Chemical Analysis Instruments
Filter
Showing 5641–5670 of 10742 results
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | V-5100 |
| Price Range | USD 700–1,400 (FOB Shanghai) |
| Optical System | Single-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 2 nm or 4 nm (selectable) |
| Stray Light | ≤0.1% T |
| Wavelength Scanning Mode | Automatic |
| Display | 128 × 64 dot-matrix LCD |
| Data Storage Capacity | 200 measurement sets & 200 calibration curves |
| Data Output | USB interface + parallel printer port |
| Lamp Type | Plug-in tungsten halogen lamp |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | V-5100B |
| Optical System | Single-beam |
| Detector | Silicon Photocell |
| Wavelength Range | 320–1000 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 2 nm or 4 nm (selectable) |
| Stray Light | ≤0.1% T |
| Display | 128×64 dot-matrix LCD |
| Data Storage | 200 measurement sets + 200 calibration curves |
| Wavelength Control | Motorized auto-scanning with self-calibration |
| Output Interfaces | USB port + parallel printer port |
| Software Compatibility | Optional Metash Quantitative Analysis Suite (supports photometric analysis, kinetics, multi-wavelength scanning, DNA/protein quantification) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | V-5600(PC) |
| Instrument Architecture | Dual-Beam Ratio-Monitoring Optical System |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Automation Level | Automatic Wavelength Scanning & Calibration |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.05% T at 220 nm and 360 nm |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | V-5800 |
| Instrument Architecture | Dual-beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | X-6 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.3% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A) |
| Photometric Repeatability | ≤0.15% T (0–100% T), ≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1.0 A) |
| Baseline Drift | ±0.001 A/h at 500 nm |
| Baseline Flatness | ±0.002 A |
| Noise Level | ≤0.4% T |
| Photometric Range | 0–200% T, –3.0 to +3.0 A, 0–9999 C |
| Data Interfaces | USB port, USB flash drive support, optional Bluetooth module, A4 inkjet printer interface |
| Display | 7-inch high-resolution capacitive touchscreen |
| Light Sources | Imported long-life tungsten lamp and deuterium lamp |
| Dimensions | 505 × 375 × 190 mm |
| Weight | 15.5 kg |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | X-6D |
| Optical System | Dual-beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05%T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | X-6DS |
| Optical System | Dual-beam |
| Detector | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Automation | Motorized |
| Spectral Bandwidth | 0.8 / 1.8 / 4.0 / 5.0 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05%T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | X-7 |
| Optical System | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T |
| Photometric Range | 0–200% Transmittance, –4.0 to +4.0 Absorbance, 0–9999 Concentration Units |
| Display | 10-inch capacitive multi-touch TFT LCD |
| Data Interface | USB 2.0 (for printer, flash drive, and PC connectivity) |
| Lamp Source | Imported long-life tungsten and deuterium lamps |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | X-7S |
| Optical Design | Pseudo-Double-Beam |
| Detector | Silicon Photodiode |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1.0 A) |
| Photometric Repeatability | ≤0.1% T, ≤0.001 A (0–0.5 A), ≤0.002 A (0.5–1.0 A) |
| Baseline Drift | ±0.0005 A/h at 500 nm |
| Baseline Flatness | ±0.001 A |
| Noise Level | ±0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Display | 10-inch capacitive multi-touch TFT color screen |
| Data Interface | USB 2.0 (host and device) |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions (W×D×H) | 460 × 380 × 180 mm |
| Weight | 20 kg |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | X-8 |
| Wavelength Range | 190–1100 nm |
| Optical System | Dual-beam |
| Detector Type | Silicon Photocell |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.15 nm |
| Stray Light | ≤0.03%T |
| Photometric Repeatability | ≤0.1%T |
| Noise Level | ≤0.4%T |
| Display | 10-inch capacitive touchscreen (1024 × 600 resolution, <3 ms response time) |
| Data Interfaces | USB, Bluetooth, Wi-Fi (optional) |
| Lamp Type | Plug-in deuterium and tungsten lamps |
| Base Material | 20 mm machined aluminum optical bench |
| Compliance | GLP/GMP-aligned software architecture, audit-trail-ready user management |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | X-8D |
| Optical System | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Automation Level | Automatic Wavelength Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03%T |
| Photometric Accuracy | ±0.3%T (0–100%T) |
| Photometric Repeatability | ≤0.1%T (0–100%T) |
| Noise Level | ≤0.3%T |
| Display | 10-inch HD True-Color Touchscreen |
| Data Output | USB, U-disk, Bluetooth (optional), A4 Inkjet Printer (HP 1100/1200 series compatible) |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | X-8DS |
| Optical System | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (5-step adjustable) |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.03% T |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | X-8S |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.15 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm |
| Stray Light | ≤0.03%T |
| Display | 10-inch capacitive touchscreen (1024 × 600 resolution) |
| Data Interfaces | USB, Bluetooth, Wi-Fi (optional) |
| Compliance | GLP/GMP-ready software architecture |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | X-9D |
| Price Range | USD 9,800 – 13,900 (FOB Shanghai) |
| Optical Design | Dual-beam |
| Detector | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.01%T |
| Photometric Repeatability | ≤0.1%T (0–100%T) |
| Noise Level | ≤0.3%T |
| Display | 10-inch capacitive touchscreen (1024 × 600) |
| Connectivity | USB, Bluetooth, Wi-Fi (optional) |
| Data Output | A4 printer support (inkjet/laser), customizable file naming, GLP-compliant audit trail |
| Brand | Metash Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | X-9DS |
| Optical System | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 4.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Stray Light | ≤0.01%T |
| Origin | USA |
|---|---|
| Manufacturer | METEK GmbH (Germany), Distributed in North America |
| Instrument Type | Imported High-Precision Turbulence-Grade 3D Ultrasonic Anemometer |
| Model | uSonic-3 Cage MP / uSonic-3 Class A MP |
| Sampling Rate | Up to 30 Hz per transducer pair (90 Hz total radial data rate) |
| Wind Speed Range | ±40 m/s |
| Operating Temperature | −40 °C to +60 °C |
| Relative Humidity | 5–100 % RH |
| Wind Accuracy | ±0.5–1 % RMS @ 5 m/s (horizontal, 0°–20° sector) |
| Vertical Velocity Resolution | 0.006 m/s |
| Temperature Resolution | 0.01 K |
| Output Data | 9 radial wind components, 9 sonic temperature values, Cartesian (u, v, w), scalar wind speed & direction, turbulence statistics (with optional module) |
| Communication | RS422, RS485 (300–115.2 kbaud), 10/100 Mbit Ethernet (ASCII protocol, NMEA-compliant framing, checksum support) |
| Power | 10–36 VDC, 2.5 W (heating optional: 10–24 VDC, ≤100 W) |
| Mounting Options | Cage-mount (Cage MP) or Class A meteorological mast mount (Class A MP) |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ES-2 |
| Measurement Parameter | Single (Electrical Conductivity) |
| Form Factor | Pen-style |
| Deployment Environment | In-pipe, in-tank, and pore-water applications |
| EC Range | 0–120 dS/m |
| TDS Range | Derived from EC (default 0.5–0.7 conversion factor) |
| Resistivity Range | 0.0083–1000 kΩ·cm (calculated inverse) |
| Salinity Range | 0–60 ppt (based on PSS-78 standard) |
| Temperature Range | –40 to +60 °C |
| Accuracy | EC: ±0.01 dS/m or ±10% (whichever is greater) |
| Temp | ±1 °C |
| Resolution | EC: 0.001 dS/m |
| Temp | 0.1 °C |
| Output Protocol | SDI-12 or DDI serial |
| Compatible Data Loggers | METER ZL6 series or any SDI-12–compliant logger with 3.6–15 VDC excitation |
| Dimensions | 10.9 cm (L) × 2.4 cm (W) |
| Cable | 5 m standard (custom up to 75 m) |
| Connector | 3.5 mm stereo jack or tinned leads |
| Power Supply | 3.6–15 VDC |
| Current Draw | 20–28 mA (active), 0.03 mA (standby) |
| Startup Time | 100–250 ms (SDI-12 dependent) |
| Measurement Duration | 25–50 ms |
| Compliance | ISO 9001:2015 certified manufacturing |
| CE marked per EM directive EN ISO/IEC 17050 | 2010 |
| Mechanical Interface | 1-inch NPT threaded body with optional T-fitting for pipe mounting |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKS20 Pore Water Sampler System |
| Vacuum Controllers | VS-Pro, VacuPorter, VPS-2 |
| Sampling Principle | Suction-based ceramic cup extraction under controlled negative pressure |
| Ceramic Cup Material | Sintered aluminum oxide |
| Cup Dimensions | Ø2 cm × 6 cm |
| Dead Volume | Minimal |
| pH Range | 4–9 |
| Bubble Point | –100 kPa |
| Sampling Rate (Free Water, –50 kPa) | ~5 mL / 10 min |
| Sampling Rate (Sandy Loam, –50 kPa) | ~5 mL / h |
| Vacuum Range (VS-Pro) | 0 to –85 kPa |
| Vacuum Accuracy (VS-Pro) | ±0.05 kPa |
| Power Supply (VS-Pro) | 10.5–15 VDC |
| Current Draw (VS-Pro, Operating) | ~15–16 mA |
| Memory Capacity (VS-Pro) | 5,000 readings |
| Enclosure Rating (VS-Pro) | IP66 |
| Operating Temperature (VS-Pro) | –10 °C to 45 °C |
| VacuPorter Max Vacuum | –85 kPa @ 1 bar |
| VacuPorter Flow Rate | 10 L/min |
| VacuPorter Battery Life | 7 h |
| VPS-2 Max Vacuum | –85 kPa @ 1 bar |
| VPS-2 Displacement | 0.41 L/stroke |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. |
| Model | TEROS 10 |
| Measurement Principle | 70 MHz Frequency Domain Reflectometry (FDR) |
| Output | Analog Voltage (1,000–2,500 mV) |
| VWC Range | 0–64% (soil), 0–70% (non-soil media) |
| Resolution | 0.001 m³/m³ |
| Accuracy | ±0.03 m³/m³ (±3.0% VWC) in mineral soils with EC < 8 dS/m using generic calibration |
| Dielectric Constant Range | 1–80 |
| Accuracy of εₐ | ±1 εₐ (1–40), ±15% of reading (40–80) |
| Operating Temperature | −40 to +60 °C |
| Probe Length | 5.4 cm |
| Housing Dimensions | 5.1 × 2.4 × 7.5 cm (L×W×H) |
| Cable Length | Standard 5 m (custom up to 40 m) |
| Connector | 3.5 mm TRS jack or bare leads |
| Excitation Voltage | 3.0–15.0 VDC |
| Measurement Duration | 10–25 ms |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), EN 61326-1:2013, EN 55022/CISPR 22 |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | TEROS 11 |
| Measurement Principle | 70 MHz Capacitive Dielectric Sensing |
| Output Protocol | SDI-12 / DDI Serial |
| Compliance | ISO 9001:2015, EN 61326-1:2013, EN 55022/CISPR 22, CE Marked per 2014/30/EU & 2011/65/EU |
| Sensor Dimensions | 9.4 × 2.4 × 7.5 cm (L×W×H) |
| Probe Length | 5.5 cm |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Operating Temperature | −40 to +60 °C |
| VWC Range (mineral soil) | 0.00–0.70 m³/m³ |
| VWC Accuracy (generic mineral soil cal) | ±0.03 m³/m³ (EC < 8 dS/m) |
| Temp Accuracy | ±1.0 °C (−40 to 0 °C), ±0.5 °C (0 to 60 °C) |
| Temp Resolution | 0.1 °C |
| VWC Resolution | 0.001 m³/m³ |
| Dielectric Range | 1–80 (εₐ) |
| Frequency | 70 MHz |
| Power Supply | 4.0–15.0 VDC |
| Sleep Current | ~0.03 mA |
| Active Current (25 ms) | 3.0–16.0 mA |
| Interface | 3.5 mm TRS or bare-wire termination |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FE20K |
| Price | USD 580 (approx.) |
| pH Range | 0.00–14.00 |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0–100 °C |
| Calibration Points | Up to 3-point |
| Temperature Compensation | Automatic or Manual |
| Endpoint Detection | Automatic or Manual |
| Buffer Recognition | Yes |
| Electrode Status Indicator | Yes |
| Slope Display | Yes |
| Reference Electrode Input | Yes |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 2060 IC |
| Instrument Type | Online Analyzer |
| Application Scope | Universal |
| IP Rating | IP65 |
| Modular Configuration | Single- or Dual-Channel |
| Monitoring Capacity | Up to 20 Sampling Points |
| Integrated Sample Preparation | Inline Metrohm Inline Sample Preparation (ISP) System |
| Eluent Generation | Electrolytic Eluent Generator (EG) |
| Water Supply Compatibility | ELGA PURELAB® flex 5/6 Ultra-Pure Water System |
| Software | MagIC Net™ v4.x (21 CFR Part 11 Compliant) |
| Regulatory Compliance | GLP/GMP-Ready, Audit Trail Enabled |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2060NIR |
| Instrument Type | Online NIR Spectrometer |
| Application Scope | General-purpose (Academic & Research Laboratories) |
| Operating Principle | Grating-based, Non-scanning Array Detector |
| Wavelength Range | 1000–2250 nm |
| Scan Rate | 5000 spectra/s |
| Spectral Sampling Interval | 0.5 nm |
| Measurement Mode | Real-time In-line Analysis |
| Chemometrics Software | IMPACT / OMNIS |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Country of Origin | Imported (Switzerland) |
| Model | 2060 Raman |
| Laser Wavelength | 785 nm |
| Number of Simultaneous Sampling Channels | Up to 5 |
| Spectral Resolution | High-throughput optimized |
| Environmental Rating | NEMA 4X / IP66 |
| Calibration | Integrated reference channel with automated Raman shift correction |
| Analysis Time per Sample | ≤10 seconds |
| Communication Protocols | 4–20 mA, OPC UA, Modbus TCP, Profibus DP |
| Software Platform | Vision and IMPACT |
| Fluorescence Suppression | Advanced real-time algorithm |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 61574210 |
| Application | Universal Potentiometric Titration |
| Compatible Syringe Volume | 10 mL |
| Tubing Material | FEP/ETFE |
| Connection Thread | M6 (Metrohm Standard) |
| Chemical Resistance | Excellent (resistant to strong acids including perchloric acid and HCl, strong bases, and common organic solvents) |
| Optical Clarity | High-transparency for real-time bubble detection |
| Dimensional Precision | Engineered for exact fit with Metrohm 10 mL exchange units to minimize dead volume and mechanical stress |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 702 Economy |
| Price | Upon Request |
| pH Range | 0 to ±20.00 |
| Potential Range | 0 to ±2000 mV |
| Current Range | 0 to ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Burette Resolution | 1/10,000 of selected volume |
| Absolute Burette Error | ±0.02 mL (with 10 mL burette) |
| Relative Accuracy | ±0.2% (with 10 mL burette) |
| Input Impedance | >10¹³ Ω |
| Current Compensation | <3.1 × 10⁻¹³ A |
| Thermal EMF Compensation Drift | 15 µV/K |
| Electrode Inputs | 2 high-impedance measuring electrodes, 1 reference electrode, 1 polarizable electrode, 1 temperature sensor |
| Polarization Range | Current 0 to ±127 µA |
| Differential Amplifier | Optimized for low-conductivity non-aqueous titrations |
| Method Storage Capacity | 100 pre-programmed or user-defined methods |
| Dimensions (W × H × D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 719 SET Basic |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Type | Imported Instrument |
| Model | 785 Universal |
| Pricing | Upon Request |
| Measurement Range | pH 0 to ±20.00 |
| Potential | ±2000 mV |
| Current | ±200.0 µA |
| Temperature | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Resolution | 1/10,000 of burette volume |
| Absolute Accuracy | ±0.02 mL (with 10 mL burette) |
| Relative Accuracy | ±0.2% (with 10 mL burette) |
| Input Impedance | >10¹³ Ω |
| Polarization Current | ±127 µA |
| Polarization Potential | ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance indicator electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 794 Standard |
| Price | Upon Request |
| pH Range | 0 to ±20.00 |
| Potential Range | 0 to ±2000 mV |
| Current Range | 0 to ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Burette Volumes | 1, 5, 10, 20, or 50 mL |
| Burette Resolution | 1/10000 of selected volume |
| Absolute Accuracy (10 mL burette) | ±0.02 mL |
| Relative Accuracy (10 mL burette) | ±0.2% |
| Input Impedance | >10¹³ Ω |
| Polarization Current | 0 to ±127 µA |
| Polarization Potential | 0 to ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance measuring electrodes, 1 reference electrode, 1 polarization electrode, 1 temperature sensor |
| Method Storage Capacity | 100 methods |
| Dimensions (W×H×D) | 150 × 450 × 275 mm |
| Origin | Switzerland |
|---|---|
| Titration Volume Options | 1, 2, 5, 10, 20, or 50 mL |
| pH Range | 0 to ±20.00 |
| Potential Range | ±2000 mV |
| Current Range | ±200.0 µA |
| Temperature Range | −150.0 to +450.0 °C |
| Titration Resolution | 1/10,000 of burette volume |
| Absolute Accuracy (10 mL burette) | ±0.02 mL |
| Relative Accuracy (10 mL burette) | ±0.2% |
| Input Impedance | >10¹³ Ω |
| Polarization Current | ±127 µA |
| Polarization Potential | ±1270 mV (10 mV steps) |
| Electrode Inputs | 2 high-impedance measuring, 1 reference, 1 polarization, 1 temperature sensor |
| Method Storage Capacity | 100 methods |
| Dimensions (W×H×D) | 150 × 450 × 275 mm |