Chemical Analysis Instruments
Filter
Showing 6751–6780 of 10733 results
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Customized-6 |
| Pricing | Available Upon Request |
| Brand | PERIC |
|---|---|
| Model | GNF-TR-DP |
| Sensor Principle | Ultra-Thin Aluminum Oxide Capacitive |
| Measurement Range | –100 °C to +20 °C (Td) |
| Accuracy | ±2 °C @ +20 °C to –60 °C Td |
| Repeatability | ±0.5 °C |
| Stability | ±1% F.S. / 7 days |
| Response Time (63% / 90%) | 5 s / 10 s (–60 °C → –20 °C Td) |
| Explosion Protection | Ex db IIC T6 Gb (ATEX-compliant) |
| Ingress Protection | IP66 |
| Power Supply | 24 V DC |
| Communication Interface | TTL-level Serial Port |
| Analog Output | 4–20 mA (hardware-ready, software-configurable) |
| Mechanical Interface | M20×1.5 thread (display unit) |
| Operating Ambient Temperature | –10 °C to +50 °C |
| Relative Humidity | <90% RH (non-condensing) |
| Sample Pressure | Atmospheric ±10% (vented to ambient) |
| Sample Flow Rate | 3–5 L/min |
| Sensor Lifetime | >2 years (normal operation) |
| Instrument Lifetime | >5 years (normal operation) |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PR-GLRSA |
| Quotation | Upon Request |
| Detection Channels | 2 (simultaneous) |
| Target Gases | H₂, CO, C₃H₈, C₃H₆ |
| Concentration Ranges | H₂: 0–50% vol, CO: 0–10% vol, C₃H₈: 0–50% vol, C₃H₆: 0–80% vol |
| Accuracy | ≤ ±3% FS |
| Response Time | ≤ 30 s |
| Explosion Protection | Ex db ec ib pzc II C T3 Gc (Positive-Pressure Purged & Pressurized) |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V / 50 Hz, ≤ 800 W (host only) |
| Purge Gas | Clean, oil-free, dry, particle-free compressed air, 0.4–0.8 MPa |
| Brand | PERIC |
|---|---|
| Model | PR-LM |
| Type | Portable / Handheld Raman Spectrometer |
| Origin | Hebei, China |
| Manufacturer | PERIC Instrument Co., Ltd. |
| Measurement Range | 0–100% (v/v) |
| Detection Limit | 1 µmol/mol |
| Accuracy | ±0.1% (full scale) |
| Analysis Time | 1–300 s (user-configurable) |
| Sample Inlet | Integrated diaphragm pump |
| Dimensions (L×W×H) | 557 × 420 × 330 mm |
| Weight | <23 kg |
| Target Gases | H₂, N₂, O₂, CO, CO₂, CH₄, NH₃, H₂O, H₂S, C₂H₂, C₂H₄, C₂H₆, C₃H₆, and other hydrocarbons and inorganic gases |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Region | Domestic (China) |
| Model | PR-LR |
| Pricing | Upon Request |
| Gas Detection Range | N₂, O₂, H₂, CH₄, CO, CO₂, C₂H₆, C₂H₄, C₂H₂, C₃H₈, C₃H₆, C₄H₁₀, NO, NO₂, SO₂, H₂S |
| Accuracy | ≤±1% FS for components >1% full scale |
| Resolution | ≤0.01% (for >1% FS) |
| Analysis Time | 10–30 s (adjustable) |
| Laser Wavelength | 532 nm |
| Laser Linewidth | ≤0.1 nm |
| Spectral Range | 0–4200 cm⁻¹ |
| Spectral Resolution | 5 cm⁻¹ |
| Power Supply | 220 VAC, 50 Hz |
| Max. Power Consumption | ≤300 W |
| Operating Temperature | 10–35 °C |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PR-RM |
| Instrument Type | Online Raman Spectrometer |
| Gas Species | Benzene, Nitrogen, Hydrogen, Carbon Dioxide, Carbon Monoxide, Carbonyl Sulfide, Hydrogen Sulfide, Oxygen, Methane |
| Range | 0–100 %vol |
| Detection Limit | ≤50–100 ppm (gas-dependent) |
| Accuracy | ≤2 %FS |
| Measurement Cycle | 1–30 s (adjustable) |
| Sampling Method | Pump-aspirated with integrated pre-treatment |
| Environmental Robustness | Rated for high-pressure, high-temperature, high-humidity, high-dust, and hazardous-area operation |
| Maintenance | Consumable-free design |
| Brand | PERIC |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RGA100 / RGA200 |
| Principle | Electron Ionization (EI) Quadrupole Mass Spectrometry |
| Mass Range | 0–200 amu |
| Minimum Sampling Interval | 0.05 amu |
| Mass Resolution (FWHM) | < 0.5 amu |
| Ion Source | EI Source with Yttria-Coated Iridium Filament (Filament Current: 0–4 A) |
| Detector | Electron Multiplier (Gain > 10³) |
| Scan Speed | 5–1000 ms per data point |
| Compliance | Designed for UHV and HV vacuum environments |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | 210VGP |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Single-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu ≤ 0.005 mg/L |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±0.1 nm |
| Slit Widths | 0.2 / 0.7 / 2.0 nm |
| Background Correction | Deuterium Lamp (190–350 nm) and Self-Reversal HCL (190–900 nm) |
| Atomization | Air/Acetylene, N₂O/Acetylene, Ar/H₂ premixed flame |
| Furnace Max Temp | 3000 °C in <1 s |
| Data Interface | RS-232C, IEEE-488 (GPIB), Parallel Printer Port |
| Dimensions (L×W×H) | 991 × 279 × 305 mm |
| Net Weight | 23 kg |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 2400 Series II |
| Analysis Modes | CHN, CHNS, O |
| Typical Analysis Time | 4–8 min per mode |
| Sample Weight Range | 1–2 mg (CHN/CHNS), matrix-dependent for O |
| Detection Principles | Combustion–Reduction–Gas Chromatography–Thermal Conductivity Detection (TCD) |
| Gas Requirements | Helium or Argon carrier gas |
| Compliance | Designed for GLP/GMP environments |
| Software | Elemental Analyzer Data Manager (EADM) v3.x |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | 2400 |
| Operating Modes | CHN, CHNS, O |
| Analysis Time | 4–8 min |
| Accuracy (CHN/CHNS/O) | ≤0.3% |
| Precision (CHN/CHNS/O) | ≤0.2% |
| Detection Range (C/H/N/S/O) | 0.001–6.0 mg |
| Combustion/Reduction/Pyrolysis Furnace Temp | 100–1800 °C |
| Carrier Gases | He, Ar |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 411 |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Mode Flame/GF-AAS |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | D₂ Lamp + AC Zeeman |
| Spectral Resolution | 0.1 nm |
| Sensitivity | Flame (Cu): ≤0.02 µg/mL |
| GF-AAS (Cd) | ≤5.0×10⁻¹³ g |
| Precision (RSD) | Flame (Cu): ≤0.45% |
| GF-AAS (Cd) | ≤3.0% |
| Detection Limit | Flame (Cu): ≤0.003 µg/mL |
| GF-AAS (Cd) | ≤1.0×10⁻¹² g |
| Baseline Stability | ≤0.002 A/30 min (static) |
| Lamp Turret | 8-position Auto-rotating |
| Graphite Furnace | Transversely Heated |
| Magnetic Field | AC Zeeman, 0.6–1.1 T adjustable in 0.1 T increments |
| Optional Features | Integrated Graphite Furnace Viewing System |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 600 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal |
| Resolution | 0.3 nm |
| Sensitivity | Cu 5 ppm, Absorbance > 0.3 A |
| Repeatability (RSD) | < 0.3% |
| Detection Limit | Cu ≤ 0.006 mg/L |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | AAnalyst 800 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Automatic Deuterium/Hollow Cathode Lamp (D₂/HCL) |
| Spectral Resolution | 0.3 nm |
| Sensitivity | ≥ 0.3 A for 5 ppm Cu solution |
| Precision (RSD) | < 0.3% |
| Detection Limit (Cu) | ≤ 0.006 mg/L |
| Compliance | ASTM E1921, ISO 7185, USP <731>, FDA 21 CFR Part 11–ready software environment |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Gas Consumption | <8 L/min Ar (typical operational mode) |
| Startup Time | <5 minutes from cold start to analysis-ready |
| Dual-View Capability | Axial and Radial Simultaneous Observation without Sensitivity Loss |
| Linear Dynamic Range | Up to 9 orders of magnitude |
| Detector | Back-Illuminated CCD with On-Chip Background Correction |
| Plasma Technology | Flat Plate™ RF Generator and PlasmaShear™ Air-Based Tail Flame Elimination |
| Torch Orientation | Vertical, Tool-Free Adjustable Base with Interchangeable Injector Tubes |
| Software Platform | Syngistix for ICP-OES (21 CFR Part 11 Compliant) |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Avio 500 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Argon Consumption | <10 L/min (typical operational mode) |
| Plasma Orientation | Dual-View (Axial & Radial) |
| Plasma Technology | Flat Plasma™ |
| Background Correction | Real-Time Synchronous Background Correction |
| Detection Capability | Multi-element, simultaneous quantitative analysis of metals and some non-metals in liquid samples |
| Software Platform | Syngistix™ for ICP-OES |
| Brand | PerkinElmer |
|---|---|
| Model | Avio 550 |
| Origin | Imported |
| Configuration | Refurbished Unit |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Plasma Observation | Dual-view (Axial and Radial) |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Nebulization System | 4-channel, 12-roller peristaltic pump |
| Plasma Torch Design | Vertical, tool-free, maintenance-free torch with integrated tail-flame cutoff |
| Argon Consumption | Ultra-low |
| Diagnostic Capability | Real-time plasma imaging via integrated color plasma camera |
| Data Acquisition | Universal Data Acquisition (UDA) — full-wavelength, simultaneous, time-resolved detection |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio 550/560 |
| Pricing | Upon Request |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Configuration | Dual-View (Axial and Radial) |
| Detection Technology | Solid-State CCD Detector Array |
| Gas Consumption | Ultra-Low Argon Flow (<10 L/min typical plasma gas) |
| Torch Design | Vertical, Tool-Free, Maintenance-Free Plasma Torch with Integrated Tail-Flame Suppression |
| Optical System | Flat-Field Echelle Spectrometer with UV-Visible Wavelength Coverage (165–900 nm) |
| Pump System | 4-Channel, 12-Roller Peristaltic Pump |
| Dimensions (W×D×H) | 76 × 84 × 87 cm |
| Camera Integration | Integrated Color Plasma Torch Imaging System for Real-Time Torch & Injector Monitoring |
| Brand | PerkinElmer |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Avio® 550 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Plasma Orientation | Vertical Torch Configuration |
| Software Platform | Syngistix™ for ICP |
| Sample Introduction System | Scott/Cross-Flow Nebulizer with Cyclonic Spray Chamber |
| Optional Capability | HF-Compatible Sample Handling |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Avio 200 |
| Instrument Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit | 0.003 ng/mL (typical, e.g., Mg II 279.553 nm) |
| Precision (RSD) | ≤1% at 1 µg/L |
| Stability (RSD over 4h) | ≤1% |
| Wavelength Range | 110–900 nm |
| Optical Resolution | ≤0.007 nm (FWHM at 200 nm) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 500 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Clarus 580 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Cooling Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 580 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Temperature Control Range | Ambient to 450 °C (oven) |
| Ramp Rate | Up to 120 °C/min |
| Cooling Rate | Down to ambient in <3.5 min (with optional cryo-cooling) |
| Carrier Gas Flow Range | 0–100 mL/min (He, H₂, N₂), electronic pressure/flow control (EPC) |
| Inlet Pressure Range | 0–100 psi |
| Total Inlet Flow Range | 0–120 mL/min |
| Inlet Operating Temperature | Up to 450 °C |
| Compliance | ASTM D3606, D1319, D5186 |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Clarus 590 / Clarus 690 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Food, Pharmaceuticals, Petrochemicals, Environmental Analysis) |
| Software Platform | TotalChrom™ Chromatography Data System (CDS) |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP Audit Trail Capabilities |
| Automation Platform | TurboMatrix™ MultiPrep Autosampler (Liquid, Headspace, SPME) |
| Flow Control Technology | Swafer™ Micro-Channel Pneumatic Control |
| Detector Options | FID, TCD, ECD, NPD, FPD, PID |
| Inlet Types | Split/Splitless, PTV, Cold On-Column, Packed Column |
| Column Oven | Patented concentric exhaust design (Clarus 690) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 600 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient to 450 °C |
| Maximum Ramp Rate | 140 °C/min (programmable up to 160 °C/min) |
| Cooling Rate | 450 °C to 50 °C in <2 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 450 °C (PSS injector up to 500 °C) |
| Injector Pressure Range | 0–970 kPa |
| Injector Total Flow Range | 0–1200 mL/min |
| FID Detection Limit | <3×10⁻¹² g C/sec (n-nonane, S/N = 2:1) |
| Oven Operating Range (with cryogenic cooling) | –90 °C to 450 °C |
| Temperature Programming | 9 ramps / 10 steps |
| Injector Types Supported | Packed Column (PKD), Split/Splitless Capillary (CAP), Programmable Temperature Vaporization (PSS) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Clarus 680 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Oven Cool-Down Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus 680 GC |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Clarus 680 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down | 450 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus SQ 8 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC/MS Configuration | Conventional Gas Chromatography–Mass Spectrometry System |
| Mass Range | Not Specified |
| Resolution | Not Specified |
| Sensitivity | Not Specified |
| Scan Speed | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | DRC-e |
| Mass Analyzer Type | Quadrupole |
| Resolution (FWHM at m/z 202) | ≤ 0.8 amu |
| Detection Limit | sub-ppq ng·L⁻¹ |
| Sensitivity | Be ≥ 5 Mcps/(mg·L⁻¹), In ≥ 30 Mcps/(mg·L⁻¹), Bi ≥ 20 Mcps/(mg·L⁻¹) |
| Vacuum System | Dual mechanical pumps + dual turbo-molecular pumps (total pumping speed > 380 L/min) |
| Linear Dynamic Range | 9 orders of magnitude |
| DRC Gas Options | H₂, He, CH₄, NH₃, O₂, N₂O, CO₂ |
| Interference Reduction Efficiency | > 10⁷-fold |
| Chemical Resolution | > 150,000 |
| Isotopic Ratio Precision (¹⁰⁷Ag/¹⁰⁹Ag) | < 0.08% RSD |