Chemical Analysis Instruments
Filter
Showing 781–810 of 4337 results
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | PS-300 |
| Spectral Range | 220–1100 nm |
| Calibration Range | 300–1100 nm |
| Wavelength Resolution | 1.5 nm |
| Detector | 2048-pixel CCD |
| Grating Density | 590 grooves/mm |
| A/D Conversion | 16-bit |
| Signal-to-Noise Ratio | 1000:1 |
| Stray Light | 0.02% at 435 nm, 0.2% at 220 nm |
| Repeatability | <1% |
| Radiometric Accuracy | ±10% |
| Integration Time | 1 ms – 65 s |
| Angular Response (up to 80°) | ±5% |
| Interface | USB 2.0 |
| Power | 5 V DC / 100 mA via USB |
| Operating Temperature | 0–60 °C |
| Fiber Optic Cable Length | 2 m |
| Dimensions | 69 × 100 × 150 mm |
| Weight | 900 g |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SS-120 |
| Spectral Range | 635–1100 nm |
| Spectral Sampling Interval | 1.0 nm |
| Spectral Resolution | 3.0 nm |
| Spectral Accuracy | ±0.5 nm |
| Spectral Repeatability | ±0.2 nm |
| A/D Conversion | 14-bit |
| Signal-to-Noise Ratio | 1500:1 |
| Stray Light | ≤0.25% at 850 nm |
| Noise Level | ≤3 counts |
| Integration Time | 10 ms – 10 s |
| Linearity | <1% or 0.5% |
| Quantum Efficiency | >10% (λ < 1030 nm) |
| Radiometric Repeatability | <1% (λ < 1020 nm) |
| Cosine Response Error | ±5% at 75° zenith angle |
| Field of View | 25° or 150° (downward-facing configuration) |
| Operating Temperature | −20 to +70 °C |
| Relative Humidity | 0–100% RH |
| Power Consumption | 1 W (USB-powered) |
| Current Draw | 190 mA |
| Weight | 300 g |
| Dimensions | 89.3 × 50.8 × 38.1 mm (H × W × L) |
| Communication Interface | USB |
| Software Compatibility | Windows XP and later |
| Irradiance Calibration Uncertainty | ±5% |
| Temperature Coefficient | −0.1 ± 0.1 %/°C |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SU-200-SS / SU-202-SS / SU-205-SS |
| Spectral Range | 300–400 nm |
| Output Types | 0–10 mV (SU-200-SS), 0–2.5 V (SU-202-SS), 0–5 V (SU-205-SS) |
| Calibration Unit | W·m⁻² (irradiance) |
| Measurement Range | 0–100 W·m⁻² |
| Spectral Bandwidth | 300–400 nm |
| Wavelength Accuracy | ±5% |
| Stray Light Rejection | ±1% |
| Operating Temperature | −35 to +85 °C |
| Relative Humidity Range | 0–100% RH |
| Housing IP Rating | IP68 |
| Cable Length | 5 m |
| Sensor Diameter × Height | Φ30.5 × 37 mm |
| Weight | 140 g |
| Long-Term Drift | <2% per year |
| Nonlinearity | <1% |
| Directional Response | ±2% at 45°, ±5% at 75° |
| Temperature Coefficient | 0.1% / °C |
| Calibration Uncertainty | ±10% |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Model Designation | Chirascan |
| Compliance | CE, UKCA |
| Optical Path | Dual-beam, photoelastic modulator (PEM)-based |
| Wavelength Range | 170–900 nm |
| Temperature Control Range | −40 °C to +120 °C (with optional cryostat & Peltier units) |
| Data Acquisition Rate | Up to 500 points/sec |
| Signal-to-Noise Ratio | <0.005 mdeg (at 220 nm, 1 nm bandwidth, 1 s time constant) |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chirascan CPL |
| Instrument Type | Circular Dichroism / Circularly Polarized Luminescence Spectrometer |
| Optical Path Configurations | 90° and 180° fluorescence detection modes |
| Excitation Range | 170–900 nm (deep-UV capable with N₂ purge) |
| Monochromator | F/7 double-prism design |
| Polarization Optics | Dual high-fidelity polarization prisms |
| Data Acquisition | Digital signal processing (DSP) architecture with adaptive integration time control |
| Sample Compatibility | Liquids, powders, films, gels, turbid suspensions, and opaque solids |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Circular Dichroism (CD) and Synchronous Fluorescence Spectrometer |
| Model | Chirascan Plus |
| Detection Technology | Large-Area Avalanche Photodiode (LAAPD) Detector |
| Wavelength Range | 170–900 nm (CD), 200–900 nm (Fluorescence) |
| Sensitivity | Enhanced vs. standard Chirascan (LAAPD-enabled) |
| Automation | Optional unattended high-throughput configuration |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Model | Chirascan Q100 CD |
| Detection Range | 170–1700 nm |
| Optical Design | Dual Rochon Prism Monochromator |
| Detector Options | LAAPD (1200 nm), InGaAs (up to 1700 nm) |
| Automation Level | Fully Integrated, Unattended Operation |
| Compliance | Designed for GLP/GMP-aligned biophysical characterization |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | Stopped-Flow Accessory for Chirascan CD Spectrometer |
| Instrument Type | Circular Dichroism (CD) |
| Dead Time | ≤1.5 ms |
| Cuvette Volume | 20 µL (switchable 2 mm / 10 mm pathlength) |
| Compatibility | Fully integrated with Chirascan series CD spectrometers |
| Detection Modes | Stopped-flow CD, absorption, fluorescence, fluorescence polarization, diode array, quench-flow |
| Optional Modules | Multi-channel rapid mixing system, dual fluorescence detection, time-resolved absorption |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chirascan V100 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Price Range | USD 170,000 – 390,000 (estimated FOB UK) |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hellma |
| Price Range | USD 1,850 – 4,300 |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SUPR-CM |
| Price Range | USD 135,000 – 270,000 |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SUPR-DSF |
| Photomultiplier Tube Wavelength Range | 160 nm – 1200 nm |
| Atomizer Temperature Control Range | −50 °C to 150 °C |
| Throughput | 384 samples per thermal ramp (60–80 min) |
| Sample Volume | 10–20 µL per well |
| Sample Concentration Range | 0.05–250 mg/mL |
| Temperature Scan Range | 10 °C to 105 °C |
| Detection Method | Full-spectrum fluorescence acquisition with centroid-based analysis |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Stopped-Flow CD/Fluorescence/Absorption Spectrometer |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Pro-Data acquisition and kinetic analysis suite (FDA 21 CFR Part 11 compliant audit trail optional) |
| Detector Options | Photodiode array, dual photomultiplier tubes, fluorescence polarization module, CD-compatible stopped-flow cell |
| Mixing Systems | Single-, double-, or triple-syringe configurations |
| Temperature Control | ±0.1 °C over 5–40 °C range |
| Data Acquisition Rate | Up to 100 kHz (depending on detector configuration) |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Circular Dichroism (CD) Stopped-Flow Spectrometer |
| Detection Principle | Far-UV to Near-UV CD spectroscopy (170–450 nm) |
| Flow Precision | ≤1% RSD per injection |
| Dead Time | <1.0 ms (with optimized cell and drive system) |
| Temperature Control Range | 4–80 °C (±0.1 °C stability) |
| Data Acquisition Rate | Up to 20,000 points/sec (CD signal at single wavelength) |
| Compliance | ASTM E2915, ISO/IEC 17025–compliant operation framework, supports 21 CFR Part 11–ready audit trail via KineticStudio software |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Circular Dichroism (CD) Stopped-Flow Spectrometer |
| Application Domain | Transient Kinetics, Pre-Steady-State Reaction Analysis |
| Compliance Context | ASTM E259, ISO 17025 (for kinetic method validation), GLP/GMP-ready data audit trail support |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Circular Dichroism (CD) Stopped-Flow Spectrometer |
| Detection Options | Diode Array, Dual Fluorescence, Fluorescence Polarization, Quench-Flow, Multi-Channel Sequential Mixing, CD-Stopped-Flow Module |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200 |
| Price Range | USD 140,000 – 700,000 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy | 25–100 mJ |
| Wavelength Options | 1064 nm, 266 nm, 213 nm, 343 nm (femtosecond), 1030 nm (femtosecond) |
| Spectrometer Options | EN4, EN6, SHP, IHP, RHP (dual-spectrometer configurations supported) |
| Sample Cell Options | Standard Flex Chamber, Cryo Cell, FlexSeal LA, FlexSeal Chamber, THP Cell – Standard Washout, THP Cell – Fast Washout |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RESOchron SE/LR |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Pricing | Upon Request |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Model | RESOlution SE/LR |
| Laser Wavelength | 193 nm |
| Pulse Width (SE) | 5 ns |
| Pulse Width (LR) | 20 ns |
| Repetition Rate (SE) | 300 Hz |
| Repetition Rate (LR) | 20 Hz |
| Fluence (SE) | 20 J/cm² |
| Fluence (LR) | 45 J/cm² |
| Ablation Spot Size | 2–300 µm (SE), 2–380 µm (LR) |
| Sample Cell | S-155 Dual-Volume Constant-Volume Chamber |
| Software | GeoStar μGIS |
| Signal Smoothing | Integrated SQUID Device |
| Flame Monitoring | Real-time ICP torch status detection with automatic laser shutdown |
| Mercury Trap Mounting | Pre-installed position |
| Compliance | Compatible with GLP/GMP workflows, supports 21 CFR Part 11–compliant audit trails via optional software configuration |
| Brand | Apure |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FCY-100 |
| Price | USD 605 (converted from ¥4,250 at 1 USD ≈ ¥7.03) |
| Display | 192×64 dot-matrix LCD |
| Enclosure | Panel-mount housing |
| Power Supply | 24 VDC, 0.5 A |
| Power Consumption | ≤10 W |
| Measurement Range | 0.001–1.000 mm/a |
| Accuracy | ±0.001 mm/a |
| Response Time | 1 min |
| Output Signal | Isolated 4–20 mA current loop |
| Protection Rating | IP65 |
| Dimensions (H×W×D) | 144×144×90 mm |
| Panel Cutout | 138×138 mm |
| Weight | 0.8 kg |
| Operating Temperature | 0–50 °C |
| Relative Humidity | <85% RH (non-condensing) |
| Magnetic Interference | Minimal ambient magnetic fields beyond Earth’s geomagnetic field |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | 4TE |
| Measurement Principle | Chilled-Mirror Dew Point |
| Operating Temperature Range | 4–50 °C |
| Accuracy | ±0.003 aw |
| Repeatability | ±0.001 aw |
| Application | Laboratory-Grade Water Activity Analysis |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Model | Pre |
| Measurement Principle | Chilled-Mirror Dew Point |
| Operating Temperature Range | 4–50 °C |
| Repeatability | ±0.01 a<sub>w</sub> |
| Application | Laboratory-Grade Dew Point Water Activity Analyzer |
| Compliance | AOAC, FDA, ISO 21807, USP <1112>, ASTM F1980 |
| Sample Temperature Control | Precisely maintained at 25 °C (±0.1 °C) |
| Typical Measurement Time | < 5 minutes |
| Calibration | Factory-calibrated with NIST-traceable standards |
| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROS 1 |
| Pricing | Available Upon Request |
| Measurement Principle | Standard Gravimetric Loss-on-Drying (LOD) with Real-Time Mass Monitoring |
| Heating Method | Resistive Coil Conduction (Not Halogen or Microwave) |
| Sample Capacity | 9 Independent Positions |
| Temperature Range | 50–150 °C (1 °C Increments) |
| Balance Readability | 0.0001 g |
| Max Load per Pan | 50 g |
| Sample Weight Range | 1–15 g |
| Moisture Range | 0.1–100 % w/w |
| Accuracy | ±0.15 % |
| Repeatability (4 g) | ±0.05 % |
| Repeatability (10 g) | ±0.01 % |
| Compliance | AOAC 937.02, ASTM D4442, ISO 4463, USP <921>, FDA 21 CFR Part 11 Ready (with optional software audit trail) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQV-2200 |
| Pricing | Upon Request |
| Brand | Aragon Photonics |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BOSA-500 |
| Optical Band Coverage | O, S, C, and L bands |
| Optical Resolution | 10 MHz @ 1310 nm or 1550 nm (0.08 pm) |
| Wavelength Accuracy | ±0.5 pm @ C/C+L/S+C+L bands |
| Spurious-Free Dynamic Range (SFDR) | >80 dB |
| Core Technology | Stimulated Brillouin Scattering (SBS)-based tunable optical filtering |
| Integrated Tunable Laser Source (TLS) | Yes |
| Polarization-Resolved Spectral Measurement | Supported |
| Phase-Spectral Characterization Capability | Yes (e.g., chirp, eye diagram, constellation analysis) |
| Brand | ARC |
|---|---|
| Origin | Switzerland |
| Model | FT-NIR Rocket |
| Instrument Type | Portable |
| Spectral Range | 900–2600 nm (11000–3800 cm⁻¹) |
| Resolution | 4 cm⁻¹ (≤0.8 nm @ 1100 nm, ≤2 nm @ 1700 nm, ≤5 nm @ 2600 nm) |
| Wavenumber Accuracy | <1 cm⁻¹ @ 4000 cm⁻¹ (25±5°C) |
| Signal-to-Noise Ratio | >10,000:1 (RMS, full spectrum, single scan) |
| Dynamic Range | >3000:1 |
| Scan Speed | 1 spectrum/sec (averaging mode) |
| A/D Conversion | 24-bit |
| Detector | InGaAs photodiode array |
| Reference Laser | Integrated solid-state 850 nm laser |
| Optical Interface | SMA905, fiber input ≥1 mm core, NA = 0.2 |
| Power Supply | 5 V DC via USB 2.0 |
| Operating Temperature | 10–30 °C |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 850 g |
| Compliance | CE, RoHS, USB-IF certified |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Instrument Type | Laboratory FT-IR |
| Spectral Range | 5000–830 cm⁻¹ |
| Resolution | 0.5 cm⁻¹ (standard 4 cm⁻¹, optional down to 0.5 cm⁻¹) |
| Signal-to-Noise Ratio | > 1:40,000 (at 8 cm⁻¹, 60 s acquisition) |
| Detector | Peltier-cooled MCT (4-stage TE), ZnSe beamsplitter |
| Interface | USB 2.0 |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 1.8 kg |
| Operating Temperature | 10–40 °C |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-IR Rocket |
| Detector | Thermoelectrically Cooled HgCdTe (MCT) |
| Interferometer Type | Permanently Aligned Dual Corner-Cube Design |
| Reference Laser | Solid-State Stabilized Laser (PPM-level wavelength stability) |
| Spectral Range | Mid-Infrared (Typical 2–12 µm, configuration-dependent) |
| Optical Interface | Fiber-Coupled or Free-Space Input |
| Resolution | Up to 0.5 cm⁻¹ (configurable) |
| Scan Rate | Up to 10 scans/sec (typical) |
| Weight | < 1.2 kg |
| Dimensions | 120 × 85 × 65 mm |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-IR Rocket |
| Detector | Thermoelectrically Cooled MCT (2-stage or 4-stage) |
| Spectral Range | Mid-IR (typically 2.5–12 µm / 4000–833 cm⁻¹, configuration-dependent) |
| Resolution | 4 cm⁻¹ or 8 cm⁻¹ |
| Coupling Options | Fiber-optic (SMA-905 or FC/PC) and Free-space |
| Light Source | Integrated Broadband IR Emitter |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | USB 2.0, SDK for LabVIEW, Python, MATLAB |
| Brand | ARCoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-NIR 0.9–2.6 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Spectral Range | 900–2600 nm (3800–11,000 cm⁻¹) |
| Resolution | 4 cm⁻¹ |
| SNR | >200,000:1 (at 4 cm⁻¹, 60 s acquisition) |
| Wavelength Stability | <10 ppm long-term repeatability |
| Baseline Intensity Drift | <2% over 10 h (1100–2500 nm) |
| Detector | Extended-range InGaAs PIN photodiode (thermoelectrically cooled option available) |
| Data Acquisition Rate | 1 spectrum/s (continuous mode) |
| Interface | USB 2.0 (Ethernet optional) |
| A/D | 24-bit |
| Power | 7.5–12 V DC, 1–6 W |
| Operating Temperature | 5–40 °C |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 1.7 kg |