| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | GAS-3529A-16 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sampling Rate | 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Minimum Sample Volume | 1 mL (configurable to 2 mL or 3 mL) |
| Quantitative Loop Volume | 1 mL / 2 mL / 3 mL (user-selectable) |
| Positioning Accuracy | RSD < 1% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Sample Capacity | 16 positions (base unit) |
| Dimensions (L×W×H) | 40 × 50 × 37 cm (height increases by 15 cm per added module) |
| Cleaning | Automated syringe needle path flush + quantitative loop purge + gas bag rinse |
| Valve Actuation | PEEK body with PI (polyimide) rotor |
| Tubing Material | PTFE and PEEK only |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Compliance | Meets GB/T 33642–2017 (Chinese national standard for gas sampling systems in GC applications) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3539 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Positions | 88 |
| Min Sample Positions | 16 |
| Quantitative Loop Volumes | 1 mL, 2 mL, 3 mL (selectable) |
| Positioning Accuracy | RSD <0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Interface | PC-based upper-computer software |
| Needle & Loop Cleaning | Automated in-line cleaning of sampling lines, quantitative loops, gas bags, and sample pathways during GC coupling |
| Repeat Injection Capability | Unlimited cycles per sample |
| Operating Temperature Range | −20 °C to 50 °C |
| Storage Temperature Range | −40 °C to 70 °C |
| Humidity Range (Operating) | 10–90% RH |
| Humidity Range (Storage) | 5–90% RH |
| Syringe Capacity | 100 mL |
| Gas Bag Capacity | 500 mL or 1 L |
| Minimum Injection Volume | 50 µL (loop-dependent) |
| Maximum Injection Volume | 5 mL (loop-dependent) |
| Max Purge Time | 600 s |
| Max Draw Time | 99 s |
| Max Equilibration Time | 99 s |
| Max Interval Between Injections | 999 min |
| Quantitative Loop Heating Range | Ambient to 150 °C |
| Sample Pathway Heating Range | Ambient to 150 °C |
| Calibration Standard Points | Up to 8 programmable concentration levels |
| Cleaning Cycles per Step | 1–15 |
| Sampling Pump Flow Rate | Up to 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Dimensions (L×W×H) | 900 × 600 × 900 mm |
| Tubing Material | Silanized stainless steel |
| Valve Body | PEEK |
| Valve Core | PI (Polyimide) |
| Sample Port Flexibility | Dual-mode — gas bag or syringe injection per port |
| High-Concentration Detection Logic | Auto-halt + GC oven ramp initiation upon detection of saturation-level analyte signals |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LAS-3622 |
| Instrument Type | HPLC Autosampler |
| Max Sample Capacity | 200 positions |
| Minimum Injection Volume | 0.1 µL–2 mL |
| Loop Volumes | 50 µL, 100 µL, 250 µL, 1000 µL |
| Positioning Accuracy | <1% RSD at 1 µL, <0.5% RSD at 5 µL, <0.3% RSD at 10 µL |
| Sampling Mechanism | Loop-based injection |
| Needle Wash Modes | Automated line purge, bubble removal, pre-injection wash, post-injection wash |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | ANPRO |
|---|---|
| Model | APN-II |
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Wavelength Range | 185–950 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ≤±0.05 nm |
| Detector | CCD Array |
| Optical System | Dual-Wavelength Scanning with Hybrid Diffraction Grating |
| Automation Level | Fully Automatic Wavelength Selection & Sample Handling |
| Sample Throughput | Up to 12 Cuvettes (11 Simultaneous Samples + Reference) |
| Display | 10.1-inch Capacitive Touch LCD with VGA/HDMI Output |
| Computing Platform | Embedded Industrial PC (Quad-Core CPU, 4 GB RAM, Windows OS) |
| Data Storage | 500 GB SSD |
| Connectivity | Dual USB 2.0, RS232, Ethernet, Wi-Fi, VGA, Audio Out |
| Compliance | Designed for GLP-compliant food safety laboratories |
| Brand | Anritsu |
|---|---|
| Origin | Japan |
| Model | MS9740B |
| Wavelength Range | 600–1750 nm |
| Wavelength Accuracy | ±20 pm (1520–1620 nm, RBW 0.03–0.2 nm) / ±100 pm (1520–1620 nm, RBW 0.5/1.0 nm) |
| Wavelength Resolution (RBW) | 0.03 / 0.05 / 0.07 / 0.1 / 0.2 / 0.5 / 1.0 nm (3 dB bandwidth) |
| Dynamic Range | ≥60 dB at 0.4 nm offset from peak |
| Minimum RBW | 30 pm |
| Scan Speed | ≤0.2 s for 5 nm span (RBW 0.1 nm, VBW 10 kHz) |
| Max Input Power | +23 dBm (with optical attenuator enabled) |
| Fiber Compatibility | SMF-28 (9/125 µm, ITU-T G.652), 50/125 µm GI fiber |
| Connector Options | Interchangeable FC, SC, ST, DIN, LC |
| Storage Capacity | Up to 1,000 files or 10,000 spectra |
| Interfaces | Ethernet (standard), GPIB (optional) |
| Dimensions | 426 × 177 × 350 mm (W×H×D, excluding protrusions) |
| Weight | ≤15.0 kg (excluding options) |
| Power Consumption | ≤75 VA |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | ALEXYS |
| Instrument Type | Conventional High-Performance Liquid Chromatograph with Electrochemical Detection |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 70 MPa |
| Autosampler Capacity | 192 positions |
| Injection Volume Range | 1–20 µL |
| Column Oven Temperature Range | Ambient +7 °C to 60 °C |
| Detector Output Range | −2500 mV to +2500 mV |
| Data Acquisition Frequency | 1–100 Hz |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE Elite |
| Detector Type | Electrochemical Detector (ECD) |
| Compatible Systems | HPLC, UHPLC, EC-MS Coupling |
| Operating Modes | DC, Pulsed, Scanning |
| Signal Processing | Advanced Digital Filter (ADF) |
| Flow Cell Volume Range | 0–300 nL (continuously adjustable) |
| Cell Design | Central Jet-Wall Electrode Configuration |
| Temperature Control | Integrated Faraday-Shielded Thermostatic Chamber |
| Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECADE II |
| Pricing | Upon Request |
| Detector Type | Electrochemical Detector (ED) |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC, Pulse, and Scan |
| Digital Filter Range | 0.5–0.001 Hz (1–2–5 decade steps) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | H 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temp. Stability | ±0.1 °C |
| Flow Cell Types | Central Jet Wall-Flow Cell & Conventional Thin-Layer Cell |
| Electrode Configurations | SCC, DCC, TCC, QCC |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II SDC |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC Amperometry with Advanced Digital Filtering (ADF) |
| Filter Frequency Range | 0.5–0.001 Hz (decade steps: 1, 2, 5) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | Height 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temperature Stability | ±0.1 °C |
| Flow Cell Types | Central-jet wall-type electrode (compatible with standard & capillary HPLC columns) and conventional thin-layer electrode |
| Electrode Configurability | Interchangeable working and reference electrodes (e.g., glassy carbon, gold, platinum, Ag/AgCl) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200R |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | Standard 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| Refractive Index (RI) Detection Range | 1.00–1.75 RIU |
| Data Acquisition Rate | 100 Hz |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Aquatrac-V |
| Measurement Principle | Calcium Hydride Reaction (DIN EN ISO 15512:2019) |
| Resolution | 0.0001% H₂O |
| Application | Residual Moisture Analysis in Thermoplastics & MFR Sample Preparation |
| Compliance | Fully compliant with DIN EN ISO 15512:2019 for selective water determination in plastics |
| Software | Aquatrac Control Software with LIMS/ERP integration capability |
| Data Integrity | Audit trail, user access levels, electronic signatures (21 CFR Part 11 ready) |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | MT-CA / Aquatrac-V |
| Measurement Principle | Gravimetric (MT-CA), Calcium Hydride Reaction + Vacuum Pressure Monitoring (Aquatrac-V) |
| Moisture Range | 0.1% to 99.9% (MT-CA) |
| Compliance | DIN EN ISO 15512:2019, ICC 113, ISO 712, EC Tobacco Specifications |
| Software | MetaBridge v3.x (FDA 21 CFR Part 11 compliant audit trail, LIMS/ERP integration, GLP/GMP workflow support) |
| Sample Throughput | Up to 10 samples per run (MT-CA) |
| Standards Support | Preloaded methods for flour, tobacco, polymers, pasta, coffee, building materials |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | Cora 100 |
| Spectral Range | 400–2300 cm⁻¹ |
| Spectral Resolution | <10 cm⁻¹ |
| Spatial Resolution | <1 mm |
| Laser Wavelength | 785 nm |
| Laser Power at Sample | >215 mW |
| Detector | Linear CCD Array |
| Display | Transflective TFT with LED Backlight |
| Operating Temperature | −20 °C to +40 °C |
| IP Rating | IP67 |
| Dimensions | 15.8 cm × 10.1 cm × 2.9 cm |
| Weight | 650 g |
| Battery Life | Up to 60 scans per charge |
| Data Format | Text (.txt) |
| Connectivity | USB 2.0 |
| OS | Embedded Linux |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 5001 |
| Detector Type | CMOS |
| Laser Class | Class 1 |
| Safety Interlock | Integrated shutter-based activation (laser only active when sample chamber is fully closed) |
| Optical Architecture | Monolithic aluminum optical bench, no moving parts |
| Focus Mechanism | Motorized auto-focus with real-time signal optimization |
| Excitation Options | Dual-wavelength “Dual-Core Raman” configuration available (e.g., 785 nm and 1064 nm) |
| Sample Compatibility | Solids (tablets, films, crystals), liquids (in vials of circular/square/rectangular cross-section), powders, pastes |
| Accessories | Magnetic sample holders, universal vial adapters, solid-sample stage with quick-lock positioning |
| Compliance | IEC 60825-1:2014 (Class 1 laser product), CE marked, RoHS compliant |
| Software | Cora Suite v3.x with spectral library matching (≥10,000 reference spectra), GLP-compliant audit trail, FDA 21 CFR Part 11 optional module |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Portable/Desktop Raman Spectrometer |
| Model | Cora 5001 |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 6–9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.5 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Cora 5001 Direct |
| Instrument Type | In-line Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ (wavelength-dependent) |
| Laser Classes | Class 1 (Direct model) |
| Excitation Wavelengths | 532 nm, 785 nm, 1064 nm (single- or dual-wavelength configurations) |
| Spectral Resolution (per ASTM E2529) | 6–17 cm⁻¹ (wavelength-dependent) |
| Detector | 2048-pixel CCD (532/785 nm), 256-pixel InGaAs (1064 nm) |
| Auto-focus | Yes |
| Software | Anton Paar Spectroscopy Suite (with audit trail, electronic signatures, SQL database, GLP/GMP support) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Cora 5001 Fiber |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 100–3500 cm⁻¹ |
| Spectral Resolution | 6–9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | < 0.5 cm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | SAXSpace |
| Instrument Type | Small-Angle and Wide-Angle X-ray Scattering (SAXS/WAXS) System |
| q-Range | 0.03–49 nm⁻¹ |
| Real-Space Resolution Range | 0.13–200 nm |
| Maximum 2θ | 74° |
| X-ray Source | Sealed-tube (line or point focus) |
| Beam Size | 20 × 0.3 mm² (line), 0.3 × 0.3 mm² (point) |
| Operating Voltage | 40 kV |
| Operating Current | 50 mA |
| Minimum Sample Volume | 7 µL (liquid), few mg (solid) |
| Temperature Control Range | −150 to 300 °C (±0.1 °C stability) |
| Measurement Time | 1–60 min |
| Automation | Motorized optical alignment, in situ heating/cooling, liquid handling compatibility |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | SAXSpoint 500 |
| Instrument Type | Small-Angle X-ray Scattering (SAXS) System |
| q-Range | 0.02 nm⁻¹ to 43 nm⁻¹ |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XRDynamic Autosampler |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Instrument Configuration | Floor-standing |
| Sample Capacity | Up to 105 positions |
| Compatible With | XRDynamic 500 XRD system |
| Integration | Native integration with XRDdrive software |
| Sample Holder Compatibility | Standard ISO/ASTM-compliant sample holders (powder, solid, fiber, foil, thin film, air-sensitive samples) |
| Measurement Modes | Reflective and transmission geometries |
| Automation Level | Fully automated sample loading, positioning, alignment, and beam path switching |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software logging |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | Anyeep 7600 |
| Price Range | USD 42,000–70,000 (FOB Jiangsu) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC Interface |
| Mass Range | 1.5–1050 u |
| Resolution (10% Valley) | 2000 |
| Sensitivity | 1 pg Octafluoronaphthalene (OFN), m/z 272, S/N ≥ 600:1 (RMS) |
| Scan Speed | 20,000 u/s |
| Oven Ramp Rate | Up to 120 °C/min |
| Pressure Control Accuracy | ±0.001 psi |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | Anyeep Precision Instruments Co., Ltd. |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Conventional Gas Chromatography Interface |
| Mass Range | 0–1250 amu |
| Vacuum Architecture | Dual-Chamber, Dual-Turbomolecular Pump System (Independent Ion Source & Quadrupole Exhaust) |
| Startup-to-Analysis Time | ≤30 min |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph Coupling |
| Mass Analyzer | Dual-Hyperbolic Rod Quadrupole |
| Resolution (FWHM at m/z 69) | 0.25 Da |
| Isotopic Ratio Accuracy | Enhanced for PFBA, PFTBA, and Low-Mass Ions (He⁺, H₂O⁺, N₂⁺, O₂⁺) |
| RF Power Supply | Upgraded Wide-Mass-Range Stable Frequency Generator |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | Anyeep Cassitrap 120K |
| Chromatography Type | Capillary GC-coupled |
| Mass Range | 1.5–1250 Da (Quadrupole Mode) |
| Resolution | >120,000 FWHM at m/z 131 (1.5 Hz acquisition rate) |
| Sensitivity | ≥1000:1 S/N for 100 fg octafluoronaphthalene (OFN), m/z 272 (quadrupole mode) |
| Scan Speed | 20,000 Da/s (quadrupole mode) |
| Mass Accuracy | ±0.1 Da (quadrupole mode) |
| Oven Ramp Rate | ≥120 °C/min (standard column oven) |
| Detector | Electron Multiplier (quadrupole mode only) |
| Pressure Control Precision | ±0.001 psi |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | LC Cassitrap 120K |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Mate11 |
| Instrument Type | Portable GC-MS |
| Mass Range | 1.5–550 amu |
| Dynamic Range | 7 orders of magnitude |
| Mass Resolution | Unit mass resolution |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | 1 pg octafluoronaphthalene (OFN), S/N = 150:1 (RMS) |
| Weight | < 20 kg |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RGA 6500 |
| Pricing | Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | SQ910 LC-MS |
| Pricing | Available Upon Request |
| Brand | Anyeep |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| Model | Anyeep TQ8100 |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Integrated acquisition and quantitation platform with audit trail capability |