Chemical Analysis Instruments
Filter
Showing 9631–9660 of 10552 results
| Brand | ULVAC-PHI |
|---|---|
| Origin | Japan |
| Model | PHI oTOF3+ |
| Type | TOF-SIMS Instrument with TRIFT Analyzer |
| Ion Sources | Liquid Metal Ion Gun (Ga⁺), Optional Ar-GCIB, Cs⁺, O₂⁺ |
| Spatial Resolution | <50 nm (high-resolution mode), <500 nm (high-mass-resolving mode) |
| Automation | Fully Automated Sample Transfer & Unattended Multi-Sample Analysis |
| Charge Neutralization | Dual-Beam Electron/Ar⁺ Neutralization System |
| Optional Features | Parallel Imaging MS/MS, FIB Cross-Sectioning, Cryo-Stage, Detachable Glovebox Integration |
| Compliance | Designed for GLP/GMP environments |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UM-1PF, UM-1PFC |
| Fine Adjustment Range (UM-1PF) | 20 mm (X-axis) |
| Fine Adjustment Range (UM-1PFC) | 6 mm (X-axis) |
| Coarse Adjustment Range (UM-1PFC) | 14 mm (X-axis) |
| Micrometer Resolution | 250 µm |
| Dimensions (W×D×H) | 85 × 23 × 53 mm |
| Weight | 102 g (UM-1PF), 106 g (UM-1PFC) |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | UN-3C |
| Travel Range (X/Y/Z) | 14 mm each |
| Dimensions (W×D×H) | 48 × 18 × 60 mm |
| Weight | 84 g |
| Mounting Options | Ø6 mm vertical rod (e.g., URC-1) or M3 threaded hole |
| Type | Manual coarse-positioning micromanipulator for electrochemical and microscale experimental setups |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | 7200 |
| Optical System | Single-beam with 1200 lines/mm diffraction grating |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | 1 nm |
| Stray Light | ≤0.3% T at 360 nm |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–1999 C (0–1999 F) |
| Photometric Accuracy | ±0.8% T |
| Baseline Stability | ±0.004 A/h at 500 nm |
| Detector Type | Photodiode Array |
| Wavelength Operation | Manual selection |
| Display | LED digital display |
| Data Interface | RS-232C serial port, parallel printer port |
| Dimensions | 470 × 400 × 140 mm |
| Weight | 9.5 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2000 |
| Optical System | Single-beam with 1200 lines/mm diffraction grating |
| Wavelength Range | 325–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±1 nm |
| Spectral Bandwidth | 5 nm |
| Stray Light | ≤0.5% T at 360 nm |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–1999 C (0–1999 F) |
| Photometric Accuracy | ±0.5% T |
| Baseline Stability | ±0.003 A/h at 500 nm |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Scanning | Motorized auto-wavelength drive |
| Display | LED digital display |
| Data Interface | RS-232C standard port |
| Printer Interface | Parallel port |
| Dimensions (W×D×H) | 470 × 400 × 140 mm |
| Weight | 9.5 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2100 |
| Optical System | Single-beam with 1200 lines/mm diffraction grating |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.3% T (at 220 nm and 340 nm) |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | 0.1% T |
| Baseline Stability | ±0.002 A/h (at 500 nm) |
| Display | 4-digit LED, resolution 1 nm |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–9999 C (0–1999 F) |
| Data Interface | RS-232C |
| Dimensions (W×D×H) | 470×400×140 mm |
| Weight | 13.5 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2102C |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.4 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | <0.1% T at 220 nm and 340 nm |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–1999 C (0–1999 F) |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.3% T |
| Baseline Stability | ±0.002 A/h at 220 nm and 340 nm |
| Detector Type | Silicon photodiode |
| Wavelength Scanning Mode | Motorized automatic wavelength drive |
| Data Interface | USB port + Parallel printer port |
| Dimensions (W×D×H) | 580 × 450 × 200 mm |
| Weight | 23 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2102PCS |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1000 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5, 1, 2, and 4 nm (selectable) |
| Stray Light | <0.1% T at 220 nm and 340 nm |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–1999 C (or F) |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.3% T |
| Baseline Flatness | ±0.005 A |
| Drift | ±0.002 A/h at 220 nm and 340 nm |
| Detector Type | Silicon photodiode |
| Wavelength Scanning Mode | Automatic |
| Interface | USB port for PC connectivity |
| Dimensions (W×D×H) | 580 × 450 × 200 mm |
| Weight | 24 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2150 |
| Optical System | Single-beam with 1200 lines/mm diffraction grating |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±1 nm |
| Stray Light | ≤0.2% T at 360 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.005 Abs (0.5–1.0 Abs), ±0.3% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Photometric Range | 0–200% T, –0.3 to 3.0 A, 0–9999 C (or F) |
| Baseline Stability | ±0.002 A/h at 500 nm (after warm-up) |
| Display | 126 × 64 dot-matrix graphical LCD |
| Wavelength Resolution | 1 nm |
| Detector Type | Silicon photodiode |
| Interface | USB and Centronics parallel port |
| Dimensions (W×D×H) | 485 × 365 × 220 mm |
| Weight | 14 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2350 |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ±0.2 nm |
| Stray Light | ≤0.2% T at 220 nm and 340 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.005 Abs (0.5–1.0 Abs), ±0.3% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h at 500 nm (after warm-up) |
| Display | 126 × 64 dot-matrix LCD |
| Interface | USB and Centronics |
| Dimensions (W × D × H) | 485 × 365 × 220 mm |
| Weight | 14 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Single-Beam |
| Detector | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ±0.2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.05% T |
| Display | 7-inch capacitive touchscreen (0.1 nm wavelength resolution) |
| Dimensions | 485 × 365 × 220 mm |
| Weight | 14 kg |
| Data Storage | Internal memory for up to 100 measurement files per method and 200 user-defined methods |
| Connectivity | USB port, Bluetooth printing support, mobile app integration (iOS/Android), cloud-ready data export via email/QQ/WeChat |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Single-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T |
| Display | 7-inch high-resolution color touchscreen |
| Data Interface | USB storage, Bluetooth printing & mobile app integration |
| Scan Speed | Up to 3000 nm/min (high mode) |
| Scan Interval Options | 0.1, 0.2, 0.5, 1, 2, 5 nm |
| Kinetic Sampling Interval | 0.5 s minimum |
| Kinetic Duration | Up to 9 hours |
| Calibration Modes | Zero-order, first-order (with/without intercept), second-order, third-order polynomial regression |
| Standard Curve Methods | Single-wavelength, dual-wavelength (isosbestic point), three-point calibration |
| File Capacity | 100 measurement records per test type |
| Compliance | Designed for routine QC and R&D use in GLP-aligned laboratories |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2600A |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1000 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.05% T |
| Detector Type | Silicon Photocell |
| Wavelength Scanning Mode | Motorized Automatic |
| Display | 320 × 240 Graphic LCD |
| Data Interface | USB |
| Dimensions (W×D×H) | 545 × 245 × 260 mm |
| Weight | 20 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2800A |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1000 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.05% T |
| Detector Type | Photocell |
| Wavelength Scanning Mode | Motorized automatic wavelength drive |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port for direct data export to USB flash drive |
| Dimensions (W × D × H) | 545 × 245 × 260 mm |
| Weight | 20 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2802 |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 22 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2802S |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 nm (selectable) |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W×D×H) | 625 × 405 × 280 mm |
| Weight | 20 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-3802 |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W×D×H) | 625 × 405 × 280 mm |
| Weight | 22 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-3802S |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 nm (selectable) |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 24 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4800 |
| Optical System | Dual-Beam |
| Detector Type | Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.1% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Baseline Linearity | ±0.001 A |
| Display | 320 × 240 graphical LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 545 × 245 × 260 mm |
| Weight | 22 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4802 |
| Optical System | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphic LCD |
| Data Interface | USB port |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 23 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | UV-4802S-4 Slit Width |
| Optical System | Dual-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm / ±0.3 nm across range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5, 1, 2, and 4 nm (selectable) |
| Stray Light | ≤0.05% T |
| Photometric Accuracy | ±0.004 Abs (0–0.5 Abs), ±0.004 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Stability | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | 320 × 240 graphical LCD |
| Interface | USB port for data export and software communication |
| Dimensions (W × D × H) | 625 × 405 × 280 mm |
| Weight | 24 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Single-Beam UV-Visible Spectrophotometer |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.2% T (at 340 nm) |
| Photometric Range | 0–125% T, –0.097–1.999 A, 0–1999 C/F |
| Photometric Accuracy | ±0.5% T |
| Baseline Stability | ±0.002 A/h at 500 nm |
| Detector | Photodiode Array |
| Wavelength Setting | Motorized Auto-Scan |
| Display | 4-digit LED, resolution 1 nm |
| Data Interface | RS-232C serial port |
| Printer Port | Parallel interface |
| Dimensions (W×D×H) | 470 × 400 × 140 mm |
| Weight | 10 kg |
| Brand | UNICO |
|---|---|
| Origin | Shanghai, China |
| Model | V-1850 |
| Optical System | Single-beam |
| Detector | Photodiode Array |
| Wavelength Range | 315–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.05% T (at 220 nm & 340 nm) |
| Display Resolution | 0.1 nm |
| Interface | USB, Bluetooth, Touchscreen (7″ TFT, 800×480) |
| Power Input | 80–250 V AC, 50/60 Hz |
| Dimensions | 485 × 365 × 200 mm |
| Weight | 11 kg |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | V-1860 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 315–1050 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ≤1 nm |
| Stray Light | ≤0.05% T |
| Wavelength Display Resolution | 0.1 nm |
| Auto-wavelength Setting | Yes |
| Data Storage | USB flash drive support |
| Connectivity | Bluetooth printing, mobile app (iOS/Android), email/QQ/WeChat sharing |
| Touch Interface | 7-inch capacitive touchscreen |
| Scan Speed | Up to 3000 nm/min (high mode) |
| Scan Interval | Adjustable from 0.1 to 5 nm |
| Kinetic Sampling Interval | Minimum 0.5 s |
| Max Duration | 9 h |
| Calibration Modes | Auto-zero (0% T) and auto-reference (100% T) |
| Curve Fitting | Linear (zero/non-zero intercept), quadratic, cubic regression |
| Data Capacity | 100 test records per method |
| Grating | 1200 lines/mm holographic diffraction grating |
| Brand | UniCo |
|---|---|
| Origin | Shanghai, China |
| Model | V1800 |
| Optical System | Single-beam with 1200 lines/mm holographic grating |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.8 nm |
| Wavelength Repeatability | ±0.2 nm |
| Stray Light | ≤0.2% T at 360 nm |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.005 Abs (0.5–1.0 Abs), ±0.3% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Stability | ±0.002 A/h at 500 nm (after warm-up) |
| Display | 126 × 64 dot-matrix LCD |
| Data Interface | USB and Centronics |
| Dimensions (W×D×H) | 485 × 365 × 220 mm |
| Weight | 13.5 kg |
| Brand | UniCov |
|---|---|
| Origin | Shanghai, China |
| Model | V1600 |
| Optical System | Single-beam |
| Wavelength Range | 325–1000 nm |
| Spectral Bandwidth | 2 nm / 4 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 1 nm |
| Stray Light | ≤0.4% T (at 360 nm) |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs), ±0.005 Abs (0.5–1.0 Abs), ±0.5% T |
| Photometric Repeatability | ±0.001 Abs (0–0.5 Abs), ±0.002 Abs (0.5–1.0 Abs), ±0.2% T |
| Baseline Linearity | ±0.002 A |
| Drift | ±0.002 A/h (at 500 nm, after warm-up) |
| Display | Large LCD with 1 nm wavelength resolution |
| Dimensions | 360 × 280 × 180 mm |
| Weight | Not specified |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | UNIEX-7700PLUS |
| Pricing | Upon Request |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AutoCE-3000 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Application | Organic Analysis |
| Voltage Range | 0 to ±30 kV (adjustable) |
| Cooling Method | Liquid-based Cooling |
| Sample Temperature Control | Water-cooled Thermostatic Module |
| Detector | UV-Vis Photodiode Array Detector (190–600 nm, adjustable wavelength) |
| Operation Modes | Constant Voltage, Constant Current, or Constant Power |
| Injection Mode | Electrokinetic Injection |
| Pressure Range | 0–95 psi |
| Thermal Management System | Closed-loop Liquid Cooling Circuit |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | CWB-001 |
| Pricing | Upon Request |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Model | EasySep-1010 |
| Pump Types | Analytical (10 mL stainless steel head) & Semi-Preparative (50 mL stainless steel head) |
| Flow Range (Analytical) | 0.01–9.99 mL/min |
| Max Pressure (Analytical, SS) | 42 MPa |
| Flow Range (Semi-Prep) | 0.1–49.9 mL/min |
| Max Pressure (Semi-Prep, SS) | 30 MPa |
| Flow Accuracy (Analytical) | RSD ≤ 0.5% at 1 mL/min |
| Flow Precision (Analytical) | RSD ≤ 0.1% at 1 mL/min |
| Flow Accuracy (Semi-Prep) | RSD ≤ 2% at 1 & 10 mL/min |
| Flow Precision (Semi-Prep) | RSD ≤ 0.5% at 1 & 10 mL/min |
| UV-VIS Detector | Wavelength Range 190–360 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Spectral Bandwidth | 8 nm |
| Wavelength Repeatability | ≤ ±0.1 nm |
| Light Source | DX2 Dual-Life Deuterium Lamp |
| Detector Cell Options | Analytical & Semi-Preparative Flow Cells |
| Display | 320×240 dot-matrix LCD |
| System Protection | Soft-start/stop, programmable pressure limits, auto data backup |