nm (FI-G-A) |
| Laser Power | 100 mW (785 nm), 50 mW (532 nm) |
| Detector | Scientific-grade thermoelectrically cooled CCD, NIR-enhanced |
| F-number | f/3 |
| Power Supply | Standard AC 110/220 V with 12 V @ 4 A DC output |
| Dimensions (W×H×L) | 216 × 166 × 352 mm |
| Weight | 5 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Finder One |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 100–5,000 cm⁻¹ |
| Spectral Resolution | <3 cm⁻¹ |
| Spatial Resolution | 1 µm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Finder Ultimate |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1000 nm |
| Spectral Resolution | ≤1 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 15 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Finder Vista |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–5,000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | ≤1 µm (lateral), ≤2 µm (axial) |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Standard Laser | 532 nm (≥100 mW, TEM₀₀) |
| Optional Lasers | 266 nm, 325 nm, 633 nm, 785 nm |
| Microscope Configuration | Upright |
| Detector | TE-cooled back-illuminated CCD (LDC-DD technology), 2000 × 256 pixels, 15 × 15 µm pixel size, QE ≥95% @ 780 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FinderInsight |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–2000 cm⁻¹ |
| Spectral Resolution | 6–10 cm⁻¹ |
| Spatial Resolution | 1 µm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | ±0.01 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FlashSENS |
| Price | USD 84,000 (FOB Beijing) |
| Dispersive Element | Holographic Grating |
| Slit Width (Spectral Bandpass) | 0.01–3 mm (motorized, programmable) |
| Spectral Resolution | 0.6 nm @ 300 grooves/mm |
| Sensitivity | 0.00024 OD (optical density) |
| Wavelength Accuracy | ±0.8 nm @ 300 grooves/mm |
| Detection Light Source | LDLS-based Supercontinuum White Light (190–2100 nm) |
| Time Resolution | <7 ns (optional ultrafast mode: 3 ns) |
| Sample Compatibility | Solid films, liquid solutions, colloidal suspensions, thin-film devices |
| Measurement Modes | Transient Absorption Kinetics (ΔA vs. t), Transient Absorption Spectra (ΔA vs. λ), Dual-mode (kinetics + spectra) |
| Monochromator | Omni-λ300i, 300 mm focal length |
| Detector Options | Si photodiode (300–1100 nm), InGaAs array (900–1600 nm), ICCD (180–850 nm, gated, -25°C thermoelectric cooling) |
| Pump Laser Compatibility | Nd:YAG harmonics (1064/532/355/266 nm), tunable OPO (210–2400 nm) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Flex One |
| Instrument Architecture | Dual-Wavelength Excitation Pathway |
| Detector Type | Scientific-grade Cooled CCD |
| Spectral Range | 300–2200 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Resolution | 0.1 nm (typical, configuration-dependent) |
| Spectral Bandwidth | 0.05 nm |
| Stray Light Level | <1×10⁻⁵ |
| Automation Level | Motorized Wavelength Scanning & Positioning |
| Optional Modules | Automated Mapping (50 mm × 50 mm stage), Electroluminescence (EL) Integration, Micro-Raman Coupling, Cryogenic Sample Stage (<10 K) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Flex One |
| Price | USD 70,000 (approx.) |
| Dispersive Element | Holographic Grating & Interference Filters |
| Slit Width (Spectral Bandpass) | 0.05 nm |
| Optical Resolution | 0.1 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Range | 300–2200 nm (standard configuration) |
| Spatial Resolution | <50 µm |
| Excitation Wavelength Options | 266, 325, 405, 442, 473, 532, 633, 785 nm |
| Detector Options | Cooled Si CCD (2000×256), PMT, Single-Point InGaAs, Cooled InGaAs Array (512×1), or Custom Detector Modules |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 5000–500 cm⁻¹ (FOLI 20-Z) / 7500–400 cm⁻¹ (FOLI 20-ZE) |
| Resolution | ≤2 cm⁻¹ |
| Wavenumber Accuracy | ≤0.01 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | ≥40,000:1 (at 4 cm⁻¹, 1 min scan) |
| Transmittance Accuracy | ≤0.1% τ |
| Beam Splitter | ZnSe (standard) or KBr (FOLI 20-ZE models) |
| Detector | Standard DLaTGS |
| Laser | Solid-state He–Ne reference laser |
| Dimensions | 550 × 450 × 230 mm |
| Weight | 20 kg |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaArtScanner |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GaiaChem |
| Pricing | Upon Request |
| Operating Mode | Push-broom Scanning |
| Spectral Range (nm) | 900–1700 (NIR) / 970–2500 (SWIR) |
| Spectral Resolution (nm) | 6 (NIR) / 10 (SWIR) |
| Spectral Bands | 256 |
| Spatial Pixels per Line | 320 |
| Spatial Resolution (µm) | 30–300 |
| Scan Range (mm) | 10–100 |
| Max Sample Dimensions (mm) | 100 × 100 × 40 (W × L × T) |
| Max Scan Speed | 100 hyperspectral line images/s |
| Typical Acquisition Time | 3–10 s (320 × 320 spatial pixels, 256 bands) |
| Illumination Source | SPECIM Diffused Line Illumination Unit |
| Data Format | BIL (Band Interleaved by Line), ENVI & Evince Compatible |
| Spectral Calibration | Factory-performed |
| Reflectance Intensity Calibration | Auto-compensated per scan using internal reference tile |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GaiaField Pro-N17E Lite |
| Operating Principle | Push-broom Scanning |
| Imaging Mode | 3D Spatial-Spectral Cube Acquisition |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Range | 960–1640 nm |
| Spectral Resolution | 5 nm (FWHM) |
| Numerical Aperture | f/2.0 |
| Slit Dimensions | 30 µm × 14.2 mm |
| Detector | InGaAs |
| Spatial × Spectral Pixels | 256 × 320 |
| Spectral Bands | 320 (standard), 160 (binning mode) |
| Dynamic Range | 12-bit |
| Field of View (TFOV) | 12.2° (@ 30 mm lens) |
| Image Spatial Resolution | 256 × 400 pixels per cube |
| Scan Speed | 4 s/cube |
| Weight | 7.5 kg |
| Integrated Battery | 120 Wh (operational duration > 2 h) |
| Connectivity | Wi-Fi (Android/iOS remote control), optional serial RF link for long-range telemetry |
| Data Format | ENVI-compatible BIL/BIP, supports Evince, ENVI, SpecSight, and MATLAB workflows |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaField-V10E |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | <3 nm |
| Spatial Resolution (IFOV) | <0.1° |
| Field of View (TFOV) | 20° |
| Image Resolution | 1392 × 1040 pixels |
| Frame Rate | 25–120 fps |
| Scanning Mechanism | Optomechanical Push-broom with Motorized Horizontal Scan (±22.5°, 45° total) |
| Detector Type | Uncooled CCD |
| Pixel Size | 6.45 × 6.45 µm |
| A/D Depth | 14-bit |
| Dynamic Range | 60 dB |
| Optical Interface | C-Mount |
| Lens Focal Length | 25 mm |
| f-number | F/2.4 (spectrometer), F/1.4–F/17 (lens) |
| Total Optical Throughput | >50% |
| Stray Light | <0.5% |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| System Weight | 8 kg |
| Form Factor | Hand-carried integrated unit |
| Data Output Format | Standard raw binary cube (.raw) compatible with ENVI, Specim IQ, and MATLAB |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaMicroscope |
| Pricing | Available upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics |
| Type | GaiaSorter |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm (at VNIR band) |
| Spatial Resolution (IFOV) | 30 µm / 50 µm |
| Imaging Resolution | 1392 × 1040 pixels |
| Field of View (TFOV) | 20° |
| Frame Rate | 25–120 fps |
| Imaging Mode | Push-broom Hyperspectral Scanning |
| Deployment | Ground-based & Airborne Compatible |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments and industrial QA/QC workflows |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GaiaTracer |
| Pricing | Available upon Request |
| Brand | ZOLIX |
|---|---|
| Model | Gas Raman Analyzer |
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics Co., Ltd. |
| Type | Raman Spectroscopy-Based Gas Analyzer |
| Laser Excitation | 532 nm (0–1.5 W, power stability <3% RMS) |
| Optical Architecture | High-throughput transmissive imaging spectrometer with deep-cooled high-sensitivity CCD/CMOS detector |
| Enhanced Optical Path | Optimized Raman collection geometry with gas cell integration |
| Detection Modes | Static gas cell, high-pressure folded-path cell, integrating sphere, photonic crystal fiber (PCF) gas cell |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GX |
| Pricing | Available Upon Request |