Chemical Analysis Instruments
Filter
Showing 5791–5820 of 10458 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | microPHAZIR AS |
| Price Range | USD 70,000–140,000 (FOB) |
| Principle | Portable, Non-Contact Reflectance NIR Spectroscopy |
| Measurement Time | <10 s |
| Sampling Mode | Non-Contact Diffuse Reflectance |
| Weight | 1.25 kg |
| Housing | Ruggedized Dust-Resistant Polymer Enclosure |
| Light Source | Tungsten-Halogen Lamp (Class 1 LED-equivalent Safety) |
| Data Interface | Internal Flash Memory + USB 2.0 Host Interface |
| Operating Temperature | 5–40 °C (non-condensing) |
| Power Supply | Dual Hot-Swappable Li-ion Batteries (4.5 h typical runtime) |
| Optional Accessories | AC Battery Charger, Carrying Case with Belt Clip |
| Brand | Microphotons |
|---|---|
| Origin | Imported |
| Manufacturer Type | OEM Manufacturer |
| Model | C3A-2700LAE |
| Pricing | Upon Request |
| Model | 318C+ |
|---|---|
| Price | Upon Request) |
| [Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | 318C+ |
| Wavelength Range | 350–800 nm |
| Filter Positions | 10 (standard: 405, 450, 492, 630 nm |
| Absorbance Range | 0.000–4.000 A |
| Optical Channels | 8-sample + 1 optional reference channel |
| Absorbance Stability | ≤ ±0.002 A or ≤ 0.5% T / 10 min |
| Accuracy | ≤ ±0.005 A or ±0.2% T |
| CV (Repeatability) | ≤ 0.2% |
| Sensitivity | ≥ 0.01 L/mg |
| Channel Uniformity | ≤ 0.01 A |
| Wavelength Accuracy | ±1 nm |
| Bandwidth (FWHM) | ≤ 8 nm |
| Display Resolution | 0.001 A (display), 0.0001 A (internal calculation) |
| Read Time | ≤3 sec/96-well (single wavelength), ≤6 sec/96-well (dual wavelength) |
| Plate Types | Standard 96-well microplates, strips, flat/U/V-bottom wells |
| Display | 7-inch color TFT-LCD touchscreen |
| Input | Touchscreen + optional USB mouse/keyboard |
| Built-in Thermal Printer | Yes |
| Data Storage | ≥200,000 assay results, ≥500 test protocols (expandable) |
| Interfaces | USB-A, USB-B, RS-232, parallel port |
| Operating Environment | 5–40 °C, 15–80% RH |
| Power Supply | 220 V ±10%, 50/60 Hz |
| Dimensions (L×W×H) | 475 × 350 × 210 mm |
| Weight | 11.5 kg] |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | MIDAC Dynamic Calibration System |
| Price Range | USD 42,000 – 70,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatography Calibration Standard Generator |
| Application Scope | Universal Calibration for GC & FTIR |
| Gas Dilution Stages | Triple-stage |
| Mass Flow Controllers (MFCs) | Multi-channel digital MFC support |
| Corrosive Gas Compatibility | Yes (acidic, alkaline, organic) |
| Dilution Ratio Programmability | Yes, time-scheduled auto-run |
| Real-time Flow Monitoring | Yes |
| Repeatability | ≤ ±0.8% RSD (N₂ baseline, 10–1000 sccm) |
| Control Interface | PLC-based with 7″ TFT touchscreen (800×600) |
| PLC Cycle Time | Standard mode 160 µs |
| Onboard Memory | Display buffer 26 MB |
| Touchscreen Lifetime | ≥ 5 years (MTBF) |
| Brand | GAOMAI |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | I-Series |
| Instrument Type | Online FTIR Spectrometer |
| Wavenumber Range | 4000–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Scan Speed | 8 s per spectrum |
| Signal-to-Noise Ratio | <1% (RMS, 100 scans) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ across 4000–7500 cm⁻¹ |
| Brand | MILESTONE |
|---|---|
| Origin | Italy |
| Model | DMA-1 |
| Instrument Type | Portable |
| Measurement Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.1 ng |
| Linear Range | 0–1500 ng |
| Repeatability (RSD) | ≤1.0% |
| Linearity Error | ±10% |
| Sample Throughput | 2–5 min per analysis |
| Regulatory Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | Milestone |
|---|---|
| Origin | Italy |
| Model | DMA-80 evo |
| Principle | Catalytic Thermal Decomposition – Gold Amalgamation – Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 0.0002 ng |
| Linear Range | 0–30,000 ng |
| Repeatability (RSD) | ≤1.0% |
| Recovery Rate | >98.5% at 1000 ng |
| Compliance | EPA Method 7473, HJ 923–2017, GB 5009.17–2021 |
| Brand | Chengmeng Technology |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Millicell® ERS 3.0 |
| Price | Upon Request |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | JC-2 |
| Compliance | GB/T 479 |
| Temperature Control Range | Ambient to 1100 °C |
| Control Accuracy | ±1 °C |
| Heating Rate | 30 min to 250 °C |
| Temperature Measurement Error | ±3 °C |
| Temp. Resolution | 1 °C |
| Timer Range | 0–999 min |
| Timing Accuracy | ±1 min |
| Time Resolution | 1 min |
| Heating Element | Silicon Carbide Rods |
| Thermocouple Type | K-type |
| Total Power Rating | 2 × 4 kW |
| Continuous Operation | 24 h |
| Recording Drum Linear Speed | 1 mm/min (±2 mm over 160 min) |
| Cold-Junction Compensation | 0–60 °C |
| Power Supply | 220 V ±10 %, 50 Hz ±2 % |
| Host Dimensions (L×W×H) | 800 × 400 × 580 mm |
| Controller Dimensions | 330 × 290 × 120 mm |
| Host Weight | 96 kg |
| Controller Weight | 7 kg |
| Key | Brand: MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | JC-9 |
| Temperature Range | 0–999 °C (Accuracy Class 0.5, Resolution: 1 °C, K-type Thermocouple) |
| Timer Range | 0–999 min |
| Heating Rate Control | 3 °C/min from 250 °C to 730 °C within 30 min |
| Time Accuracy | ±30 s per 24 h |
| Time Resolution | 0.1 min |
| Power Consumption | 4 kW |
| Supply Voltage | 220 V, 50 Hz |
| Net Weight | 150 kg |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | MSSC-5000 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Drying Methods | Microwave, Infrared, or Combined |
| Microwave Power | Adjustable via software |
| Sample Mass (Total Moisture) | 10–12 g, weighed to 0.001 g |
| Sample Mass (Analytical Moisture) | 1.45–1.55 g, weighed to 0.0001 g |
| Balance Resolution | 0.0001 g |
| Balance Capacity | 0–195 g |
| Total Moisture Drying Time | 12–15 min (adjustable) |
| Analytical Moisture Drying Time | ~10 min (adjustable) |
| Max. Sample Capacity per Batch | 9 specimens |
| Particle Size (Total Moisture) | <6 mm |
| Particle Size (Analytical Moisture) | ≤80 mesh |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (L×W×H) | 480 × 350 × 540 mm |
| Net Weight | 35 kg |
| Brand | Minik |
|---|---|
| Model | MS210 |
| Origin | Beijing, China |
| Category | Other Chromatography Instruments |
| Application | Pre-analytical vaporization of liquid hydrocarbons for GC and coulometric Karl Fischer analysis |
| Compliance | GB/T 3727–2003, GB/T 6023–2008 |
| Liquid Inlet Pressure | 0.69–2.75 MPa |
| Output Flow Rate | 0–5 L/min (adjustable) |
| Vaporization Temperature Range | Up to 230 °C |
| Heating & Jacket Temperature Control Range | Ambient +5 °C to 230 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Mass Flow Control Range | 0–100 mL/min |
| Flow Resolution | 0.1 mL/min |
| Sample Introduction | Liquid or gas phase |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiniSAXS |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| Measurement Range | 1 nm – 100 nm |
| Available Anode Materials | Cu, Mo, Ag |
| Collimation | Pinhole-based collimation system |
| Filtration | Integrated beam filtration unit |
| Sample Stage | Motorized 3-axis stage with 16-position powder holder and 16-position solid-sample holder |
| Detector | Two-dimensional silicon pixel array single-photon counting detector |
| Pixel Size | 75 µm × 75 µm |
| Readout Mode | Continuous, zero dead time, no readout noise or dark current |
| Dynamic Range | 32-bit |
| Sample-to-Detector Distance (SD) | 40 mm – 350 mm |
| Scattering Vector (q) Range | 0.063 nm⁻¹ – 6.3 nm⁻¹ |
| Dimensions (W×D×H) | 840 mm × 750 mm × 700 mm |
| Power Supply | AC 220 V, 50 Hz (single-phase) |
| Supported Techniques | SAXS, WAXS, GIWAXS, GISAXS |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600 |
| Instrument Type | Linear Ion Trap Mass Spectrometer |
| Chromatography Configuration | Low Thermal Mass (LTM) Gas Chromatograph |
| Mass Range | 15–550 m/z |
| Scan Speed | 10,000 Da/s |
| Mass Accuracy | High (typical ≤ 0.2 Da RMS error under calibration) |
| Oven Ramp Rate | Up to 30 °C/s |
| Detection Limit | Sub-ppt (v/v) for target VOCs in air matrix |
| Dimensions | 420 × 320 × 210 mm |
| Weight | <12.5 kg |
| Sample Introduction | Direct gas, headspace, liquid injection, and thermal desorption (solid-phase microextraction compatible) |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600 |
| Origin | Shandong, China |
| Instrument Type | Portable GC-MS |
| Mass Range | AMU (atomic mass units) |
| Dynamic Range | 7 decades |
| Mass Resolution | <1.0 amu at FWHM |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Tandem MS (MS/MS) |
| Sensitivity | 10× higher than conventional portable GC-MS systems |
| Weight | Not specified |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600Plus |
| Mass Range | 15–550 Da |
| Scan Speed | 10,000 Da/s |
| Mass Analyzer Type | Linear Ion Trap |
| Detection Principle | Electron Ionization (EI) with Inert High-Temperature Ion Source |
| Sample Introduction | Triple-mode (Gas, Liquid, Solid) |
| Compliance | GB/T 11606–2007, GB/T 32210–2015, GJB 150.16A–2009, HJ 1223–2021, HJ 1227–2021 |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 Da |
| Dynamic Range | 7 decades |
| Mass Resolution | Unit Mass Resolution |
| Maximum Scan Rate | 10,000 scans/s |
| Sensitivity | sub-ppt (gas-phase VOCs) |
| Weight | <18 kg |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | Not Specified (AMU) |
| Dynamic Range | 7 decades |
| Mass Resolution | <1.0 amu at FWHM |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Tandem MS (MS/MS) |
| Sensitivity | ~10× higher than conventional portable GC-MS for ODS compounds |
| Weight | Not Specified (kg) |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | MT-CNE200 |
| Price | Upon Request |
| Functionality | Electrode Fabrication & Thermal Annealing |
| R<sub>G</sub> Ratio | As low as 1.1 |
| Template Material | Fused Silica Quartz |
| Tip Diameter Range | 10 nm – 50 µm (Optimized for 200–500 nm) |
| Electrode Types | Carbon Nanoelectrodes, Carbon Micronelectrodes, Carbon Nanotip Electrodes, Derivative Electrodes (Metallic Nanoelectrodes, Metal Oxide Nanoelectrodes) |
| Dimensions | 480 × 340 × 320 mm |
| Weight | ~20 kg |
| Brand | MinTech |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | MT-PSAM/IMMS100 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPO5 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPO5 |
| Pricing | Upon Request |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORION CH4 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | ORION NH3 |
| Pricing | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ORION CO₂ CH₄ |
| Pricing | Available Upon Request |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1015-IV |
| Power Supply | AC 198–242 V, 49–51 Hz |
| Equivalent Output Voltage Range | 0–220 V |
| Heating Power | 350 W |
| Display | 3.5-digit segmented LCD |
| Control Core | 8-bit microcontroller |
| Mains Compensation | Yes (voltage-fluctuation compensation via proportional heating control) |
| Triggering Method | Zero-crossing solid-state switching |
| Compliance | GB/T 260, ASTM D95 |
| Measurement Result Format | mass percent (%) |
| Operating Environment | Ambient temperature |
| Power Consumption | 350 W |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Moisture Range | 10 µg – 100 mg H₂O |
| Precision | CV ≤ 0.3% for samples ≥ 1 mg (n = 10) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Electrolysis Current | 430 mA |
| Average Titration Speed | 2.2 mg H₂O/min (36 µg/sec) |
| Display | 5.7-inch color LCD |
| Data Storage | 20 user-defined methods × 50 sub-files each |
| Compliance | GLP/GMP-ready with audit trail support (via optional RS-232C or USB export) |
| Optional Accessories | VG-200 gas vaporization unit, membrane/no-membrane generator electrodes, reagent dispensing module |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Water Content Range | 10 µg – 100 mg H₂O |
| Accuracy | ≤ 0.3% RSD (for ≥1 mg H₂O, n=10) |
| Minimum Dispensing Volume | 1/2000 of burette volume |
| Electrolysis Current | 430 mA |
| Average Titration Speed | 2.2 mg H₂O/min |
| Display | 5.7-inch color LCD |
| Data Storage | 20 user-defined methods × 50 sub-files each |
| Interface | RS-232C (optional), USB storage port, balance input |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Dimensions (Analyzer) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |