| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% |
| Titration Mode | Fully Automatic Coulometric Titration |
| Sample Introduction | Direct liquid injection or optional oven coupling (e.g., 885 Compact Oven) |
| Compliance | Designed for GLP/GMP environments |
| Data Integrity | Audit-trail ready configuration available |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ECO IC |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Pump Pressure | 50 MPa |
| Flow Rate Range | 0.001–20.000 mL/min |
| Eluent Flow Rate Range | 0.001–20 mL/min |
| Maximum Operating Pressure | 35 MPa (5000 psi) |
| Operating Temperature Range | 20–50 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0–100% |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Automation Level | Fully Automated Titration |
| Moisture Range | 10 ppm to 100% (w/w) |
| Minimum Burette Delivery | 1/20,000 of burette volume |
| User Methods | 120 preconfigured methods |
| Display | Multilingual capacitive touchscreen (Chinese included) |
| Data Export | PDF reports via USB flash drive |
| Operating Modes | Expert Mode & Routine Mode with password protection |
| Solvent Handling | Integrated solvent pump for safe, contact-free reagent dispensing and burette filling/emptying |
| GLP Compliance | Audit-trail-ready reporting, electronic signature support, and traceable method execution |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | i-Raman NxG |
| Laser Options | 532 nm, 785 nm, or 1064 nm |
| Dual-Laser Configuration Available (i-Raman Duo) | 1064 nm + 860 nm |
| Software Platform | SpecSuite™ |
| Sample Interface | Fiber-optic probe compatible with vials, cuvettes, immersion probes, and fixed-stage holders |
| Compliance | Designed for GLP/GMP-aligned workflows, supports audit-trail-enabled data management per FDA 21 CFR Part 11 requirements |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm |
| Product Type | Portable / Handheld Raman Spectrometer |
| Model | i-Raman Plus |
| Spectral Range | 175–4000 cm⁻¹ |
| Spectral Resolution | 3.0 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Low-Wavenumber Cutoff | 65 cm⁻¹ |
| Spectral Reproducibility | <0.5 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | B&W Tek (distributed by Metrohm) |
| Instrument Type | Portable/HANDHELD Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | < 8.0 cm⁻¹ @ 912 nm |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 150 cm⁻¹ |
| Spectral Reproducibility | ≤ ±0.15 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Handheld Raman Spectrometer |
| Model | Mira P |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 12–14 cm⁻¹ (FWHM) |
| Minimum Wavenumber | 400 cm⁻¹ |
| Spectral Reproducibility | ≤0.15 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Handheld Raman Spectrometer |
| Model | MIRA XTR |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | 10 cm⁻¹ |
| Laser Wavelength | 785 nm |
| Database Size | >20,000 reference spectra |
| Standoff Distance | Up to 2 m |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (software-enabled), ISO/IEC 17025-compatible workflows |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multi Autolab/M204 |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 12 independent channels |
| Current Range | 10 mA to 10 nA (7 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Instrument |
| Model | OMNIS |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | –2400 to +2400 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.2 mV |
| Titration Resolution | 1 part in 100,000 |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Category | Imported Instrument |
| Model | OMNIS KF Oven |
| Instrument Type | Automated Sample Processor for Electrochemical Moisture Analysis |
| Maximum Heating Temperature | 300 °C |
| Sample Capacity | Up to 100 × 6 mL vials (unattended) |
| Compatible Vial Standards | ISO 8362 (2R–30R), plus standard 6 mL crimp-top and 8 mL screw-cap vials |
| Heating Modules | Configurable with 1 or 2 independent oven modules |
| Carrier Gas Options | Dry ambient air or nitrogen, with integrated large-capacity molecular sieve dryer |
| Needle Depth Adjustment | Motorized, programmable syringe needle extension for optimal vial penetration |
| Optional Integration | OMNIS Liquid Handling Module for automatic reagent replenishment (KF reagent and methanol) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Range | –2400 to +2400 mV |
| Accuracy | ±3 µg (for 10–1000 µg water) |
| Minimum Dispense Volume | 10 µg |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | OMNIS NIR |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Principle | Fixed-grating array-detector non-scanning design |
| Wavelength Range | 1000–2250 nm |
| Scan Speed | 300 spectra/s |
| Data Sampling Interval | 0.5 nm |
| Sample Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | OMNIS Platform |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PGSTAT 302F |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Multi-Channel Workstation |
| Current Range | 10 nA – 1 A |
| Current Accuracy | ±0.2% of reading or range |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 10 µHz – 1 MHz |
| Floating Mode Capability | Yes (dual-mode operation: grounded and floating) |
| Input Bias Current (25°C) | <1 pA |
| Potential Resolution | 300 nV |
| Current Resolution (at 10 nA range) | 30 fA |
| Compatible FRA Module | FRA32M (±2 A max output, ±30 V max output, 9 current ranges) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PGSTAT128N |
| Channel Configuration | Single-Channel Workstation |
| Current Range | 10 nA – 100 mA (7 decades) |
| Current Accuracy | ±0.2% of reading and range |
| Potential Range | ±10 V |
| Potential Accuracy | ±2 mV or ±0.2% of set value |
| Potentiostat Bandwidth | >500 kHz |
| Rise/Fall Time (1 V step, 10–90%) | <500 ns |
| Input Bias Current (25 °C) | <1 pA |
| Input Impedance | >100 GΩ |
| Coulometric Bandwidth | >4 MHz |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | Up to 50 kHz (standard), up to 750 kHz with ADC750 module |
| Potential Resolution | 150 µV (applied), 30/300 µV (measured) |
| Current Resolution | 0.0003% of range (e.g., 30 fA at 10 nA range) |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PRO Online NIR |
| Instrument Type | Online Process Analyzer |
| Application Field | Petrochemical Industry |
| Operating Principle | Fixed Grating with Diode Array Detector (Non-Scanning) |
| Wavelength Range | 1100–1650 nm (Reflectance), 850–1050 nm (Transmittance) |
| Scan Speed | 0.5 s per spectrum |
| Spectral Sampling Interval | 0.5 nm |
| Sample Interface Modes | Diffuse Reflectance (Solids), Transflectance (Liquids), Transmission (Liquids) |
| Chemometrics Software | Vision with ISIcal™ |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SECM |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | 10 pA – 100 pA |
| Current Resolution | 0.3 fA |
| Potential Accuracy | ±0.3 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Positioning System | XYZ Stepper Motor Control |
| Scan Volume (Standard) | 25 × 25 × 25 mm |
| Max Linear Scan Speed | 10 mm/s |
| Spatial Resolution | 20 nm |
| Operating Modes | Feedback Mode, Generation-Collection (GC) Mode, Direct Mode, AC-SECM (Local Impedance), 4D Mode, Shear-Force Mode |
| Scan Types | 2D, 3D, Equidistant, Fast Equidistant, User-Defined Electrochemical Protocol Scans |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SPELEC RAMAN |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% of full scale |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±4 V |
| AC Impedance Frequency Range | Not specified |
| Optical Detection Range | 350–1050 nm (UV/VIS spectrometer integrated) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Status | Imported |
| Model | SPELEC |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±4 V |
| EIS Frequency Range | 10 mHz – 1 MHz |
| Optical Detection Ranges | 200–900 nm or 350–1050 nm (user-selectable) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPELECNIR |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ±0.5 % of reading |
| Potential Accuracy | ±0.2 % of full scale |
| Potentiostatic Range | ±4 V |
| Impedance Frequency Range | Not applicable (dedicated EC–NIR coupling system, not EIS-capable) |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-1064 |
| Spectral Range | 176–2900 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Repeatability | ±1 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-N |
| Spectral Range | 176 – 2900 cm⁻¹ |
| Spectral Resolution | ~9 cm⁻¹ at 912 nm |
| Compliance | Designed for forensic field use in accordance with ISO/IEC 17025–aligned operational protocols |
| Software | Embedded spectral library with remote update capability |
| Detection Technology | Conventional Raman + optional SERS (via TacPac™ accessory) |
| Brand | Mapada |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | UV-6100S |
| Price Range | USD 7,000–10,000 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm (fixed) |
| Wavelength Setting | Automatic |
| Display | 320 × 240 LCD |
| Measurement Modes | Transmittance (T), Absorbance (A), Concentration (C), Energy (E) |
| Scan Speed Options | High/Medium/Low (up to 3800 nm/min) |
| Light Sources | Long-life imported tungsten lamp and deuterium lamp |
| Detector Type | Imported silicon photodiode |
| Interface | USB port for data export |
| Power Supply | AC 220 V / 50 Hz or AC 110 V / 60 Hz |
| Dimensions | 590 × 420 × 260 mm |
| Net Weight | 26 kg |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Electrochemical Workstation |
| Model | VIONIC |
| Current Range | ±6 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±6 A |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Compliance Voltage | ±50 V |
| Minimum Sampling Interval | 1 µs |
| Floating Mode | Optional |
| Dual Reference Electrode Support (S2) | Yes |
| Electrochemical Cell Isolation | Yes |
| Oscillation Protection | Yes |
| Independent Cell Switch | Yes |
| Brand | Metrolux |
|---|---|
| Origin | Germany |
| Model | ML6500 |
| Wavelength Range | 115–230 nm (single lamp), 115–320 nm (dual lamp: D₂ + Xe) |
| Spectral Resolution | < 1 nm FWHM at 160 nm |
| Wavelength Reproducibility | < 0.1 nm (validated at 121.5 nm and 160 nm) |
| Operating Pressure | < 1×10⁻⁵ mbar |
| Transmittance Accuracy | < ±0.3% |
| Reflectance Accuracy | < ±0.5% |
| Out-of-Band Transmittance | < 0.1% |
| Scattered Reflectance (157 nm) | > 0.001% |
| Diffuse Reflectance (157 nm, 1 mm aperture) | < 5% |
| Scattered Reflectance (157 nm, 1 mm aperture) | < 5% |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 10 µg – 200 µg |
| Measurement Accuracy | ±0.3 µg |
| Minimum Sample Injection Volume | 1 µL |
| Compliance | Fully compatible with GLP/GMP data integrity requirements (21 CFR Part 11 audit trail ready) |
| Electrode Options | Membrane-free and membrane-type electrolysis electrodes |
| Solvent Management | Integrated Solvent Manager with LevelSens level monitoring |
| Sample Introduction Modes | Direct injection, oven-based headspace extraction (up to 300 °C) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | C20S / C30S |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Charge Delivery | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Dosing Increment | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | C20S / C30S |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–capable (with LabX Server) |
| Electrode Options | Membrane-free or membrane-separated coulometric electrolysis cell |
| Interface | 7-inch full-color capacitive touchscreen with One Click™ UI |
| Language Support | English, Chinese, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese |
| Connectivity | USB 2.0 (printer, flash drive), Ethernet (TCP/IP), RS232 (optional) |
| User Management | 4-tier permission hierarchy with password protection and audit trail logging |
| Software Integration | LabX Express (standalone), LabX Server (networked, multi-instrument, compliant archiving) |
| Automation Ready | Compatible with InMotion KF Heating Oven Autosampler (C30S only) |
| Solvent Handling | Integrated Solvent Manager with automated reagent dispensing and waste evacuation |