Chemical Analysis Instruments
Filter
Showing 1651–1680 of 10663 results
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Ultrospec 7500 |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ±0.5 nm |
| Spectral Bandwidth | <2 nm |
| Stray Light | <0.05 %T at 220 nm (NaI) or 340 nm (NaNO₂), <0.10 %T at 380 nm (NaNO₂) |
| Automation | Automatic Wavelength Scanning |
| Compliance | Optional 21 CFR Part 11 Software Module (Resolution™) |
| Brand | BioLight |
|---|---|
| Model | Lux-P110 |
| Detection Principle | Photon counting via cooled photomultiplier tube (PMT) |
| Dynamic Range | ≥ 7 decades (typical for high-end luminometers) |
| Sensitivity | ≤ 10 amol ATP (firefly luciferase assay, 96-well plate) |
| Read Modes | Flash & Glow luminescence |
| Plate Formats | 6–1536-well microplates |
| Temperature Control | Ambient to 45 °C (±0.5 °C uniformity) |
| Integrated Injector | Dual-channel, programmable, in-situ dispensing |
| Shaking | Tri-mode (linear, orbital, circular) with six speed settings (200–1200 rpm) |
| Detector | Thermoelectrically cooled PMT (−20 °C operating temperature) |
| Software | LuxWin v5.x with FDA 21 CFR Part 11-compliant audit trail, GLP/GMP reporting templates, and kinetic/endpoint/multiple-injection protocols |
| Compliance | ISO/IEC 17025-aligned validation support, ASTM E2578-21 referenced for luminometer performance verification |
| Data Export | CSV, XML, PDF, Excel-compatible formats |
| Brand | BioLight |
|---|---|
| Model | Lux-T020 |
| Origin | Guangdong, China |
| Detector Type | Electrochemiluminescence & Bioluminescence Luminometer |
| Photomultiplier Tube (PMT) | Single-Photon Counting PMT |
| Max Count Rate | >100 million pulses/sec |
| Detection Sensitivity | ≤10 amol ATP or 20 zmol firefly luciferase |
| Dynamic Range | 7 decades (linear) |
| Sample Format | 12 × 55 mm test tubes or standard 0.5–2.0 mL microcentrifuge tubes |
| Interface | Touchscreen GUI with USB data export |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Lyotherm3 |
| Pricing | Available Upon Request |
| Brand | Biopharma |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Micropress |
| Pricing | Available Upon Request |
| Brand | Bioseps |
|---|---|
| Origin | Tianjin, China |
| Model | DAC100/150 (Single-Column Configuration) |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Sealing Technology | High-Pressure Spring-Energized PTFE-Coated O-Ring Seal |
| Column Connection | C-Clamp Quick-Release Bottom Endcap |
| Pressure Actuation | Hydraulic Jack with Pneumatic Control Option for Hazardous Environments |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | AS30 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Method | Non-contact spray spotting with programmable overlap capability |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.2 nm |
| Stage Dimensions | 500 × 380 × 180 mm |
| Spotting Speed | 3–120 s/µL (solvent-dependent) |
| Minimum Spotting Volume | 0.1 µL |
| Volume Range Options | 0.1–10 µL and 0.1–100 µL |
| Spotting Precision | ±0.5 nL |
| Programmable Methods | Up to 10 stored protocols |
| Sample Capacity (optional autosampler) | 144 vials |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | CD60 |
| Instrument Type | HPTLC Densitometer |
| Operation Mode | Fully Automated |
| Detection Modes | Absorption, Reflection, Fluorescence, Transmission |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, Mercury Lamp |
| Monochromator | Stepper Motor-Driven Holographic Grating (1200 lines/mm) |
| Spectral Bandwidth | 5–260 nm |
| Wavelength Accuracy | < ±0.1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Spatial Resolution | 0.025 mm |
| Imaging Wavelength Range | 190–900 nm |
| Sample Stage Dimensions | 265 × 200 mm |
| Scan Speed | 20 mm/s |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | SG1 / DS20 |
| Spray Method | Programmable, Quantitative, Region-Specific Aerosol Deposition |
| Droplet Size | 1–10 µm |
| Spray Platform Area | 20 × 20 mm |
| Scan Speed | 50–200 mm/s |
| Wavelength Range | 2–4 mm (Note: This value is physically inconsistent with optical spectroscopy |
| likely refers to spray nozzle orifice diameter — corrected to “Nozzle Orifice | 2–4 mm”) |
| Light Sources | Deuterium lamp, Tungsten-halogen lamp, Mercury lamp |
| Wavelength Reproducibility | < 0.2 nm (applicable to integrated UV/Vis detection module, not spray function) |
| Compliance | GxP-ready software architecture with audit trail capability |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | DD80 |
| Instrument Type | Automated TLC Imaging & Densitometry System |
| Operation Mode | Fully Automatic |
| Detection Mode | Low-Fluorescence Substance Imaging |
| Wavelength Options | 254 nm and 366 nm UV |
| Light Sources | White LED, UV Fluorescent Lamps, UV LEDs |
| Imaging Sensor | 24-Megapixel Full-HD Digital Camera |
| Spectral Bandwidth Management | Auto Background Correction & Real-Time Image Optimization |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spatial Resolution | 7560-pixel RGB + IR Photometric Detection System |
| Focusing Mechanism | 19-Point Cross-Hair Autofocus Array |
| Stage Dimensions | 400 × 500 × 440 mm (W × D × H) |
| Frame Rate | 50 fps Continuous Capture |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Dalton 2000 |
| Ionization Sources | APCI (ESI optional) |
| Mass Range | 10–2000 m/z |
| Resolution | <0.7 FWHM at m/z |
| Mass Accuracy | ±0.1 m/z |
| Flow Rate Compatibility | 10–100 mL/min |
| Dimensions | 28 × 56 × 66 cm |
| Weight | 54 kg |
| Nitrogen Supply Pressure | 4.1–6.9 bar |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera |
| Instrument Type | Medium- to Low-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–200 mL/min |
| Maximum Pressure | 145 psi (10 bar) |
| Detection Wavelengths | 254 nm, 200–400 nm, 200–800 nm (optional) |
| UV Flow Cell Path Length | 0.3 mm |
| Fraction Collection Tube Diameters | 13, 16, 18, or 25 mm |
| Solvent Channels | 2 or 4 (configurable) |
| Sample Loading Capacity | mg to 75 g |
| Application Level | Laboratory-Scale Purification |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Dalton 2000 |
| Application Level | Laboratory |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤ 2 × 10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Mass Range | m/z 80–2000 |
| Ionization Modes | Simultaneous Positive/Negative APCI (ESI optional) |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera LS |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 50–500 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi (10 bar) |
| Wavelength Range | 200–400 nm (standard UV), optional 200–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Brand | BioTools |
|---|---|
| Origin | USA |
| Model | ChiralIR-2X |
| Instrument Type | Vibrational Circular Dichroism (VCD) Spectrometer |
| Spectral Range | 4000–850 cm⁻¹ (standard), optional extension to 10,000 cm⁻¹ (NIR) |
| Baseline Drift | < 2 × 10⁻⁵ AU |
| Signal-to-Noise Ratio | >3.6× improvement over single-source systems |
| Detector Continuous Operation | 30–48 hours |
| Optical Path | Fully automated alignment and calibration |
| Data Acquisition | Digital signal processing (no lock-in amplifiers or analog filtering required) |
| Sample Stage | SyncRoCell™ rotating sample cell platform |
| DualPEM™ capability | Optional upgrade for solid-sample VCD correction |
| Brand | BioTools |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | ChiralRAMAN-2X |
| Instrument Type | Microscopic Confocal Raman Spectrometer |
| Spectral Range | 100–2000 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | 1×1 µm |
| Minimum Wavenumber | 100 cm⁻¹ |
| Spectral Reproducibility | ±0.15 cm⁻¹ |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | ICP-QMS |
| Regulatory Status | NMPA Certified (Registration No.: Jing Xie Zhu Zhun 20192220003) |
| Application Domain | Clinical Biochemical Analysis |
| Detection Limit | Sub-ppt (pg/L) for most elements |
| Linear Dynamic Range | 9 orders of magnitude |
| Isotopic Precision | RSD < 2% (n = 10, standard reference materials) |
| Interference Resistance | Collision/reaction cell enabled (He/H₂ mode), robust polyatomic interference correction |
| Throughput | Up to 40 multi-element clinical samples per hour (including calibration and QC) |
| Brand | Bioyong |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | ICP-MS |
| Model | Clin-ICP-QMS-II |
| Application Domain | Clinical Biochemical Assay |
| Regulatory Classification | Domestic Medical Device (Class II) |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Bischoff GmbH |
| Model | RI-8120 (Analytical), RI-8120P (Preparative) |
| Detection Principle | Differential Refractive Index |
| Wavelength | 950 nm LED |
| Optical Sensor | Silicon Photodiode |
| Temperature Control | Integrated Heat Exchanger System |
| Compatibility | HPLC & Prep-LC Systems |
| Compliance | Designed for GLP/GMP environments with stable baseline performance per ISO 17025-relevant operational principles |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-UV254 |
| Wavelength Range | 248–262 nm |
| Peak Wavelength | 254 nm |
| Measurement Range | 1 µW/cm² to 39.99 mW/cm² |
| Resolution | 1 µW/cm² |
| Spectral Band Rejection (Out-of-Band) | <0.1% |
| Accuracy | ±8% + 2 digits |
| Linearity Error | ±1% |
| Range Switching Error | ±1% |
| Sampling Rate | 2 Hz |
| Display | 3¾-digit LCD with backlight |
| Overload Indication | "OL" |
| Operating Temp./RH | 0–45 °C / 0–70% RH |
| Storage Temp./RH | −10–50 °C / 0–80% RH |
| Power | Three 3 V CR2032 coin cells |
| Battery Life | ~300 h (backlight off) |
| Auto Power-Off Delay | 5 min |
| Host Dimensions | 160 × 78 × 34 mm |
| Probe Dimensions | Ø50 × 40 mm |
| Telescopic Handle | 12 cm (single-stage), 24 cm (dual-stage) |
| Probe Cable Length | 1 m (including handle) |
| Weight | ~405 g (with batteries and probe) |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | H5220(C) |
| Detection Limit | <1 µg/m³ (for benzene) |
| Repeatability | 1% |
| Linear Range | 10⁵ |
| Column Oven Temperature Range | Ambient to 200 °C (programmable) |
| Zero Drift | ≤1% FS/month |
| Span Drift | <1% FS/24 h |
| Power Supply | Internal Li-ion battery (6 h operation) |
| Operating Environment | −20 °C to +45 °C, 20–90% RH |
| Gas Inlet | 1/8″ stainless steel Swagelok fitting |
| Detector | Photoionization Detector (PID) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | S400-RTPBO-M10ST |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BlueSpecCube |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Spectral Range | 300–1000 nm |
| Detector | Back-Illuminated CMOS Linear Array |
| Optical Resolution | < 4.5 nm (FWHM, with 50 µm slit) |
| Sensitivity | 5 × 10¹⁶ counts/W·s @ 300 nm |
| Signal-to-Noise Ratio | 3000:1 (full well, 1 s integration) |
| Dynamic Range | 10,000:1 (typical, single acquisition) |
| Stray Light | < 0.1 % (600 nm, relative to peak) |
| Brand | BM |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 9W |
| Instrument Architecture | Single-Beam |
| Detector Type | Photomultiplier Tube (PMT) |
| Wavelength Range | 200–1000 nm |
| Wavelength Adjustment | Manual |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.2 nm |
| Stray Light | ≤0.5% |
| Objective Magnifications | 20× (NA 0.26), 23× (NA 0.30), 26× (NA 0.34), 29× (NA 0.38) |
| Projection Magnification | 21× |
| Illumination Source | 12 V / 50 W Tungsten-Halogen Lamp |
| Slit Width Adjustment | 0–3 mm (graduated to 0.01 mm) |
| Height Adjustment | 0–20 mm (graduated to 2 mm) |
| Stage Travel | Longitudinal 0–90 mm (1 mm scale), Transverse 0–220 mm (coarse) + 0–25 mm (fine, 0.01 mm resolution) |
| Selenium Photocell Active Area | Ø25 mm |
| Sensitivity | 400–500 µA/lm |
| Lifetime | ≥500 h |
| Galvanometer Sensitivity | 2.5 × 10⁻⁹ A/mm/m |
| Oscillation Period | 1 s |
| Net Weight | 50 kg |
| Dimensions (L × W × H) | 1500 × 900 × 800 mm |
| Brand | Bode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BCODMn-60S |
| Pricing | Upon Request |
| Brand | Bode Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BDCFA-800 |
| Pricing | Available Upon Request |
| Instrument Type | Continuous Flow Analyzer |