Chemical Analysis Instruments
Filter
Showing 8881–8910 of 10659 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Chromeleon™ 7.4 |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Thermo Fisher Cindion Combustion Ion Chromatography System |
| Price | Upon Request |
| Instrument Type | Laboratory |
| Application Scope | General-Purpose |
| Flow Rate Range | 100–500 mL/min |
| Maximum Operating Pressure | 30–45 psi |
| Operating Temperature Range | 500–1200 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | DFS High-Resolution GC/MS |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| GC Configuration | Dual-Column, Dual-Trace 1310 GC Integration |
| Automation | TriPlus RSH Autosampler |
| Ion Source | Removable, Vacuum-Lock Ion Box |
| Analyzer Architecture | Double-Focusing Magnetic Sector with Ring-shaped Electrostatic Analyzer (ESA) |
| Calibration | Field-Based Mass Calibration Independent of Scan Speed, Ion Polarity, and Ionization Mode |
| Detection | Dual-Stage Electron Multiplier with Pneumatic Valve Vacuum Lock |
| Regulatory Compliance | Designed for EPA Method 1613/8270, EU Directive 2006/122/EC, WHO IPCS Dioxin Guidelines, USP <1225>, FDA 21 CFR Part 11 Audit Trail Support |
| Brand | Thermo Fisher |
|---|---|
| Model | DFS |
| Type | Double-Focusing Magnetic Sector GC-MS |
| Detector | Dual-Channel Electron Multiplier with Convertor Electrode |
| Resolution | Up to 100,000 (10% Valley) |
| Mass Range | 10–2000 m/z |
| Ion Source | Removable, Modular EI/CI Source |
| Vacuum System | Pneumatic Valve Lock for Ion Box Exchange Without Venting |
| GC Compatibility | Dual Trace 1310 GCs on Single Ion Source |
| Automation | TriPlus RSH Autosampler with Dual-Column Sequential Injection |
| Calibration | Field-Based, Mode-Independent Mass Calibration |
| Software | Thermo Xcalibur with DFS-Specific Acquisition & Quantitation Modules |
| Compliance | Designed for EPA Method 1613/8270, EU 2017/625, ISO 18073, and GLP/GMP environments requiring 21 CFR Part 11 audit trails |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | DFS+ |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Measurement Precision | 0.1‰ (delta notation, per mil) |
| Measured Isotopes | δ¹³C, δ¹⁵N, δ¹⁸O, δ²H, δ³⁴S, and noble gas isotopes (e.g., ³⁶Ar, ³⁸Ar, ⁴⁰Ar, ⁸⁴Kr, ¹³²Xe) |
| Mass Range | 2–500 u |
| Mass Resolution (M/ΔM) | 110,000 (at 10% valley definition) |
| Sensitivity | ≥1000 V per picomole of CO₂ (for δ¹³C analysis under standard dual-inlet configuration) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate Range | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-AP |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 1152 positions (microtiter plate) / 81 vials (10 mL) |
| Injection Cycle Time | <30 s for 5 µL injection |
| Precision | RSD <0.3% |
| Fluidic Path | Full PEEK™ construction |
| Needle Design | Moving-needle architecture |
| Temperature Control | 4–60 °C sample tray cooling |
| Integrated Pre-injection Analysis | Conductivity & pH measurement |
| Automation Capabilities | Automated internal standard addition, on-line dilution, pre-column derivatization, matrix removal, analyte preconcentration, fraction collection, re-injection, and sample ejection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-DV |
| Instrument Category | Multifunctional Autosampler |
| Fluidic Path Material | PEEK™ |
| Compatible Systems | All Dionex ICS Ion Chromatography Systems |
| Sample Vial Capacity | 5.0 mL and 0.5 mL polymer vials |
| Valve Options | Optional 6-port or 10-port switching valves |
| Software Control | Thermo Scientific Chromeleon CDS (v7.3 or later) |
| Audit Trail & Electronic Signatures | Compliant with 21 CFR Part 11 |
| Dual-IC System Operation | Supported |
| Sample Overlap Injection | Enabled |
| Filtration Option | Available with filter cap accessory |
| Detection Limit Enhancement | Via automated on-line preconcentration and matrix elimination |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-HV |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 250 mL |
| Syringe/Pump Options | Syringe, Peristaltic, or Piston Pump |
| Rack Compatibility | 21-position (50 mL vials, 30 mm O.D.), 24-position (26 mL vials, 24 mm O.D.), 40-position (15 mL vials, 20 mm O.D.), 60-position (10 mL vials, 16 mm O.D.), or 21-position (60/40 mL ASE™ Collection Vials) |
| Fluid Path Material | All-PEEK™ |
| Loading Mode | Programmable “push” or “pull” |
| Arm Motion | High-speed, high-precision robotic positioning |
| Footprint | Compact benchtop design |
| Optional Integration | Dionex AutoPrep™ system, RFIC™-ESP platform, trace analysis cover |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX-120 |
| Instrument Type | Laboratory |
| Pump Pressure Rating | 27.5 MPa (4000 psi) |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.1–3.0 mL/min |
| Max Operating Pressure | 17 MPa (3500 psi) |
| Operating Temperature Range | 10–40 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC-manufactured) |
| Model | Dionex Easion Ion Chromatography System |
| Instrument Type | Laboratory Benchtop IC System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0.00–5.00 mL/min (single-pump-head design) |
| Maximum Operating Pressure | 10 MPa |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-1100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), adjustable per eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-1600 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Eluent Generation Compatibility | RFC-30 Electrolytic Eluent Generator |
| Suppressor Type | AutoSuppression™ Electrolytic Micro-Membrane Suppressor |
| Software Platform | Chromeleon™ 7.3 or later |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ICS-2100 |
| Instrument Type | Laboratory Benchtop IC System |
| Pump Pressure Rating | Up to 35 MPa (5,000 psi) |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Range | 0.1–3.0 mL/min |
| Operating Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Column Compatibility | 2 mm and 4 mm internal diameter columns |
| Detector | Suppressed Conductivity Detection (with SRS-300 continuous regeneration micro-membrane suppressor) |
| Data Acquisition Interface | USB 2.0 |
| Software Platform | Chromeleon 6.8 Chromatography Data System (CDS) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-4000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10°C–40°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-4000 CD |
| Instrument Category | Laboratory Benchtop Ion Chromatograph Detector |
| Detection Principle | Suppressed/Unsuppressed Conductivity Detection |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume | 0.02 µL (Capillary Mode) |
| Temperature Control | Independent, Microprocessor-Regulated Detector Thermostat |
| Interface | Plug-and-Play Auto-Recognition via Chromeleon™ CDS |
| Mounting | Tool-Free Snap-In Mechanism |
| Compatible Configurations | Series or Parallel Dual-Detector Setup |
| Flow Path Options | Capillary, Analytical (Standard-Bore and Microbore) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ CD |
| Application Environment | Laboratory-Based Ion Chromatography System |
| Configuration Options | Capillary and Analytical (Standard-Bore & Microbore) Flow Paths |
| Detector Architecture | Digital Signal Processing (DSP)-Enabled, Thermally Stabilized Conductivity Detection Module |
| Dynamic Range | 0–15,000 µS/cm |
| Cell Volume (Capillary Mode) | 0.02 µL |
| Installation Interface | Tool-Free Snap-In Mounting with Auto-Detection via Chromeleon™ CDS |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-5000+ ED |
| Application | Laboratory-Based Ion Chromatography |
| Detection Principle | Pulsed Amperometric Detection (PAD), DC Amperometry, Integrated Amperometry, and Cyclic Voltammetry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-600 |
| Instrument Type | Laboratory |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.1°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ICS-6000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–22.4 mL/min |
| Eluent Flow Rate Range | 0.001–22.4 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 10°C–70°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–200 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-900 Starter Line IC System |
| Pump Pressure Rating | 6000 psi |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-VWD |
| Wavelength Range | 190–900 nm |
| Data Acquisition Rate | Up to 100 Hz |
| Light Sources | Deuterium Lamp + Tungsten Lamp |
| Software Control | Thermo Scientific Dionex Chromeleon Chromatography Data System (CDS) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Dionex Inuvion |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0–5 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | 10–60 °C (±0.5 °C) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | Thermo Fisher Dionex Inuvion Ion Chromatography System |
| Price | Upon Request |
| Pump Pressure Range | 0–5000 psi |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic |
| Model | Inuvion Ion Chromatography System (Domestically Manufactured) |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Dionex Inuvion Ion Chromatography System |
| Pricing | Available Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | DXR3xi |
| Instrument Category | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–9000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 350 nm |
| Excitation Wavelength | 455 nm (optional lasers available) |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | ECtestr 11+ |
| Conductivity Range | 0–200.0 µS/cm, 0–2000 µS/cm, 0–20.00 mS/cm |
| Resolution | 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm |
| Accuracy | ±1% of full scale |
| Calibration Points | 3-point (auto/manual) |
| Temperature Range | 0–50.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| TDS Conversion Factor | Adjustable (0.40–1.00) |
| Sensor Material | SS316 stainless steel with Valox protective housing |
| Ingress Protection | IP67 |
| Power | Replaceable batteries |
| Battery Status Retention | Calibration settings retained after battery replacement |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Benchtop Conductivity Meter |
| Model | Eutech CON700 |
| Measurement Parameters | Conductivity, TDS, Temperature |
| Conductivity Range | 0 μS/cm to 200.0 mS/cm |
| TDS Range | 0–100 ppt (TDS factor 0.5) |
| Temperature Range | 0.0–100.0 °C |
| Accuracy | ±1% of full scale |
| Resolution | 0.01 / 0.1 / 1 μS/cm |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Points | Up to 5-point conductivity/TDS calibration |
| Data Storage | 100 measurement records |
| Electrode Compatibility | 2-cell or 4-cell conductivity cells (K = 0.1, 1.0, 10.0 cm⁻¹) |
| Auto-Endpoint Detection | Yes |
| Temperature Compensation | Automatic or manual (linear, 0.00–10.00%/°C) |
| Reference Temperature | 15.0–30.0 °C |
| Display | Dual-line LCD (5.6 × 7.5 cm), large-font numeric readout |
| Power Supply | 9 V DC regulated adapter (100–240 VAC, SMPS) |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight | 650 g (instrument only) |
