Chemical Analysis Instruments
Filter
Showing 7921–7950 of 10669 results
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | SH-5 |
| Detection Parameter | Single-parameter (Conductivity) |
| Portability | Portable |
| Application Site | Field & Lab Environments |
| Conductivity Range | 0–200,000 µS/cm |
| Temperature Range | 0–60 °C |
| Accuracy | ±3% of reading |
| Minimum Resolution | 0.1 µS/cm (dependent on range) |
| Electrode Type | Digital Four-Electrode Graphite Sensor |
| Temperature Compensation | Automatic, ±0.1 °C |
| Communication Interface | RS485 |
| Response Time | ≤15 s |
| Display | Backlit LCD with Clock Function |
| Calibration | Single-point calibration |
| Electrode Cable Length | 3 m (customizable) |
| Operating Environment | 0–60 °C, non-freezing |
| Power Supply | Rechargeable Lithium-ion Battery |
| Dimensions | 20 × 10 × 3.5 cm |
| Net Weight | 610 g |
| Brand | Shengaohua |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Domestic |
| Model | SH-6600 / SH-6600PC |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05% T |
| Baseline Flatness | ±0.003 A |
| Baseline Noise (Dark) | ≤0.2% T |
| Drift | ≤0.2% T |
| Absorbance Range | –0.301 to 3.000 A |
| Transmittance Range | 0.00–200.0% T |
| Max Scan Speed (via PC Software) | 2500 nm/min |
| Wavelength Step Resolution | 0.1 nm |
| Wavelength Drive Mechanism | Stepper Motor |
| Sample Holder | Manual 4-cell Cuvette Holder (50 mm pathlength) |
| Data Interfaces | USB & RS-232 |
| Dimensions (W×D×H) | 485 × 438 × 190 mm |
| Net Weight | 4 kg |
| Operating Temperature | 5–45 °C |
| Brand | Haoyuan |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | XAFS2300+ |
| X-ray Source Power (XAFS mode) | 3 kW |
| X-ray Source Power (XES mode) | 50 W |
| Monochromatic Photon Flux | > 2 × 10⁶ photons/sec (at 7–9 keV) |
| Minimum Detectable Elemental Concentration | ≥ 1 wt% |
| Tunable X-ray Absorption Energy Range | 4.5–25 keV |
| Energy Resolution | 0.5–3 eV |
| Energy Scale Drift Reproducibility | < 50 meV per measurement session |
| Monochromator Architecture | Spherical-bent crystal on high-precision Rowland-circle geometry |
| Detector | High-resolution silicon drift detector (SDD) |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | 425 |
| Optical System | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 190–900 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | 4 nm |
| Stray Light | ≤0.01% T |
| Elements Measured | Na, K, Li, Ca |
| Linear Display | Dual-channel Digital LED |
| Output | 0.05–5.0 V Analog Signal |
| Interface | RS232 |
| Fuel Gas | Propane/Butane/Natural Gas (6 L/min at 15 PSI) |
| Detection Limits | Na/K: 20 ppb (S/N = 2) |
| Sensitivity | Na/K: 0.5 ppm |
| Li | 2 ppm |
| Ca | 5 ppm |
| Interference | <0.5% |
| Linearity | <1% |
| Precision (RSD) | ≤0.5% |
| Stabilization Time | ~15 s per reading |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M410 |
| Element Detection | Na, K, Li, Ca, Ba |
| Output Units | ppm, mg/L |
| Compliance | ISO 7635, ASTM D2189, USP <731> |
| Software Interface | RS-232 serial output for data logging |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | PFP7 / PFP7-C / WBW PLUS / 86LA |
| Measurement Range (PFP7-C) | Na 120–160 mmol/L (linearized), K 0–10.0 mmol/L |
| Detection Limit | Na < 0.2 ppm, K < 0.2 ppm, Li < 0.25 ppm, Ca < 15 ppm, Ba < 30 ppm |
| Repeatability | < 1% CV (20 consecutive samples, 10 ppm Na set to 50) |
| Linearity | Better than ±2% (3 ppm Na/K, 5 ppm Li set to 100) |
| Recorder Output | 1.00 V nominal at reading 100.0 |
| Power Supply | 90–125 V or 190–250 V, 50/60 Hz |
| Air Supply | Oil- and moisture-free, 6 L/min at 1 kg/cm² (14 psi) |
| Fuel Compatibility | Propane, butane, natural gas, LPG |
| Dimensions | 420 × 360 × 300 mm |
| Weight | 8 kg |
| Brand | Shida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ATD-50 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorber |
| Automation Level | Fully Automatic |
| Sample Capacity | 50 positions |
| Cooling Method | Electronic Peltier Cooling |
| Focusing Trap | Integrated Cryogenic Trap (No Liquid Cryogens Required) |
| Independent Temperature Control Zones | 5 (Adsorption Tube, Inlet Valve, Transfer Line, Focusing Trap, Desorption Zone) |
| Valve Type | Motor-Driven 6-Port Rotary Valve |
| Transfer Line Material | Deactivated Silica-Capillary Tubing (Imported, High-Inertness) |
| Maximum Valve Operating Temperature | 260 °C (Optional High-Temp Valve) |
| Valve–Line Junction | Heated Enclosure (Zero Cold Spot) |
| Interface | Dual TTL/Relay Trigger Outputs for GC/GCMS Synchronization |
| External Ready Signal Input | Supported |
| GC/GCMS Compatibility | Universal (Agilent, Thermo Fisher, Shimadzu, PerkinElmer, Waters, etc.) |
| Brand | Shida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HSP-64A |
| Instrument Type | Water & Soil Integrated Purge and Trap System |
| Sample Tray Capacity | 64 positions |
| Brand | Shida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PT-100 |
| Instrument Type | Water-and-Soil Integrated Purge and Trap System |
| Sample Tray Capacity | 100-position |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 5D Ultra-e |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Configuration | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) Coupled with Online Liquid Chromatography (LC) |
| Mass Range | m/z 2–1090 |
| Resolution | Unit Mass Resolution |
| Sensitivity | >15,000:1 (S/N, peak-to-peak, at 1 pg OFN) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Flame/Graphite Furnace AAS |
| Monochromator | Not Specified (Grating-based) |
| Optical System | Double-beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.3 nm |
| Sensitivity | 5 µg/mL Cu |
| Repeatability (RSD) | ≤0.3% |
| Detection Limit (Cu) | 0.006 mg/L |
| Compliance | ASTM D4294, ISO 11885, USP <231>, FDA Guidance for Elemental Impurities in Food |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AA-6880 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Optical System | Single-beam (automatically switches to double-beam mode for flame analysis |
| Monochromator | Grating-based, 0.3 nm spectral resolution |
| Detector | Solid-state photodiode array |
| Background Correction | Combined deuterium lamp and self-reversal (auto-absorption) method |
| Sensitivity | Flame: 0.1 µg/mL Pb |
| Graphite Furnace | 0.3 pg Pb |
| Detection Limit | Cu ≤ 0.006 mg/L (flame), sub-pg level for most elements (graphite furnace) |
| Precision (RSD) | < 0.3% for both flame and furnace modes |
| Lamp System | Integrated 8-position automatic lamp turret with dual-lamp simultaneous illumination capability |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | AA-7000 |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Concave Grating |
| Optical System | Double-Beam |
| Detector | Solid-State Detector |
| Background Correction | Deuterium Lamp + Zeeman Effect |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Wavelength Range | 185–900 nm |
| Monochromator | Czerny-Turner with 1800 grooves/mm grating |
| Spectral Bandwidth | 0.2, 0.7, 1.3, 2.0 nm (4-step automatic switching) |
| Optical System | Dual-beam for flame mode |
| Detector | Photomultiplier tube (PMT) |
| Background Correction | Simultaneous deuterium lamp (BGC-D₂, 185–430 nm) and fast self-reversal (BGC-SR, 185–900 nm) |
| Lamp Holder | 6-position, dual-lamp operation (1 pre-heating) |
| Dimensions (AA-7000F) | 700 × 588 × 714 mm, 72 kg |
| Dimensions (AA-7000G) | 700 × 580 × 538 mm, 65 kg |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Operating Environment | 10–35 °C, 20–80% RH (≤70% above 30 °C) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Flame AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Automatic D₂/Zeeman |
| Resolution | 0.3 nm |
| Sensitivity | ≥ 0.3 A for 5 ppm Cu solution |
| Repeatability (RSD) | < 0.3% |
| Detection Limit (Cu) | ≤ 0.006 mg/L |
| Condition | Factory-Refurbished & Performance-Verified |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | AA-7800 |
| Price Range | USD 42,000 – 85,000 (FOB China) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp + Self-Reversal Method |
| Spectral Resolution | 0.1 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Microscope |
| Resolution | 0.25 cm⁻¹ |
| Signal-to-Noise Ratio | 30,000:1 |
| Optical Magnification Range | 330× continuous (macro to micro, 10 mm × 13 mm to 30 µm × 40 µm) |
| Detector | Liquid Nitrogen-Cooled MCT (Mercury Cadmium Telluride) |
| Automation | Fully Motorized XYZ Stage with Digital Image-Based Auto-Targeting |
| Software | IRsolution with Integrated Chemical Imaging and Automated Contaminant Identification Algorithm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AIRsight |
| Instrument Type | Laboratory Benchtop System |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | AIRsight |
| Price Range | USD 270,000 – 405,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | ALTRACE |
| Configuration | Benchtop/Floor-standing |
| Instrument Type | Conventional ED-XRF |
| Application Scope | General-purpose |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Type | Imported Instrument |
| Model | AOC-30 Series |
| Instrument Category | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 150 positions (1.5 mL vials) |
| Minimum Injection Volume | 10 nL |
| Injection Needle Volume | Standard 10 µL (exchangeable with optional syringes) |
| Positioning Accuracy | Adjustable |
| Motion System | XYZ three-axis robotic arm |
| Needle Wash Modes | Six preconfigured wash methods + user-defined protocols |
| Replicate Injections per Sample | Up to 99 times |
| Brand | Shimadzu |
|---|---|
| Origin | Switzerland |
| Manufacturer | Shimadzu Corporation |
| Product Type | Multifunctional Autosampler |
| Model | AOC-6000 Plus |
| Motion System | XYZ 3-axis robotic arm |
| Needle Wash | Internal & external wall cleaning |
| Repeat Injection Capability | Unlimited |
| Compatible Sample Introduction Modes | Liquid injection, headspace (HS), solid-phase microextraction (SPME), SPME Arrow, and ITEX-DHS |
| Software Integration | Native control via LabSolutions and GCMSsolution |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation (21 CFR Part 11 compliant configuration available) |
| Sample Processing Functions | Automated standard curve preparation, internal standard addition, on-line derivatization, μSPE, and sequential method switching |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Brevis GC-2050 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa (7 programmable pressure segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | cGBS-2030 |
| Instrument Type | Gas Chromatography (GC) Gas Bag Autosampler |
| Maximum Sample Capacity | 12 positions |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTO-10AVP |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | EDX-700HS |
| Element Range | Na (11) to U (92) |
| Detection Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Configuration | Benchtop / Floor-standing |
| Application Focus | Geological & Mineralogical Analysis |
| Primary Excitation | Rh anode X-ray tube (5–50 kV, 1–1000 µA) |
| Sample Chamber | Ø300 mm × H150 mm |
| Beam Spot Size | 50 µm φ (with polycapillary lens) |
| Detector | Liquid-nitrogen-cooled Si(Li) |
| CCD Imaging | Dual-magnification optical system |
| Filter Exchange | Automated 5-position primary filter changer |
| Quantitative Methods | Fundamental Parameters (FP), Thin-Film FP, Background-corrected FP (BG-FP) |
| Mapping | Simultaneous multi-element scanning imaging |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | EDX-720 |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantitative Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ±0.1% RSD |
| Configuration | Benchtop or Floor-Standing |
| Application Sector | Geological & Mineralogical Analysis |
| Compliance | Designed for ISO/IEC 17025-aligned laboratories |
| Instrument Condition | Factory-refurbished, fully recalibrated and performance-verified |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | EDX-7200 |
| Configuration | Benchtop or Floor-Standing |
| Instrument Type | Conventional ED-XRF |
| Application Scope | General-Purpose |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantitative Concentration Range | 0.1 ppm – 100 wt% |
| Energy Resolution | ≤140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD (for major elements under standardized conditions) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EDX-8100 |
| Configuration | Benchtop & Floor-Standing Options |
| Application Scope | General-Purpose Elemental Analysis |
| Elemental Range | C (Z=6) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability | <0.1% RSD (Relative Standard Deviation) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Configuration | Benchtop/Floor-standing |
| Elemental Range | Al (13) to U (92) |
| Intended Use | Electronics Industry Applications |
| Compliance | Designed for ISO/IEC 17025-aligned QA/QC workflows |
| Condition | Factory-refurbished with full functional validation |