| Brand | Teledyne Judson |
|---|---|
| Type | Mercury Cadmium Telluride (HgCdTe) Detector |
| Detector Architecture | Photovoltaic (PV) and Photoconductive (PC) |
| Spectral Range (PV) | 0.5–5.5 µm (cutoff options: 2.8 µm, 5.0 µm, 5.5 µm) |
| Spectral Range (PC) | 2–26 µm (cutoff options: 5 µm, 12 µm, 26 µm) |
| Cooling Requirement | Liquid nitrogen (77 K) or thermoelectric (TE) stabilization |
| Active Area Options | 0.1 × 0.1 mm to 2 × 2 mm |
| ROIC Compatibility | Available with integrated preamplifiers and hybridized readout ICs for focal plane array (FPA) integration |
| Compliance | RoHS-compliant packaging |
| Brand | Teledyne Judson |
|---|---|
| Model | PbS |
| Spectral Range | 1.0–3.5 µm |
| Detector Type | Photoconductive |
| Cooling Options | Thermoelectric (TEC) Stages Available (Standard, Enhanced Stability, Low-Noise Configurations) |
| Origin | Beijing, China |
| Distribution Channel | Authorized Distributor |
| Compliance | RoHS Compliant, CE Marked for Instrument Integration |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Model | CS844-LM |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.0001–6.0 wt% |
| Sulfur Range | 0.0001–3.5 wt% |
| Sensitivity | 0.000001 wt% |
| Precision | ±1 ppm |
| Analysis Time | 20–40 s |
| Furnace Output Power | 3.5 kW |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DH603-G4 |
| Instrument Type | Diffusion Hydrogen Analyzer |
| Analysis Range | 0.05–3000 mL/100g |
| Analytical Precision | 0.001 mL/100g |
| Sensitivity | ±1% |
| Analysis Time | 3–10 min |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EA3500 |
| Pricing | Upon Request |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated |
| Model | EA3507 |
| Compliance | ASTM D515, ISO 14891, AOAC 992.15, EN ISO 16634-1:2021 |
| Detection Principle | Thermal Conductivity Detection (TCD) of N₂ after catalytic combustion and reduction |
| Sample Form | Solid or liquid |
| Typical Analysis Time | < 5 min per sample |
| Nitrogen Range | 0.01–100 mg N |
| Precision | RSD ≤ 0.5% (n = 10, 10 mg N standard) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II AA |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Methods 245.1, 245.5, 245.6, 7470A, 7471B |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Model | Hydra II C |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance | EPA Method 7473, SN/T 3511–2013, HJ 910–2017, HJ 917–2017, HJ 923–2017, Cosmetics Safety Technical Specifications (2015 Edition) |
| Sample Introduction | Direct Solid/Liquid Injection Without Prior Digestion |
| Optical Design | Dual-Beam, Dual-Cell Configuration with Real-Time Baseline Monitoring |
| Moisture Management | Integrated Desiccant Drying Tube |
| Operational Readiness | Ambient-Temperature Operation, No Preheating Required |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Beijing, China |
| Model | ONH836-G8 |
| Analysis Range | O: 0.01 ppm–5 wt% |
| N | 0.01 ppm–3 wt% |
| H | 0.01 ppm–0.3 wt% |
| Analytical Precision | O/N: ±0.25 ppm |
| H | ±0.5 ppm |
| Detection Limit | 0.001 ppm |
| Analysis Time | 90 s |
| Pulse Furnace Power | 10 kW |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy DC Arc |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Repeatability | ≤1.5% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm (at 200 nm) |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | 0.1 ppm |
| Precision (RSD) | ≤1.5% |
| Stability (Drift) | ≤2% |
| Wavelength Range | 175–900 nm |
| Optical Resolution | ≤0.005 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy Plus |
| Instrument Type | Full-Spectrum Direct-Reading ICP Optical Emission Spectrometer |
| Detection Limit (Zn @ 213.856 nm) | < 0.1 µg/L |
| Precision (RSD) | ≤ 0.5% |
| Long-Term Stability (RSD, 4h) | ≤ 1.0% |
| Wavelength Range | 130–1100 nm |
| Optical Resolution | 0.005 nm @ 200 nm |
| Detector | Custom 28 × 28 mm CMOS sensor with 3.38 million effective pixels |
| Readout Speed | >10× faster than conventional CID/CCD detectors |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | USA |
| Model | Prodigy7 |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Detection Limit (Zn at 213.856 nm) | <0.1 µg/L |
| Precision (RSD) | ≤1.0% |
| Stability (RSD over 4 hours) | ≤1.0% |
| Wavelength Range | 165–1100 nm |
| Optical Resolution | ≤0.007 nm @ 200 nm |
| Brand | Teledyne Leeman Labs |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Full-Spectrum Simultaneous Readout |
| Detection Limit (Ca at 396.847 nm) | 0.155 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (2-hr drift) | ≤1.0% |
| Optical Resolution | 0.005 nm |
| RF Generator Cooling | Air-Cooled |
| Plasma Torch Assembly | Ceramic RF Load Coil |
| Optical System | Echelle Grating with ICCD Detector |
| Compliance | ASTM D1976, ISO 11885, USP <233>, EPA Methods 200.7 & 6010E |
| Brand | Teledyne Photon Machines |
|---|---|
| Origin | Imported |
| Model | LSX-213 G2+ |
| Laser Wavelength | 213 nm (5th harmonic of Nd:YAG) |
| Pulse Energy | >4 mJ |
| Pulse Width | <5 ns |
| Ablation Spot Size Range | 4–200 µm (14 standard apertures) |
| Microscope Magnification | 2.6×–32.5× |
| Optical Resolution | <2 µm |
| XY Stage Step Resolution | 0.16 µm |
| Laser Type | Q-switched, solid-state Nd:YAG |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | HRS-300, HRS-500 |
| Focal Length | 300 mm (HRS-300), 500 mm (HRS-500) |
| f-number | f/3.9 (HRS-300), f/6.5 (HRS-500) |
| Linear Dispersion | 2.38 nm/mm (HRS-300), 1.52 nm/mm (HRS-500) |
| PMT Resolution (1200 g/mm grating, 435.8 nm, 10 µm slit) | 0.09 nm (HRS-300), 0.05 nm (HRS-500) |
| CCD Resolution (1200 g/mm grating, 435.8 nm, 20 µm pixel & slit) | 0.10 nm (HRS-300), 0.07 nm (HRS-500) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tekmar 3100 |
| Instrument Type | Water & Soil Dual-Mode Purge and Trap System |
| Sample Tray Capacity | 84 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | 180–300 °C |
| Purge Heater Temperature Range | Ambient to 90 °C |
| Sample Vial Chilling Temperature | 4–10 °C |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Integrated Online LIBS System |
| Price Range | USD 210,000 – 280,000 |
| Instrument Type | Online |
| Integration Level | Fully Integrated |
| Core Components | Q-switched Nd:YAG Laser Source, Echelle or Czerny–Turner Spectrometer, ICCD Detector, Synchronization Controller, LIBS-Specific Acquisition & Analysis Software |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | OLED/QLED Device Lifetime Testing System |
| Price Range | USD 14,000 – 28,000 |
| Channel Capacity | 32 / 64 / 128 (scalable to 512 channels) |
| Operating Modes | Constant Current, Constant Voltage, Constant Luminance (user-selectable) |
| Current Output Range | 0.03 µA – 100 mA (accuracy ±1% of reading) |
| Voltage Output Range | 1.0 – 20 V (accuracy <±1%) |
| Device Architecture Support | Bottom-emission, top-emission, inverted, and standard stack configurations (customizable per device architecture) |
| Substrate Compatibility | Standard 5 cm × 5 cm |
| Temperature Range | RT+10°C to 100°C (standard) |
| Environmental Options | Inert atmosphere testing (N₂/Ar), glovebox-integrated operation, UPS-backed power supply |
| Software Platform | LabVIEW-based control and data acquisition with real-time logging, timestamped event tracking, and export-ready CSV/Excel output |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RTS-B |
| Price | USD 70,000 (approx.) |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 60–5000 cm⁻¹ |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Excitation Lasers | Standard 532 nm |
| Microscope | Olympus BX53 or Leica DM2700 upright research-grade microscope |
| Gratings | 150, 600, 1800 grooves/mm (blaze wavelength selectable) |
| Detector | Deep-cooled, infrared-enhanced, low-noise scientific CCD |
| Confocal Mode | Slit-CCD coupled high-throughput confocal architecture |
| Optical Path | Horizontal, rigid monolithic design |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-EX |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1100 nm |
| Spectral Resolution | <0.8 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-HiR |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 200–1100 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Spatial Resolution | Lateral <1 µm, Axial <2 µm |
| Minimum Wavenumber | 0 cm⁻¹ |
| Spectral Reproducibility | ±0.2 cm⁻¹ |
| Brand | TEO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | RTS-mini |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.1 cm⁻¹ |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TES-300 |
| Optical Design | Single-Beam |
| Detector | CCD Array |
| Wavelength Range | 104–1040 nm |
| Wavelength Selection | Manual Drive |
| Spectral Bandwidth | 10 nm |
| Wavelength Accuracy | ±0.01 nm |
| Stray Light | < 0.01% T |
| Grating | 1200 l/mm, Al/MgF₂ coated (optimized 100–300 nm), user-replaceable |
| Input Focal Length | 200 mm |
| Output Focal Length | 187.9 mm |
| F/# | 4.2 |
| Deviation Angle | 64° |
| Optimal Operational Range | 115–300 nm |
| Full Usable Range | 25–1000 nm (gold coating recommended below 100 nm) |
| Slit | Adjustable entrance and exit slits on dual-arm configuration |
| Grating Drive | Encoded Angular Encoder Grating Drive (AEGD) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | TESC-5133 |
| Temperature Control Range | −42 °C to 90 °C |
| Compliance | ASTM D5133, ASTM D7110, SH/T 0732, GB/T 11121 |
| Cooling Method | Solid-State Peltier |
| Sample Chamber | Sealed, Thermally Isolated Enclosure |
| Automation Level | Fully Automated, Unattended Operation |
| Footprint | Compact Benchtop Design |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | FIB-SEM-TOF-SIMS |
| Price Range | USD 1.3M–2.6M (FOB Europe) |
| Mass Analyzer Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | 1–2500 Da |
| Mass Resolution (M/ΔM) | >800 (at 10% valley definition) |
| Brand | TESCAN |
|---|---|
| Origin | Czech Republic |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Nanospace SIMS |
| Instrument Type | Orthogonal Time-of-Flight (OTOF) SIMS |
| Mass Range | 1–1,500 Da |
| Mass Resolution | >9,500 (FWHM at m/z 100) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2051 |
| Instrument Type | Portable |
| Parameter Types | pH & Temperature |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration | 1-, 2-, or 3-point with NIST-traceable buffers |
| Electrolyte | Replaceable gel electrolyte |
| Probe Tip Diameter | 11 mm |
| Probe Shaft Length | 25 mm |
| Display | Dual-line backlit LCD |
| Housing Material | ABS |
| Protection Rating | IP65 |
| Weight | 135 g |
| Dimensions (L×W×H) | 145 × 38 × 167 mm |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–+70 °C |
| Battery | LR44 button cell (≈80 h operation) |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2061 |
| Instrument Type | Pen-style pH Meter |
| Parameters Measured | pH and Temperature |
| pH Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0–60 °C (short-term up to 80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Standard | NIST-traceable buffer solutions |
| IP Rating (with TopSafe protective sleeve) | IP68 |
| Weight | 69 g |
| Dimensions (L×W×H) | 197 × 33 × 20 mm (including probe and TopSafe) |
| Display | 2-line LCD with backlight |
| Power Supply | 1 × CR2032 battery (≈80 h operating time) |
| Housing Material | ABS |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–+70 °C |
| Compliance | CE 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 2061 |
| Instrument Type | Pen-style |
| Parameter Types | Dual-parameter (pH + temperature) |
| pH Measurement Range | 0–14 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.02 pH |
| Temperature Range (NTC) | 0 to +60 °C (short-term up to +80 °C for ≤5 min) |
| Temperature Accuracy | ±0.4 °C |
| Temperature Resolution | 0.1 °C |
| Calibration Solution Standard | NIST-traceable |
| Protection Rating (with TopSafe sleeve) | IP68 |
| Weight | 69 g |
| Dimensions (L×W×H) | 197 × 33 × 20 mm (with probe and TopSafe) |
| Display | Backlit 2-line LCD |
| Battery | CR2032 (≈80 h operation) |
| Operating Temperature | 0 to +60 °C |
| Storage Temperature | −20 to +70 °C |
| Housing Material | ABS |
| Compliance | CE 2014/30/EU |