| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | CAGC-2030 |
| Price Range | USD 42,000 – 70,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Nexis GC-2030 Enhanced Edition |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤3.4 min (at 22 °C ambient) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Total Injector Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | Nexis GC-2030 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cool-down Time | ≤3.4 min (from 450 °C to 50 °C at ambient 22 °C) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Oven Ramp Rate | 0.01–250 °C/min |
| Oven Cool-Down Time | ~3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1300 mL/min He |
| Carrier Gas Pressure Control | 0–1035 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min He |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Nexis SCD-2030 |
| Instrument Category | Sulfur-Specific Chromatographic Detector |
| Flow Path Design | Horizontal Combustion Chamber with Ultra-Short Reaction Pathway |
| Maintenance Interval | Ceramic Reactor Tube Replacement in ≤5 Minutes |
| Automation Level | Fully Automated Startup, Vacuum Initiation, Gas Flow Optimization, Baseline Stabilization, Analysis Execution, and Shutdown Sequence |
| Compliance Ready | Designed for GLP/GMP environments with audit-trail-capable software integration |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Nexlock |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Off-Flavor Analyzer |
| Instrument Type | Triple Quadrupole Mass Spectrometer (GC-MS/MS) |
| Mass Range | 2–1090 u |
| Resolution | Unit Mass Resolution |
| Sensitivity | >20,000:1 (S/N, using chlorobenzene, m/z 112) |
| Scan Speed | 20,000 u/s |
| Chromatographic Configuration | Multi-column switching platform (three polarities: DB-5ms, DB-WAX, InertCap Pure-WAX) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PDA-5000 |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Number of Channels | 24 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Floor-standing |
| Excitation Method | Arc/Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Optical System | Czerny-Turner with Fixed Grating |
| Focal Length | 500 mm (typical for PDA-series) |
| Groove Density | 1200–2400 lines/mm (model-dependent) |
| Wavelength Range | 130–800 nm (vacuum UV to near-IR) |
| Number of Channels | Up to 60 pre-aligned PMT channels |
| Operating Environment | 10–30 °C, <80% RH non-condensing |
| Vacuum System | Continuous rotary vane pump with pressure stabilization |
| Spark Stand | Horizontal sliding enclosed design with stainless steel sample stage |
| Temperature Control | Thermostatically stabilized optical chamber at 38 ± 0.1 °C |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Floor-standing |
| Excitation Source | Arc/Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Optical Configuration | Paschen-Runge Mount |
| Focal Length | 750 mm (typical for PDA-series) |
| Grating Groove Density | 1200–2400 lines/mm (model-dependent) |
| Wavelength Range | 130–800 nm |
| Number of Fixed Channels | Up to 60 analytical channels |
| Nitrogen Detection Limit | ≤5 ppm in steel matrix |
| Compliance | ASTM E415, ISO 11577, JIS G 1253 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PDA-8000 |
| Configuration | Floor-standing |
| Excitation Source | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Peakintelligence |
| Chromatography Type | Conventional Gas Chromatography–Mass Spectrometry (GC-MS) |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Petrochemical Accessories Kit |
| Instrument Type | Laboratory Gas Chromatograph Accessories |
| Application Field | Petroleum & Petrochemical Industry |
| Key Components | G-VAPORIZER Flash Vaporizer |
| Compliance | Designed for ASTM D1319, D5769, D6730, ISO 6974, and USP <467> residual solvent methods |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PPSQ-51A / PPSQ-53A |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | Shimadzu PR-1000 |
| Temperature Range | Ambient |
| Reaction Tubing Material | FEP (Fluorinated Ethylene Propylene) |
| UV Source Lifetime | 9,000 hours |
| Derivatization Flow Path | Passive (No Pump-Driven Reagent Delivery) |
| UV Leakage Protection | Integrated Shielding with UV-Blocking View Window |
| Delay Volume | Optimized for Minimal Extra-Column Dispersion |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Detection Modes | Suppressed and Non-Suppressed Conductivity Detection |
| Application Scope | Trace Anion and Cation Analysis in Environmental, Pharmaceutical, Food, and Industrial Samples |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | Prominence Plus LC-20A |
| Instrument Category | Fast Liquid Chromatography System |
| Application Scope | General-purpose HPLC analysis |
| Maximum Operating Pressure | 44 MPa (LC-20AT) / 66 MPa (LC-20ADXR) |
| Flow Rate Precision | ≤0.06% RSD or ≤0.02 min SD |
| Injection Volume Range | 0.1–50 µL (standard), 0.1–2000 µL (optional) |
| Sample Tray Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient +10 °C to 85 °C (standard) |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Prominence Plus LC-30A |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.0001–10.0000 mL/min |
| Maximum Operating Pressure | 130 MPa |
| Flow Rate Precision | <0.06% RSD or 0.02 min SD (whichever is greater) |
| Injection Volume Range | 0.1–50 µL |
| Sample Capacity | 175 positions (1 mL vials) |
| Column Oven Temperature Range | Ambient ±10 °C to 85 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Prominence UFLC |
| Instrument Type | Ultra-Fast Liquid Chromatograph |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Prominence UFPLC |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Py-Screener |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Pyrolysis-Gas Chromatography Coupled with Mass Spectrometry (Py-GC/MS) |
| Mass Range | 1.5–1090 u |
| Resolution | Unit Mass Resolution |
| Sensitivity | >1500:1 (Signal-to-Noise Ratio, S/N) |
| Scan Speed | 20,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010 Plus |
| GC Platform | GC-2010 Plus AF |
| Mass Analyzer Type | Quadrupole (not Orbitrap) |
| Mass Range | m/z 1–1000 |
| Resolution | 1000–2000 (unit mass resolution at peak top) |
| Sensitivity | >300:1 (S/N, octafluoronaphthalene, full scan, 1 pg injected) |
| Scan Speed | 15,000 u/s |
| Detector | Electron Multiplier |
| Ion Source | EI/CI (dual-mode, standard) |
| Column Oven Cooling Rate | ≤3.5 min (from 300 °C to 50 °C) |
| Advanced Flow Technology (AFT) | Yes |
| Compliance | ASTM D5845, ISO 17025, USP <621>, FDA 21 CFR Part 11 (software-enabled) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC-MS Configuration | Conventional GC-MS |
| Mass Range | Not specified in source |
| Resolution | Not specified in source |
| Sensitivity | Not specified in source |
| Scan Speed | >10,000 u/sec |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QP2010 |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Type | Conventional GC-MS |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (unit mass resolution) |
| Sensitivity | >300:1 (S/N, full-scan, 1 pg octafluoronaphthalene) |
| Scan Speed | 150,000 u/s |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RF-10A |
| Price | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | RF-6000 |
| Wavelength Accuracy | ±1.0 nm |
| Spectral Bandwidth (Slit Width) | 1.0–20.0 nm |
| Optical Resolution | 1.0 nm |
| Sensitivity (S/N Ratio) | ≥1000:1 (RMS) |
| Wavelength Range | Excitation 200–900 nm, Emission 200–900 nm |
| Scan Speed | Up to 60,000 nm/min |
| Light Source | Long-life Xenon Lamp (2000 h typical lifetime) |
| Detector | Broadband Photomultiplier Tube (PMT), extended to 900 nm |
| Dispersion Element | Dual grating + interference filter system |
| Quantum Yield Measurement | Supported (absolute and relative) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RM-3000 |
| Instrument Type | Handheld Portable Raman Spectrometer |
| Spectral Range | 200–3000 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Spatial Resolution | 0.22 mm |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Repeatability | <1 cm⁻¹ |