Chemical Analysis Instruments
Filter
Showing 8161–8190 of 10669 results
| Brand | Elite |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model Series | Shodex |
| Pricing | Available Upon Request |
| Brand | Shodex |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RI-201 |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | HPLC |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.125–256 µRIU |
| Drift | ≤0.1 µRIU/h |
| Noise | ≤1 nRIU |
| Linear Range | ≥300 µRIU |
| Flow Rate (Typical) | 0.2–3.0 mL/min |
| Max Flow Rate (Water) | 10 mL/min |
| Cell Volume | 8 µL |
| Dead Volume (IN→Cell) | ~80 µL |
| Dead Volume (Cell→OUT) | ~600 µL |
| Total Dead Volume | ~690 µL |
| Temperature Control Range | 30–55 °C (1 °C increments), with dual-stage thermal regulation |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero Function | Full-range, fully automatic |
| Offset Adjustment Range | ±5 µRIU |
| Offset Resolution | 25 nRIU |
| Analog Output | DC 0–1 V (4 mV/µRIU or 16 mV/µRIU selectable) |
| Recorder Output | 0–10 mV/FS |
| Communication Interface | USB |
| Wetted Materials | SUS316 Stainless Steel, PTFE, Quartz Glass |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), ~12 kg |
| Brand | Shodex |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RI-201H |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Refractive Index Range | 1.00–1.75 |
| Detection Range | 0.25–512 μRIU |
| Drift | ≤0.2 μRIU/h (deionized water, 1 mL/min, purge off) |
| Linearity | ≥600 μRIU |
| Noise | ≤2.5 nRIU (deionized water, 1.5 s response) |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero | Full-range automatic zeroing |
| Offset Adjustment Range | ±10 μRIU |
| Offset Resolution | 50 nRIU |
| Cell Volume | 8 µL |
| Flow Rate Range | 0.2–3.0 mL/min (typical), up to 10 mL/min (water) |
| Max Backpressure | 50 kPa |
| Internal Dead Volume | IN→Cell ≈60 µL |
| Temperature Control | OFF, 30–55 °C (1 °C increments), 77 °C thermal cutoff |
| Interface | USB |
| Wetted Materials | SS316, PTFE, fused silica |
| Power | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), ~12 kg |
| Brand | Shodex |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI-201H |
| Detection Principle | Differential Refractive Index (dRI) |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Detector Type | Refractometer-Based Chromatographic Detector |
| Flow Cell Design | Dual-Chamber |
| Refractive Index Range | 1.00–1.75 |
| Detection Sensitivity Range | 0.25–512 µRIU |
| Baseline Drift | ≤0.2 µRIU/h (deionized water, 1 mL/min, purge off) |
| Linearity | ≥600 µRIU |
| Noise Level | ≤2.5 nRIU (deionized water, 1.5 s response time) |
| Response Time Settings | 0.1, 0.25, 0.5, 1, 1.5, 2, 3, 6 s |
| Auto-Zero Function | Full-range automatic zeroing |
| Offset Adjustment Range | ±10 µRIU |
| Offset Resolution | 50 nRIU |
| Analog Output | DC 0–1 V (2 mV/µRIU or 8 mV/µRIU selectable) |
| Flow Cell Volume | 8 µL |
| Recommended Flow Rate | 0.2–3.0 mL/min |
| Maximum Flow Rate | 10 mL/min (water) |
| Maximum Backpressure | 50 kPa |
| Dead Volume | IN→Cell ≈ 60 µL |
| Recorder Output | 0–10 mV full scale |
| External I/O Signals | READY, LEAK, ERROR (ROM/RAM/Parameter/Home Position/Overheat/Optical Balance/Intensity) |
| Temperature Control | Off, 30–55 °C (1 °C increments), thermal fuse at 77 °C |
| Interface | USB |
| Wetted Materials | ASTM F899 stainless steel 316, PTFE, fused silica quartz |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz, max. 150 VA |
| Dimensions & Weight | 260 × 400 × 150 mm (W×D×H), approx. 12 kg |
| Brand | Shodex |
|---|---|
| Origin | Japan |
| Model | RI-201H |
| Detection Principle | Differential Refractive Index (dRI) |
| Compatible Systems | HPLC & GPC Platforms |
| Detector Type | Universal Bulk Property Detector |
| Temperature Control | Built-in Thermostatic Cell Housing |
| Output Signal | Analog Voltage (0–1 V) & Digital RS-232 Interface |
| Noise Level | ≤ 2.5 × 10⁻⁹ RIU (RMS, 1 sec time constant) |
| Drift | ≤ 2 × 10⁻⁷ RIU/h (at 40 °C, stabilized) |
| Flow Cell Volume | 8 µL |
| Maximum Flow Rate | 10 mL/min |
| Solvent Compatibility | All HPLC-grade solvents except strong halogenated organics (e.g., chloroform, carbon tetrachloride) |
| Compliance | CE Marked, RoHS Compliant, Designed per IEC 61010-1 for Laboratory Equipment Safety |
| Brand | Shodex |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | RI-501, RI-502, RI-504 |
| Detection Principle | Differential Refractive Index (dRI) |
| Light Source | Deuterium Lamp |
| Temperature Control | Dual-zone thermostatic control (30–55 °C) |
| Flow Rate Range | 0.2–3.0 mL/min (RI-501/RI-504), 1–50 mL/min (RI-502) |
| Cell Volume | 8 μL (RI-501/RI-502), 2.5 μL (RI-504) |
| Noise Level | ≤2.5 nRIU (RI-501), ≤25 nRIU (RI-502), ≤5 nRIU (RI-504) |
| Drift | ≤0.2 μRIU/h (RI-501/RI-504), ≤2 μRIU/h (RI-502) |
| Response Time | Adjustable from 0.1 to 6 s |
| Output Interface | LAN, Analog (0–1 V, 0–10 mV/FS), Digital I/O (READY/LEAK/ERROR) |
| Wetted Materials | SUS316 Stainless Steel, PTFE, Fused Silica |
| Compliance | CE Marked, RoHS Compliant |
| Brand | ShoLyn |
|---|---|
| Model | ShoDetec-UV |
| Instrument Type | Thin-Layer Chromatography (TLC) Imaging System |
| Operation Mode | Manual |
| Wavelength Options | 254 nm, 365 nm |
| Light Source | High-Stability UV LED |
| Spectral Bandwidth | 12.2 nm |
| Wavelength Accuracy | ±2.7 nm |
| Wavelength Repeatability | <0.2 nm |
| Imaging Area | 50 × 70 mm |
| Camera Resolution | 5 MP fixed-focus |
| Display | 2.83-inch TFT (480 × 640) |
| Onboard Storage | 16 GB |
| Connectivity | USB-C, microSD card slot, optional Wi-Fi module |
| Power | Rechargeable 2500 mAh Li-ion battery |
| Working Distance (Depth of Field) | 5 cm |
| Rf Calculation Support | Yes |
| Brand | ShoLyn |
|---|---|
| Origin | Shanghai, China |
| Model | ShoDetec-UVE |
| Instrument Type | TLC Imaging System |
| Operation Mode | Manual |
| Wavelength Selection | Manual Dual-Band Switching |
| Wavelengths | 254 nm, 365 nm |
| Light Source | High-Intensity UV LED |
| Spectral Bandwidth | 18 nm |
| Wavelength Accuracy | ±5 nm |
| Imaging Wavelengths | 254 nm, 365 nm |
| Sample Platform | Accommodates 200 × 200 mm preparative silica gel plates and standard TLC plates (e.g., 20 × 50 mm) |
| UV Output Power | 6 W at 254 nm |
| LED Lifetime | >10,000 h |
| Built-in Rechargeable Battery | 5000 mAh |
| Viewing Area | Up to 200 × 200 mm with integrated UV-blocking filter |
| Brand | ShoLyn |
|---|---|
| Origin | Shanghai, China |
| Model | ShoDetec-UVW |
| Instrument Type | TLC Imaging System |
| Operation Mode | Manual |
| Imaging Wavelengths | 254 nm, 365 nm |
| Light Source | High-Stability UV LED (2 W per channel) |
| Spectral Bandwidth | 12.2 nm |
| Wavelength Accuracy | ±2.7 nm |
| Wavelength Repeatability | <0.2 nm |
| Sample Stage Capacity | Max. 50 × 70 mm TLC plate |
| Camera Resolution | 5 MP fixed-focus CMOS sensor |
| Display | 2.83″ TFT LCD (480 × 640) |
| Onboard Storage | 16 GB internal flash |
| Connectivity | USB-C port, microSD slot, Wi-Fi 802.11 b/g/n |
| Image Transfer Modes | USB, microSD readout, Wi-Fi upload |
| RF Calculation Support | Yes |
| Working Distance (Depth of Field) | 5 cm |
| Battery Capacity | 2500 mAh rechargeable Li-ion |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SHV-NDCS |
| Price | Upon Request |
| Sulfur Range | 0.005–100 wt% (±1% accuracy) |
| Carbon Range | 0.001–100 wt% (±1% accuracy) |
| Combustion Temperature | 1300–1500 °C |
| Carrier Gas | Oxygen or Ambient Air |
| Analysis Time | 40–300 s |
| Sample Mass | 10–200 mg |
| Detection Method | Dual-Channel NDIR Spectroscopy |
| Automation | PC-Controlled with ALC (Automatic Level Control) and Auto-Range Selection |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | AGS60 250C PRO, AGS120 250C PRO |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g / 120 g |
| Tare Range | –60 g / –120 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity | ±0.002 g |
| Accuracy Class | II |
| Resolution | 0.01% moisture |
| Moisture Repeatability | ±0.3% (2 g sample), ±0.06% (5 g sample) |
| Interface | USB, RS232C, PS2 |
| Max Drying Temperature | 250 °C |
| Drying Time Range | 1–180 s per step, up to 10 hr total |
| Drying Power | 250 W |
| Preheat Time | ~30 s |
| Pan Diameter | 90 mm |
| Chamber Dimensions | 108 × 20 mm |
| External Dimensions | 215 × 345 × 200 mm |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | ATS60, ATS120 |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g / 120 g |
| Readability | 0.001 g |
| Linearity | ±0.002 g |
| Accuracy Class | II |
| Resolution | 0.01% |
| Moisture Measurement Accuracy | ±0.1% (2 g sample), ±0.04% (5 g sample), 1% (0.02–0.5 g sample) |
| Drying Temperature Range | Up to 160 °C |
| Drying Time Range | 1–600 s (10 hr max) |
| Drying Power | 200 W |
| Preheat Time | ~60 s |
| Pan Diameter | 90 mm |
| Drying Chamber Dimensions | 108 × 20 mm |
| External Dimensions | 185 × 290 × 170 mm |
| Net Weight | 6.8 kg |
| Interfaces | USB, RS232C, PS2 |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Model | XPIN-BT |
| Active Area | 6 mm² or 13 mm² |
| Silicon Thickness | 450 µm or 625 µm |
| Beryllium Window Thickness | 8 µm or 25 µm |
| Collimator Materials | Tungsten / Cobalt / Titanium / Aluminum |
| Energy Resolution (FWHM @ Mn Kα) | ≤170 eV (6 mm²), ≤230 eV (13 mm²) |
| Peak-to-Background Ratio @ 1 keV | 3600:1 (6 mm², typical), 3000:1 (13 mm², typical) |
| Brand | Moxtek |
|---|---|
| Origin | USA |
| Model | XPIN-XT |
| Active Area | 6 mm² or 13 mm² |
| Silicon Thickness | 450 µm or 625 µm |
| Beryllium Window Thickness | 8 µm or 25 µm |
| Collimator Materials | Tungsten / Cobalt / Titanium / Aluminum |
| Energy Resolution (FWHM @ Mn Kα) | < 170 eV (6 mm²), < 230 eV (13 mm²) |
| Peak-to-Background Ratio @ 1 keV | 3600:1 (6 mm², typical), 3000:1 (13 mm², typical) |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic |
| Model | Si+SiO2+Ti+Pt (Domestically Sourced) |
| Pricing | Upon Request |
| Film Thickness | SiO₂ = 500 nm |
| Silicon Substrate | p-type, B-doped, resistivity < 0.005 Ω·cm |
| Standard Dimensions | Ø101.6 mm × 0.5 mm (4" wafers) or 10 mm × 10 mm × 0.5 mm |
| Surface Finish | Single-side polished |
| Packaging | Individual wafers in Class 100 cleanroom bags within Class 1000 cleanroom environment |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-2000SMP |
| Detector Type | Proportional Counter |
| Excitation Source | ²³⁸Pu Radioisotope |
| Energy Resolution | 15–20% (at 5.9 keV) |
| Detection Limit | 10⁻³ µg/g |
| Measurement Time | 0.5–5 min per sample |
| Operating Temperature | 0–50 °C |
| Power Consumption | ≤5 W |
| Weight | 3 kg |
| Dimensions | 30 × 20 × 13 cm |
| Elemental Range | Ca, Fe, Ti, Mn, Cu, Pb, Zn, Ni, Sn, Bi, Mo |
| Multichannel Analyzer | 512-channel |
| Sample Form | Solid (bulk or powder) |
| Compliance | CE-marked for field-deployable instrumentation |
| Software Interface | Standalone microcontroller with LCD display and onboard data storage |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SM |
| Form Factor | Benchtop/Floor-Standing |
| Instrument Type | Conventional ED-XRF |
| Application Scope | Universal (Industrial & Laboratory) |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% (matrix-dependent) |
| Energy Resolution | < 110 eV (with SDD or FAST-SDD detector) |
| Repeatability (RSD) | < 0.1% |
| Detector | Silicon Drift Detector (SDD) or FAST-SDD |
| High Voltage Supply | 0–50 kV (adjustable), 0–1 mA (adjustable) |
| Measurement Time | 100–300 s |
| Sample Mass | 3–8 g |
| Vacuum Level | ≤ 10⁻² Pa (stable for ≥30 min) |
| Dimensions | 480 × 420 × 660 mm (D×W×H) |
| Weight | 70 kg |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMP |
| Detector | Si(Li) semiconductor, Peltier-cooled |
| Energy Resolution | ≤150 eV (Mn Kα, 5.9 keV) |
| Analytical Range | 2–30 keV |
| Elements Analyzed | S to U (Z = 16–92) |
| Detection Limits | Cd/Cr/Hg/Br ≤ 1 ppm, Pb ≤ 2 ppm |
| Precision | RSD ≤ 0.08% (standard deviation) |
| Measurement Time | < 200 s |
| Power Consumption | 4 W |
| Weight | 1.75 kg |
| Battery Life | ≥ 8 h (full-load operation) |
| Operating System | Embedded Chinese GUI on integrated PDA |
| Connectivity | Bluetooth v4.0, GPS module |
| Safety Indicators | Dual-color LED (green = power on, red = X-ray emission) |
| Sample Forms | Solid blocks, powders, pressed pellets |
| Compliance | IEC 61010-1, IEC 62471 (LED safety), RoHS-compliant construction |
| Data Storage | Internal flash memory (≥ 16 GB) |
| Brand | ASPEC (Huazhi Taike) |
|---|---|
| Origin | Germany |
| Manufacturer | Plasmion GmbH |
| Model | SICRIT® SC-20X |
| Dimensions | 250 × 180 × 80 mm |
| Weight | 2.4 kg |
| Power Supply | Standard 100–240 V AC, 50/60 Hz |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | AS-18A |
| Price Range | USD 2,800 – 7,000 (FOB Shanghai) |
| Instrument Type | Gas Chromatography Liquid Autosampler |
| Sample Capacity | 18-position vial tray |
| Dual-Syringe Capability | Yes |
| Sandwich (Layered) Injection Mode | Supported |
| Communication Interface | RS-232, USB, and TTL-compatible GC trigger I/O |
| Bidirectional GC Control | GC-starts-autosampler & autosampler-starts-GC |
| User Interface | 4.3-inch capacitive touch LCD with adjustable background color and one-touch Chinese/English language toggle |
| Safety Logic | Real-time parameter range validation and input error rejection |
| Operation Modes | Single-injection, multi-injection, post-run audio alert, and auto-standby mode |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ATD-1 |
| Price Range | USD 14,000 – 42,500 (FOB) |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automatic |
| Sample Position Capacity | 1 tube |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GS-1 |
| Price Range | USD 1,400 – 2,800 (FOB Shanghai) |
| Instrument Type | Gas Chromatography Autosampler |
| Configuration Options | Single-Channel (GS-1) or Dual-Channel (GS-2) |
| Heating Option | Optional heated or ambient-temperature operation |
| Sample Loop | Customizable volume (standard range: 0.1–5 mL) |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HS-12A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Carrier Gas Compatibility | Helium, Nitrogen, Hydrogen |
| Maximum Oven Temperature | 200 °C (±0.1 °C stability) |
| Equilibration Time Range | 0–999.9 min |
| Injection Volume Precision | ±1% RSD (typical, with calibrated loop) |
| Thermal Desorption Path | Heated transfer line (up to 220 °C), inert fused-silica or SilcoNert®-treated stainless steel |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-12A Pro |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 12 positions |
| Vial Format | 20 mL standard crimp-top vials |
| System Heating | Full-path heated zone (oven, transfer line, valve, and injection port) |
| Leak Detection | Integrated automatic leak check with real-time pressure display |
| Pressure Control | Optional Electronic Pressure Control (EPC) module compatible |
| Method Storage | User-definable method library with multi-method queue execution |
| Diagnostic Features | Power-on self-test, auto-positioning carousel, real-time fault detection and on-screen alert |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 16 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Control Interface | Microprocessor-based with LCD display (English/Chinese toggle), membrane keypad, digital input |
| System Purge | Inert gas (e.g., nitrogen or argon) purge of sampling needle, loop, and transfer line after each injection |
| Sample Path Configuration | Heated, inert flow path from vial to GC inlet (no cold spots) |
| Diagnostic Features | Power-on self-test, auto-positioning sample tray, real-time status monitoring, comprehensive fault detection and on-screen alerts |
| Method Storage | Default method preloaded |
| GC Integration | Universal interface compatible with all major gas chromatographs (Agilent, Thermo Fisher, Shimadzu, PerkinElmer, etc.) |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Origin | Domestic (China) |
| Model | HS-27A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 27 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HS-42A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 42 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HS-9 |
| Price Range | USD 4,200 – 5,600 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 9 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Brand | Sida |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TD-1 |
| Price Range | USD 2,800 – 4,200 (FOB Shanghai) |
| Instrument Type | Single-Stage Thermal Desorber |
| Compatibility | GC-Compatible (Universal Interface for Domestic & Imported Gas Chromatographs) |
| Brand | SIELINS |
|---|---|
| Origin | Beijing, China |
| Model | XLZ-1090GXH |
| Analysis Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Gas Measured | NO (Nitric Oxide), with cross-sensitivity to NO₂ in multi-component gas streams |
| Measurement Range | 0–50 ppm (min) to 0–100% v/v (max, configurable) |
| Detection Limit | 0.01 ppm for O₂/N₂ (as background reference), 1 ppm for NO (trace mode) |
| Accuracy | ≤ 0.01% v/v (major component), ≤ 1 ppm (trace) |
| Repeatability | ≤ 1% FS |
| Zero Drift | ≤ ±1% FS / 48 h |
| Span Drift | ≤ ±1% FS / 48 h |
| Linearity Error | ≤ ±1% FS |
| Response Time (T₉₀) | ≤ 15 s |
| Sample Flow Rate | 0.5–3 L/min |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤ 90% RH (non-condensing) |
| Power Supply | 220 V ±10%, 50 ±0.5 Hz, 150 W |
| Analog Outputs | 4–20 mA (isolated, ≤400 Ω load) and 1–5 V (isolated, ≥250 Ω load), configurable |
| Digital Interface | RS232 (standard), protocol-compatible with SCADA/DCS systems |
| Compliance | Designed per IEC 61000-6-2 (EMC immunity) and IEC 61000-6-3 (EMC emission) |