Chemical Analysis Instruments
Filter
Showing 6841–6870 of 10731 results
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | L820 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical HPLC |
| Price Range | USD 56,000 – 84,000 (FOB Beijing) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11, Chinese Pharmacopoeia 2020 Edition, Chinese Veterinary Pharmacopoeia 2020 Edition |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Single Quadrupole GC-MS |
| GC Platform | Agilent 7890A |
| Mass Range | 1.5–1050 amu |
| Mass Accuracy | ±0.1 amu |
| Resolution | Unit Mass Resolution (R = 1000, W₁/₂ < 1 amu) |
| S/N (EI) | ≥150:1 RMS (5 pg OFN full scan, m/z 272 |
| Mass Stability | ±0.1 amu over 48 h |
| Max Scan Speed | 10,000 amu/s |
| Vacuum System | Dual-stage — GLD-N201 forepump (4 L/s) + Pfeiffer TMH071P (60 L/s) or TMH262P (210 L/s) turbomolecular pump |
| Ion Source | Heated EI source, 350 °C max, 10–100 eV electron energy, 200 µA emission current |
| Detector | High-voltage conversion dynode electron multiplier with composite I/V amplifier |
| Control Interface | 100 Mbps Ethernet, 32-bit embedded real-time OS |
| Software | Persee ChemStation v3.x (NIST08 library integrated)] |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Persee General Instrument Co., Ltd. |
| Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pumps |
| Waste Disposal | Gravity-driven |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% (for As, Sb, Bi, Hg) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL (As, Sb, Bi) |
| Photomultiplier Tube | Hamamatsu R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PF5 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Dual Sequential Injection Pump |
| Waste Liquid Discharge | Gravity-driven (Static) |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% for representative elements (As, Sb, Bi, Hg) |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL for As, Sb, Bi |
| Photomultiplier Tube (PMT) | R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction Mode | Dual Sequential Injection Pump |
| Waste Liquid Disposal | Gravity-driven (Static) |
| Hydride Generation Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn |
| Relative Standard Deviation (RSD) | <1% for As, Sb, Bi, Hg |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | ≤0.01 ng/mL for As, Sb, Bi |
| Photomultiplier Tube (PMT) | Hamamatsu R7154, spectral response range 160–320 nm |
| Atomizer Temperature Control Range | Ambient to 400 °C] |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SA7/5 |
| Instrument Type | Multi-channel Atomic Fluorescence Spectrometer |
| Sample Introduction | Pneumatic Flow Injection System (replaces peristaltic pump) |
| Waste Disposal | Gravity-driven dual-port drainage |
| Sample Introduction Mode | Vapor Generation / Hydride Generation |
| Gas Flow Control | Mass Flow Controller (MFC) |
| Detectable Elements | As, Hg, Se, Sb |
| RSD | ≤1.0% (at 0.01 ng/mL for As, Sb, Bi |
| Linear Dynamic Range | >3 orders of magnitude |
| Detection Limits | As/Sb/Bi ≤ 0.01 ng/mL |
| PMT Spectral Range | Hamamatsu R7154, 160–320 nm |
| Atomizer Temperature Control | Ambient to 100 °C, adjustable in 0.1 °C increments |
| UV Digestion Cell | Quartz plate-type flow-through reactor with high UV photon utilization |
| Dual-Channel Waste Separation | Organic and inorganic waste streams isolated via dedicated tubing paths |
| Certified Performance Data Source | Public Service Platform for Enterprise Standard Information (China) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Solid Sample Testing Solution |
| Price Range | USD 14,000 – 21,000 (FOB) |
| Optical Architecture | Dual-Wavelength Configuration |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning Mode | Automatic |
| Stray Light | < 0.0004% (4 × 10⁻⁴ %) |
| Compatible Accessories | 150 mm Integrating Sphere (Standard), 60 mm Integrating Sphere (Standard), Eyewear-Specific Measurement Fixture |
| Sample Types | Opaque/Translucent Solids, Powders, Turbid Liquids |
| Measurement Modes | Diffuse Reflectance, Specular Reflectance, Total Transmittance, Diffuse Transmittance |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | T400 / T500 |
| Price Range | USD 1,400 – 4,200 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1100 nm (T400) / 190–1100 nm (T500) |
| Wavelength Accuracy | ±0.2 nm (T400) / ±0.1 nm (T500) |
| Wavelength Repeatability | ≤0.4 nm (T400) / ≤0.2 nm (T500) |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05%T at 360 nm (T400) / ≤0.05%T at 220 nm (T500) |
| Wavelength Scanning Speed | 2500 nm/min |
| Wavelength Setting Speed | 7000 nm/min |
| Dimensions (W×D×H) | 470 × 400 × 210 mm |
| Weight | 11 kg |
| Display | 7-inch Color Touchscreen |
| Data Export | USB Flash Drive Support |
| Sample Compartment | Open-Design with Integrated Cuvette Storage Rack |
| Software Interface | PC-Connectable Workstation with GLP Compliance Features |
| Firmware Upgradability | Over-the-Air (OTA) for Application Module Expansion (e.g., Protein Quantitation, Pesticide Residue Analysis, Water Quality Testing) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Domestic |
| Model | T6 Series |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Positioning |
| Spectral Bandwidth | 2.0 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | 0.05% T at 220 nm |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | T6 |
| Price | USD 1,150 (FOB Beijing) |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scan |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.05 % |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | T700/T600 |
| Optical Design | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 5 nm / 2 nm / 1 nm / 0.5 nm / 0.2 nm (selectable) |
| Stray Light | ≤0.01% T at 220 nm |
| Absorbance Range | –4 to +4 Abs |
| Scan Speed | Up to 30,000 nm/min |
| Interface | Ethernet port |
| Display | 9.7-inch capacitive touchscreen |
| Compliance | Meets JJG 178–2015 (Chinese National Verification Regulation for UV-Vis Spectrophotometers, Class I accuracy) |
| [Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Architecture | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 185 nm – 900 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm) |
| Wavelength Repeatability | ≤0.05 nm (at D₂ line, 656.1 nm) |
| Spectral Bandwidth | Continuously Adjustable from 0.1 nm to 5.0 nm |
| Stray Light | ≤0.0001% T (NaI, 220 nm) |
| Photometric Range | –6 Abs to +6 Abs |
| Baseline Flatness | ±0.0008 Abs |
| Absorbance Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3% T (>1.0 Abs) |
| Absorbance Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.1% T (>1.0 Abs) |
| Drift | ≤0.1% T/h |
| Optical System | Hybrid Czerny-Turner Dual-Monochromator with High-Reflectivity Coated Optics |
| Light Sources | Integrated Deuterium Lamp, Tungsten-Halogen Lamp, and Mercury Calibration Lamp (Auto-Switching)] |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Wavelength Accuracy | ±0.25 nm |
| Spectral Bandwidth | ≤0.15 nm |
| Detection Limit (Flame, Cu) | 0.006 µg/mL |
| Detection Limit (GFAAS, Cd) | 1.0 pg |
| Characteristic Concentration (Cu) | <0.04 µg/mL per 1% absorption |
| Baseline Stability (Static) | ±0.004 A/30 min |
| RSD (Flame Cu) | <1% |
| RSD (GFAAS Cu) | <3.0% |
| RSD (GFAAS Cd) | <4.0% |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Persee General Instrument Co., Ltd. |
| Model | TAS-990 |
| Instrument Type | Dual-mode (Flame + Electrothermal Graphite Furnace) |
| Monochromator | Concave Grating |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + Self-reversal Method |
| Wavelength Accuracy | ±0.25 nm |
| Baseline Stability (Static) | ±0.004 A / 30 min |
| RSD (Repeatability) | ≤1.0% (Flame, Cu), ≤3.0% (GFAAS, Cu) |
| Characteristic Concentration (Cu) | <0.04 µg/mL per 1% absorption |
| Detection Limit (Flame, Cu) | <0.006 µg/mL |
| Detection Limit (GFAAS, Cd) | <1.0 pg |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Architecture | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Automatic Wavelength Drive |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 5.0 nm (TU-1810S models, variable slit) |
| Wavelength Accuracy | ±0.3 nm (with automatic on-boot wavelength calibration) |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.02% T at 220 nm (using NaI solution), ≤0.05% T at 360 nm (using NaNO₂ solution) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Model | TU-1810 |
| Optical System | Double-beam ratio-monitoring |
| Detector Type | Photodiode Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Spectral Bandwidth | 2 nm (fixed), optional 0.5/1.0/2.0/5.0 nm (variable slit) |
| Stray Light | ≤0.2% (at 220 nm, NaI |
| Absorbance Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.3% T |
| Absorbance Repeatability | ≤0.001 Abs (0–0.5 Abs), ≤0.002 Abs (0.5–1.0 Abs), ≤0.15% T |
| Baseline Flatness | ±0.001 Abs |
| Drift | ≤0.2%/h (at 500 nm, after 2 h warm-up) |
| Dimensions | 530 × 430 × 240 mm |
| Weight | 25 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TU-1901 |
| Price | USD 27,500 (FOB Beijing) |
| Optical Design | Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–900 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 5.0 nm (selectable: 0.1/0.2/0.5/1.0/2.0/5.0 nm) |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Stray Light | ≤0.015% T (at 220 nm, NaI |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UV-Vis Automated Liquid Sampling Solution |
| Price Range | USD 14,000 – 21,000 |
| Optical Design | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm (typical) |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.05% T at 220 nm and 360 nm |
| Automation Level | Fully Automated Wavelength Scanning & Sample Handling |
| Sample Capacity | Three Independent Sample Carriers Supporting Configurable Racks (50 mL × 10 wells, 25 mL × 18 wells, or 20 mL × 18 wells) |
| Positioning System | Programmable 3-Axis Robotic Arm with Sub-millimeter Repeatability |
| Cleaning Mechanism | Peristaltic Pump–Driven Dynamic Immersion Rinse with Solvent Exchange Protocol |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | XD-2 / XD-3 |
| Instrument Type | Powder X-ray Diffractometer |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Detector | Imported NaI Scintillation Counter |
| Goniometer Configuration | Vertical θ–θ geometry with hollow-axis design |
| X-ray Source Control | Fully digital, microprocessor-regulated high-voltage and tube current |
| Software | PDP Diffraction Data Processing Suite (Windows-based, multi-format export support) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | XD-6 Series |
| Price Range | USD 42,000 – 70,000 |
| Brand | Perser-Tech |
|---|---|
| Origin | Fujian, China |
| Model | PERS-F700 |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 175–3500 cm⁻¹ |
| Spectral Resolution | ≤7 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 175 cm⁻¹ |
| Spectral Reproducibility | ±1 cm⁻¹ |
| Operating Temperature | 5–45 °C |
| Relative Humidity | <90% RH |
| Excitation Wavelength | 785 nm (standard, fixed-frequency diode laser) |
| Integration Time & Laser Power | Continuously Adjustable |
| Sample Interface | Non-contact, focus-adjustable collimated beam |
| Brand | Perten |
|---|---|
| Origin | Imported (Sweden) |
| Model | AM 5200 |
| Heating Method | Radiofrequency (150 MHz) |
| Measurement Principle | RF Dielectric Constant |
| Sample Volume | 700 mL |
| Analysis Time | ~10 s |
| Display | 5.7-inch color resistive touchscreen |
| Communication | USB port |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115/230 V, 50/60 Hz |
| Dimensions (W×D×H) | 415 × 424 × 353 mm |
| Net Weight | 18.3 kg |
| Measured Parameters | Moisture content, bulk density, temperature |
| Sample Types | Cereals, oilseeds, pulses (soybeans, lentils), dry beans, seeds, and other agricultural commodities |
| Brand | Perten |
|---|---|
| Origin | USA |
| Model | DA 7350 |
| Instrument Type | Online |
| Wavelength Range | 950–1650 nm |
| Scan Speed | >30 sub-spectra per second |
| Data Sampling Interval | User-Configurable |
| Measurement Modes | Near-Infrared Reflectance & Digital Color Imaging |
| Chemometrics Software | PerCAL |
| Compliance | Designed for GLP/GMP environments |
| Communication Protocols | OPC UA, PROFINET, Modbus TCP, Fieldbus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7250 |
| Instrument Type | Laboratory |
| Principle | Grating-based non-scanning diode array spectrometry |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 100 spectra/sec |
| Data Sampling Interval | 0.008 s |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | Unscrambler |
| Detector | Thermoelectrically Cooled InGaAs Diode Array |
| Optical Resolution | Adjustable from 0.1 nm to 10 nm |
| Spectral Bandwidth | ~7 nm |
| Wavelength Accuracy | <0.05 nm |
| Wavelength Repeatability | <0.02 nm (per measurement), <0.2 nm/year |
| Absorbance Range | 0–2.5 AU |
| Noise Level | <20 µA (10 s continuous acquisition) |
| Light Source Lifetime | >10,000 h |
| Operating Temperature | 0–40 °C |
| IP Rating | IP65 |
| Sample Weight Capacity | 0.5–300 g (solids), 2–100 mL (liquids) |
| Standard Sample Area | 154 cm² (large cup), 44 cm² (small cup) |
| Analysis Time | ≤6 s per sample |
| Measurement Geometry | Non-contact rotating scan |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7430M |
| Instrument Type | Online |
| Principle | Grating Scanning NIR Spectrometer |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/second |
| Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Ingress Protection Rating | IP67 |
| Optical Spot Diameter | >10 cm |
| Light Source | Long-Life Xenon Lamp |
| Mounting Compatibility | Chutes, Screw Conveyors, Belt Conveyors, Mixers, Scrapers |
| Communication Protocols | OPC UA, Ethernet, Modbus TCP/IP, 4–20 mA Analog Output, Profibus |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | DA7440 |
| Instrument Type | Online |
| Principle | Grating Scanning |
| Wavelength Range | 950–1650 nm |
| Scan Speed | 30 subspectra/sec |
| Data Sampling Interval | User-Configurable |
| Measurement Mode | Diffuse Reflectance / Transflectance |
| Chemometrics Software | Unscrambler X, Percal |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FT 9700 |
| Instrument Type | Laboratory |
| Application Domain | General-purpose (Academic & Research) |
| Operating Principle | Fourier Transform (FT) |
| Wavelength Range | 700–2500 nm (14,300–4000 cm⁻¹) |
| Scan Speed | <1 minute per spectrum |
| Data Sampling Interval | Adjustable |
| Sample Measurement Modes | Diffuse Reflectance and Transflectance |
| Chemometrics Software | PerCal |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 8800 |
| Instrument Type | Portable |
| Application Field | Cereals & Oilseeds |
| Measurement Principle | Grating-based diode array (non-scanning) |
| Wavelength Range | 850–1050 nm |
| Scan Time | 20 seconds |
| Data Sampling Interval | 5 nm |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| GPS Integration | Yes |
| Power Supply | 12 V DC or internal rechargeable battery (2 h runtime) |
| Compliance | AACC Method 39-25 |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM9520 |
| Instrument Type | Benchtop Laboratory NIR Spectrometer |
| Application Domain | Cereal Grains & Milled Flour |
| Optical Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/minute |
| Data Acquisition Interval | 6 seconds per measurement |
| Sample Mode | Transmission |
| Chemometrics Software | Unscrambler® |
| Calibration Framework | NIST-traceable wavelength calibration |
| Compliance | ASTM D6341 (NIR for cereal analysis), ISO 12099:2017 (Animal feeding stuffs — General guidelines for the determination of chemical constituents by NIR spectroscopy), GLP-compliant data audit trail support via NetPlus™ |
| Brand | Perten |
|---|---|
| Origin | Sweden |
| Model | IM 9500plus |
| Instrument Type | Laboratory NIR Spectrometer |
| Application Domain | Cereal & Oilseed Analysis |
| Principle | Grating Scanning Transmission NIR |
| Wavelength Range | 570–1100 nm |
| Scan Speed | 10 scans/min |
| Data Acquisition Interval | 6 s/scan |
| Measurement Mode | Transmission |
| Chemometrics Software | Unscrambler X |
