Chemical Analysis Instruments
Filter
Showing 481–510 of 4337 results
| Brand | ALS |
|---|---|
| Origin | Japan |
| Model | GC3mm / 013490 |
| Disk Diameter | 3 mm |
| Insulator Diameter | 12 mm |
| Total Length | 25 mm |
| Electrode Material | Interchangeable (e.g., Pt, Au, GC, Ni, Cu, Ag, Glassy Carbon) |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Model No. | 013491 |
| Disk Material | Glassy Carbon |
| Disk Diameter | 5 mm |
| Insulator Diameter | 12 mm |
| Total Length | 25 mm |
| Insulation | PTFE (Teflon) Sleeve |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Model 2325 |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±50 mA |
| Current Resolution | 1 × 10⁻⁷ A (100 fA) |
| Potential Accuracy | ±4.0 mV |
| Potentiostatic Range | ±4.0 V |
| Dual-Channel Capability | Yes |
| Impedance Spectroscopy Support | Not Integrated |
| Dimensions | 220 × 150 × 55 mm |
| Weight | 1.2 kg |
| Interface | USB 2.0 |
| Operating System Compatibility | Windows 7/10/11 (32 & 64-bit) |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHEK/013597 |
| Instrument Type | Reference Electrode for Electrochemical Measurements |
| Electrolyte Compatibility | 1.2 mol/L HCl (pH ≈ 0, [H⁺] ≈ 1 M) |
| Reference Scale | Defined vs. Standard Hydrogen Electrode (SHE) |
| Brand | ALS (Japan) |
|---|---|
| Model | RRDE-3A |
| Rotation Speed Range | 100–8,000 rpm |
| Gas Purge Control | Programmable ON/OFF timer (up to 9999 s) |
| Display | LCD showing speed, purge duration, model ID, serial number, cumulative motor runtime, maintenance alerts |
| Electrode Compatibility | Standard 7 mm OD coaxial ring-disk electrodes |
| Motor Type | DC servo motor with PI closed-loop speed control |
| Coupling | Insulated elastomeric coupling + PTFE-insulated dual-shaft assembly |
| Cell Interface | Open-cell design with universal potentiostat pin connections |
| Remote Control | TTL/RS-232 interface compatible with ALS Model 2325 bipotentiostat and third-party electrochemical workstations |
| Operating Modes | Manual or computer-controlled (rotation ON/OFF, speed setpoint, purge gas ON/OFF) |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SEC2020 |
| Spectral Range | 200–1025 nm |
| Detector Type | Custom CMOS Array (Optimized for UV-VIS-NIR) |
| Optical Resolution (FWHM) | 1.3 nm |
| Sensitivity Range | 200–1025 nm |
| Signal-to-Noise Ratio | 1000:1 (at full integration time, 60 s) |
| Dynamic Range | 7.5 × 10⁹ (system-level, 16-bit digitization with multi-exposure synthesis) |
| Stray Light | < 0.09% at 500 nm |
| Brand | Alyxan |
|---|---|
| Origin | France |
| Model | PTR-FTICR MS |
| Mass Resolution | ≥10,000 (m/Δm, 50% valley) |
| Mass Accuracy | ≤0.015 u |
| Detection Limit | 100 ppt (v/v) for selected VOCs |
| Mass Range | 4–300 u |
| Magnetic Field Strength | 1.5 T |
| Vacuum Requirement | ≤1×10⁻⁹ Torr |
| Operating Temperature | 5–45 °C |
| Dynamic Range | 10⁴ |
| Dimensions | 65 × 72 × 104 cm |
| Weight | 150 kg |
| Ion Sources | H₃O⁺, O₂⁺, O⁻, CF₃⁺ (switchable proton-transfer reagent ions) |
| Sample Introduction | Membrane Inlet (MI), Headspace (solid/liquid) |
| Ionization Mode | Proton Transfer Reaction (PTR), optional EI/CI capability |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Variants | LARRY, LARRY-PC, LARRY-USB |
| Pricing | Upon Request |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | PARSTAT 2273 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 12 decades, 2 A to 40 pA |
| Current Accuracy | <0.4% (full scale, 20 µA–2 A) |
| Potential Accuracy | ±10 V |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (optional ±20 A) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Current Resolution | 1.2 fA |
| Input Impedance | >10¹³ Ω |
| Capacitance | <5 pF |
| Slew Rate | >15 V/µs |
| Rise Time | <250 ns |
| Minimum Time Resolution | 20 µs |
| Minimum Potential Step | 2.5 µV |
| Noise | <50 µV RMS (typical) |
| IR Compensation | Positive feedback (2 Ω to 2000 MΩ) |
| Current Interruption | 16-bit DAC |
| Voltage Output Range | ±100 V |
| Power Amplifier Output | ±100 V / ±2 A |
| Bandwidth | >15 MHz (3 dB) |
| Software | PowerSuite (PowerCV, PowerEIS, PowerPULSE, PowerSTEP, PowerCORR, PowerSINE) |
| Interface | USB |
| Operating System | Windows 98/2000/NT/XP/Vista/7 |
| Dimensions | 58 cm W × 47.6 cm D × 22.9 cm H |
| Weight | 31 kg |
| Operating Temperature | 0–50 °C (ideal at 25 °C) |
| Relative Humidity | ≤95% non-condensing |
| Altitude | up to 2000 m |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | Model 263A Potentiostat/Galvanostat |
| Instrument Type | Benchtop Electrochemical Workstation |
| Current Range | 7 decades, 100 mA to 100 nA |
| Current Resolution | 2 pA (min) |
| Potential Range | ±20 V |
| Compliance Voltage | ±20 V |
| Slew Rate | >1 V/µs |
| Rise Time | <1 µs |
| Input Impedance | >10¹² Ω in parallel with <20 pF |
| Electrometer Input Bias Current | <50 pA at 25°C |
| Minimum Time Resolution | 30 µs |
| Minimum Potential Step | 250 µV |
| Noise | <50 µV rms (typical) |
| EIS Frequency Range | Up to 100 kHz (with optional EIS module) |
| Communication Interfaces | IEEE-488 (GPIB), RS-232C |
| Software | PowerSuite (PowerSINE, PowerCORR, PowerCV, PowerSTEP) |
| Operating Temperature | 0–50 °C |
| Dimensions | 44.5 × 47.0 × 14.0 cm (W×D×H) |
| Weight | 16 kg |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | ParStat 4000 |
| Current Range | ±4 A (standard), ±20 A (optional) |
| Current Resolution | 1.2 fA (at 40 pA range) |
| Current Accuracy | ±0.5% ±4 pA (40–200 pA), ±0.2% of reading ±0.2% of range (2 nA–20 A) |
| Potential Range | ±10 V |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Bandwidth | 3.75 MHz |
| EIS Frequency Range | 10 µHz to 5 MHz |
| Sampling Rate | 1 MS/s (synchronized potential/current/auxiliary), 500 kS/s (3 × 16-bit ADC) |
| Input Impedance | ≥10¹³ Ω |
| Leakage Current | ≤2 pA (at <25°C) |
| CMRR | 60 dB @ 100 kHz |
| Compliance Voltage | ±48 V |
| Rise Time (−1.0 V to +1.0 V) | <100 ns |
| Scan Rate | up to 10 kV/s (10 mV step) |
| iR Compensation | Positive feedback & dynamic iR compensation |
| Operating Temperature | 10–50°C |
| Dimensions (L×W×H) | 515 × 490 × 195 mm |
| Weight | 23 kg |
| Certifications | CE compliant |
| Brand | AMETEK–Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ParSTAT MC Multi-Channel Electrochemical Workstation |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A (standard) |
| Current Accuracy | 20 nA–2 A: ±0.2% of reading or ±0.2% of range |
| 4 nA | <0.5% ±20 pA |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK-Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaSTAT 3 Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading or ±0.2% of range |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | VersaSTAT 3F Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading + ±0.2% of range (20 nA to 2 A) |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Floating Ground Architecture | Yes (isolated electrode connections and rear-panel interfaces) |
| Data Acquisition | 3 × 16-bit, 500 kS/s |
| Input Impedance | ≥10¹² Ω |
| Leakage Current | ≤5 pA at <25°C |
| CMRR | 60 dB @ 100 kHz (typical) |
| Compliance | CE certified, compatible with GLP/GMP environments requiring audit-trail-capable software (via VersaStudio with optional 21 CFR Part 11 modules) |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | VersaSTAT 4 Electrochemical Workstation |
| Current Range | ±1 A (standard), ±2 A (internal optional) |
| Current Accuracy | <0.5% ±20 pA at 4 nA |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Model | AMI-Master 400 Quadrupole Mass Spectrometer |
| Configuration | Benchtop Process Mass Spectrometry System |
| Ion Source | Electron Impact (EI), 70 eV standard |
| Mass Range | 1–300 amu |
| Detection Modes | Faraday Cup & Electron Multiplier (dual-mode) |
| Scan Speed | <10 ms per decade |
| Response Time | <100 ms (full-spectrum acquisition) |
| Operating Pressure (Ion Source) | 1×10⁻⁶ to 5×10⁻⁵ Torr |
| Vacuum System | Turbo-molecular pump (200 L/s) + Oil-free diaphragm backing pump |
| Inlet Temperature Control | Ambient to 200 °C (capillary + filter assembly, independently regulated) |
| Chamber Bake-out Capability | Up to 200 °C |
| Software Platform | Windows 7/10-compatible multi-channel gas analysis suite with real-time quantitation, spectral library matching, and audit-trail-enabled data logging |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Model | AMI-Master400 |
| Vacuum System | Turbo-molecular pump + oil-free diaphragm dry pump with full-range vacuum gauge |
| Inlet System | Heated stainless-steel or quartz capillary (ambient–200 °C), dual-stage pressure reduction |
| Mass Analyzer | Quadrupole mass filter with electron impact (EI) ion source |
| Detectors | Dual-mode detection — Faraday cup and electron multiplier |
| Detection Range | 100% to sub-ppb (v/v) |
| Response Time | <100 ms |
| Scan Speed | Millisecond-scale mass scanning |
| Mass Range | 1–300 u (standard), upgradable to 500 u |
| Operating Software | Multi-channel gas analysis suite for Windows 7/10, compliant with GLP/GMP data integrity requirements |
| Bake-out Capability | Mass spectrometer chamber heatable to 200 °C for in-situ outgassing |
| Compliance | Designed to support ASTM D7622, ISO 10156, USP <1251>, and FDA 21 CFR Part 11 audit-trail functionality |
| Brand | Amplitude |
|---|---|
| Origin | France |
| Model | Dazzler Ultrafast Laser Pulse Shaper |
| Spectral Range | UV to SWIR |
| Core Technology | Acousto-Optic Programmable Dispersive Filter (AOPDF) |
| Integration | Fully Integrated, Turnkey System |
| Repetition Rate Compatibility | Up to 30 kHz |
| Control | Independent, Simultaneous Spectral Phase & Amplitude Modulation |
| Form Factor | Ultra-Compact Benchtop Unit |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Detector Active Area | 25 mm² (standard) or 70 mm² (optional) |
| Thickness | 1 mm |
| Element Range | Na (Z=11) to U (Z=92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα (5.89 keV) |
| Count Rate Capability | High-throughput fast pulse processing |
| Repeatability | ±0.1% RSD (relative standard deviation) |
| Package | TO-8 metal can, pin-compatible with legacy 0.5 mm SDDs |
| Operating Voltage | Standard ±5 V bias |
| Transmission Efficiency | Enhanced above 15 keV vs. thinner detectors |
| Detector Type | Silicon Drift Detector (SDD) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | C1/C2 |
| Window Substrate | Silicon Nitride (Si₃N₄) |
| Top Layer | Aluminum Coating |
| Thickness | C1 ≈ 80 nm, C2 ≈ 150 nm |
| Compatible Detectors | SuperSDD™ Series, 25 mm² / 500 µm thick silicon drift detectors |
| Energy Range Extension | Down to Boron (B, Z=5) and Carbon (C, Z=6) |
| Compliance | ASTM E135 – Standard Terminology Relating to Analytical Chemistry |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | C1/C2 |
| Window Substrate | Silicon Nitride (Si₃N₄) |
| Front Coating | Aluminum |
| Thickness | C1 ≈ 80 nm, C2 ≈ 150 nm |
| Compatible Detectors | SuperSDD®, standard SDDs (25 mm² / 50 mm² active area) |
| Energy Range Enhancement | Extended low-energy response down to boron (B, 183 eV) and carbon (C, 277 eV) |
| Compliance | RoHS-compliant, vacuum-compatible, TEM-grid compatible |
| Mounting | Standard 3.5 mm or 5.0 mm diameter window frames |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | Fast SDD |
| Detector Type | Silicon Drift Detector (SDD) |
| Energy Resolution (FWHM) | ≤125 eV at Mn Kα (5.9 keV) |
| Peak Shaping Time | 0.2–1.0 µs (adjustable) |
| Maximum Input Count Rate | ≥1.2 Mcps |
| Output Count Rate Linearity | >99.5% up to 1.2 Mcps |
| Operating Temperature | −20 °C to −35 °C (Peltier-cooled) |
| Active Area | 50 mm² (standard) |
| Thickness | 450 µm |
| Compliance | RoHS, CE |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | Fast SDD |
| Energy Resolution (55Fe) | ≤121 eV FWHM |
| Maximum Count Rate | >1 Mcps |
| Peak-to-Background Ratio | 20,000:1 |
| Operating Temperature | <80 K (achieved with thermoelectric cooling at +30 °C ambient) |
| Package | TO-8 vacuum-sealed |
| Detector Type | Silicon Drift Detector (SDD) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | FASTSDD-70-1000 |
| Detector Type | Silicon Drift Detector (SDD) |
| Active Area | 70 mm² |
| Thickness | 1000 µm |
| Elemental Range | Be (Z=4) to U (Z=92) |
| Detection Limit | 1 ppm |
| Energy Resolution | <140 eV at Mn Kα (5.9 keV) |
| Count Rate Capability | High-throughput fast pulse processing |
| Reproducibility | ≤0.1% RSD |
| Package | TO-8 metal can, pin-compatible with legacy 0.5 mm thick SDDs |
| Operating Voltage | Standard ±5 V analog output |
| Transmission Efficiency | Enhanced above 15 keV vs. thinner SDDs |
| Mounting Form Factor | Benchtop and floor-standing EDXRF systems |
| Brand | AMPTEK |
|---|---|
| Origin | USA |
| Model | FASTSDD & DP5-X |
| Element Range | Li to U |
| Detection Limit | 1 ppm |
| Concentration Range | 1 ppm – 99% |
| Energy Resolution | <140 eV (at Mn Kα, 5.9 keV) |
| Count Rate Capability | >1,000,000 cps |
| Repeatability | ±0.1% RSD |
| Detector Type | Fast Silicon Drift Detector (FASTSDD) |
| Form Factor | Portable / Handheld-Compatible Integrated Detector System |
| Compliance | RoHS/WEEE-ready architecture |
| Application Domain | OEM Integration, Process Monitoring, Laboratory Research, Regulatory Screening |
| Brand | AMPTEK |
|---|---|
| Origin | USA |
| Model | FASTSDD |
| Active Area Options | 25 mm² (collimated to 17 mm²) or 70 mm² (collimated to 50 mm²) |
| Energy Resolution | ≤122 eV at 5.9 keV |
| Maximum Count Rate | >1,000,000 cps |
| Peak-to-Background Ratio | 26,000:1 |
| Preamplifier Rise Time | <35 ns |
| Window Options | Beryllium (0.5 mil / 12.5 µm) or Silicon Nitride (C-series / Si₃N₄) |
| Detector Thickness | 500 µm |
| Package | TO-8 |
| Cooling Delta-T | >85 K |
| Noise Performance | Optimized for low electronic noise and high charge collection efficiency |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | MCA8000D |
| Detector Interface | Analog Pulse Input (Unipolar/Bipolar) |
| ADC | 100 MHz, 16-bit |
| Channel Count | Up to 8192 (8K) |
| Differential Nonlinearity | < ±0.6% |
| Integral Nonlinearity | < ±0.02% |
| Peak Pileup Rejection | Dual TTL-compatible Gate Inputs (GATE1/GATE2) |
| Communication Interfaces | USB 2.0 Full-Speed (12 Mbps), RS-232 (115 kbps), 10BASE-T Ethernet (10 Mbps) |
| Input Voltage Range | 0–1 V or 0–10 V (software-selectable) |
| Input Impedance | 1 kΩ or 100 kΩ (factory-configurable) |
| Minimum Pulse Height | 5 mV |
| Pulse Peaking Time | ≥500 ns (200 ns shaping) |
| Conversion Time | 10 ns |
| Sliding-Scale Linearization | Yes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 125 × 71 × 20 mm |
| Weight | 165 g |
| Power | +4–5.5 V DC, ≤2 W (USB or external AC/DC adapter) |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | MCA8000D |
| ADC | 100 MHz, 16-bit |
| Channel Count | 8,192 (8K) |
| Pulse Peaking Time | ≥500 ns (200 ns shaping) |
| Conversion Time | 10 ns |
| Differential Nonlinearity | <±0.6% |
| Integral Nonlinearity | <±0.02% |
| Input Range | 0–1 V or 0–10 V (software-selectable) |
| Interfaces | USB 2.0 Full-Speed, RS-232 (115 kbps), Ethernet (10BASE-T) |
| Dimensions | 125 × 71 × 20 mm |
| Weight | 165 g |
| Operating Temperature | −20 to +60 °C |
| Power | +4 to +5.5 V DC, ≤2 W |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Model | Mini-X-OEM |
| X-ray Tube Type | Metal-Ceramic |
| Operating Voltage Range | 5–50 kV |
| Tube Current Range | 0–200 µA |
| Max Power | 4 W |
| Anode Material (Standard) | Au, Ag, or Rh |
| Anode Material (Optional) | W |
| Window Material | Be (125 µm) |
| Beam Spot Size | ~2 mm |
| Output Divergence Angle | 120° (5° with 2 mm collimator) |
| Input Voltage | 6–12 VDC |
| Input Current | 1.35 A (typ. @6 V), 0.70 A (typ. @12 V) |
| HV Stability | <0.1% |
| Cooling | Conductive (user-supplied heatsink required) |
| Operating Temperature | −10 °C to +60 °C (housing) |
| Humidity | 30–90% RH (non-condensing) |
| Weight | 340 g |
| Radiation Shielding | Integrated self-shielding (except output window) |
| Control Interface | Analog voltage inputs (0–4 V for kV/µA) and TTL logic outputs |
| Brand | Amptek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | OEM System Package |
| Form Factor | Handheld or Benchtop Configurable |
| Instrument Type | Conventional ED-XRF |
| Industry-Specific Design | Electronics Manufacturing & RoHS Compliance |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα (5.9 keV) |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| Detector | Silicon Drift Detector (SDD) with Peltier cooling |