Chemical Analysis Instruments
Filter
Showing 5221–5250 of 10779 results
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DDSJ-308F |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.000 µS/cm to 199.9 mS/cm |
| TDS Range | 0.000 mg/L to 99.9 g/L |
| Resistivity Range | 5.00 Ω·cm to 20.00 MΩ·cm |
| Salinity Range | 0.00–8.00 % |
| Temperature Range | −5.0 to 110.0 °C |
| Accuracy | ±0.5 % FS (Conductivity/TDS), ±0.1 % FS (Salinity), ±0.2 °C (Temperature) |
| Minimum Resolution | 0.001 µS/cm |
| Stability | ±0.3 % FS / 3 h |
| Temperature Compensation | Automatic or Manual (−5.0 to 135.0 °C) |
| Data Storage | 200 datasets per parameter (Conductivity, TDS, Salinity), GLP-compliant |
| Interface | USB |
| Power Backup | Non-volatile memory retention on power loss |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DDSJ-308F |
| Form Factor | Benchtop |
| Application | Laboratory |
| Conductivity Range | 0.000 µS/cm to 1000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.00 MΩ·cm |
| Salinity Range | (0.00–8.00)% |
| Temperature Range | −10.0 to 135.0 °C |
| Accuracy | ±0.5% FS (Conductivity, Resistivity, TDS), ±0.1% (Salinity), ±0.1 °C (Temperature) |
| Minimum Resolution | 0.001 µS/cm |
| Compliance | GLP-ready, supports ASTM D1125, ISO 7888, USP <645>, and IEC 61000-4 electromagnetic compatibility standards |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DDSJ-318T |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.000 μS/cm to 2000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | (0.00–8.00)% |
| Temperature Range | 0.00–100.00 °C |
| Accuracy | ±0.5% FS |
| Minimum Resolution | 0.001 μS/cm |
| Temperature Compensation Modes | None, Linear, Non-linear, Pure Water |
| Reference Temperatures | 5.0, 10.0, 15.0, 18.0, 20.0, 25.0 °C (default) |
| Electrode Constant Auto-Detection | Yes |
| Calibration Points | 1–5 points |
| IP Rating | IP54 |
| Data Storage Capacity | 1000 datasets |
| Compliance | GLP, GMP-supportive audit trail, FDA 21 CFR Part 11-ready data handling via optional software |
| Interfaces | RS-232, USB, U-disk support, barcode scanner compatibility, optional autosampler integration |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | DDSJ-318T |
| Detection Parameters | Single-Parameter (Conductivity, Resistivity, TDS, Salinity, Ash, Temperature) |
| Portability | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.000 µS/cm to 2000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | 0.00–8.00 % |
| Temperature Range | −10.0 to 135.0 °C |
| Accuracy | ±0.5 % FS (Conductivity/Resistivity/TDS), ±0.1 % FS (Salinity), ±0.1 °C (Temperature) |
| Minimum Resolution | 0.001 µS/cm (Conductivity), 0.01 Ω·cm (Resistivity), 0.001 mg/L (TDS), 0.01 % (Salinity), 0.1 °C (Temperature) |
| IP Rating | IP54 |
| Compliance | GLP, GMP (21 CFR Part 11-ready audit trail via software), ASTM D1125, ISO 7888, USP <645> |
| Key | Brand: Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DDSJ-318T |
| Form Factor | Benchtop |
| Application | Laboratory |
| Conductivity Range | 0.000 µS/cm to 2000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | 0.00–8.00 % |
| Temperature Range | −10.0 to 135.0 °C |
| Accuracy | ±0.5% FS (Conductivity/TDS/Resistivity), ±0.1% FS (Salinity), ±0.1 °C (Temperature) |
| Minimum Resolution | 0.001 µS/cm (Conductivity), 0.01 Ω·cm (Resistivity), 0.001 mg/L (TDS), 0.01% (Salinity), 0.1 °C (Temperature) |
| Compliance | GLP, GMP-ready, ASTM D1125, ISO 7888, USP <645>, EN 27888 |
| Connectivity | RS-232, USB, Optional Auto-sampler Interface |
| Data Storage | 1000 measurement records with audit trail |
| IP Rating | IP54 |
| Electrode Support | Automatic recognition of 0.01, 0.1, and 1.0 cm⁻¹ conductivity cells |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DDSJ-319L |
| Price Range | USD 700–1,400 |
| Measured Parameters | Conductivity, Resistivity, TDS, Salinity, Temperature |
| Form Factor | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0.000 µS/cm to 3000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | 0.00–8.00 % |
| Temperature Range | −5.0 to 130.0 °C |
| Accuracy | ±0.5 % of Full Scale (FS) for conductivity/resistivity/TDS |
| Minimum Resolution | 0.001 µS/cm (conductivity), 0.01 Ω·cm (resistivity), 0.001 mg/L (TDS), 0.01 % (salinity), 0.1 °C (temperature) |
| Compliance | GLP-compliant data management, supports ASTM D1125, ISO 7888, USP <645>, and China GB/T 6682 & GB/T 11025 standards |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Laboratory Conductivity Meter |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Conductivity Range | 0.000 µS/cm to 3000 mS/cm |
| TDS Range | 0.000 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | 0.00–8.00% (w/w) |
| Temperature Range | −5.0 to 130.0 °C |
| Accuracy | ±0.5% of full scale (FS) |
| Minimum Resolution | 0.001 µS/cm |
| Calibration | Up to 5-point conductivity calibration with auto-recognition of GB-standard reference solutions (4 preloaded) |
| Compensation Modes | Automatic temperature compensation (ATC), pure water conductivity correction, seawater salinity compensation |
| Connectivity | RS232/USB interface for PC and USB flash drive |
| Data Management | 1000 stored measurement records per parameter type |
| Software Compatibility | Leici LabSuite™ PC software (optional) for data export, statistical analysis, report generation, and 21 CFR Part 11–compliant electronic signatures |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DJS-0.1VTG |
| Conductivity Range | (2–20,000) µS/cm |
| Temperature Range | (0–80) °C |
| Accuracy | ±1.0% FS |
| Minimum Resolution | 0.01 µS/cm |
| Cell Constant | 0.1 cm⁻¹ |
| Probe Material | Borosilicate Glass |
| Connector | 5-pin Aviation Plug |
| Dimensions | Φ12 × 120 mm |
| Application | Lab-based Low-Conductivity Aqueous Solutions |
| Calibration Compatibility | 84 µS/cm and 146.5 µS/cm Standard Solutions |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DWS-51 |
| Instrument Class | 0.05 |
| Measurement Parameters | pNa (0.00–9.00), [Na⁺] (2.3×10⁻²–2.3×10⁷ µg/L) |
| Basic Electronic Error | ±0.02 pNa |
| Conversion Error (pNa ↔ [Na⁺]) | ±3% of reading |
| Temperature Compensation | Manual |
| Calibration Modes | Two-point (static/dynamic) |
| Display | Segment LCD |
| Power Supply | AC 220 V ±10%, 50 Hz ±2% |
| Dimensions (W×D×H) | 290×210×95 mm |
| Weight | 1.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | DZS-708L (EC-T Conductivity & Temperature Module Kit) |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.000 μS/cm to 3000 mS/cm |
| TDS Range | 0.00 mg/L to 1000 g/L |
| Resistivity Range | 5.00 Ω·cm to 100.0 MΩ·cm |
| Salinity Range | 0.00–8.00 % |
| Temperature Range | −10.0–135.0 °C (14.0–275.0 °F) |
| Accuracy | ±0.5 % FS (Conductivity/Resistivity/TDS), ±0.1 % FS (Salinity), ±0.3 °C (0.0–60.0 °C), ±1.0 °C (other ranges) |
| Minimum Resolution | 0.001 μS/cm (conductivity), auto-ranging |
| IP Rating | IP54 |
| Compliance | GLP-compliant data management, supports 21 CFR Part 11 audit trail via optional software configuration |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | EC-30 |
| Detection Parameters | Multi-Parameter (Conductivity, TDS, Salinity, Resistivity, Temperature) |
| Portability | Pen-Style |
| Intended Use | Laboratory & Field Applications |
| Conductivity Range | 0 μS/cm to 200.0 mS/cm (4 auto-ranging segments) |
| TDS Range | 0–50 ppt |
| Resistivity Range | 10 Ω·cm–99.99 kΩ·cm and 0.1 MΩ·cm–20 MΩ·cm |
| Salinity Range | 0–50 ppt |
| Temperature Range | (0.0–60.0) °C |
| Accuracy | ≤0.5% FS (full scale) |
| Minimum Resolution | 0.1 μS/cm |
| IP Rating | IP67 |
| Power Supply | 4 × AAA batteries (>200 h typical life) |
| Dimensions | 40 × 30 × 188 mm |
| Weight | ~0.15 kg |
| Display | High-contrast LCD with backlight |
| Auto-Temperature Compensation | 0.0–60.0 °C (default reference: 25 °C) |
| Calibration | 1–3 point, auto-identification of GB/US conductivity standards |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Electrode Design | Replaceable sensor tip |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Leici KDN-1 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 mg – 240 mg N |
| Steam Distillation Time | Programmable up to 60 min |
| Sample Weight Capacity | ≤6 g (solid), ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 mm × 385 mm × 735 mm |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | KLS-411 |
| Pricing Range | USD 570 – 2,850 (based on current exchange rate ~¥4000–¥20,000) |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg to 20 mg |
| Measurement Accuracy | ≤ ±3% RSD |
| Electrolysis Current Settings | 10 mA, 20 mA, 50 mA, 100 mA |
| Polarization Current Error | ±0.2 µA |
| Electrolysis Current Basic Error | ±0.5% of reading |
| Indication Error | ±(5% of calibration point + 3) µg |
| Repeatability | ≤3% RSD |
| Power Supply | (220 ± 22) V AC, (50 ± 1) Hz |
| Dimensions (L×W×H) | 300 × 235 × 100 mm |
| Net Weight | 3 kg |
| Interface | RS-232 serial port for printer connectivity |
| Electrode Configuration | Membrane-type dual-platinum electrode |
| Reagent Compatibility | Leici low-toxicity, low-odor, reusable KF reagent (coulometric anolyte/catholyte system) |
| Reagent Standardization | Not required (pre-calibrated reagent system) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | KLS-411 |
| Pricing | USD 1,650 (FOB Shanghai) |
| Titration Mode | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 10 µg to 20 mg |
| Measurement Accuracy | ≤ ±3% RSD |
| Electrolysis Current Settings | 10 mA / 20 mA / 50 mA / 100 mA |
| Polarization Current Error | ±0.2 µA |
| Electrolysis Current Basic Error | ±0.5% of reading |
| Indication Error | ±(5% of calibration point + 3) µg |
| Repeatability | ≤3% RSD |
| Power Supply | (220 ± 22) V, (50 ± 1) Hz |
| Dimensions (W×D×H) | 300 × 235 × 100 mm |
| Weight | 3 kg |
| Interface | RS-232 for printer and data export |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ORP-30 |
| Instrument Type | Laboratory-Grade Portable ORP Meter |
| ORP Measurement Range | −1000 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±15 mV |
| Repeatability | ≤3 mV |
| Calibration | Single-point with auto-recognition of 222 mV standard buffer |
| Temperature Range | 0.0–60.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Automatic Temperature Compensation (ATC) | 0.0–60.0 °C |
| Enclosure Rating | IP67 |
| Housing Material | ABS |
| Power Supply | 4 × AAA batteries |
| Battery Life | >200 h |
| Dimensions (L×W×H) | 188 × 40 × 30 mm |
| Weight | ~0.15 kg |
| Brand | Leici |
|---|---|
| Model | PH-30 |
| Type | Pen-Style pH Meter |
| Measurement Range | (-2.00 to 16.00) pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.02 pH |
| Repeatability | ≤0.01 pH |
| mV Range | -1000 to +1000 mV |
| mV Resolution | 1 mV |
| Temperature Range | (0.0 to 60.0) °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| ATC Range | (0.0 to 60.0) °C |
| Calibration Points | 1–3 point (auto-recognized GB & US buffers) |
| IP Rating | IP67 |
| Power | 4 × AAA batteries |
| Battery Life | >200 h |
| Dimensions | 40 × 30 × 188 mm |
| Weight | ~0.15 kg |
| Housing Material | ABS |
| Electrode Options | Spherical, Flat-Surface, or Conical pH Sensing Tips |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PH-30P |
| Instrument Type | Pen-Style pH Meter |
| Parameter Types | pH, mV, Temperature |
| pH Measurement Range | (-2.00 to 16.00) pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| pH Repeatability | ≤0.01 pH |
| mV Range | -1000 to +1000 mV |
| mV Resolution | 1 mV |
| Temperature Range | (0.0 to 60.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Automatic Temperature Compensation (ATC) | 0.0–60.0 °C |
| Calibration Points | 1–3 point with auto-buffer recognition (GB and US standard buffers) |
| IP Rating | IP67 |
| Housing Material | ABS |
| Power Supply | 4 × AAA batteries |
| Battery Life | >200 hours |
| Dimensions (L×W×H) | 188 × 40 × 30 mm |
| Weight | ~0.15 kg |
| Display | High-contrast LCD with backlight |
| Data Lock | Auto-lock (5–20 s adjustable) and manual hold |
| Auto-power-off | Configurable timer |
| Additional Functions | Factory reset, backlight adjustment, unit toggle (°C/°F) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PH-30Z |
| Instrument Type | Pen-Style pH Meter |
| Parameter Types | Multi-Parameter (pH, mV, Temperature) |
| pH Measurement Range | (-2.00 to 16.00) pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| pH Repeatability | ≤0.01 pH |
| mV Range | -1000 to +1000 mV |
| mV Resolution | 1 mV |
| Temperature Range | (0.0 to 60.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Automatic Temperature Compensation (ATC) | 0.0–60.0 °C |
| Calibration Points | 1–3 point with auto-buffer recognition (GB and US standard buffers) |
| Display | High-contrast LCD with backlight |
| IP Rating | IP67 |
| Electrode Options | Replaceable spherical, flat-surface, or conical pH sensing tips |
| Power | 4 × AAA batteries (>200 h battery life) |
| Dimensions | 40 × 30 × 188 mm |
| Weight | ~0.15 kg |
| Housing Material | ABS polymer |
| Included Accessories | Wrist strap, portable carrying case, calibration vials, pre-filled GB/US buffer solutions (pH 4.01, 7.00, 10.01), and batteries |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PHB-4 |
| Instrument Type | Portable |
| Parameter Types | Dual-parameter (pH/mV) |
| pH Accuracy | ±0.03 pH |
| pH Range | (0.00–14.00) pH |
| Resolution | 0.01 pH |
| mV Range | (−1400–+1400) mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.2% FS |
| Temperature Compensation | Manual |
| Calibration Solutions | GB Standard Buffers at pH 4.00, 6.86, and 9.18 |
| Calibration Points | 1–2 point |
| IP Rating | IP65 |
| Power Supply | Rechargeable Li-ion battery |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHB-4 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Range | (0.00–14.00) pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.03 pH |
| Calibration Standards | GB buffer solutions at pH 4.00, 6.86, and 9.18 |
| mV Range | (−1400–1400) mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.2% FS |
| Temperature Compensation | Manual |
| IP Rating | IP65 |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |
| Power | Rechargeable Li-ion battery |
| Brand | Leici |
|---|---|
| Model | PHB-4 |
| Type | Portable pH/ORP Meter |
| Measurement Range | 0.00–14.00 pH / −1400 to +1400 mV |
| Resolution | 0.01 pH / 1 mV |
| Accuracy | ±0.03 pH / ±0.2% FS |
| Temperature Compensation | Manual |
| Calibration | Up to 2-point, auto-recognition of Chinese standard buffers (pH 4.01, 6.86, 9.18) |
| Power | Rechargeable Li-ion battery (DC 5 V adapter included) |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | PHB-5 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH only) |
| Measurement Accuracy | ±0.01 pH |
| Measurement Range | −2.00 to 18.00 pH |
| Resolution | 0.01 pH |
| Calibration Solutions | GB Standard Buffers at pH 4.00, 6.86, and 9.18 |
| Auto-Detection | Yes (for standard buffer recognition) |
| Temperature Compensation | Automatic and Manual Modes |
| Power Supply | Rechargeable Li-ion Battery + AC Adapter |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | PHB-5 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.01 pH |
| pH Range | (-2.00 to 18.00) pH |
| Resolution | 0.01 pH |
| mV Range | (-1999 to 1999) mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | (-5.0 to 110.0) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Calibration Buffers | GB Standard Solutions at pH 4.00, 6.86, and 9.18 |
| Power Supply | Rechargeable Li-ion Battery + AC/DC Adapter (Input: AC 100–240 V, Output: DC 5 V) |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHB-5 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.01 pH |
| pH Range | −2.00 to 18.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | −5.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Calibration Buffers | GB Standard pH 4.00, 6.86, and 9.18 |
| Power Supply | Rechargeable Li-ion battery |
| AC/DC adapter (Input | AC 100–240 V, Output: DC 5 V) |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PHBJ-260 |
| Instrument Type | Portable |
| Parameter Type | Single-Parameter (pH only) |
| Measurement Range | −2.00 to 20.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | NIST-traceable Chinese national buffer solutions (pH 4.01, 6.86, 7.00, 9.18, 10.01) |
| Temperature Compensation | Automatic and Manual |
| Display | Backlit LCD (adjustable blue backlight) |
| Data Storage | Internal memory for calibration records and measurement logs |
| Connectivity | RS-232 serial interface (compatible with TP-16 printer and REX data acquisition software) |
| Protection Rating | IP65 |
| Power Supply | Battery-operated with low-battery indicator and auto-power-off function |
| Electrode Compatibility | Standard BNC connector |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | PHBJ-260 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| pH Resolution | 0.01 pH |
| pH Range | –2.00 to 20.00 pH |
| Accuracy | ±0.01 pH |
| mV Range | –2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS or ±0.3 mV |
| Temperature Range | –5.0 to 110.0 °C (23.0 to 230.0 °F) |
| Temp. Resolution | 0.1 °C/°F |
| Temp. Accuracy | ±0.2 °C |
| Calibration Standards | GB, DIN, NIST |
| Calibration Points | 1–5-point pH calibration |
| Data Storage Capacity | 500 datasets |
| Protection Rating | IP65 |
| Power Supply | Rechargeable Li-ion battery (DC5V input via AC adapter, USB-compatible charging) |
| Dimensions | 80 × 255 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHBJ-260 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| pH Measurement Range | (-2.00 to 20.00) pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | (-2000.0 to 2000.0) mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS or ±0.3 mV |
| Temperature Range | (-5.0 to 110.0) °C / (23.0 to 230.0) °F |
| Temperature Resolution | 0.1 °C / 0.1 °F |
| Temperature Accuracy | ±0.2 °C |
| Calibration Points | 1–5-point pH calibration |
| Buffer Recognition | Auto-identification of GB, DIN, and NIST standard buffer sets |
| Data Storage Capacity | 500 measurement records |
| Protection Rating | IP65 |
| Power Supply | Rechargeable Li-ion battery with USB-C/DC5V charging support |
| Dimensions (L×W×H) | 80 × 255 × 35 mm |
| Weight | 0.4 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHBJ-260 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/T) |
| Measurement Range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH ±1 digit |
| Temperature Compensation | Manual/Automatic (0–99 °C) |
| Display | Backlit LCD with blue illumination |
| Data Storage | 200 sets |
| Interface | RS-232 |
| IP Rating | IP65 |
| Power Supply | 4 × AA alkaline batteries |
| Buffer Options | Five selectable Chinese-standard pH calibration solutions |
| Measurement Modes | pH, mV (ORP), and temperature (−5.0–105.0 °C) |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | PHBJ-260F |
| Price Range | USD 420–690 |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter |
| pH Accuracy | ±0.01 pH |
| pH Measurement Range | −2.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −2000.0 to +2000.0 mV |
| mV Resolution | 0.1 mV |
| Temperature Range | −5.0 to 110.0 °C (23.0 to 230.0 °F) |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.2 °C |
| Calibration Standards Supported | GB, DIN, NIST |
| IP Rating | IP65 |
| Data Storage Capacity | 1000 datasets |
| Power Source | Rechargeable Li-ion battery (DC5V input via AC adapter or USB power bank) |
| Dimensions | 90 × 255 × 40 mm |
| Weight | 0.5 kg |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Model | PHBJ-260F |
| Instrument Type | Portable |
| Parameter Types | Multi-parameter (pH, mV, Temperature) |
| Measurement Accuracy | ±0.01 pH |
| pH Range | −2.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| mV Range | −2000.0 to 2000.0 mV |
| mV Resolution | 0.1 mV |
| Temperature Range | −5.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Calibration Standards Supported | GB, DIN, NIST |
| Protection Rating | IP65 |
| Data Storage Capacity | 1000 datasets |
| Power Supply | Rechargeable Li-ion battery (DC5V input compatible) |
| Dimensions | 90 × 255 × 40 mm |
| Weight | 0.5 kg |