| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCP-803 |
| Current Range | ±80 A |
| Current Resolution | 760 pA (1 nA–400 nA range) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Dynamic Potential Resolution | 300 µV (adjustable down to 5 µV) |
| EIS Frequency Range | 10 µHz–1 MHz (standard), 10 µHz–10 kHz (with 80 A booster) |
| Booster Module | Removable high-current extension unit |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | HCV-3048 |
| Current Range | ±30 A (per channel), up to ±120 A (4-channel parallel operation) |
| Current Accuracy | 0.1–0.3% (range + reading) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Range | 0–48 V |
| Voltage Accuracy | 0.03% (range + reading) |
| Slew Rate | >20 V/µs |
| Rise/Fall Time | <3 µs (0–48 V step) |
| Input Impedance | 100 GΩ |
| Bandwidth | 800 kHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | M470 |
| Instrument Type | Scanning Electrochemical Workstation |
| Current Range | 1 pA – 10 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Scan Range (X/Y/Z) | >100 mm |
| Closed-Loop Positioning Resolution | 0.1 nm |
| Spatial Resolution (X/Y/Z) | 20 nm |
| Max Scan Speed | 12.5 mm/s |
| ADC/DAC Resolution | 32-bit @ up to 40 MHz |
| Piezo Vibration Range | 20 nm – 2 µm (peak-to-peak, 1 nm step) |
| Piezo Minimum Vibration Resolution | 0.12 nm (16-bit DAC, 4 µm range) |
| Piezo Extension | 100 µm |
| Piezo Positioning Resolution | 0.09 nm (20-bit DAC, 100 µm range) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MOS-450 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Light Sources | 150 W Xenon Lamp + 150 W Mercury-Xenon Lamp |
| Wavelength Range | 165–900 nm |
| Wavelength Accuracy | ±0.1 nm (165–900 nm) |
| Optical System | Dual Grating (1200 grooves/mm) |
| Stray Light | < 2 × 10⁻⁴ % (at 200 nm) |
| Noise Level (CD) | 0.01 mdeg |
| Baseline Stability | < 0.01 mdeg/hr |
| Data Acquisition Rate | 10 µs to 1000 s per point |
| Stopped-Flow Unit | Triple-/Quadruple-Channel Mixing, Independent Stepper-Motor Control per Channel |
| Minimum Injection Volume | 10 µL |
| Flow Rate per Channel | 0.01–1.0 mL/s |
| Mixing Ratio Range | Continuously Adjustable from 1:1 to 1:100 |
| Minimum Dead Time | 0.25 ms (with micro-volume detection cell) |
| Expandable Modules | Cryo-Quench, Sub-Zero Stopped-Flow, Temperature-Jump (T-Jump), Auto-Titration, In-Situ Micro-Conductivity Detection |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MOS-500 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Light Sources | 150 W Xenon Lamp + 150 W Mercury-Xenon Lamp |
| Detection Modes | CD, UV-Vis Absorption, Fluorescence CD (FCD), Linear Dichroism (LD), Fluorescence Anisotropy |
| Wavelength Range | 163–950 nm (extendable to 1250 nm) |
| Wavelength Accuracy | ±0.1 nm (163–1250 nm) |
| Optical System | Dual Grating Monochromator |
| Stray Light | <2 × 10⁻⁶ at 200 nm |
| Baseline Stability | 0.007 mdeg/hr |
| Maximum Scan Speed | 12,000 nm/min |
| Solid Sample Capability | Integrated Integrating Sphere for Diffuse Reflectance |
| Stopped-Flow Unit | Triple- or Quadruple-Channel Mixing with Independent Stepper-Motor Control |
| Minimum Injection Volume | 10 µL |
| Flow Rate Range | 0.01–40 mL/s |
| Mixing Ratio Range | Continuously Adjustable from 1:1 to 1:100 |
| Mixer Type | Spherical High-Efficiency Mixing Cell |
| Dead Time | 0.2 ms (with Microcell Accessory) |
| Expandable Modules | Cryo-Quench, Sub-Zero Stopped-Flow, Temperature-Jump (T-Jump), Automated Titration, Microconductivity Detection |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG-2XX |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 A |
| Current Accuracy | ±20 nA on 10 μA |
| Potential Accuracy | <5 mV on ±2.5 V |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | MPG2 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±10 A (per channel with optional high-current modules) |
| Current Resolution | 760 pA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 20 kHz |
| Data Acquisition Rate | 200,000 points/s |
| Channels | 16 independent, fully isolated |
| Voltage Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | SFM-100+MOS-LED |
| Instrument Architecture | Single-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 180–820 nm |
| Wavelength Accuracy | ±0.1 nm |
| Spectral Bandwidth | 0–16 nm (adjustable) |
| Stray Light | ≤2 ppm |
| Dead Time | 5 ms (motor-driven), 8 ms (manual) |
| Sample Consumption per Experiment | 30 µL |
| Mixing Chamber Dead Volume | 20 µL |
| Mixing Ratio | Variable |
| Control Interface | USB |
| Detection Modes | Standard Absorbance (default), optional Fluorescence and Dual-Absorbance modes |
| Software | Spec-Lab v5.x |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SFM-3000 |
| Number of Syringes | 3 |
| Drive Mechanism | Stepper Motor per Syringe |
| Minimum Dead Time | 0.25 ms (microcell) / 0.6 ms (FC-08 cell) |
| Flow Rate Range | 0.01–10 mL/s |
| Mixing Ratio Range | 1:1 to 1:100 (continuously adjustable) |
| Temperature Control | Jacketed Cell with External Circulator |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-150e |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Dual-Channel |
| Current Range | ±1 A |
| Current Resolution | 760 pA (optional 76 fA) |
| Current Accuracy | ±20 nA on 10 μA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Voltage Resolution | 300 μV (dynamically adjustable down to 5 μV) |
| Data Acquisition Rate | 200,000 points/s |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-200 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | ±12 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Resolution | 1 µV (dynamic range adjustable down to 1 µV) |
| Data Acquisition Rate | 1,000,000 points/second |
| Optional ULC Module | 100 pA (down to 1 pA) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-300 |
| Channel Count | Dual-channel |
| Current Range | ±500 mA |
| Current Resolution | 76 aA |
| Potential Accuracy | ±1 mV |
| Potentiostatic Range | ±48 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | 1,000,000 pts/s |
| Voltage Resolution | 1 µV (dynamic range adjustable) |
| Optional Modules | ULC (1 pA), High-Current (4 A/14 V), High-Voltage (1 A/48 V) |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | SP-50e |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±20 nA (on 10 μA range) |
| Potential Accuracy | <5 mV (on ±2.5 V range) |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 μHz to 1 MHz |
| Current Resolution | 760 pA |
| Voltage Resolution | Adjustable from 300 μV down to 5 μV |
| Data Acquisition Rate | 200,000 points/s |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Uniscan M370 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.1% of reading |
| Potential Accuracy | ±10 mV |
| Potentiostatic Range | ±20 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-300 |
| Number of Channels | 16 |
| Current Range | ±500 mA |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Voltage Compliance | ±12 V |
| Control Voltage Range | ±10 V |
| Current Resolution (standard board) | 760 fA |
| Floating Mode | Yes |
| Analog Filtering | Built-in |
| Calibration Board | Integrated |
| Control Stability | Digital PID with adaptive tuning |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VMP-3e |
| Channel Count | 16 independent channels |
| Current Range | 76 fA to 100 A (with external amplifiers) |
| Current Accuracy | ±0.1% |
| Potential Range | ±10 V (DC), 0–20 V (galvanostatic mode) |
| Potentiostatic Range | ±20 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Data Acquisition Rate | 200,000 points/sec |
| Potential Resolution | 300 µV (dynamic range adjustable down to 5 µV) |
| Switching Time (Potentiostatic ↔ Galvanostatic) | <10 µs |
| Input Impedance | >10^14 Ω |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP |
| Channel Count | 5 independent channels |
| Current Range | 1 nA to 100 A (with external amplifier) |
| Current Resolution | 76 fA |
| Potential Accuracy | ±5 µV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A (built-in), up to ±100 A (with external current booster) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Data Acquisition Rate | 200,000 points/s |
| Voltage Resolution | 300 µV (dynamic adjustment down to 5 µV) |
| Supported Techniques | CV, LSV, CA, CP, EIS (potentiostatic/galvanostatic/step-mode), DPV, SWV, NPV, Mott-Schottky, ZRA/ZVC, corrosion polarization, GITT, PITT, constant-power discharge, potentiometric titration, and multi-step sequence protocols |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-300 |
| Channel Count | 6 |
| Current Range | ±500 mA |
| Current Resolution | down to 76 aA (with ULC option) |
| Current Accuracy | ±20 nA on 10 µA range |
| Potential Accuracy | <5 mV on ±2.5 V range |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±1 A (extendable to ±20 A) |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Sampling Rate | up to 1 µs |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software | EC-Lab® v12+ with FDA 21 CFR Part 11-compliant audit trail option |
| Brand | Bio-Logic |
|---|---|
| Origin | France |
| Model | VSP-3e |
| Channel Count | 8 |
| Current Range | ±1 pA to ±1 A |
| Current Accuracy | ±0.0033% of reading |
| Potential Accuracy | ±1 µV |
| Potentiostatic Range | ±10 V (adjustable up to ±20 V) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Voltage Resolution | 5 µV (within ±200 mV range) |
| Current Resolution | 0.76 nA |
| Minimum Sampling Interval | 200 µs |
| Control Bandwidth | 7 adjustable bandwidths |
| Connectivity | Ethernet (LAN), USB, optional EIS module |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BioLogic DuoFlow System |
| Maximum Pressure | 3500 psi (23 MPa) |
| Flow Rate Range | 0.01–80 mL/min (configurable via pump head selection) |
| UV Detection Wavelengths | Fixed 254/280 nm |
| Conductivity Range | 1–500 mS/cm |
| UV Sensitivity | 0.0001–2.0 OD |
| Fraction Collection Modes | Time-based (0.03–999 min), Drop-based (0–9999 drops), Volume-based, Large-volume (20 positions, up to 500 mL each) |
| Temperature-Controlled Operation | Compatible with chromatography cold cabinets (4–10 °C) |
| System Biocompatibility | Fully bio-inert fluidic path (PEEK, titanium, sapphire, fused silica) |
| Software Platform | BioLogic System Controller v5.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Model | Biochrom 30+ |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pump Pressure | 45 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control | 5 °C to ambient |
| Post-Column Reactor Temperature Range | 40–150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Detection Limit (Ninhydrin) | 2.5 pmol (S/N = 2) |
| Typical Sensitivity | 9 pmol (average across all amino acids) |
| Precision | 0.5% CV at 10 fmol |
| Column Packing | 8 µm Cation-Exchange Resin |
| Column Temperature Control | Peltier, 20–99 °C |
| Derivatization Temperature | 145 °C |
| Buffer Delivery | Dual-pump system (buffer + ninhydrin), ceramic piston pumps with automated pump-head wash |
| Nitrogen Protection | 5 bar high-purity N₂ for buffer stabilization |
| Sample Capacity | 84 positions |
| Sample Tray Cooling | Down to 4 °C |
| Resolution | >95% average peak resolution |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biochrom 30+ |
| Price Range | USD 92,000 – 132,000 (based on exchange rate and configuration) |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–130 mL/hr |
| Maximum Pump Pressure | 45 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control | 4 °C to ambient, continuously adjustable |
| Post-Column Reactor Temperature Range | 40–145 °C |
| Detection Wavelengths | 570 nm and 440 nm (dual-wavelength, self-calibrating, parallel signal output with summation capability) |
| Flow Cell Volume | 8 µL |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop DUO+ |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Cuvette Pathlength | 10 mm |
| Sample Volume (min) | 0.5 µL |
| Fixed Microvolume Pathlength | 0.5 mm ± 5 µm |
| Absorbance Range | –0.3 to 2.5 A |
| Stray Light | <0.5% T at 220 nm & 340 nm (NaNO₂) |
| Detector | 1024-pixel CCD array |
| Light Source | Pulsed Xenon Lamp (3-year warranty) |
| Display | 7-inch capacitive color touchscreen |
| Dimensions | 410 × 280 × 190 mm |
| Weight | 3.55 kg |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BioDrop μLite+ |
| Price | Upon Request |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Biowave 3 |
| Optical System | Pseudo-double-beam |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Spectral Bandwidth | 3 nm or 5 nm (selectable) |
| Stray Light | ≤0.5% at 220 nm and 340 nm |
| Absorbance Range | –0.3 to 2.5 A |
| Light Source | Xenon flash lamp |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Biowave 3+ |
| Optical Design | Single-beam |
| Detector | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 3 nm |
| Stray Light | <0.5% T at 340 nm |
| Absorbance Range | –0.3 to 2.5 A |
| Built-in Applications | Nucleic Acid Quantification, Protein Assays (UV280, Bradford, Lowry, Biuret), Fluorescent Dye Labeling Efficiency, OD600 Cell Density, Melting Temperature (Tm) Analysis |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Lightwave 3 |
| Optical Design | Single-beam with diode array detection |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 5 nm (3 nm optional) |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.5% at 220 nm and 340 nm |
| Detector | CCD array |
| Light Source | Long-life xenon lamp |
| Absorbance Range | –0.3 to 2.5 A |
| Measurement Modes | Scanning, Fixed-wavelength, Kinetics, Concentration (factor, single-point, multi-standard calibration, multi-wavelength ratio) |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | Lightwave 3+ |
| Optical Design | Single-beam |
| Detector Type | CCD Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 3 nm |
| Stray Light | <0.5% T at 340 nm |
| Display | 5-inch color touchscreen |
| Absorbance Range | –0.3 to 2.5 A |
| Cuvette Compatibility | Up to 40 mm pathlength |
| Automation | Motorized wavelength scanning |
| Light Source | Xenon flash lamp |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultrospec 30 |
| Pricing | Available Upon Request |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Model | Ultrospec 35c |
| Wavelength Options | 450, 500, 520, 540, 600, 640 nm |
| Display | 4.3-inch color touchscreen |
| Data Export | CSV format to USB drive |
| Power Options | Internal rechargeable battery or AC adapter |
| Sample Format | Cuvette- or test-tube-based liquid samples |
| Measurement Modes | Absorbance and Transmittance |
| Kinetics Capability | Basic time-resolved absorbance monitoring |
| Compliance | Designed for GLP-supporting workflows in academic, industrial, and field laboratories |