| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | HiperS-320i |
| Application System | Universal |
| Grating Mount | Triple-grating in-axis rotating turret |
| Spectral Resolution | 0–1430 nm range (with resolution down to 0.06 nm @ 1200 g/mm grating, PMT detection) |
| Linear Dispersion | 2.29 nm/mm (@ 435.83 nm) |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light Level | 5×10⁻⁵ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Grating-Based Raman Spectrometer |
| Model | Holospec/EMvision |
| Price | USD 100,000 |
| Spectral Range | 532–1100 nm |
| Spectral Resolution | 6.5 cm⁻¹ |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Repeatability | ±0.1 cm⁻¹ |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | HyperSIS |
| Pricing | Available Upon Request |
| Spectral Range Options | 400–1000 nm (VNIR), 900–1700 nm (NIR), 1000–2500 nm (SWIR) |
| Max Frame Rate | Up to 100 images/s |
| Sample Dimension Limit | ≤200 mm × 200 mm × 100 mm |
| Scanning Mechanism | Push-broom (line-scan) with motorized X-stage |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Models | iKon-M SO |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Finland |
| Manufacturer | Specim, Oy (distributed by ZOLIX) |
| Type | Imported Hyperspectral Imager |
| Model Range | UV/HS/QE/PFH/NIR / Image-λ V8/V10/N17E/N25E |
| Spectral Range | 380–2500 nm |
| Spectral Resolution | 2–10 nm |
| Detector Types | CCD, Cooled CCD, CMOS, InGaAs, MCT |
| Spatial Resolution | Up to 1600 × 1200 pixels |
| Frame Rate | 11–180 fps |
| Interface | Ethernet, USB, Camera Link (CL), FireWire (FW), LVDS |
| Brand | ZOLIX |
|---|---|
| Model | Imspector Series |
| Type | Grating-Based Imaging Spectrometer |
| Wavelength Ranges | UV (200–400 nm), VIS (380–780 nm), VNIR (400–1000 nm), NIR (900–1700 nm), SWIR (1000–2500 nm), MWIR (3000–5000 nm), LWIR (8000–12000 nm) |
| Detector Interface | Compatible with 2/3″ and larger area array detectors |
| Frame Rate (Fast Version) | Up to 1500 spectra/s |
| Optical Design | Transmissive grating-based, Czerny-Turner or Offner relay architecture (model-dependent) |
| Compliance | Designed for laboratory and field-deployable spectroscopic imaging applications in accordance with ISO 17025-aligned calibration practices |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Element | Grating + Bandpass Filters |
| Integration Configuration | Glovebox-Compatible Fiber-Coupled Optical Path (Y-Fiber Geometry) |
| Brand | ZOLIX |
|---|---|
| Model | iTracer |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Operating Principle | Whiskbroom Scanning |
| Imaging Modality | 3D Hyperspectral Cubes |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Ranges | 200–400 nm, 380–800 nm, 400–1000 nm, 900–1700 nm, 1000–2500 nm |
| Spectral Resolution | 0.01 nm |
| Spatial Resolution | 1280 × 1024 pixels |
| Total Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.1 mrad |
| Frame Rate | 5 fps |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Form Factor | Benchtop |
| Model | LIF&PLIF Diagnostic System |
| Key Features | Tunable Dye Laser (220–780 nm), Sub-nanosecond ICCD Gating (≤2 ns optical gate width), 5 ps Timing Resolution, 4-Channel Digital Delay Generator, Planar Laser Sheet Formation (0.1–0.3 mm thickness), PIV-Compatible Architecture |
| Compliance | Designed for ASTM E2912-compliant combustion diagnostics |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | LIF-Spectroscopy System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LIBS-E900 |
| Instrument Form Factor | Benchtop |
| Detection Wavelength Range | 200–900 nm (customizable) |
| Optical Resolution | <0.1 nm (higher resolution optional) |
| Minimum Gating Width | 3 ns |
| Detector | Domestic iCMOS Camera |
| Timing Precision (Delay & Gate) | 10 ps |
| Laser Pulse Energy Options | 50, 100, 200, 400 mJ |
| Wavelength Repeatability | ±0.01 nm |
| XYZ Translation Stage | Customizable Travel Range |
| Sample Environment Control | Gas Purge Capability |
| Real-Time Autofocus | Laser + Vision Algorithm Based |
| Software Features | Peak Identification, FWHM Calculation, Auto-Save, Elemental Mapping, Pseudocolor Distribution Rendering, Database Integration Interface |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Model | LIBS-Multi900 |
| Key Spectral Ranges | 195–1000 nm (combined LIBS + Raman) |
| LIBS Detection Range | 200–900 nm |
| Raman Shift Range | 80–4000 cm⁻¹ |
| Optical Resolution (LIBS) | <0.1 nm (configurable) |
| Time-Gated Detection | Minimum 3 ns, Timing Precision ±10 ps |
| Laser Energy Options | 50 / 100 / 200 / 400 mJ |
| Excitation Wavelength (Raman) | 532 nm |
| Raman Spectral Resolution | 2 cm⁻¹ |
| Vacuum Compatibility | Ultra-High Vacuum (UHV), down to 10⁻⁸ Pa |
| Sample Temperature Range | 4 K to RT |
| XYZ Motorized Stage | Fully Customizable Travel |
| In-Situ Imaging | Long-Working-Distance Microscope with Real-Time Visual Feedback |
| Automated Focus Tracking | Laser- and Vision-Based Surface Topography Compensation |
| Mapping Capability | Co-registered LIBS/Raman point-by-point scanning |
| Software Control | Unified GUI for hardware orchestration, spectral acquisition, peak identification, data export, and database integration |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LIBS-OL900 |
| Instrument Form Factor | Benchtop |
| Price | USD 280,000 (approx.) |
| Spectral Range | 200–1000 nm |
| Optical Resolution | 0.1 nm |
| Conveyor Belt Speed Compatibility | ≤5 m/s |
| Data Acquisition Mode | Real-time spectral mapping with automated focus tracking |
| Software Features | Peak identification, FWHM analysis, auto-save, pseudo-color elemental distribution visualization, database-assisted quantification, multi-interface data export (CSV, HDF5, SQL-compatible) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LIF/PLIF Combustion Diagnostics System |
| Pricing | Available Upon Request |
| Tunable Dye Laser Wavelength Range | 220–780 nm (extendable to 200–4500 nm) |
| Spectral Linewidth | 0.06 cm⁻¹ |
| Pulse Energy | 110 mJ @ 560 nm |
| Laser Repetition Rate | 10 Hz |
| Laser Sheet Thickness | 0.1–0.3 mm |
| Temporal Delay Range | 0–2000 s |
| Timing Resolution | 5 ps |
| Synchronization Channels | 4 (expandable to 8) |
| ICCD Optical Gate Width | <2 ns |
| ICCD Delay Resolution | 10 ps |
| ICCD Insertion Delay | ≥19 ns |
| ICCD Photocathode Repetition Rate | up to 500 kHz |
| ICCD Cooling | −40 °C (TE-cooled) |
| iStar sCMOS Resolution | 2560 × 2160 pixels |
| iStar sCMOS Full-Frame Rate | 50 fps |
| ROI Frame Rate (512×512) | 203 fps |
| USB Interface | USB 2.0 (iStar ICCD) / USB 3.0 (iStar sCMOS) |
| PIV Mode Minimum Inter-Frame Interval | 200 ns |
| Intelligate™ UV/VUV Gating Extinction Ratio | ≥10⁸:1 |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LSH-D30 |
| Price | Upon Request |
| Lamp Power | 30 W |
| Lamp Current | 300 mA |
| Lamp Voltage | 70–90 V |
| Ignition Voltage | >350 V DC |
| Emission Region Diameter | Ø1 mm |
| Average Lamp Lifetime | 2000 h |
| Light Output Stability (Irradiance Fluctuation) | ≤0.5% RMS |
| Current Stability (LSP-D30) | ≤0.05% per hour |
| Input Voltage (LSP-D30) | 24 V DC |
| Optical Axis Height Adjustment Range | 115–154 mm |
| Spectral Output Range | 200–400 nm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Medical Endoscopic Raman Spectroscopy System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | MegaLED-Fluo |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Dispersive Elements | Holographic Grating + Bandpass/Notch Filters |
| Excitation Sources | CW Laser Diode, Pulsed Laser (ns–ps range), Electrical Probe Station (for e-pumped lasing) |
| Detection Mode | Confocal Micro-Spectroscopy with Back-Illuminated CCD or EMCCD |
| Spatial Resolution | Diffraction-Limited (~300 nm lateral at 532 nm) |
| Spectral Range | 200–1100 nm (configurable) |
| Temporal Resolution | Down to <100 ps (with TCSPC option) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MiniPL 5.0 eV |
| Excitation Wavelengths | 224 nm (5.5 eV) or 248.6 nm (5.0 eV) |
| Spectral Range (Standard) | 190–650 nm |
| Spectral Range (Optional) | 190–850 nm |
| Resolution (Standard) | 0.2 nm @ 1200 g/mm grating |
| Resolution (Optional) | 0.07 nm @ 3600 g/mm grating |
| Detector | High-sensitivity PMT |
| Signal Processing | Built-in boxcar averager for pulsed signal integration |
| Sample Stage | Manual XYZ adjustment, max. 50 mm diameter |
| Optional | Motorized XY scanning stage for PL mapping |
| Dimensions | 15 × 18 × 36 cm |
| Weight | < 8 kg |
| Software Platform | LabVIEW-based control & spectral analysis suite |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MiRass DUV |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–5,000 cm⁻¹ (325 nm excitation) |
| Spectral Resolution | ≤1 cm⁻¹ (@585.25 nm) |
| Spatial Resolution | ≤1 µm (diffraction-limited, with 100× objective) |
| Minimum Detectable Wavenumber | 15 cm⁻¹ |
| Spectral Repeatability | ≤±0.15 cm⁻¹ |
| Excitation Lasers (Standard) | 325 nm (≥30 mW, TEM₀₀), 532 nm (≥100 mW, TEM₀₀) |
| Excitation Lasers (Optional) | 244 nm, 266 nm, narrow-linewidth tunable UV–NIR laser |
| Detector | Deep-cooled back-illuminated scientific CCD |
| Detector Quantum Efficiency | >40% @ 250–400 nm |
| Pixel Array | 2048 × 512 |
| Pixel Size | 13.5 × 13.5 µm |
| Spectral Response Range | 200–1000 nm (UV-enhanced) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Steady-State & Time-Resolved Fluorescence Spectrometer |
| Excitation Sources | 808 nm, 980 nm, 1064 nm, 1550 nm, 1940 nm CW lasers |
| Detection Range | 1–5.5 μm (InSb), 2–12 μm (MCT), 800–2600 nm (TE-InGaAs), 300–1700 nm (LN-PMT) |
| Spectral Resolution | ≤0.1 nm (with 320 mm Czerny-Turner monochromator & 68 mm × 68 mm gratings) |
| Fluorescence Lifetime Range | μs to seconds (with TCSPC or oscilloscope synchronization) |
| Optical Platform | Damped vibration-isolation table (1800 × 1200 × 800 mm) |
| Brand | ZOLIX |
|---|---|
| Model | Lifetime Aging Test System |
| Type | Integrated Automated OLED Degradation Monitoring Platform |
| Origin | Beijing, China |
| Power Supply | 5 kW / 380 V AC |
| Temperature Range Options | −40 °C to 150 °C, −20 °C to 150 °C, or 0 °C to 150 °C |
| Heating Rate | 2–4 °C/min (nonlinear, no-load) |
| Cooling Rate | 0.7–1.0 °C/min (nonlinear, no-load) |
| Temp. Resolution | ±0.01 °C |
| Humidity Range | 20–98% RH (within 25–85 °C) |
| Humidity Resolution | ±0.1% RH |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.0% RH |
| Humidity Deviation | ±3% RH (at >75% RH) |
| Channel Configurations | Up to 128 independent current/voltage monitoring channels |
| Control Interface | Touchscreen HMI with programmable temperature/humidity profiles |
| Compliance | Designed for GLP-aligned operational traceability and ASTM D7602-22 (Standard Practice for Accelerated Aging of Organic Light-Emitting Diode Devices) support |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | OM512 |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-fs-TA |
| Instrument Type | Transient Absorption Spectrometer |
| Temporal Resolution | 1.5 × Laser Pulse Width |
| Sensitivity | 0.1 ΔmOD (broadband), 0.01 ΔmOD (single-wavelength) |
| Pump Wavelength Ranges | 240–480 nm, 475–1160 nm, 1160–1600 nm, 1600–2600 nm |
| Probe Wavelength Ranges | 300–700 nm |
| Detection Time Window | 4 ns / 8 ns |
| Laser Sources | 800 ± 10 nm, 1030 ± 3 nm |
| Sample Formats | Liquid, Powder, Thin Film |
| Measurement Modes | Transmission, Reflection, Back-Excitation |
| Software Features | Probe Stability Monitoring, Real-Time Spectral Preview, Spectral Calibration, Smoothing, Global & Target Data Fitting |
| Optional Modules | Micro-area Spectroscopy, Wide-field Transient Absorption Imaging, TCSPC (2 ps min. time step, 100 ps min. lifetime range, 0.08 nm spectral resolution), Femtosecond Kerr-Gated Time-Resolved Fluorescence (400–900 nm, 50 fs pulse width, 4 ns window) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-Imager |
| Price Range | USD 70,000 – 140,000 |
| Operating Principle | Push-broom scanning |
| Imaging Method | Filter-based |
| Deployment Mode | Ground-based and airborne compatible |
| Spectral Resolution | 2.8 nm @ 30 µm slit, 2 nm @ 18 µm slit |
| Detector Types | CCD (1392×1040), sCMOS (2048×2048), EMCCD (512×512), InGaAs (320×256 / 640×512) |
| Spectral Ranges | 400–1000 nm (Vis-NIR), 900–1700 nm (NIR) |
| Numerical Aperture | f/2.4 (Vis-NIR), f/2.0 (NIR) |
| Slit Dimensions | 30 µm × 14.2 mm (standard), 18 µm × 14.2 mm (optional) |
| Data Depth | 12-bit / 16-bit |
| Interface | USB 2.0 / USB 3.0 |
| Lens Mount | C-mount |
| Cooling | Air-cooled to −0 °C (CCD/sCMOS), TE-cooled to −80 °C (EMCCD), TE3-cooled (InGaAs) |
| Software | Proprietary acquisition & analysis suite with ENVI/Evince/SpecSight export compatibility |
| Optional Onboard Processing | Intel Core i7, 16 GB RAM, 256 GB SSD |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Model | Omni-iSpecT Fiber-Coupled Raman Spectroscopy System |
| Laser Options | 532 nm (100 mW), 785 nm (350 mW) |
| Raman Shift Range | 200–4000 cm⁻¹ (532 nm) |
| Spectral Resolution | <10 cm⁻¹ (typical, @50 µm slit) |
| CCD Detector | Back-illuminated deep-depletion CCD, 2000 × 256 pixels, 15 µm pixel size, -60 °C cooling, read noise <5 e⁻/pixel |
| Probe Working Distance | 3 mm / 7 mm (standard), customizable |
| Operating Temperature | 0–325 °C (customizable up to 400 °C) |
| Max Pressure Rating | 6000 psi |
| Probe Material | Hard-anodized aluminum + 316 stainless steel |
| Sealing | Perfluoroelastomer (FFKM) O-rings standard |
| Fiber Core | 100/100 µm (standard), SMA/MPO/10 mm cylindrical interface |
| Optical Throughput | F/1.8 (532 nm), F/2.3 (785 nm) |
| Grating | 1800 l/mm VPH (532 nm), 1200 l/mm VPH (785 nm) |
| Weight | 5.0 kg (spectrometer), 5.8 kg (full system) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-LIBS Integrated LIBS System |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Laser Flash Photolysis Instrument |
| Spectral Range | Application-Dependent (UV–NIR, configurable via OPA) |
| Spectral Resolution | <5 nm (typical, OPA-tunable) |
| Temporal Resolution | 500 fs (with 100-fs pump pulse) |
| Spatial Resolution | 500 nm |
| Carrier Localization Accuracy | 30 nm |
| Optical Delay Range | 0–4 ns / 0–8 ns (motorized precision delay line) |
| Detection | sCMOS camera with >95% quantum efficiency at 500–900 nm |
| Microscopy Platform | Inverted microscope with open-top design for cryostat, electrical biasing, magnetic field, and probe station integration |
| Operating Modes | Point Pump / Wide-Field Probe |
| Sample Illumination | Reflectance & Scattering Configurations Supported |
| Compliance | GLP-compliant data acquisition architecture |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-V200 |
| Price | USD 42,000 (FOB Beijing) |
| Spectral Resolution | 0.1 nm |
| Wavelength Range | 80–300 nm |
| Optical Design | Aberration-Corrected Imaging S-N System |
| Incidence Angle | 32° |
| Focal Length | 200 mm |
| Wavelength Accuracy | ±0.1 nm (@1200 g/mm grating) |
| Wavelength Repeatability | ±0.1 nm (@1200 g/mm grating) |
| Operating Vacuum | ≤1×10⁻⁶ Torr |
| Grating Groove Density | 1200 lines/mm |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Omni-λ |
| Pricing | Upon Request |
| Focal Length Options | 150 mm, 300 mm, 500 mm, 750 mm |
| Optical Design | Czerny–Turner (C-T) |
| Grating Mount | Dual-grating turret (Omni-λ150/300), Triple-grating turret (Omni-λ500/750) |
| Grating Size | 68 × 68 mm (standard for ≥300 mm models) |
| Wavelength Range | UV-VIS-NIR (190–2500 nm, dependent on grating and detector selection) |
| Resolution (with 1200 g/mm grating) | 0.4 nm (Omni-λ150) to 0.03 nm (Omni-λ750) |
| Wavelength Accuracy | ±0.25 nm (Omni-λ150) to ±0.2 nm (Omni-λ300+) |
| Wavelength Repeatability | ±0.1 nm |
| Minimum Scan Step | 0.005 nm |
| Entrance/Exit Configuration | Motorized dual-input/dual-output port selection |
| Interface | USB 2.0 (standard), RS-232 (optional) |
| Slit Options | Manual (0.01–3 mm width, 2/4/10/14 mm height) or motorized automatic slit |