Chemical Analysis Instruments
Filter
Showing 5761–5790 of 10742 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Display | Capacitive Touchscreen |
| Construction | Stainless Steel Housing |
| Dimensions (W×D×H) | 210 × 340 × 180 mm |
| Weight | ~6.5 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DispenSix |
| Measurement Range | −2000 mV to +2000 mV |
| Potentiometric Resolution | 0.1 mV |
| Potentiometric Accuracy | ±0.1 mV |
| Dispensing Precision | ±0.42 µL |
| Dispensing Resolution | 1/120,000 |
| Volume Range | 10 µL – 500 mL |
| Compliance | ISO 8655-3 |
| Brand | METTLER TOLEDO |
|---|---|
| Model | DL22 |
| Application Scope | Chloride, Ascorbic Acid, Iodine Value, Peroxide Value, Total Hardness, Free SO₂, Glucose, Kjeldahl Nitrogen, Reducing Sugars, Ca²⁺/Mg²⁺/K⁺, Organic Acids |
| Titration Modes | Endpoint & Equivalence Point Detection |
| Dispensing Modes | Dynamic & Fixed-Volume |
| Burette Resolution | 1/10,000 |
| Potential Resolution | 0.1 mV |
| Data Storage | 100 Sample Results |
| Stirring Options | Magnetic & Propeller |
| Burette Volumes | 1 mL, 5 mL, 10 mL, 20 mL |
| Compliance | GLP/GMP/FDA 21 CFR Part 11–Ready Reporting |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | OEM-Approved Thermal Analysis Accessories |
| Compatibility | DMA/SDTA 1+, TMA/SDTA 2+ Platforms |
| Regulatory Compliance | CE, ISO 9001–Certified Manufacturing |
| Software Integration | STARe Excellence Suite v16.0+ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Easy UV |
| Price | Upon Request |
| Wavelength Range | 190–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light (KCl, 198 nm) | ≤2.5% |
| Light Source | Xenon Flash Lamp |
| Optical Path Lengths | 10 mm, 16 mm, 20 mm, 30 mm, 40 mm, 50 mm (1 inch equivalent) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H×W×D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| Max. Stored Methods | 80 |
| User-Defined Quick Keys | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Colorimetric Standards | CIELAB, APHA, Gardner (30 pre-programmed color scales) |
| Compliance | Designed to support pharmacopeial workflows (USP <85>, EP 2.2.25, JP 2.04) |
| Connectivity | USB port for printer (USB-P25), barcode scanner (SQKitReader™), and peripheral storage |
| Sample Handling | Fixed cuvette holder (no autosampler or cuvette changer) |
| Application Scope | Quantitative analysis, spectral scanning, water quality testing (Spectroquant® integration), color measurement |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy VIS |
| Wavelength Range | 330–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Path Options | 10, 16, 20, 30, 40, 50 mm (1 inch) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H × W × D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| User-Defined Methods | Up to 80 |
| Quick Access Keys per User | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Barcode Reader Compatibility | SQKitReader™ handheld scanner (optional) |
| Printer Interface | USB-P25 |
| USB Host Port | Yes |
| Cuvette Changer | Not integrated |
| Pharmacopeia Compliance | Not specified |
| Colorimetric Standards | 25 pre-programmed methods (CIELAB, APHA, Gardner, etc.) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | ET08 |
| Moisture Range | 1 ppm – 100% (w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Resolution | 1/2000 of full stroke |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET18 |
| Instrument Type | General-purpose Potentiometric Titrator |
| pH Measurement Range | 1–14 |
| pH Meter Accuracy | ±0.2 |
| pH Resolution | 0.01 |
| Burette Precision | ±0.3% (v/v) |
| Compliance | Designed for GLP-compliant routine titration workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET28 |
| pH Range | 1–14 |
| pH Accuracy | ±0.2% of full scale |
| pH Resolution | 0.01 |
| Titration Precision | ±0.3% RSD |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Electrode Configuration | Integrated Ag/AgCl composite ring electrode |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET38 |
| pH Measurement Range | 1–14 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.2% of full scale |
| Titration Precision | ±0.3 µL per dispensing step |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Compliance | Designed for GLP/GMP-aligned laboratory workflows |
| Software Interface | iTitrate method-guided setup engine |
| Data Output | USB and RS232 connectivity for printer (e.g., USB-P25) and PC-based EasyDirect™ software integration |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET58 |
| Instrument Type | General-purpose Automatic Potentiometric Titrator |
| Measurement Range | ±2000 mV / (0–14) pH |
| Electrode Input Resolution | ±0.1 mV |
| Polarization Current Source | (0–5) µA, Resolution: ±0.1 µA |
| Temperature Input Range | (0–100) °C, Resolution: ±0.1 °C |
| Repeatability | 0.5% RSD |
| Dimensions (W×D×H) | 170 × 220 × 350 mm, Weight: 1.9 kg (unit only) |
| Display | 4.3″ color touchscreen (480 × 272 pixels RGB) |
| Power Supply | 24 VDC / 1.25 A |
| Input | 100–240 V AC ±10%, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH at 31 °C |
| Communication Interfaces | USB-A (high/low speed), USB-B (high/low speed) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Price Range | USD 700 – 7,000 (FOB) |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 hours |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 h |
| Origin | Switzerland |
|---|---|
| Model | EM120 |
| Maximum Capacity | 124 g |
| Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost function (140% target temperature for first 3 min) |
| Termination Criteria | Automatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Stored Methods | 5 user-defined profiles |
| Security | Password-protected settings, physical lock slot |
| Interface | RS232 |
| Firmware Update | Network-enabled via PC connection |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET Series (ET08/ET12/ET15/ET18/ET28/ET38/ET58) |
| Type | Benchtop Automatic Potentiometric Titrator |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Interface | EasyDirect™ (PC-based), iTitrat™ intelligent calculation engine |
| Titration Drive Resolution | 12,000 steps per full stroke |
| Display | Capacitive touchscreen interface |
| Liquid Handling | Motorized burette with programmable dosing modes (fixed-volume dispensing, manual titration assist, auto-titration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET08 |
| Instrument Type | Coulometric & Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | 100 ppm – 100% (w/w) |
| Voltage Input Range | 0–2000 mV |
| Polarization Current Resolution | ±0.1 µA |
| Minimum Detectable Water Content | 100 ppm |
| Dimensions (W×D×H) | 170 × 220 × 350 mm |
| Weight | 1.9 kg (instrument only), +0.8 kg (magnetic stirrer base) |
| Display | 4.3-inch RGB touchscreen (480 × 272 pixels) |
| Power Supply | 24 VDC / 1.25 A |
| Input | 100–240 VAC ±10%, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH at 31 °C |
| Communication Interfaces | USB-A (high/low speed), USB-B (high/low speed) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured globally per ISO 9001-certified facilities) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Automation | Fully integrated InMotion™ KF Autosampler with programmable heating oven (50–250 °C) |
| Sample Capacity | 26 positions on 25 cm footprint |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP-ready with 21 CFR Part 11 audit trail capability |
| Data Management | Built-in One Click™ workflow automation, METTLER TOLEDO LabX® software compatibility |
| Brand | METTLER TOLEDO |
|---|---|
| Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 1 µg – 200 mg H₂O |
| Detection Limit | ≤ 0.1 µg H₂O |
| Electrode Recognition | Integrated Smart Chip Interface |
| Cell Design | Modular Two-Part Coulometric Titration Vessel |
| Optional Accessories | Amber Cell, Thermostatted Cell, InMotion KF Oven Integration |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP Data Integrity Ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm to 100% |
| Measurement Resolution | ±2300 mV / 0.1 mV |
| Detection Limit | 0.1 µg H₂O |
| Minimum Water Delivery | 0.2 mg per sample (RSD ≤ 1%) |
| Titration Precision | 120,000 steps |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | FDA 21 CFR Part 11, ISO/IEC 17025, ASTM E203, USP <921>, EP 2.5.12 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured in METTLER TOLEDO facilities) |
| Instrument Type | Volumetric Karl Fischer Titrator with Integrated Heated Autosampling System |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP-ready |
| Sample Capacity | 26 positions (heated sample carousel) |
| Temperature Control Range | Ambient to 150 °C (adjustable per vial) |
| Titration Resolution | 0.001 mL reagent dispense |
| Reagent Delivery | Dual-piston burette with integrated moisture-tight sealing |
| Software Platform | LabX® with 21 CFR Part 11 compliance, audit trail, electronic signatures |
| Connectivity | Ethernet, USB, RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V1 |
| Pricing Range | USD 19,500 – 22,000 (FOB) |
| Titration Principle | Volumetric Coulometric/KF Endpoint Detection via Bipotentiometric Electrode System |
| Dispensing Resolution | 120,000 steps per burette revolution |
| Control Algorithm | Fast Feedback Algorithm (FFA) for dynamic reagent dosing |
| Software Platform | LabX™ PC-based titration software with audit trail and electronic signature support |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EVA V1/V3 |
| Application Scope | Liquid and soluble solid samples |
| Titration Principle | Volumetric Karl Fischer (Iodine-based redox titration) |
| Electrode Type | Digital polarizable dual-platinum electrode |
| Control Algorithm | Fast Forward Algorithm (FFA) for real-time current-based endpoint prediction |
| Sample Weight Transfer | Direct integration with METTLER TOLEDO balances via RS232/USB |
| Data Export | CSV, PDF via Ethernet or USB drive |
| Printer Support | METTLER TOLEDO thermal & dot-matrix printers (A4/letter) |
| Software Platform | LabX™ PC-based software with optional Active Directory integration |
| Security Features | User-level access control, audit trail, 21 CFR Part 11–compliant electronic signatures (with LabX validation package) |
| Solvent Handling | Fully automated solvent exchange and burette purging |
| Optional Accessories | Homogenizer kit, micro-vial holders, 2.5 m remote terminal cable for fume hood operation |
| Reproducibility | ≤0.3% RSD for triplicate analysis under GLP conditions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V3 |
| Pricing Range | USD 24,000 – 27,000 (FOB) |
| Titration Principle | Volumetric Karl Fischer (KF) |
| Electrode Type | Dual-platinum generator and indicator electrodes |
| Reagent Delivery Precision | ±0.001 mL per 120,000-step motorized burette |
| Sample Throughput | Up to 30 samples per hour (with autosampler option) |
| Compliance | Fully compatible with FDA 21 CFR Part 11, ISO/IEC 17025, and GLP/GMP data integrity requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | FE20 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| Relative pH Accuracy | ±0.01 |
| mV/ORP Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| Relative mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 pre-defined buffer sets |
| Display | LCD |
| Power Supply | External AC adapter |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE20K |
| Instrument Type | Benchtop (not portable) |
| Parameter Type | Single-parameter (pH/mV/ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with auto-buffer recognition for 4 pre-defined IUPAC/NIST-compatible buffers |
| Data Storage | 99 measurement records |
| Interface | RS232 |
| Display | Backlit LCD showing pH/mV value, temperature, endpoint status, and calibration indicators |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 / S210-K |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + mV/ORP) |
| pH Range | −2.00–16.00 pH (FE28) / −2.000–20.000 pH (S210-K) |
| pH Resolution | 0.01 pH (FE28) / 0.001–0.1 pH selectable (S210-K) |
| pH Accuracy | ±0.01 pH (FE28) / ±0.002 pH (S210-K) |
| mV Range | ±2000 mV (FE28) / ±2000.0 mV (S210-K) |
| mV Resolution | 1 mV (FE28) / 0.1 or 1 mV selectable (S210-K) |
| mV Accuracy | ±1 mV (FE28) / ±0.2 mV (S210-K) |
| Temperature Range | −5 to 105 °C (FE28, manual/auto) / −30.0 to 130.0 °C (S210-K, manual) |
| Temperature Accuracy | ±0.1 °C (S210-K) |
| Calibration Points | Up to 5-point pH calibration |
| Buffer Recognition | Automatic (NIST, DIN, JIS, ISO, METTLER TOLEDO standard buffers) |
| Data Storage | 200 measurement records |
| Connectivity | RS232 and USB |
| Electrode Interface | Standard BNC (FE28) / ISM-enabled Smart Socket (S210-K) |
| Temperature Compensation | Automatic and manual |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Meter |
| Instrument Type | Portable |
| Parameter Types | pH, Conductivity, Dissolved Oxygen |
| pH Measurement Range | −2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 (at 25 °C) |
| pH Calibration Points | Up to 5 |
| Predefined Buffer Sets | 4 |
| Temperature Range | 0 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Data Storage | 200 measurement records + active calibration data |
| Interface | RS232 and USB |
| Reference Input | Yes |
| Audible Signal | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Italy |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV (single-channel) |
| pH Measurement Range | -2 to 16 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| mV Measurement Range | 0 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 |
| Temperature Range | -5 °C to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Data Storage Capacity | 200 measurements |
| Connectivity | RS232 and USB |
| Electrode Included | LE438 pH electrode |
| ISM Support | Not supported |
| Calibration Solution Compatibility | China-specific calibration buffers |
| Compliance | Designed for GLP-compliant routine lab use |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Standard |
| Instrument Type | Benchtop (not portable — corrected per technical specification) |
| Parameter Types | pH, mV, Temperature |
| Measurement Range | -2.00 to 16.00 pH |
| Resolution | 0.01/0.1 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.3 °C |
| Temperature Compensation | Automatic and Manual |
| Calibration Points | Up to 5-point |
| Calibration Modes | Linear and Segmented |
| Predefined Buffers | 4 sets (including US, NIST, DIN, and Chinese standards) |
| Data Storage | 200 measurement records + current calibration data |
| Connectivity | BNC, Cinch, NTC 30 kΩ, RS232, USB |
| Display | 4.3-inch segmented LCD |
| Housing Material | ABS |
| Dimensions / Weight | 227 × 147 × 70 mm / 0.63 kg |
| Power Supply | 100–240 V AC, 50–60 Hz / 12 V DC |
