| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame AAS |
| Model | PinAAcle 500 |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam |
| Detector | Solid-State CCD Array |
| Background Correction | Deuterium Lamp |
| Flame System | FAST Flame Automated Burner Head Positioning and Gas Control |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer | PerkinElmer |
| Country of Origin | Imported |
| Model | PinAAcle 900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | D₂ Lamp + Longitudinal Zeeman |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | PinAAcle 900Z |
| Instrument Type | Graphite Furnace AAS |
| Monochromator | Echelle Grating |
| Optical System | Dual-Beam (not Single-Beam — corrected per official specs) |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Longitudinal Zeeman Effect |
| Resolution | 0.3 nm |
| Sensitivity (Cd 228.8 nm) | 0.3 pg |
| RSD (Repeatability) | ≤0.3% |
| Detection Limit (Cd) | 0.006 pg |
| Baseline Stability | ±0.005 absorbance units/30 min |
| Height | 64.0 cm |
| Width | 95.0 cm |
| Weight | 127.0 kg |
| 21 CFR Part 11 Compliance | Yes |
| Warranty | 1 Year |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PinAAcle D900 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp Correction |
| Safety Interlocks | 7 Integrated Sensors |
| Automation | Dual-Mode Autosampler Compatible with Both Flame and GF Modes |
| Software Interface | Touchscreen-Controlled Method Wizard with Real-Time Camera Integration |
| Reporting | Customizable PDF Reports Including Calibration Curves and Sample Data |
| Brand | PerkinElmer |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | PinAAcle™ 950D |
| Pricing | Available upon request |
| Brand | PerkinElmer |
|---|---|
| Origin | Canada |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QSight 400 |
| Instrument Type | Triple Quadrupole (TQ) LC-MS/MS |
| Application Scope | General-Purpose |
| Mass Range | Available upon consultation |
| Sensitivity | Available upon consultation |
| Resolution | Available upon consultation |
| Accurate Mass Capability | Not applicable (unit-mass resolution TQ system) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QSight 500 |
| Instrument Type | Triple Quadrupole (TQ) LC/MS/MS |
| Application Scope | General-purpose quantitative and confirmatory analysis in regulated and research laboratories |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | QSight |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Application Domain | General-Purpose Quantitative Analysis |
| Ionization Sources | Dual ESI/APCI Configurable |
| Polarity Switching Speed | Microsecond-Level |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) Coupled with Triple Quadrupole Mass Filtering and Collision-Induced Dissociation (CID) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SNFR |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spectrum 3 |
| Instrument Type | Laboratory FT-IR Spectrometer |
| Instrument Category | Fourier Transform Type |
| Wavenumber Range | Not Specified |
| Resolution | Not Specified |
| Scan Speed | Up to 100 scans/sec |
| Signal-to-Noise Ratio | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | L160000A |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Wavenumber Range | 350–7500 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Wavenumber Accuracy | ±0.1 cm⁻¹ |
| Wavenumber Precision | ±0.01 cm⁻¹ |
| Signal-to-Noise Ratio | 9,300:1 (5 scans, peak-to-peak), 32,000:1 (60 sec scan, peak-to-peak) |
| Detector | High-performance DTGS or optional MCT |
| Interferometer | DynaScan™ permanent alignment, no moving mirrors |
| Beamsplitter | KBr-coated |
| Optical Enclosure | Sealed, desiccated cavity with OpticsGuard™ moisture protection |
| Dimensions | 450 × 300 × 210 mm |
| Weight | 13 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spectrum Two |
| Instrument Type | Benchtop Laboratory FTIR Spectrometer |
| Instrument Category | Fourier Transform Infrared (FTIR) Spectrometer |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Spectrum Two N |
| Instrument Type | Laboratory Benchtop |
| Operating Principle | Fourier Transform (FT-NIR) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling (reflectance, transmission, remote probe) |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | Perten |
|---|---|
| Origin | United Kingdom |
| Model | Spectrum Two N |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform (Interferometric) |
| Wavelength Range | 680–4800 nm |
| Data Sampling Interval | 1/4 resolution or user-defined |
| Sample Introduction | Direct sampling |
| Software | Spectrum 10™ Suite (including Spectrum 10 ES, Spectrum Touch™, Spectrum Adulterant Screen, Spectrum Quant™ Advanced Algorithms Pack, Spectrum AssureID) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Spotlight 400/400N |
| Instrument Type | Laboratory FT-IR Imaging System |
| Detector Architecture | Patented Linear Array MCT Detector |
| Spectral Range | Up to 720 cm⁻¹ (Mid-IR) and Extended NIR Capability |
| Spatial Resolution | 1.56 µm (ATR mode), 6.25 µm / 25 µm / 50 µm (Transmission/Reflection modes) |
| Imaging Speed | Up to 170 spectra/sec |
| Scan Modes | Single-region, Multi-region, Unattended Overnight Acquisition |
| Sample Stage | Motorized, High-Precision, Repeatability ±0.001% |
| Optional Accessories | Imaging ATR, Large-Area Sample Stage |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Torion T-9 |
| Instrument Type | Portable GC-MS |
| Application Field | Environmental Monitoring |
| Weight | 14.5 kg |
| GC Technology | Low Thermal Mass (LTM) Capillary Column |
| MS Technology | Miniature Toroidal Ion Trap |
| Mass Range | 45–500 amu |
| Resolution | Unit resolution or better |
| Operating Temperature | 175 °C (ion trap) |
| Power Source | Rechargeable Li-ion battery (2.5 h runtime) |
| Carrier Gas | Integrated high-pressure helium cylinder |
| Sample Throughput | Up to 12 samples/hour |
| Temperature Ramp Rate | Up to 2.5 °C/s |
| Column Heating/Cooling | Rapid thermal cycling enabled by resistive LTM heating |
| Vacuum Requirement | ~10⁻³ Torr |
| Display | Color touchscreen interface |
| Software | CHROMION with NIST library integration, deconvolution, spectral averaging, and quantitative methods (internal/external standard) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 100 |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cryo-Focusing Trap Temperature Range | Down to −30 °C |
| Analyte Recovery Rate | >80% |
| Sample Capacity | 20 Sample Tubes |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | TurboMatrix 40 |
| Sample Capacity | 40 positions |
| Vial Size | 10 mL |
| Injection Valve Quantitative Loop Volume | 1 mL |
| Headspace Vial Heating Range | 35–210 °C (1 °C increments) |
| Injection Valve Temperature Control Range | Ambient to 210 °C |
| Sampling Technique | Pressure-Balanced Static/Dynamic Headspace with Optional Trap Enrichment |
| Automation Level | Fully Automated |
| Compatibility | Universal GC interface (all major GC brands) |
| Regulatory Compliance Support | 21 CFR Part 11-ready software architecture (when paired with TurboMass or Chromera CDS) |
| Data Integrity Features | Audit trail, user access levels, electronic signatures (software-dependent) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Product Type | Automated Thermal Desorber (Two-Stage) |
| Sample Capacity | 50-tube carousel |
| Cold Trap Temperature Range | −30 °C (electronic cooling, no liquid cryogen required) |
| Desorption Temperature Range | Ambient to 400 °C |
| Flow Control | Electronic Mass Flow Control (MFC) |
| Compliance | Compatible with all major GC systems (Agilent, Thermo Fisher, Shimadzu, etc.) |
| Software Interface | Graphical touchscreen with multilingual support (including English, Chinese, Spanish, German) |
| Data Integrity Features | Audit trail-ready configuration for GLP/GMP environments |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 650 ATD |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | Down to −30 °C |
| Desorption Recovery Rate | >80% |
| Sample Capacity | 20 tubes |
| Flow Control | Electronic Mass Flow Control (MFC) |
| Cryogen-Free Cooling | Yes |
| GC Compatibility | Universal (all major GC brands) |
| Interface | Standard GC inlet connection (e.g., split/splitless, PTV) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | PE 650 ATD |
| Instrument Type | Two-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 350 °C |
| Cold Trap Temperature Range | Down to −30 °C (electronic cooling, no liquid cryogen) |
| Desorption Recovery Rate | >80% |
| Sample Capacity | 20 sample tubes |
| Flow Control | Electronic Mass Flow Control (MFC) |
| GC Compatibility | Universal interface for all major GC systems |
| Software Interface | Touchscreen GUI with graphical workflow navigation |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TurboMatrix HS |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Sample Vial Heating Range | 35–210 °C (1 °C increments) |
| Pressure Control Options | Manual (0–60 psig) or Electronic Pneumatic Control (EPC/PPC) |
| Detection Limit Enhancement | Integrated Focused Cryo-Trap for analyte enrichment |
| Typical Application Performance | ≤1.5% RSD for 0.4% aqueous ethanol |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | HS-40 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 35–210 °C |
| Valve Temperature Control Range | 35–210 °C |
| Loop Volume | 1 mL |
| Sample Tray Capacity | 16 / 40 / 110 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Sampling Technique | Pressure-Balanced Headspace Injection |
| Compatible GC Interfaces | Universal (via standard GC inlet septumless or split/splitless ports) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PerkinElmer DSC 8500 coupled with EXFO® UV Curing System |
| Pricing | Available upon request |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Wavelength Accuracy | ±0.15 nm |
| Baseline Stability | ±0.002 A/30 min (static) |
| RSD (Repeatability) | ≤0.6% for Cu (air-acetylene), ≤1.0% for Cu (LPG-air) and Ba (N₂O-acetylene), ≤2.0% for Cu and Cd (graphite furnace) |
| Characteristic Concentration | Cu < 0.02 µg/mL/1% (air-acetylene & LPG-air), Ba < 0.15 µg/mL/1% (N₂O-acetylene) |
| Detection Limit | Cu < 0.004 µg/mL (flame), Cd < 0.4 pg (graphite furnace) |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Cu Sensitivity | >0.3 A at 5 ppm |
| Precision (RSD) | <0.4% |
| Cu Detection Limit | <0.004 µg/mL |
| Baseline Drift | <0.0008 A/30 min |
| Peak-to-Peak Baseline Noise | <0.0008 A/30 min |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Model | AA990 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Dual-Beam |
| Condition | Professionally Refurbished & Fully Qualified |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | CPG2/CPG2S |
| Instrument Type | Graphite Furnace Atomic Absorption Spectrometer (GFAAS) |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp Dual-Beam Background Correction |
| Detection Limits | Pb: 0.02 mg/kg, Cd: 0.002 mg/kg |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | G5 |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +7°C to 400°C |
| Max. Number of Simultaneous Inlet/Detector Mounts | 3 |
| Temperature Program Steps | 10-step |
| Inlet/Detector Configuration Flexibility | Modular |
| Carrier Gas Control | Digital Precision Flow/Pressure Regulation |
| Compliance | Designed to meet core requirements of ISO/IEC 17025, ASTM D3606, USP <621>, and FDA 21 CFR Part 11 for data integrity |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | G600 |
| Temperature Control Range | 7 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min (adjustable in 0.1 °C increments) |
| Maximum Injector Temperature | 450 °C |
| Injector Configuration | Up to three independently configurable inlets |
| Column Oven Cooling | Forced-air active cooling |
| Detector Options | FID, TCD, ECD, PID (field-selectable) |
| Compliance | GLP/GMP-ready software audit trail, 21 CFR Part 11–compatible data handling |