Chemical Analysis Instruments
Filter
Showing 61–90 of 4187 results
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Model | ABN-XRF-001 |
| Instrument Type | Benchtop |
| Scanning Mode | 2D Mapping |
| Scan Speed | ≤1 frame/sec |
| Detector | 2048 × 2048 CMOS |
| Effective Detection Area | 4.6 mm × 4.6 mm |
| Spatial Resolution | ≤2 µm |
| Quantitative Accuracy | ±0.5% relative error (for major/majority elements) |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Sample Stage Max Size | 30 mm × 30 mm |
| Operating Temperature Range | −196 °C to 100 °C |
| Power Consumption | ≤100 W |
| Safety Compliance | IEC 61010-1, IEC 62471 (UV/X-ray emission limits) |
| Brand | Aboni |
|---|---|
| Origin | Germany |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Sample Form | Solids, Powders, Films |
| Measuring Principle | Hydride-Generation Gas Evolution (CaH₂ Reaction) |
| Absolute Range | 0.2–30 mg H₂O |
| Relative Range | 0.0005–5 % w/w |
| Reproducibility | ±0.1 mg H₂O (at 1 mg), ±0.3 mg H₂O (at 20 mg) |
| Sample Weight | 0.01–50 g (up to 100 g, density-dependent) |
| Sample Volume | ~50 cm³ |
| Test Temperature | 50–210 °C (1 °C increments) |
| Ambient Air Monitoring | Temp (0.1 °C), RH (0.1 %), Pressure (1 mbar) |
| Reagent | Calcium Hydride (CaH₂) powder (~0.1 g/test) |
| Power Supply | 100/115/230 VAC |
| Dimensions | 285 × 170 × 250 mm (H×W×D) |
| Weight | 4.6 kg |
| Interface | Bidirectional RS-232 |
| PC Requirements | Windows® 98/ME/2000/NT/XP with RS-232 or USB (via adapter) |
| Compliance | ISO 15512 |
| Brand | ABSCI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5500 |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose |
| Mass Range | m/z 5–1250 |
| MS/MS Sensitivity (ESI) | 50 fg, S/N > 500:1 |
| Resolution | 0.7 amu |
| Mass Accuracy | ±0.1 Da/24 h |
| Polarity Switching Time | ≤50 ms |
| Scan Speed | ≥12,000 amu/s |
| LC Pressure Capability | 15,000 psi |
| Column Temperature Range | 5–65 °C |
| Operating Pressure Range | 1200 psi |
| Brand | ABSCI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Triple Quadrupole |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | 100.1 fg on-column (for reserpine, SRM) |
| Resolution | 0.5 Da (unit resolution at peak width at half height) |
| Mass Accuracy | ±0.1 Da (external calibration) |
| Source Pressure | 1200 Torr (ESI/APCI source operating pressure) |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Model | HPMS-TQ |
| Application Scope | General-purpose LC-MS/MS analysis |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Fully integrated acquisition and quantitation platform with audit trail capability |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Tandem Mass Spectrometer (QqQ MS/MS) |
| Configuration | Integrated Online SPE–UHPLC–MS/MS Platform |
| Application Scope | Targeted Quantitative Analysis in Complex Matrices |
| Regulatory Alignment | Designed for compliance with ISO/IEC 17025, USP <621>, and EPA Method 1694 workflows |
| Software Compatibility | Vendor-neutral front-end interface supporting third-party mass spectrometers (e.g., Waters Xevo TQ-S, Thermo Scientific TSQ Altis, Sciex QTRAP 6500+) |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PAH Analysis System |
| Instrument Type | Dedicated High-Performance Liquid Chromatography (HPLC) System |
| Application Scope | Specialized for Polycyclic Aromatic Hydrocarbons (PAHs) in Environmental Matrices |
| Configuration | Online Solid-Phase Extraction (SPE) coupled with HPLC and Fluorescence Detection (FLD) |
| Optional Upgrade Path | Online SPE–LC–MS/MS Interface Module |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S3000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S6000 Comprehensive 2D-LC System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose complex matrix analysis |
| Regulatory Compliance | Supports GB 5009.296–2023 and GB 5009.82–2016 for fat-soluble vitamins |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | S6000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 45 MPa / 62 MPa |
| Injection Volume | 100 µL (expandable to 1000 µL) |
| Data Acquisition Frequency | 160 Hz |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S6000 Online SPE–2D-LC System |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform for complex matrix samples |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | S6000PLUS |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Pump Configuration | Binary High-Pressure Gradient or Quaternary Low-Pressure Gradient Optional |
| Max Operating Pressure | 70 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Injection Volume | 0.1–30 µL (expandable to 100 µL) |
| Autosampler Capacity | 120 × 2 mL vials or 96-well microplate |
| Autosampler Temperature Control | 1–45 °C (Peltier-based, ±0.3 °C stability) |
| Column Oven Temperature Range | 1–90 °C (Peltier heating/cooling, ±0.1 °C uniformity) |
| Detector Options | UV, DAD (1024-pixel diode array), FLR, RI, ELS |
| DAD Specifications | Built-in Hg lamp wavelength calibration, 160 Hz acquisition rate, multi-channel reference background fitting, user-defined reference wavelengths per channel |
| Sample Carryover | <0.003% |
| Column Compatibility | Up to 300 mm length, ≥2.5 µm particle size columns |
| Integrated Column Switching Valve | Optional internal valve with up to 6-position configuration |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Maximum Operating Pressure | 150 MPa |
| Sample Capacity | 162 × 2 mL vials + 4 × 4 mL vials |
| Column Oven Temperature Range | 1.0–90.0 °C (0.1 °C resolution) |
| UV-Vis Detection Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Detector Options | UV-Vis, Diode Array (DAD), Fluorescence (FLR), Refractive Index (RI), Evaporative Light Scattering (ELS) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Instrument Type | Liquid Chromatography Column Switching Module |
| Fluidic Path Materials | SS316L, PTFE, ETFE, PEEK |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi AGS-36 |
| Valve System | 6-port rotary valve |
| Temperature Control Range (Valve, Quantitative Loop & Transfer Line) | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Volume | 1.0 mL (customizable from 50 µL to 5 mL via quantitative loop) |
| Sample Positions | 36 (expandable to 90 positions via modular 36+18N configuration) |
| Sampling Time | 0–99.9 s |
| Loop Equilibration Time | 0–99.9 s |
| Injection Channels | 1 (customizable) |
| Repeatability | <0.5% RSD (at 100 ppm total hydrocarbons or methane) |
| Power Consumption | 300 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 55 × 42 × 58 cm |
| Weight | ~25 kg |
| Sampling Pump | Corrosion-resistant diaphragm pump |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Software | PC-based control with bilingual (English/Chinese) GUI, full audit trail, GLP-compliant event logging |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi AGS-72 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Positions | 72 |
| Max Repeated Injections | Unlimited |
| Min Injection Volume | 0.5 mL (customizable) |
| Quantitative Loop Volume | 1 mL (customizable) |
| Positioning Accuracy | <0.3 mm |
| Motion Control | Precise Valve Switching |
| Needle Cleaning Method | Reverse Purge |
| Reproducibility | <1.5% RSD (at 100 ppm methane) |
| Power Consumption | 300 W |
| Input Voltage | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 55 × 42 × 58 cm |
| Weight | ~25 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi AGS-H25 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Capacity | 25 positions |
| Minimum Injection Volume | 0.5 mL (customizable) |
| Quantitative Loop Volume | 1 mL (customizable) |
| Positioning Accuracy | <0.3 mm |
| Motion Control | Precision valve-switching actuation |
| Needle Cleaning Method | Reverse purge |
| Repeated Injection Capability | Unlimited |
| Valve & Tubing Temperature Range | Ambient to 220 °C ±0.1 °C |
| Sample Port Temperature Range | Ambient to 150 °C ±1 °C |
| Reproducibility | <1.5% RSD (at 100 ppm methane) |
| Power Consumption | 1500 W |
| Electrical Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 725 × 500 × 680 mm |
| Weight | ~55 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi ATD I-26 |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, 6-port valve, transfer line) |
| Desorption Pressure/Flow Range | 0–300 mL/min (continuously adjustable) |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 26 positions |
| Sorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 605 × 350 × 520 mm |
| Weight | ~30 kg |
| Desorption Recovery Efficiency | >98% |
| Flow Display | Digital electronic mass flow indication |
| Control Interface | Integrated 7-inch capacitive touchscreen |
| Method Storage | Up to 10 user-editable and recallable methods |
| Automation | Fully automated unattended operation with GC and data system synchronization |
| Leak Detection | Built-in automatic leak check routine |
| Fault Monitoring | Real-time thermal and pneumatic fault diagnostics |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD I-26D |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, six-port valve, transfer line) |
| Desorption Flow Rate | 0–300 mL/min, continuously adjustable |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 52 positions (26 × 2 dual-channel configuration) |
| Trap Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 600 W |
| Dimensions (W×D×H) | 810 × 450 × 510 mm |
| Weight | ~35 kg |
| Desorption Recovery Rate | >98% |
| Valve Type | Heated six-port rotary valve |
| Interface | Touchscreen HMI, event-triggered GC start, 10 programmable methods |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Acrichi ATD I-50 |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 420 °C |
| Temperature Control Accuracy | ±1 °C (desorption furnace, 6-port valve, transfer line) |
| Desorption Pressure/Flow Range | 0–300 mL/min (continuously adjustable) |
| Desorption/Injection/Activation Time | 0–99 min |
| Sample Capacity | 50 positions |
| Sorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (1/4″ × 3.5″) |
| Power Consumption | 500 W |
| Dimensions (W×D×H) | 605 × 350 × 520 mm |
| Weight | ~30 kg |
| Desorption Recovery Rate | >98% |
| Interface | Touchscreen HMI with event-triggered GC synchronization |
| Method Storage | 10 user-editable, recallable methods |
| Leak Detection | Integrated real-time pressure decay monitoring |
| Fault Diagnostics | Auto-alert with on-screen status code and operational log |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD II-26 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 400 °C, Control Accuracy: ±1 °C |
| Secondary Desorption Temperature Range | Ambient to 450 °C, Heating Rate: >4000 °C/min |
| Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cryo-Focusing Trap Temperature Range | −40 °C |
| Temperature Control Precision (Cryo Trap) | <±0.1 °C |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 26 tubes |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | ATD II-26D |
| Instrument Type | Secondary Thermal Desorber |
| Desorption Temperature Range | Ambient to 450 °C, Heating Rate >3600 °C/min |
| Cold Trap Temperature Range | −40 °C to Ambient (Electronic Cooling) |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 52 Positions (26 × 2 Dual Channels) |
| Valve & Transfer Line Temp Control | Ambient to 220 °C (±1 °C) |
| Focusing Tube Temp Control | Ambient to 450 °C, Heating Rate >3000 °C/min |
| Carrier Gas Flow Control | 0–100 mL/min (Backflush), 100 mL/min (Sample Preparation) |
| Timing Resolution | 0.1 min (0.0–999.9 min) |
| Adsorbent Tube Dimensions | 6.35 mm OD × 88.9 mm L (¼″ × 3.5″) |
| Power | 900 W, 220 V, 50 Hz |
| Dimensions | 810 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | Acrichi ATD II-50 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 450 °C |
| Heating Rate | >6000 °C/min |
| Six-Port Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Cold Trap Temperature Range | −40 °C to Ambient (Electronic Cooling) |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% |
| Sample Capacity | 50 positions |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | DK802A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260°C |
| Valve & Transfer Line Temperature Range | Ambient to 220°C |
| Temperature Control Accuracy | ±0.1°C |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Loop Volume | 1 mL (customizable) |
| RSD | <1.5% (for 200 ppm ethanol in water) |
| Power | 500 W |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Dimensions | 50 × 32 × 60 cm |
| Weight | ~30 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Acrichi DK802T |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Quantitative Loop Volume | 1 mL (customizable) |
| Precision (RSD) | <1.5% (for 200 ppm ethanol in water) |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | DK803A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260°C |
| Valve & Transfer Line Temperature Range | Ambient to 220°C |
| Temperature Control Accuracy | ±0.1°C |
| Sample Vial Capacity | 30 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Quantitative Loop Volume | 1 mL (customizable) |
| RSD | <1.5% (for 200 ppm ethanol in water) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 50 × 45 × 60 cm |
| Weight | ~40 kg |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DK808A |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260 °C |
| Valve Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Vial Capacity | 112 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Quantitative Loop Volume | 1 mL |
| RSD (Repeatability) | <1.5% (200 ppm ethanol in water) |
| Power Consumption | 400 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Dimensions (W×D×H) | 60 × 68 × 68 cm |
| Weight | ~55 kg |
| Warranty | 12 months (parts, electronics, firmware |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | PTC-106 |
| Sample Capacity | 106 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | −40 °C to 450 °C |
| Purge Heater Temperature Range | Ambient to 100 °C |
| Vial Cooling Temperature Range | 4 °C to Ambient |
| Instrument Type | Water-and-Soil Dual-Mode Purge and Trap Device |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi PTC-56 |
| Sample Capacity | 56 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | Ambient to 450 °C |
| Purge Sample Heating Range | Ambient to 100 °C |
| Sample Vial Cooling Range | −40 °C to Ambient |
| Purge Flow Rate | 10–150 mL/min (continuously adjustable) |
| Cold Trap Temperature Range | −40 °C to Ambient (electronic cooling) |
| Focusing Trap Ramp Rate | >4800 °C/min |
| Dimensions | 650 × 880 × 530 mm |
| Weight | ~40 kg |
| Power | 220 V, 50 Hz, 800 W |
| Brand | Acrichi |
|---|---|
| Origin | Beijing, China |
| Model | Acrichi PTC-86 |
| Sample Capacity | 86 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | Ambient to 450 °C |
| Purge Sample Heating Range | Ambient to 100 °C |
| Sample Vial Cooling Range | −40 °C to Ambient |
| Purge Flow Rate | 5–500 mL/min (continuously adjustable) |
| Valve & Transfer Line Temp Control | Ambient to 220 °C (±1 °C) |
| Cold Trap Temp Control | −40 °C to Ambient (electronic cooling, ±1 °C) |
| Water Removal Trap Temp Range | Ambient to 400 °C |
| Distilled Water Rinse Temp Range | Ambient to 90 °C (±1 °C) |
| Solid Sample Vial Temp Range | Ambient to 100 °C (±1 °C) |
| Ramp Rate (Trap) | >4800 °C/min |
| Power | 800 W |
| Dimensions | 650 × 880 × 530 mm |
| Weight | ~40 kg |