Chemical Analysis Instruments
Filter
Showing 1081–1110 of 4337 results
| Brand | BioTools |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ChiralRAMAN-2X |
| Instrument Type | Microscopic Confocal Raman Spectrometer |
| Spectral Range | 100–2000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 1×1 µm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ±0.15 cm⁻¹ |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | ICP-QMS |
| Regulatory Status | NMPA Certified (Registration No.: Jing Xie Zhu Zhun 20192220003) |
| Application Domain | Clinical Biochemical Analysis |
| Detection Limit | Sub-ppt (pg/L) for most elements |
| Linear Dynamic Range | 9 orders of magnitude |
| Isotopic Precision | RSD < 2% (n = 10, standard reference materials) |
| Interference Resistance | Collision/reaction cell enabled (He/H₂ mode), robust polyatomic interference correction |
| Throughput | Up to 40 multi-element clinical samples per hour (including calibration and QC) |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | ICP-MS |
| Model | Clin-ICP-QMS-II |
| Application Domain | Clinical Biochemical Assay |
| Regulatory Classification | Domestic Medical Device (Class II) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Bischoff GmbH |
| Model | RI-8120 (Analytical), RI-8120P (Preparative) |
| Detection Principle | Differential Refractive Index |
| Wavelength | 950 nm LED |
| Optical Sensor | Silicon Photodiode |
| Temperature Control | Integrated Heat Exchanger System |
| Compatibility | HPLC & Prep-LC Systems |
| Compliance | Designed for GLP/GMP environments with stable baseline performance per ISO 17025-relevant operational principles |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BlueSpecCube |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Spectral Range | 300–1000 nm |
| Detector | Back-Illuminated CMOS Linear Array |
| Optical Resolution | < 4.5 nm (FWHM, with 50 µm slit) |
| Sensitivity | 5 × 10¹⁶ counts/W·s @ 300 nm |
| Signal-to-Noise Ratio | 3000:1 (full well, 1 s integration) |
| Dynamic Range | 10,000:1 (typical, single acquisition) |
| Stray Light | < 0.1 % (600 nm, relative to peak) |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 9W |
| Instrument Architecture | Single-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Wavelength Adjustment | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Stray Light | ≤0.5% |
| Objective Magnifications | 20× (NA 0.26), 23× (NA 0.30), 26× (NA 0.34), 29× (NA 0.38) |
| Projection Magnification | 21× |
| Illumination Source | 12 V / 50 W Tungsten-Halogen Lamp |
| Slit Width Adjustment | 0–3 mm (graduated to 0.01 mm) |
| Height Adjustment | 0–20 mm (graduated to 2 mm) |
| Stage Travel | Longitudinal 0–90 mm (1 mm scale), Transverse 0–220 mm (coarse) + 0–25 mm (fine, 0.01 mm resolution) |
| Selenium Photocell Active Area | Ø25 mm |
| Sensitivity | 400–500 µA/lm |
| Lifetime | ≥500 h |
| Galvanometer Sensitivity | 2.5 × 10⁻⁹ A/mm/m |
| Oscillation Period | 1 s |
| Net Weight | 50 kg |
| Dimensions (L × W × H) | 1500 × 900 × 800 mm |
| Brand | Bosin |
|---|---|
| Origin | Shanghai, China |
| Model | PY-1050 |
| Temperature Range | Ambient to 1050 °C |
| Heating Rate | 0.1–100 °C/min |
| Pyrolysis Chamber Material | High-Purity Stainless Steel |
| Carrier Gas | Nitrogen (N₂) |
| Gas Flow Control | 0.1–100 mL/min |
| GC/MS Interface | Standard Transfer Line with Independent Temperature Control (up to 350 °C) |
| Safety Features | Over-Temperature Protection, Real-Time Gas Leak Detection |
| Software | Dual-Language (English/Chinese) Control & Data Acquisition Interface |
| Compliance | Designed for ASTM D7269, ISO 18242, and USP <621> chromatographic method integration |
| Brand | BosinTech |
|---|---|
| Model | C-Nose |
| Origin | Shanghai, China |
| Manufacturer | Shanghai Bosin Industrial Development Co., Ltd. |
| Product Type | Sensory Intelligent Analysis System – Electronic Olfaction Analyzer |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array-Based Volatile Organic Compound (VOC) Profiling |
| Sensor Count | 14 Independent MOS Sensors with Differential Selectivity |
| Detection Limit | Sub-ppb (parts-per-quadrillion equivalent sensitivity in optimized matrix) |
| Sample Analysis Time | 60–120 s |
| Sensor Response Time | <1 s |
| Architecture | Modular Air Chamber Isolation per Sensor |
| Configuration Options | Desktop, Portable, and Online Integration Versions |
| Data Analysis Framework | PCA, SIMCA, PLS-DA, DFA, PLS, and Hierarchical Clustering |
| Compliance Readiness | Supports GLP/GMP-aligned audit trails, 21 CFR Part 11-compliant software modules (optional), ISO 19957 (electronic nose performance validation), ASTM E2813 (odor discrimination testing protocols) |
| Brand | BQC |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BRS |
| Pricing | Available Upon Request |
| Brand | Brabender |
|---|---|
| Origin | Germany |
| Model | MT-C |
| Measurement Principle | Convection Oven Drying (Gravimetric) |
| Compliance | ICC Standard 110/1, ISO 712, EC Regulation No. 2182/2005 (Tobacco), German Legal Metrology Approval for Tobacco Testing |
| Sample Capacity | Up to 10 samples simultaneously |
| Moisture Range | 0.1–99.9% w/w |
| Resolution | 0.1% moisture |
| Maximum Drying Temperature | 200 °C |
| Automation | Fully automated drying, cooling-free re-weighing, and data logging |
| Brand | BRAND® |
|---|---|
| Origin | Germany |
| Model | 4760161 |
| Measurement Range | 0.2–10 mL |
| Meter Accuracy | ±0.1% |
| Meter Resolution | 0.001 mL |
| Dispensing Accuracy | ≤±0.2% |
| Dispensing Resolution | 0.001 mL |
| Compliance | DIN EN ISO 385 (Class A volumetric accuracy) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ATS-051 |
| Instrument Type | Liquid Chromatography Autosampler |
| Sample Channels | 5 |
| Wash Channel | 1 |
| Loop Volumes | 1 mL, 10 mL, 25 mL |
| Injection Volume Range | 1–25 mL |
| Wash Volume | 5 mL (programmable wash modes + manual override) |
| Language Interface | English |
| Operating Temperature | 20–35 °C |
| Dimensions (L×W×H) | 361 × 208.5 × 344.4 mm |
| Weight | 11.4 kg |
| Power Supply | 100–120 VAC / 200–240 VAC, 50/60 Hz |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Computrac MAX-4000XL |
| Price Range | USD $12,500 – $37,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Computrac MAX-5000XL |
| Price Range | USD $13,500 – $40,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Computrac Vapor Pro XL |
| Application | Multi-purpose moisture analyzer |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 ppm |
| Repeatability | ≤10% C.V. (for samples >0.1% moisture), ≤15% C.V. (for samples <0.1% moisture) |
| Temperature Range | 25–300°C |
| Sample Weight | 0.01–8 g |
| Display Units | %, ppm, µg |
| Storage Capacity | 250 methods, 1000 results, 100 moisture curves |
| End Criteria | Predictive, Rate, Time, Time-Rate |
| Calibration | NIST-traceable capillary |
| Power | 100–120 V~ / 220–240 V~, 50/60 Hz |
| Dimensions | 17.2 × 47 × 27.9 cm |
| Weight | 8.0 kg |
| Certifications | UL, CE |
| Compliance Options | 21 CFR Part 11 (optional), ASTM D7191-10, ASTM D7546-15 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SuperFlux™ |
| Instrument Type | Online Raman Spectrometer |
| Laser Wavelength | 785 nm |
| Optical Architecture | HTVS™ (High-Throughput Virtual Slit) Technology |
| Safety Features | Integrated laser fiber break detection and hardware interlock |
| Compliance | FDA 21 CFR Part 11 ready |
| Enclosure Rating | Suitable for hazardous (explosion-proof) areas |
| Form Factor | Standalone, compact benchtop unit |
| Brand | Brookman |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PB7220-2000-T |
| Pricing | Available Upon Request |
| System Bandwidth | 1.7–2.1 THz |
| Spectral Resolution | 0.1–5 GHz |
| Dynamic Range | 70 dB (at 100 GHz), 45 dB (at 1 THz), 40 dB (at 2 THz) |
| THz Beam Diameter (FWHM @ 0.5 THz) | 12 mm |
| Optical Path Length | 25 cm |
| Tuning Speed | 10 GHz/s |
| Electronic Chopper Frequency | 6 kHz |
| Dual-Channel Operation | Transmission + Reflection/Scattering Simultaneously |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ultra-High-Field NMR Spectrometer |
| Operating Frequencies | 1.1 GHz (⁴⁷/⁴⁹Ti, ¹H), 1.2 GHz (¹H) |
| Sample Compatibility | Solid–Liquid Dual-Mode |
| Acquisition Method | Pulsed Fourier Transform NMR |
| Magnet Technology | Actively Shielded Superconducting Magnet |
| Probe Options | 3 mm TCI Cryoprobe, 5 mm Triple-Axis Gradient Cryoprobe, 111 kHz MAS Solid-State NMR Probe |
| Detection Modes | Direct ¹³C and ¹⁵N Detection, Parallel Multi-Receiver Acquisition |
| Application Focus | Structural Biology, Intrinsically Disordered Proteins (IDPs), Membrane Proteins, Large Macromolecular Complexes |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A2B |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Type | Solid |
| Sensitivity | Signal-to-Noise Ratio (SNR) |
| Resolution | Spectral Linewidth |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | A300/A200 |
| Instrument Type | Continuous-Wave (CW) EPR |
| Design Architecture | A300 – Modular Benchtop System |
| Regulatory Compliance | Designed for GLP/GMP-aligned laboratories |
| Software Framework | Bruker Xenon™ EPR Software Suite |
| Hardware Interface | Digital Signal Processing (DSP) Architecture with Real-Time Data Acquisition |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ALPHA II |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Spectral Range | 7500–375 cm⁻¹ |
| Spectral Resolution | 0.8 cm⁻¹ |
| Scan Speed | 3 spectra/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ascend Evo 1.0 GHz NMR |
| Price Range | USD $10–20 million |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State & Solution-State |
| Operating Frequency | 1.0 GHz |
| Acquisition Mode | Pulsed Fourier Transform (PFT) & Continuous Wave (CW) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | autoflex maX |
| Instrument Type | TOF-TOF |
| Application Scope | Universal |
| Laser Repetition Rate | up to 2 kHz |
| Mass Resolution | up to 26,000 (m/z 1,000–5,000) |
| Mass Accuracy | sub-ppm (calibrated) |
| Detection Sensitivity | low amol (for peptides) |
| Ion Source | Perpetual™ laser-cleanable MALDI source |
| Detector | FlashDetector™ with 10-bit digitizer |
| Software Suite | Compass (flexControl, flexAnalysis, BioTools, GlycoWorkbench, Polymerix) |
| Brand | Bruker |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AVANCE NEO NMR Spectrometer with Ascend Evo Magnet |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State and Solution-State |
| Operating Frequency | 400 MHz |
| Acquisition Method | Pulsed Fourier Transform (PFT-NMR) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | High-Field NMR Spectrometer |
| Model | AVANCE NEO 500M |
| Sample Compatibility | Liquid and Solid-State (Dual-Mode) |
| Sensitivity | High Signal-to-Noise Ratio (SNR) |
| Resolution | High Spectral Resolution (Narrow Linewidth) |
| Magnet System | ASCEND™ 500 MHz Superconducting Magnet |
| Console Architecture | Integrated Embedded Acquisition Server (TopSpin 4+) |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible software modules available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVANCE NEO 600M NMR Spectrometer (Ascend Evo Magnet) |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid and Liquid Samples |
| Operating Frequency | 600 MHz |
| Data Acquisition Method | Pulsed Fourier Transform |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | AVANCE NEO |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State & Solution-State (Dual-Mode) |
| Operating Frequency Range | 300–800 MHz (scalable to ≥1.25 GHz) |
| Data Acquisition Method | Pulse Fourier Transform (PFT) |
| Architecture | Integrated Transceiver-Based Digital RF Platform |
| Software Platform | TopSpin 4.x or later with Embedded Acquisition Server |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Online Process Spectrometer |
| Model | BEAM |
| Design | Single-Channel FT-NIR |
| Sample Interface | In-line / At-line (pipeline, hopper, conveyor-mountable) |
| Optical Principle | Interferometric Fourier Transform Spectroscopy |
| Spectral Range | Typically 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | ≤4 cm⁻¹ (user-selectable) |
| Detector | Thermoelectrically Cooled InGaAs |
| Measurement Mode | Real-time, Continuous, Non-destructive |
| Compliance | Designed for GMP/GLP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | BRAVO |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 300–3200 cm⁻¹ |
| Spectral Resolution | 10–12 cm⁻¹ |
| Spatial Resolution | 1–2 mm spot diameter |
| Minimum Wavenumber | 300 cm⁻¹ |
| Spectral Reproducibility | ±100% (relative intensity stability across repeated acquisitions under identical conditions) |