Chemical Analysis Instruments
Filter
Showing 1711–1740 of 10663 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C-Type |
| Pricing | Upon Request |
| Compliance | ASTM D2414, ASTM D3493 |
| Drive Unit | AC Variable-Frequency Motor |
| Power | 0.75 kW |
| Speed Range | 5–150 rpm |
| Default Speed (ASTM) | 125 rpm |
| Speed Stability | Quartz-Crystal Digital Feedback Controlled |
| Torque Measurement | Electronic Load Cell |
| Torque Range | 0–10 N·m |
| Titration Rate | Adjustable (Default 4 mL/min per ASTM) |
| Titration Accuracy | ±0.05 mL |
| Sample Cup Capacity | 100 mL |
| Power Supply | 230 V AC, 50/60 Hz, 4 A |
| Dimensions (L×W×H, w/o burette) | 530 × 560 × 700 mm |
| Weight | Approx. 75 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Computrac MAX-4000XL |
| Price Range | USD $12,500 – $37,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Computrac MAX-5000XL |
| Price Range | USD $13,500 – $40,500 |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Computrac Vapor Pro XL |
| Application | Multi-purpose moisture analyzer |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 ppm |
| Repeatability | ≤10% C.V. (for samples >0.1% moisture), ≤15% C.V. (for samples <0.1% moisture) |
| Temperature Range | 25–300°C |
| Sample Weight | 0.01–8 g |
| Display Units | %, ppm, µg |
| Storage Capacity | 250 methods, 1000 results, 100 moisture curves |
| End Criteria | Predictive, Rate, Time, Time-Rate |
| Calibration | NIST-traceable capillary |
| Power | 100–120 V~ / 220–240 V~, 50/60 Hz |
| Dimensions | 17.2 × 47 × 27.9 cm |
| Weight | 8.0 kg |
| Certifications | UL, CE |
| Compliance Options | 21 CFR Part 11 (optional), ASTM D7191-10, ASTM D7546-15 |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Heating Range | Ambient to 200 °C (1 °C increment) |
| Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.5 °C |
| Vial Capacity | 10 positions |
| Vial Size | 20 mL |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EMP-3 |
| Pricing | Upon Request |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EMP-Gold+ |
| Pricing | Upon Request |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FRINGE |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Supply | Standard 220 V AC, 50/60 Hz (cooling integrated |
| Detector | Digital Pulse Processing Counter (DPPC), ≥1×10⁷ counts per second (CPS), energy-dispersive capability enabled |
| Optical Geometry | Bragg–Brentano θ–2θ reflection mode with fixed divergence slit, Soller slits, anti-scatter slit, and receiving slit |
| Sample Stage | Motorized goniometer with ±0.001° angular reproducibility |
| Software | CrystalX — automated phase identification, quantitative Rietveld refinement, crystallinity index calculation, and elemental spectral overlay (EDS-compatible) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | FRINGE EVS |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | kW-class (water-cooled) |
| Detector | DPPS High-Resolution Energy-Dispersive Detector |
| Cooling System | Integrated Closed-Loop Water Circulation |
| Safety | Interlocked Sample Chamber with Auto-Shutdown, Full Enclosure During Operation |
| Optical Path | Integrated Soller Slit (Fixed, No Moving Parts) |
| Software | CrystalX™ Automated Phase Identification & Quantification Suite |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~10 min (400 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–10,000 kPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HS-3 |
| Pricing | Available Upon Request |
| Sample Heating Range | 40–200 °C |
| Valve Heating Range | 40–200 °C |
| Transfer Line Heating Range | 40–200 °C |
| Sampling Time | 0–20 min |
| Pressurization Time | 0–30 s |
| Purge Time | 0–60 min |
| Injection Time | 0–20 min |
| Loop Volume | 1 mL |
| Vial Capacity | 10 mL or 20 mL |
| Sample Positions | 12 |
| Heating Zone | Single-zone (1 position) |
| RSD | ≤1.5% (for 200 ppm ethanol in water) |
| Power Consumption | 300 W |
| Dimensions (W×D×H) | 500×180×400 mm |
| Net Weight | ~25 kg |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PeDX G7 |
| Application | Handheld/Portable |
| Instrument Type | Conventional EDXRF |
| Industry-Specific Use | Non-Ferrous Metals |
| Elemental Range | Al (13) to U (92) |
| Detection Limit | ppm-level quantification |
| Form Factor | Portable handheld spectrometer |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PeDX OIL |
| Form Factor | Handheld / Portable |
| Instrument Type | Conventional EDXRF Spectrometer |
| Application Scope | General-Purpose Petrochemical Analysis |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% (for S and key wear metals/additives) |
| Energy Resolution | <136 eV (at Mn Kα) |
| Repeatability (RSD) | ≤0.1% for sulfur in stable matrix conditions |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | SHINE Geochemistry Edition (Minerals & Rocks) |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Transmission |
| X-ray Source | Microfocus Tube with Collimator |
| Detector | CCD-based 2D Detector |
| Sample Form | Loose Powder (≈20 mg) |
| Sample Handling | Vibration-assisted Random Orientation |
| Data Output | Full 2θ Diffraction Pattern |
| Connectivity | USB / Bluetooth / Wi-Fi |
| Environmental Rating | IP54 (Dust- and Splash-Resistant) |
| Radiation Safety | Fully Shielded, Zero Leakage During Operation |
| Compliance | Meets GB/T 15445–2021 (Chinese Standard for Portable XRD), Designed per IEC 61010-1 Safety Requirements |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SHINE Research Edition |
| Instrument Type | Powder X-ray Diffractometer |
| Geometry | Transmission-mode |
| Detection | CCD-based 2D detector |
| Sample Form | Loose powder (no pressing required) |
| Sample Mass | ~20 mg per analysis |
| Data Output | Full-pattern XRD + simultaneous XRF elemental data |
| Connectivity | USB / Bluetooth / Wi-Fi |
| Enclosure | IP65-rated ruggedized portable case |
| Radiation Safety | Fully shielded |
| Software | Integrated phase identification & quantitative Rietveld refinement engine |
| Brand | LANScientific |
|---|---|
| Model | TrueX 760 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable EDXRF Spectrometer |
| Application Domain | Soil & Environmental Field Screening |
| Regulatory Scope | RCRA Metals, EPA Priority Pollutants, ISO 12847, ASTM D6359, USP <232>/<233> (for elemental impurities in environmental matrices) |
| Detection Range | Elements from Mg (Z=12) to U (Z=92) |
| Typical Detection Limits | 1–10 mg/kg (ppm) for heavy metals (Pb, As, Cd, Cr, Hg, Ni, Cu, Zn) in soil matrices |
| Sample Form | Solid, powder, slurry filtrate, filter membrane, thin film, bulk sediment |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) with Peltier-cooled Si-PIN or SDD detector |
| Operating Mode | Direct-field analysis without sample preparation |
| Compliance | GLP-compliant data logging, audit trail ready, 21 CFR Part 11 optional configuration |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TrueX 800 |
| Application | Handheld / Portable |
| Instrument Type | Conventional EDXRF |
| Industry-Specific Use | Non-Ferrous & Ferrous Alloys |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD for major elements |
| Detector | Si-PIN Semiconductor Detector |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | TrueX 900 |
| Price Range | USD $14,000–$42,000 |
| Application | Handheld/Portable |
| Instrument Type | Conventional EDXRF |
| Industry-Specific Use | Geological & Mineral Exploration |
| Elemental Range | Mg (12) to U (92) |
| Detection Limit | ppm-level quantification |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TrueX 960 |
| Application | Handheld / Portable |
| Instrument Type | Conventional |
| Industry Use | General-Purpose |
| Elemental Range | Mg to U |
| Quantitative Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% |
| Detector | High-Resolution Silicon Drift Detector (SDD) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TrueX800 |
| Application | Handheld / Portable |
| Instrument Type | Standard EDXRF |
| Industry Use | General-Purpose |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | ±0.1% RSD |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Total Reflection XRF (TXRF) |
| Configuration | Portable / Field-Deployable |
| Sample Forms | Liquids, Suspensions, Solid Thin Films, Particulates |
| Primary Application Domains | Environmental Monitoring (Soil & Atmospheric Aerosols), Regulatory Compliance Screening, Trace Element Analysis |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TX3000 |
| Application | Field-Portable |
| Instrument Type | Total Reflection X-Ray Fluorescence (TXRF) |
| Industry-Specific Use | Soil & Atmospheric Analysis |
| Sample Forms | Liquid, Suspension, Solid, Particulate Deposits |
| Detection Principle | Grazing-Incidence Excitation with Multilayer Monochromator |
| Key Elements | Cr, Pb, As, Cd, Hg, Ni, Cu, Zn (expandable to ~30 elements) |
| Minimum Sample Volume | <10 µL (liquid) or <100 ng (solid deposit) |
| Detection Limits | Sub-pg to low-pg range for most metals (e.g., 0.1–5 pg for transition metals under optimized conditions) |
| Radiation Safety | Compliant with GBZ 126–2011 and IEC 62495 |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TX3000 |
| Application | Field-Portable |
| Instrument Type | Total-Reflection X-Ray Fluorescence (TXRF) |
| Industry-Specific Use | Soil & Atmospheric Environmental Monitoring |
| Sample Form Compatibility | Liquid, Suspension, Solid, Filter-Collected Particulates |
| Detection Principle | Grazing-Incidence Excitation with Multilayer Monochromator and Silicon Drift Detector (SDD) |
| Key Performance | Sub-pg Absolute Detection Limits for Heavy Metals (e.g., Cr, Pb, As, Cd, Hg, Ni, Cu, Zn), Simultaneous Multi-Element Quantification (up to 30 elements), Minimal Sample Requirement (<10 µL liquid or <1 mg solid) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Instrument Type | Handheld LIBS Analyzer |
| Model | LIBS 800 |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 (Software Mode), ISO/IEC 17025–compatible workflow support |
| Laser Class | 3B (IEC 60825-1:2014) |
| Weight | 1.65 kg |
| Spectral Range | 190–950 nm |
| Optical Resolution | ≤0.1 nm (FWHM) |
| Detection Limits | Sub-ppm to % level (matrix-dependent) |
| Analysis Time | <2 s per measurement |
| Sample Interaction | Non-contact, micro-destructive (crater diameter <100 µm) |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | MA-3 Solo |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) after Thermal Decomposition |
| Compliance Standards | USEPA Method 7473, UOP 938-20, ASTM D6722-19, ASTM D7623-20, UOP 1009-15, ISO 15411 |
| Detection Limit | <0.01 ng Hg |
| Sample Form Compatibility | Solids and Liquids |
| Carrier Gas | Ambient Air (Self-Purified) |
| Sample Boat Material | Reusable Ceramic |
| Optical Source | Stabilized Hg Lamp (253.7 nm) |
| Detector Configuration | Dual Semiconductor Detectors (Measurement + Reference) |
| Dimensions & Weight | Compact footprint (~A3 size), 13 kg |
| Brand | Brookfield |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic (China) |
| Model | MA-3000 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Thermal Decomposition and Gold Amalgamation |
| Detection Limit | < 0.001 ng Hg |
| Dynamic Range | 0.001–70,000 ng Hg |
| Sample Throughput | 100-position Autosampler |
| Regulatory Compliance | ASTM D6722-19, ASTM D7623-20, UOP 1009-15, ISO 15411, US EPA Method 7473 |
| Patented Technology | JP No. 5596995 (Dual-cell, Triple-beam CVAAS Detector), JP No. 5001419 (Catalyzed Thermal Decomposition Tube) |
| Brand | Brooks Rand Labs |
|---|---|
| Origin | Imported |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | Methylmercury: 0.002 ng/L |
| Ethylmercury | 0.002 ng/L |
| Repeatability | RSD ≤ 3% at 25 pg |
| Linear Range | Methylmercury and Ethylmercury: 0.0125–50 ng/L |
| Quantification Range | 0–50 ng/L |
| Sample Throughput | Up to 72 positions via integrated autosampler |
| Brand | Brooks Rand Labs |
|---|---|
| Origin | USA |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | <8 pg absolute (equivalent to <0.3 ng/L in 25 mL sample) |
| Precision | RSD <1% at 100 pg |
| Linear Dynamic Range | 0–10,000 pg |
| Analysis Time | 1–2 minutes per sample |
| Compliance | Fully conforms to U.S. EPA Method 245.7 for total mercury determination |
| Sample Throughput | High-throughput parallel multi-channel operation |
| Upgrade Path | Compatible with integrated methylmercury (MeHg) speciation module using shared autosampler and detector |