Chemical Analysis Instruments
Filter
Showing 751–780 of 4337 results
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-2 |
| Instrument Type | Two-Stage Thermal Desorber, Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Count | 1 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve & Injection Port Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature | −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-50D |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Desorption Temperature Range | –35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | –35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | DK-400 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Manual Operation |
| Vial Heating Range | Ambient to 250 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Sample Loop Volume | 1.0 mL |
| Vial Capacity | 9 positions |
| Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-7890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5 °C above ambient to 420 °C (1 °C increment programmable) |
| Maximum Oven Operating Temperature | 400 °C |
| Heating Rate | Up to 40 °C/min |
| Cooling Rate | 280 °C → 50 °C in ≤8 min |
| Carrier Gas Flow Control Range | 0–50 mL/min |
| Carrier Gas Pressure Control Range | 0–0.35 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.35 MPa |
| Total Injector Flow Setting Range | 0–500 mL/min |
| Temperature Stability (≤180 °C) | ±0.01 °C |
| Temperature Stability (full range) | ±0.1 °C |
| Programmable Temperature Ramping | 7-stage |
| Independent Temperature Control | Dual vaporizers (capillary & packed column) |
| Detector Configuration | FID (Hydrogen Flame Ionization Detector) |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤5×10⁻¹⁴ A |
| FID Drift | ≤1×10⁻¹³ V/h |
| FID Linear Dynamic Range | ≥10⁷ |
| Column Compatibility | Up to three packed columns or two capillary columns simultaneously |
| Detector Capacity | Up to three detectors + methanizer |
| Optional Features | Integrated AD conversion circuit, cryogenic oven operation (dry ice/liquid nitrogen), dual rear doors with intelligent control, ceramic or quartz jet nozzles |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-GC-901 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-Down Rate | 0.1–80 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | Ambient to 450 °C |
| Injector Pressure Setpoint Range | 0–0.6 MPa |
| Injector Total Flow Setpoint Range | 0–100 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmable Temperature Steps | 16 stages |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 detectors (FID, TCD, ECD, FPD, NPD selectable) |
| Injection Modes | Packed column, capillary column, valve injection, headspace (with optional autosampler), thermal desorption |
| EPC/EFC Modes | Constant-flow and constant-pressure |
| Supported Gases | N₂, H₂, Air, He, Ar |
| EPC Pressure Resolution | 0.01 psi |
| EPC Flow Resolution | 0.01 mL/min |
| Communication Interface | 10/100 M adaptive Ethernet with embedded TCP/IP stack |
| Software | iBrainChrom workstation supporting up to 253 concurrent GC systems, 21 CFR Part 11 compliance (audit trail, role-based user permissions, electronic signatures), Modbus RTU protocol for DCS integration |
| Brand | APL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 8°C above ambient to 425°C |
| Oven Ramp Rate | Up to 75°C/min |
| Carrier Gas Pressure Control Range | 0–689.47 kPa (0–100 psi) |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–689.47 kPa |
| Injector Total Flow Setting Range | 0–100 psi |
| Brand | APL / Applied Photonics Ltd |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gemmology |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Wavelength | 266 nm |
| Pulse Energy | >20 mJ per pulse |
| Repetition Rate | Up to 10 Hz |
| Spectral Range (configurable) | 185–1000 nm |
| Number of Spectrometer Channels | Up to 8 |
| Imaging | Dual high-resolution color cameras (top-view + side-view, orthogonal to laser axis) |
| Sample Chamber | Modular — SC-2L manual chamber standard |
| Gas Purge | External inert gas interface (Ar, N₂, He, air) |
| Software | LIBSoft™ v5.x (2-year free upgrade included) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-12 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 250 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Loop Volume | 2 mL |
| Vial Capacity | 12 positions |
| Vial Size | 20 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (also compatible with 10 mL) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.4 MPa (adjustable) |
| Backflush Flow Rate | 0–400 mL/min (adjustable) |
| Temperature Stability | < ±0.1 °C |
| Precision | RSD ≤ 1% (200 ppm ethanol in water, n = 5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (standard), 10 mL (optional) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Loop Volume | 1 mL |
| Pressure Control Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Temperature Stability | < ±0.1 °C |
| Precision | RSD ≤ 1% (200 ppm ethanol in water, n = 5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HS-45 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Ambient to 260 °C (1 °C increments) |
| Valve Temperature Control Range | Ambient to 240 °C (1 °C increments) |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Vial Capacity | 45 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 80 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 260 °C (1 °C increments) |
| Valve Temperature Range | Ambient to 240 °C (1 °C increments) |
| Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Independent Heated Zones | Sample oven, injection valve, transfer line, and needle |
| Agitation | Adjustable speed, integrated into each of 15 heated positions |
| System Purge | Automatic inert gas flush after each injection |
| Leak Detection | Real-time vial presence verification |
| Software Interface | 7-inch touchscreen with bilingual (English/Chinese) UI, method storage, real-time GC status display (carrier gas & pressurization pressure), AFM-based flow monitoring |
| Compliance Support | Designed for GLP/GMP environments with audit-ready method logging, event timestamping, and system self-test at power-on |
| Mechanical Architecture | Dual three-axis rotary gantry for precise vial handling, piercing, sampling, and injection |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 250 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Loop Volume | 2 mL |
| Vial Positions | 9 |
| Vial Capacity | 20 mL |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | < ±0.1 °C |
| RSD (Repeatability) | < 1.5% |
| Pressurization Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–20 mL/min (adjustable) |
| Interface | Touchscreen with Time-Programmed Sequence Control |
| GC Synchronization | Supported via TTL or external trigger |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HS-Auto126 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 280 °C |
| Valve Temperature Control Range | Ambient to 280 °C |
| Sample Loop Volume | 1 mL / 2 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 126 positions |
| Vial Format | 20 mL standard (10 mL optional) |
| Sample Zone Heating Range | Ambient to 260 °C |
| Valve & Transfer Line Heating Range | Ambient to 220 °C |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Pressurization Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Vial Heating Positions | 15 |
| Oscillation Mode | Vertical wave-like agitation during equilibration |
| Display | 7-inch capacitive touchscreen |
| Method Storage | Preloaded compliance methods (e.g., EPA 502.2, USP <467>, ISO 11843-3) |
| Brand | APL/Applied Photonics Ltd |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 150-10 |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy | >20 mJ |
| Laser Wavelength | 1064 nm |
| Repetition Rate | 10 Hz (150 mJ) or 20 Hz (120 mJ) |
| Plasma Light Collection Channels | 6 or 8 |
| Spectrometer Support | Up to 8 independent spectrometers |
| Spectral Range | ~182–1016 nm |
| Sample Chamber Options | Modular, motorized multi-axis stage, open-beam configuration |
| Gas Purge | Compatible with Ar, N₂, He, or air supply |
| Optional Imaging Kit | IMG-HR (2.5 MP color imaging) |
| Software | LIBSoft™ (free updates for 2 years) |
| Host Computer | External laptop or desktop required (specifications available upon request) |
| Brand | APL/Applied Photonics Ltd |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | LIBS Probe 60 |
| Instrument Type | Handheld |
| Integration | Integrated Unit |
| Laser Pulse Energy | 50–60 mJ |
| Operating Depth | 10–30 m underwater |
| Laser Source | Air-Cooled, Flashlamp-Pumped Passive Q-Switched Nd:YAG |
| Repetition Rate | Up to 1 Hz |
| Gas Purge Mechanism | Compressed Air Jet for Optical Path Drying |
| Brand | APL Optol |
|---|---|
| Model | PT-75D |
| Sample Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Sample Heating Range | Ambient to 120 °C |
| Sample Vial Cooling | −30 °C |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Purge Flow | 0–100 mL/min (adjustable) |
| Desorption Time | 1–3 min |
| Bake-out Temp | Up to 250 °C |
| Vial Format | 40 mL |
| Brand | APL Optolab |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | APL-PTC30 |
| Sample Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | −30 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Desorption Time | 1–3 min |
| Bake-out Temperature | Up to 250 °C |
| Trap Desorption Efficiency | Optimized for VOCs with C2–C12 volatility range |
| Compliance | ASTM D6866, EPA Method 502.2, EPA Method 524.2, EPA Method 8260D, HJ 605–2011, HJ 639–2012, HJ 686–2014, HJ 713–2014, HJ 735–2015, HJ 866–2017, HJ 893–2017, HJ 896–2017, HJ 1020–2019, SL 393–2007 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | APL-TD25 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | −35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | −35 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 25 adsorption tubes |
| Brand | APL Optolong |
|---|---|
| Model | APL-TD-2D |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cryo-Focusing Trap Temperature | −20 °C (Peltier-cooled) |
| Analyte Recovery Rate | >98% |
| Sample Position Capacity | 1 tube per run |
| Valve System | Motorized 6-Port Rotary Valve + Solenoid Valves |
| Sample Tube Standard | 89 mm length × 6.4 mm OD, max. 420 °C tolerance |
| Flash Heating Rate (2nd Stage) | >3000 °C/min |
| Transfer Line Temp Control | Ambient to 260 °C, ±1 °C |
| GC Trigger Output | TTL-compatible synchronous pulse |
| Brand | APL Optolong |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-50A |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automatic |
| Desorption Temperature Range | −35 °C to 400 °C |
| Valve & Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 50 positions |
| Brand | APL Optolong |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD20N |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | –35 °C to 400 °C |
| Cold Trap Temperature Range | –35 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 20 adsorption tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PT30D |
| Instrument Type | Water & Soil Integrated VOC Analyzer |
| Sample Tray Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | –30 °C |
| Desiccant Trap Temperature | Ambient to 240 °C |
| Valve & Transfer Line Temperature | Ambient to 220 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Vial Volume | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APL-PTC100 |
| Instrument Type | Water & Soil VOC Analysis System |
| Sample Tray Capacity | 1 position |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 220 °C |
| Sample Heating Temperature Range | Ambient to 220 °C |
| Sample Vial Cooling Temperature | 20 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | APL-TC-20 |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0.3–3 L/min |
| Tube Capacity | 20 tubes |
| Temperature Accuracy | ±1 °C |
| Timer Range | 1 min to 99 h 99 min |
| Flow Adjustment Range | 0–3 L/min |
| Simultaneous Activation | 1–20 adsorption tubes |
| Brand | APM |
|---|---|
| Origin | Germany |
| Model | MT 1000 |
| Product Type | Online Dew Point / Trace Moisture Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±0.4 ppm or ±5% of reading |
| Range | 0–2000 ppm H₂O |
| Resolution | 0.1 ppm |
| Display | Color touchscreen with independent keypad control |
| Analog Output | 4–20 mA (field-scalable) |
| Alarm Output | Relay (NO/NC), fully configurable across full scale |
| Power Supply | 220 VAC, 50 Hz, 1×1.0 A fuse |
| Enclosure Options | Wall-mount, benchtop, rack-mount, portable (mains-powered only) |
| Dimensions | 320 × 240 × 230 mm (W×H×D) |
| Weight | ~5 kg |
| Sensor Cell Material | PVDF and stainless steel |
| Electrode Material | Platinum |
| Sample Flow Rate | 20 NL/h or 100 NL/h (user-selectable) |
| Sample Pressure (at sensor) | ≤200 mbar |
| Sample Temperature | +5 °C to +65 °C |
| Response Time | <1 s |
| Gas Fitting | 6 mm compression fitting |
| Probe Cable | Standard 1.4 m (extendable up to 150 m) |
| Electrical Connector | Binder type |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MS100 |
| Spectral Range | 380–780 nm |
| Spectral Resolution | 1 nm |
| FWHM | ~12 nm |
| Wavelength Repeatability | ±1 nm |
| PPFD Range | 0.1–3,500 µmol/m²/s |
| Illuminance Range | 5–190,000 lx |
| Illuminance Accuracy | ±5 % (Illuminant A, 2856 K, 20,000 lx) |
| Chromaticity Accuracy | ±0.0025 in CIE 1931 x,y |
| CCT Accuracy | ±2 % |
| CRI Accuracy | ±1.5 % |
| Diffuse Rejection | −25 dB |
| Integration Time | 6–1,000 ms |
| Operating Temperature | 0–35 °C (RH ≤70 %, non-condensing) |
| Storage Temperature | −10–40 °C (RH ≤70 %, non-condensing) |
| Display | 0.96″ 128×64 monochrome OLED |
| Battery | 700 mAh / 3.7 V rechargeable Li-ion |
| Weight (with battery) | 70 g ±5 g |
| Dimensions | 90 × 30 × 32.2 mm |
| Data Storage | microSDHC up to 32 GB (supports ≥120,000 Excel files) |
| Connectivity | Mini-USB 2.0, Bluetooth 3.0/4.0 (iOS & Android compatible) |
| Software | Apogee InSight (Windows, macOS, iOS, Android) |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | PS-100 / PS-200 / PS-300 |
| Price | Upon Request |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | PS-200 |
| Spectral Range | 190–850 nm |
| Calibration Wavelength Range | 300–850 nm |
| Wavelength Resolution | 0.85 nm |
| Detector | 2048-pixel CCD |
| Grating Density | 590 lines/mm |
| A/D Conversion | 16-bit |
| Signal-to-Noise Ratio | 1000:1 |
| Stray Light | 0.02% at 435 nm |
| Repeatability | <1% |
| Radiometric Accuracy | ±10% |
| Integration Time | 1 ms – 65 s |
| Angular Response (up to 80°) | ±5% |
| Interface | USB 2.0 |
| Power Supply | 5 V DC / 100 mA via USB |
| Operating Temperature | 0–60 °C |
| Optical Fiber Length | 2 m |
| Dimensions | 69 × 100 × 150 mm |
| Weight | 900 g |