| Brand | Banff |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | QitVenture 6 E |
| Instrument Type | Portable GC-MS |
| Ionization Sources | ESI, TD-ESI, APCI |
| Mass Analyzer | Quadrupole |
| Mass Range | 10–1000 m/z |
| Battery Runtime | >4 hours (typical operational mode) |
| Dimensions | <38 × 28 × 18 cm |
| Weight | <12 kg |
| Sample Introduction | Gas, Liquid, Solid (via integrated thermal desorption and direct probe options) |
| Brand | Baode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Online Mercury Analyzer |
| Model | ARA-7 |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Wavelength | 253.7 nm |
| Sample Matrix | Aqueous environmental and industrial wastewater |
| Compliance | HJ 597–2011 (China), ASTM D3559, ISO 12846 |
| Key Components | Integrated DRA-7 wet digestion module + DRD-7 CVAAS detector |
| Automation Level | Fully automated digestion, reduction, amalgamation, desorption, detection, and cleaning |
| Brand | Baode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SGM-9 |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Compliance Standard | JIS B 7994 |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CS206 |
| Price Range | USD 14,000 – 42,000 (FOB Shanghai) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 3.5 kW High-Frequency Induction Furnace |
| Measurement Range | C: 0.0001–10 wt% |
| S | 0.0001–5 wt% (extendable to 99.99 wt% for both elements) |
| Sensitivity | 0.01 ppm |
| Precision | C: ±1.0 ppm or RSD ≤ 0.5% |
| S | ±1.0 ppm or RSD ≤ 1.0% (per certified reference materials per ISO/IEC 17025 validation protocols) |
| Analysis Time | 20–40 s per sample |
| Gas Flow Control | High-Accuracy Mass Flow Controller (MFC) |
| Combustion Atmosphere | Purified Oxygen Supply with Optional Oxygen Purification Module |
| Sample Handling | Automated Ash Removal & Multi-Stage Filtration |
| Optional Accessories | Physical Water Removal Unit, Constant-Temperature Furnace Head, Multi-Point Oxygen Injection |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Oxygen-Nitrogen Analyzer |
| Model | ON-316 |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Oxygen Range | 0.1 ppm – 5000 ppm (low), 0.5% – 20% (high) |
| Nitrogen Range | 0.1 ppm – 5000 ppm (low), 0.5% – 50% (high) |
| Detection Limit | 0.01 ppm |
| Accuracy | ±1 ppm or RSD ≤ 1% (O₂/N₂) |
| Analysis Time | O₂: 120–180 s |
| N₂ | 120–240 s |
| Pulse Furnace Power | 8.0 kW |
| Detector Configuration | Dual-channel NDIR for oxygen, TCD for nitrogen |
| Sample Form | Solid metals and non-metals (powders, chips, rods, pellets) |
| Compliance Support | ASTM E1019, ISO 14284, GB/T 11261, JIS G 1211 |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ONH-316 |
| Instrument Type | Oxygen/Nitrogen/Hydrogen Elemental Analyzer |
| Oxygen Range | Low-O: 0.1–5000 ppm |
| High-O | 0.5–20 wt% |
| Nitrogen Range | Low-N: 0.1–5000 ppm |
| High-N | 0.5–50 wt% |
| Hydrogen Range | 0.1–5000 ppm |
| Accuracy | O/N: ±1 ppm or RSD ≤ 1% |
| H | ±0.2 ppm or RSD ≤ 2% (relative to certified reference material uncertainty) |
| Sensitivity | 0.01 ppm |
| Analysis Time (O) | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Model | ONH-316 |
| Detection Principle | Inert Gas Fusion Coupled with Non-Dispersive Infrared (NDIR) and Thermal Conductivity Detection (TCD) |
| Oxygen Range | High-O: 0.5–20 wt% |
| Low-O | 0.1–5000 ppm |
| Nitrogen Range | High-N: 0.5–50 wt% |
| Low-N | 0.1–5000 ppm |
| Hydrogen Range | 0.1–5000 ppm |
| Precision | O/N: ±1 ppm or RSD ≤ 1% |
| H | ±0.2 ppm or RSD ≤ 2% |
| Sensitivity | 0.01 ppm |
| Analysis Time | O: 120–180 s |
| N | 120–240 s |
| H | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Detector Configuration | Dual-channel NDIR for O/C (CO), Single-channel TCD for H₂ and N₂ |
| Gas Handling | EPC-controlled pneumatic architecture with independent electronic pressure control (EPC) per gas path |
| Calibration Options | Single-point, multi-point, and slope/intercept correction |
| Software Compliance | Audit trail, user-level access control, data export in CSV/Excel, optional 21 CFR Part 11 compliance module |
| Structural Design | Integrated monolithic chassis housing furnace, gas analysis module, electronics, and industrial-grade embedded PC |
| Brand | Baoying Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Line | TC-306 Series |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Elemental Analyzer |
| Analytical Range | O: 0.1 ppm – 10 wt% |
| Low N | 0.1 ppm – 5000 ppm |
| High N | 0.5 – 30 wt% |
| H | 0.1 ppm – 5000 ppm |
| Analytical Precision | O & N: ±1 ppm or RSD ≤ 1.0% |
| H | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | O: 120–180 s |
| N | 120–240 s |
| H | 120–180 s |
| Pulse Furnace Power | 8.0 kW |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TC-306 |
| Price Range | USD 14,000 – 42,000 |
| Instrument Type | Simultaneous O/N/H Analyzer |
| Analytical Range | Oxygen/Nitrogen/Hydrogen — Low-level mode: 0.1 ppm to 5,000 ppm |
| High-level mode | 0.5 wt% to 30 wt% |
| Accuracy | ±1 ppm or RSD ≤ 1% (for nitrogen) |
| Sensitivity | 0.01 ppm |
| Analysis Time | 120–240 s per sample (for nitrogen determination) |
| Pulse Furnace Power | 8 kW |
| Detection Principle | Inert Gas Fusion coupled with NDIR (Non-Dispersive Infrared) and TCD (Thermal Conductivity Detection) |
| Cooling System | Precision Water Temperature Control Unit |
| Footprint | Freestanding Floor Model (no lab bench required) |
| Optional Module | Remote Diagnostic Interface |
| Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASESPION |
| Price | ¥280,000 |
| Brand | Batop |
|---|---|
| Origin | Germany |
| Model | TDS10XX |
| Spectral Range | 0.05–4 THz (laser-dependent) |
| Spectral Resolution | 2 GHz (equivalent to ~0.025 cm⁻¹) |
| Imaging Resolution | 1280 × 1024 pixels |
| Field of View (TFOV) | 8° |
| Instantaneous Field of View (IFOV) | 0.18 mrad |
| Frame Rate | 15 fps |
| Beam Diameter | 22 mm (collimated), 1 mm @ 1 THz (focused) |
| Sample Size Support | up to 30 × 30 mm (collimated), ≥5 × 5 mm (focused) |
| Dynamic Range | >65–75 dB |
| Scan Range | 500–650 ps |
| THz Pulse Repetition Rate | 1–30 kHz (10 kHz default) |
| Bias Voltage for PCA Emitter | 10 V |
| Operating Mode | Free-space or fiber-coupled (1550 nm / 1060 nm options) |
| Environmental Compatibility | N₂-purged sample chamber |
| Brand | BaySpec |
|---|---|
| Origin | USA |
| Manufacturer | BaySpec, Inc. |
| Type | Portable / Handheld Raman Spectrometer |
| Model | Nano-LB |
| Spectral Range | 300–2000 cm⁻¹ or 300–2500 cm⁻¹ (configurable) |
| Spectral Resolution | 12–15 cm⁻¹ (Rayleigh criterion) |
| Dimensions | 63 mm × 39 mm × 17 mm (compact variant) / 70 mm × 56 mm × 27 mm (belt-wearable variant) |
| Weight | 63 g / 118 g |
| Laser Source | Integrated diode laser, output power <150 mW (software-adjustable) |
| Power Supply | Rechargeable Li-ion battery, ≥8 h continuous operation |
| Connectivity | Bluetooth 5.0 + USB 3.0 |
| Control Interface | LightSpec mobile app (Android) and PC software |
| Detection Mode | Point-and-shoot with ergonomic button or software-triggered acquisition |
| Brand | BaySpec |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OCI-M |
| Operating Principle | Pushbroom Scanning |
| Imaging Modality | 3D Hyperspectral Data Cube Acquisition |
| Deployment Platform | Ground-based and Airborne Compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5 nm (FWHM) |
| Spatial Resolution | 1000 pixels across track × L pixels along track |
| Total Field of View (TFOV) | 18° |
| Frame Rate | 120 fps |
| Interface | USB 3.0 |
| Dimensions | 30 mm × 30 mm × 75 mm |
| Weight | 117 g |
| Real-time Preview | Yes |
| Scan Time per Cube | ≤5 s |
| Data Cube Generation Time | ≤10 s |
| Brand | BaySpec |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Portability/Continuity/Agility |
| Instrument Type | Portable |
| Mass Range | 30–1600 Da |
| Dynamic Range | 3.5 orders of magnitude |
| Mass Resolution (FWHM) | 0.49 Da |
| Maximum Scan Rate | 15,000 Da/s |
| Mass Accuracy | ±0.3 Da |
| Weight | 10–20 kg |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Instrument |
| Model | 960A |
| Instrument Type | Multifunctional Autosampler |
| Sample Introduction Ports | 16-position |
| Compatible Sample Containers | Vacuum Sampling Canisters & Tedlar® Bags |
| Entire Gas Path Heating | Yes (Uniform Temperature Control) |
| Gas Path Surface Treatment | Fused Silica Inert Coating (Verified via Inertness Testing) |
| Multi-Position Injection Valve | Bidirectional Rotational Actuation |
| Flow Path Optimization | Minimized Contact Time Between Sample and Valve Core |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 960SN |
| Instrument Type | Multifunctional High-Pressure Autosampler |
| Pricing | Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BCT-700 |
| Temperature Control Range | 0–45 °C (ambient operating environment) |
| Gas Flow Rate | 0.1 MPa, 100 mL/min ±5 mL/min |
| Tube Capacity | 21 positions (3 independent zones × 7 tubes each) |
| Aging Zone Temperature Range | Ambient to 400 °C ±1 °C |
| Vaporization Zone Temperature Range | 0–200 °C ±1 °C |
| Aging Time Setting | 0–999 min |
| Sample Introduction Flow (Calibration Standard Prep) | 0–100 mL/min ±1 mL/min |
| Input Pressure Limit | ≤0.4 MPa |
| Power Supply | AC 220 V, 50–60 Hz, 400 W |
| Dimensions | 380 × 270 × 230 mm |
| Weight | ≤10 kg |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | BCT-CMM |
| Instrument Type | Portable |
| Pricing | Upon Request |
| Vacuum System | Non-mechanical (e.g., turbomolecular or ion pump based) |
| Positioning | GPS and/or BeiDou GNSS optional |
| Connectivity | 5G-enabled real-time data transmission |
| Software Platform | Dedicated mobile monitoring application with georeferenced chromatographic data logging |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BCT950M |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 5–1000 mL (standard configuration) |
| Sampling Mechanism | Canister-based automated sampling |
| Sample Loop Volume Range | 0.1 µL – 30 mL |
| Transfer Line Length | < 0.5 m |
| Transfer Line Max Temperature | > 200 °C |
| Sample Path Surface Treatment | Deactivated fused-silica throughout |
| Focusing Trap | Integrated independent cryo-focusing trap for secondary focusing of loop- or trap-desorbed analytes |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-E2 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Pricing | Available Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Oven Temperature Range | Ambient to 225 °C |
| Valve & Transfer Line Temperature Range | Ambient to 225 °C |
| Sample Loop Volume | 1 mL |
| Sample Position Capacity | 12 positions |
| Vial Sizes Supported | 10 mL and 20 mL vials |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | 5–220 °C |
| Valve & Loop Temperature Control Range | 5–220 °C |
| Sample Loop Volumes | 0.5 mL, 1 mL, 3 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 46 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | P6100 |
| Pricing | Upon Request |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | BE-8 |
| Travel Range (Coarse X-axis) | 40 mm |
| Mounting Interface | 10 mm diameter rod |
| Dimensions (W×D×H) | 140 × 25 × 95 mm |
| Weight | 210 g |
| Type | Single-Axis Coarse Micromanipulator |
| Application | Stereotactic Auxiliary Positioning |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr InKjel Series (InKjel1210M, InKjel625P, InKjel1225M, InKjel450P, InKjel475M) |
| Digestion Time Range | 1–199 min |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | >99.5% |
| Power Input | 750–1500 W (adjustable 0–100% in 1% increments) |
| Voltage | 230 VAC / 115 VAC, 50/60 Hz |
| Dimensions (W × D × H) | ≈54 × 44 × 75 cm |
| Weight (incl. reaction tubes) | ≈20 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr K8 / K12 / K20 Standard Kjeldahl Digestion System |
| Price Range | USD 13,500 – 27,000 |
| Instrument Type | Kjeldahl Nitrogen Digestion System |
| Digestion Time Range | 1–99 minutes |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Behr Kjeldahl Digestion System with Automatic Lift Arm |
| Price Range | USD 13,500 – 27,000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Distillation Time | 1–99 minutes |
| Repeatability | ±0.5% |
| Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr Micro Kjeldahl Digestion System K16, K24, K40 |
| Digestion Time Range | 1–99 min |
| Repeatability | ±0.5% |
| Nitrogen Recovery Rate | >99.5% |
| Power Rating | 750–1500 W |
| Sample Capacity | 16 / 24 / 40 positions |
| Digestion Tube Volume | 100 mL |
| Voltage Options | 230 V~ or 115 V~ |
| Housing Material | Corrosion-Resistant Stainless Steel |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr S1, S2, S3, S4 Kjeldahl Distillation Systems |
| Price Range | USD 13,500–27,000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Distillation Time | 1–99 min |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 750–1500 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr S5 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Distillation Time | 1–99 min |
| Repeatability | ≤0.5% CV (RSD ≤1%) |
| Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Voltage | 115–230 V~, 50/60 Hz |
| Cooling Water Flow | ~5 L/min |
| Dimensions (W×H×D) | 410 × 675 × 410 mm |
| Weight | ~36 kg |
| Titration Interface | RS232 |
| Display | LCD |
| Preprogrammed Methods | 100 |
| Compatible with External Titrator | Yes |