Chemical Analysis Instruments
Filter
Showing 121–150 of 4194 results
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.250P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.1–125 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV Wavelength Range | 200–800 nm |
| Detection Cell | 1.3 mm pathlength, 55 µL volume |
| Gradient Capability | Quaternary solvent delivery with automated degassing |
| Column Compatibility | Up to 60 mm internal diameter |
| Fraction Collection | 132-position rack (18 × 150 mm tubes, configurable) |
| Control Interface | 15″ HD capacitive touchscreen |
| Software Platform | InterSoft X Genius (KISS-compliant, drag-and-drop gradient editor, method automation, audit-trail-ready) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.400 |
| Flow Rate Range | 0–125 mL/min |
| Maximum Pressure | 400 bar |
| Wavelength Range | 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Detection Channels | Dual-wavelength (UV-Vis) with full-spectrum acquisition capability |
| Column ID Support | Up to 60 mm |
| Sample Capacity | 132-tube rack (18 × 150 mm), configurable for alternative formats |
| Touchscreen Interface | 15-inch HD capacitive touchscreen |
| Gradient Capability | Quaternary solvent delivery |
| Injection Modes | Liquid injection and dry-load (Load&Go) via 6-port + 10-port valve manifold |
| Flow Cell | 1.0 mm pathlength, 20 µL volume |
| Compliance | Designed for GLP-compliant workflow execution |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 535-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–400 mL/min |
| Maximum Operating Pressure | 35 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash XS 520plus |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0.1–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| Column ID Compatibility | Up to 80 mm |
| Typical Prep Scale | 4–800 g |
| Detector Options | UV/Vis, iELSD, Mass Spectrometry (MS) Interface Capable |
| Software Platform | InterSoft X |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash® Active Splitter |
| Pricing | Available Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | vAPCI |
| Instrument Type | Ion Source |
| Application Specificity | Dedicated Gas-Phase Interface |
| Analyte Polarity Range | Non-polar to Moderately Polar Compounds |
| Sensitivity | Compatible with Advion expression CMS Mass Spectrometer |
| Resolution | Defined by Coupled Mass Analyzer (e.g., Quadrupole) |
| Accurate Mass Capability | ±0.1 Da (when calibrated and operated under optimized conditions) |
| Operating Pressure | Ambient Atmospheric Pressure (~760 Torr) |
| Brand | Advion |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ICP-001/E01 |
| Instrument Type | Quadrupole Mass Spectrometer |
| Mass Resolution (at 10% peak height, unit mass) | 0.9 amu |
| Detection Limits (ng·L⁻¹) | Be < 1 |
| Sensitivity (Mcps / mg·L⁻¹) | Li > 20 |
| Brand | AdvR |
|---|---|
| Origin | USA |
| Type | Fiber-Coupled Electro-Optic Phase Modulator |
| Wavelength Range | 397–1064 nm |
| Max. Optical Input Power | 1 W |
| Modulation Bandwidth | Up to 10 GHz |
| Insertion Loss | ≤ 5 dB |
| Half-Wave Voltage (Vπ) | 3–8 V (wavelength-dependent) |
| Polarization-Maintaining Fiber | PM400, PM480, PM630, PM780, PM850, PM980 |
| Compliance | RoHS, CE, ISO 9001-certified manufacturing |
| Brand | AECC (Aviation Engine Corporation of China) |
|---|---|
| Origin | Beijing, China |
| Model | LPG-2000 |
| Light Source | DC-pulsed hollow cathode discharge (low-pressure) |
| Optical Chamber | Evacuated vacuum chamber |
| Wavelength Range | 170–430 nm |
| Grating | Holographic concave grating, focal length 750 mm, 2400 grooves/mm |
| Spectral Resolution | < 0.024 nm |
| Detector | Hamamatsu high-sensitivity, low-noise photomultiplier tube (PMT) |
| Elemental Coverage | Ag, As, Au, B, Ba, Be, Bi, Ca, Cd, Ce, Cu, Ga, Ge, Hg, In, La, Mg, Mn, P, Pb, Pd, Pt, Rh, Ru, Sb, Se, Si, Sn, Sr, Te, Tl, Y, Zn, Zr (including sub-190 nm lines for B and P) |
| Detection Limits | 1×10⁻⁵% to 1×10⁻⁷% (e.g., Bi ≤ 0.00001%, As ≤ 0.0005%, P ≤ 0.001%, B ≤ 0.001%) |
| Precision | RSD < 20% for 10 replicate excitations on homogeneous samples |
| Temperature Control | Thermostabilized optical chamber, ±0.1 °C stability |
| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabPrep |
| Pricing | Upon Request |
| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PrepPlus |
| Pricing | Upon Request |
| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickPrep |
| Pricing | Upon Request |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AFX1000-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Ground-based & UAV-mounted |
| Spectral Range | 400–1000 nm (HSI) + 8–14 µm (LWIR) |
| Thermal Imaging Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Frame Acquisition Rate | ≥300 Hz (full spectral cube acquisition) |
| Total Field of View (TFOV) | 30.5° |
| Instantaneous Field of View (IFOV) | 2.7 mrad |
| RGB Camera | 26 MP synchronized capture |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AFX1700-IR |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Platform Compatibility | Ground-based and UAV-mounted |
| Spectral Range | 900–1700 nm (VNIR/SWIR HSI) + 8–14 µm (LWIR thermal) |
| Thermal Spatial Resolution | 640 × 512 pixels (full-frame radiometric temperature mapping) |
| Maximum Data Acquisition Rate | ≥500 Hz across full spectral bands |
| Total Field of View (TFOV) | 35.5° |
| Instantaneous Field of View (IFOV) | 3.5 mrad |
| RGB Camera Resolution | 26 MP |
| System Mass | <2.5 kg |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EM38-MK2 |
| Detection Parameters | Dual-frequency electromagnetic induction (EC and magnetic susceptibility) |
| Portability | Airborne & Ground-portable |
| Application Environment | Field-deployable for aerial and terrestrial geophysical surveys |
| Electrical Conductivity Range | 0–1000 mS/m (4-digit resolution) |
| TDS Equivalent Range | ±28 ppt at 1-m coil separation |
| Accuracy | ±0.1% of full scale |
| Coil Separations | 1.0 m and 0.5 m (dual independent dipole receivers) |
| Operating Frequency | 14.5 kHz |
| Weight | 5.4 kg |
| Compliance | Designed for ISO 11277-compliant soil characterization workflows and ASTM D6439-22 (Standard Guide for Use of Electromagnetic Induction Methods in Geotechnical Investigations) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Hyper-Cam |
| Pricing | Available Upon Request |
| Operating Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Imaging Architecture | Dispersive (Grating-Based) |
| Deployment Mode | Ground-Based & Airborne Compatible |
| Spectral Range | 7.7–12.5 µm (MWIR) |
| Spectral Resolution | Up to 0.25 cm⁻¹ |
| Spatial Resolution (IFOV) | 0.45 mrad (typical, lens-dependent) |
| Detector Format | 320 × 256 HgCdTe FPA |
| Field of View (TFOV) | 6.4° × 5.1° |
| Frame Rate | Up to 60 Hz (full-frame, binning-dependent) |
| Calibration | Onboard Blackbody + Ambient Reference |
| Compliance | ISO/IEC 17025-aligned calibration traceability, GLP-compliant data acquisition workflow |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NSpec |
| Energy Resolution | ≤ 1.85 keV @ 1.33 MeV |
| Relative Efficiency | 20% @ 1.33 MeV (vs. 3"×3" NaI, Co-60, 25 cm) |
| Resolution @ 122 keV | ≤ 875 eV |
| Peak-to-Compton Ratio | ~51:1 |
| FWTM/FWHM | 1.9 |
| FWFM/FWHM | 2.65 |
| Energy Range | 40–3000 keV |
| Cooling Method | Liquid Nitrogen Cryogenic |
| Form Factor | Integrated Miniaturized Unit (Detector + Dewar + MCA + Display) |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | RedEdge-P |
| Pricing | Available Upon Request |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | X20P-IR |
| Spectral Range | 350–1000 nm (VNIR) + 7.5–13.5 µm (LWIR) |
| Spectral Resolution | 164 bands (VNIR), 640 × 512 pixels (LWIR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Field of View (TFOV) | 35° |
| Instantaneous Field of View (IFOV) | < 1.5 mrad (typ.) |
| Imaging Modality | Snapshot-based dispersive hyperspectral imaging with concurrent uncooled microbolometer LWIR imaging |
| Platform Compatibility | Ground-based tripod mounting and UAV-integrated operation (multirotor & fixed-wing) |
| Integrated Stabilization | Brushless gimbal with SkyPort digital interface |
| Onboard Storage | Embedded solid-state storage |
| Data Synchronization | Hardware-triggered, frame-locked VNIR/LWIR acquisition |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LIR |
| Spectral Range | 350–1000 nm (VIS-NIR) + 905 nm (LiDAR) + 7.5–13.5 µm (MWIR/LWIR) |
| Spectral Resolution | ≥2 cubes/s (1886 × 1886 pixels per cube) |
| Spatial Resolution (IFOV) | ≤0.008° |
| Field of View (TFOV) | 0.008° |
| Frame Rate | ≥2 hyperspectral cubes per second |
| Image Format | 1886 × 1886 pixels per spectral cube |
| Thermal Imaging | 640 × 512 uncooled microbolometer, radiometrically calibrated |
| LiDAR Range | 450 m (@80% reflectivity) |
| Platform Compatibility | UAV-mounted (ground & airborne operation) |
| Onboard Systems | Integrated IMU, real-time georeferencing engine, solid-state storage, embedded control unit |
| Brand | AERO |
|---|---|
| Origin | Beijing, China |
| Model | X20P-LV |
| Spectral Range | 350–1000 nm (hyperspectral) + 905 nm (LiDAR) |
| Spatial Resolution | 1886 × 1886 pixels per hyperspectral cube |
| Frame Rate | 2 cubes/s |
| Spectral Channels | 164 (expandable) |
| LiDAR Range | 450 m (@ 80% reflectivity) |
| LiDAR Accuracy | ±2 cm (1σ @ 20 m) |
| FOV | 0.008° |
| IFOV | 2 cubes/s, 1886 × 1886 pixels/cube |
| IMU Accuracy | Heading ±0.038°, Attitude ±0.008° |
| Data Interface | 2× GigE, 2× USB, HDMI |
| Onboard Storage | 256 GB SSD + 8 GB RAM |
| Sensor Configuration | 20 MP hyperspectral CMOS + 3.5 MP panchromatic sensor + solid-state 905 nm LiDAR |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Model | Aerodyne N2O |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer (IRMS) Equivalent |
| Detection Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) |
| Measurement Targets | N₂O, δ¹⁵Nα (¹⁵N¹⁴N¹⁶O), δ¹⁵Nβ (¹⁴N¹⁵N¹⁶O), δ¹⁸O (N₂O) |
| Detection Limit | <1 ppt (v/v) for N₂O |
| Temporal Resolution | 1–10 Hz (configurable) |
| Path Length Options | 76 m or 400 m multipass cell |
| Precision (100 s) | δ¹⁵Nα ≤ 0.08‰, δ¹⁵Nβ ≤ 0.5‰, δ¹⁸O ≤ 0.5‰ |
| Operating Temperature Range | 10–35 °C (ambient) |
| with thermostatic enclosure | −20 to +40 °C |
| Temperature Stability | ±0.1 °C at setpoint (typically 30 °C) |
| Power Requirement | 500 W, 120/240 VAC, 50/60 Hz (pump excluded) |
| Dimensions (76 m) | 650 × 430 × 270 mm (W×D×H) |
| Weight | 35 kg |
| Dimensions (400 m) | 560 × 770 × 640 mm |
| Weight | 75 kg |
| Sampling Flow Rate | 0–20 slpm |
| Data Interfaces | RS-232, USB, Ethernet |
| Time Synchronization | GPS-enabled NTP server support |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Instrument Type | Stable Isotope Ratio Mass Spectrometry (IRMS)-Grade Laser Absorption Spectrometer |
| Measurement Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) with Astigmatic Multipass Cell |
| Detection Limits | Sub-ppt for N₂O, CH₄ |
| δ¹³C-CO₂ precision | 0.02‰ (120 s) |
| δ¹⁸O-CO₂ precision | 0.03‰ (120 s) |
| Sampling Frequency | 1–10 Hz configurable |
| Certified Compliance | ASTM D6348, ISO 13877 (adapted), GLP/GMP-ready data audit trail per FDA 21 CFR Part 11 |
| Software | TDLWINTEL v5.2 with HITRAN spectral replay, zero-spectrum background subtraction, real-time laser frequency stabilization, and passive cavity drift correction |
| Brand | AES |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CEInfinite |
| Voltage Input | 100/240 VAC, 50–60 Hz |
| Cooling Method | Liquid-based Thermostatic Control |
| Sample Temperature Range | 4–10 °C |
| Detector | Scientific CMOS (sCMOS) Imaging Sensor |
| Separation Mode | Voltage Gradient iCIEF |
| Sample Introduction | Automated Capillary Injection |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC 600DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Oven Cool-Down | 300°C to 50°C in ≤5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NC1000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Semiconductor Gas Analysis |
| Temperature Control Range | 0–300 °C |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cool-down Time | ~5 min (300 °C → 50 °C) |
| Carrier Gas Flow Range | 0–900 mL/min |
| Carrier Gas Pressure Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Pulsed Helium Discharge Ionization Detector (DID) |
| Detection Range | ppb to % level |
| Accuracy | ±1% of full scale |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with resistive touchscreen |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack-mount, 5U) |
| Weight | 25 kg |
| Carrier Gas | Ultra-high-purity helium (N6.0, 20–60 mL/min) |
| Sample Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Dry, oil-free air at 300 kPa |
| Electronic Pressure/Flow Control | 0–5 bar output (5–10 bar input) |
| Output Signals | 0–1 V analog |
| Compliance | Designed for ASTM D7527, ISO 8573-5, IEC 61511, and aligned with USP <621>, FDA 21 CFR Part 11 data integrity requirements for electronic records |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Temperature Stability | < ±0.05 °C/h (after 30 min warm-up) |
| Cooling Rate | 300 °C to 50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Max Temperature | 300 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Hydrogen Analysis |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increments) |
| Cool-down Time | ~5 min (300 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 10–500 mL/min |
| Detector | Helium Ionization Detector (DID) |
| DID Measurement Range | ppb to % level |
| DID Accuracy | ±1% of full-scale reading |
| DID Operating Temperature | 30–45 °C |
| Ambient Operating Temperature | 10–30 °C |
| DID Response Time (90%) | 0.5 s |
| DID Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa (3 bar) |
| Electronic Gas Control | 5–10 bar input → 0–5 bar regulated output |
| Standard Fittings | 1/8″ stainless steel Swagelok® and VCR |
| Output Signal | 0–1 V analog |
| Alarm Outputs | Detector, system, flow, maintenance, temperature, pressure |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus, RS-485 |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC100 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Oven Temperature Range | +5–450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 300–50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| DID Operating Temp | 30–45 °C |
| Ambient Temp Requirement | 10–30 °C |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa |
| Electronic Gas Control | Input 5–10 bar, output control 0–5 bar |
| Output Signal | 0–1 V analog |
| Communication | 4–20 mA, Profibus, Modbus RTU, RS-485 via TrendVision PLUS |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4°C to 450°C |
| Temperature Stability | < ±0.05°C/h (after 30 min warm-up) |
| Cooling Rate | 300°C → 50°C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 300°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |