Chemical Analysis Instruments
Filter
Showing 1771–1800 of 4548 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MiX5 Pro |
| Form Factor | Handheld / Portable |
| Application Scope | General-Purpose Metal & Alloy Analysis |
| Elemental Range | Mg (12) to U (92) |
| Detection Limits | Sub-ppm to % level (matrix-dependent) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Energy Resolution | ≤145 eV at Mn Kα |
| Repeatability | RSD < 1% for major elements (typical alloy matrix, ≥10 s measurement) |
| Operating Temperature | –10 °C to 50 °C |
| IP Rating | IP54 |
| Battery Life | Up to 12 hours (standard Li-ion pack) |
| Display | 5.5-inch capacitive touchscreen with sunlight-readable brightness |
| Connectivity | Wi-Fi 802.11 a/b/g/n, USB-C, optional integrated 5 MP macro camera |
| Software Compliance | Supports audit trail, user access control, and data export compliant with GLP/GMP documentation requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ONH5000 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Oxygen Range | 0.00001–3.0 wt% |
| Nitrogen Range | 0.00001–3.0 wt% |
| Hydrogen Range | 0.00000–0.25 wt% |
| Oxygen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Nitrogen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Hydrogen Precision | ±0.00002 wt% or RSD ≤ 2.0% |
| Sensitivity | 0.000001 wt% |
| Typical Analysis Time | 120–180 s (including purge, delay, and measurement) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ONH5000 |
| Power Supply | 8.0 kW Pulse Electrode Furnace |
| Max Furnace Temperature | >3500 °C |
| Detection Principles | Infrared Absorption (O), Thermal Conductivity (N, H) |
| Carrier Gases | He or N₂ |
| Compliance | ASTM E1019, ISO 14284, GB/T 11261–2022, GB/T 20123–2006 |
| Sample Form | Solid metallic & non-metallic materials |
| Measurement Elements | O, N, H (simultaneous or individual) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SP-3800 Series |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SupNIR-1000 |
| Instrument Type | Portable |
| Operating Principle | Grating Scanning |
| Wavelength Range | 600–1100 nm & 1000–1800 nm |
| Analysis Time | <30 s |
| Wavelength Repeatability | ±0.05 nm |
| Sampling Modes | Diffuse Reflectance & Transmission |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-1200 |
| Instrument Type | Portable |
| Operating Principle | Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | <1 second per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Compliance | CE, RoHS (as per manufacturer documentation) |
| Power Supply | Integrated rechargeable lithium-ion battery |
| Connectivity | Bluetooth 4.2 + Android mobile application |
| Brand | FPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SupNIR-1200 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-1500 |
| Instrument Type | Portable |
| Optical Principle | Holographic Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | >1 spectrum/sec |
| Spectral Resolution | 1 nm sampling interval |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Detector | TE-Cooled InGaAs |
| Chemometrics Software | RIMP |
| Power Supply | Integrated Rechargeable Battery |
| Display | Built-in LCD |
| Data Storage | Onboard Memory |
| Brand | FPI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SupNIR-1500 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | SupNIR-1520TM |
| Instrument Type | Portable |
| Optical Principle | Holographic Gold-Coated Concave Grating Scanning |
| Detection Mode | Diffuse Reflectance |
| Software | RIMP Chemometrics Platform |
| Compliance | Designed for ISO 17025-aligned textile testing workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Holographic Scanning Grating with TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm |
| Spectral Resolution | ≤ 8 nm (FWHM) |
| Wavelength Accuracy | ±0.2 nm |
| Data Sampling Interval | 1 nm |
| Scan Speed | Full-spectrum acquisition in < 60 s |
| Measurement Mode | Transmission |
| Chemometrics Software | RIMP v4.x (with PLS, PCR, SVM, and model validation modules) |
| Temperature Control | Integrated Peltier-based sample compartment (±0.1 °C stability) |
| Compliance | Meets ISO 12099:2017 for NIR instrument performance verification |
| Connectivity | Ethernet (RJ45), USB 2.0, optional Wi-Fi module |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Principle | Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Scan Speed | 0.2 s per spectrum |
| Spectral Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Principle | Holographic Grating Scanning |
| Wavelength Range | 1000–2500 nm |
| Spectral Acquisition Speed | 0.2 s per spectrum |
| Spectral Resolution | 1 nm data sampling interval |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Detector | Thermoelectrically Cooled (TEC) InGaAs Array |
| Sample Handling | Motorized Rotating Sample Tray |
| Built-in Reference Standards | Yes |
| Network Connectivity | Ethernet & USB |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | SupNIR-3000 |
| Instrument Type | Laboratory |
| Operating Principle | Grating Scanning |
| Wavelength Range | 1000–1800 nm |
| Scan Speed | >1 scan/s |
| Data Sampling Interval | 1 nm |
| Measurement Mode | Diffuse Reflectance |
| Chemometrics Software | RIMP |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Benchtop NIR Spectrometer |
| Optical Design | Holographic Digital Grating + TEC-Cooled InGaAs Detector |
| Wavelength Range | 1000–1800 nm (expandable to 1000–2500 nm) |
| Scanning Mechanism | Grating-Based Wavelength Scanning |
| Software Platform | RIMP Chemometrics Suite (Chinese UI) |
| Connectivity | Ethernet, USB, Remote Management via Web-Based Instrument Control Platform |
| Compliance Support | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready audit trail (via RIMP logging) |
| Brand | Frontier |
|---|---|
| Origin | Japan |
| Model | EGA/PY3030D |
| Pyrolyzer Type | Microfurnace-based Tubular Pyrolyzer |
| Temperature Range | 10 °C above ambient to 1050 °C (0.1 °C resolution) |
| Heating Rate | Programmable up to 600 °C/min (8-step temperature program) |
| Hold Time & Pyrolysis Time | 0.1–999.9 min (0.1 min step) |
| Cooling | Liquid nitrogen or liquid air |
| Interface Temperature Control (ITF) | 40–450 °C (1 °C step) |
| Reproducibility | RSD < 2% (GC-FID, certified per ASTM D7260 and ISO 17253) |
| Application Modes | EGA, TD, Single-shot Py, TD/PY Double-shot, Heart-cut Release Gas Analysis |
| Sample Introduction Options | Liquid injector, Dual-shot injector, Thermal Desorption (TD) module, Derivatization reactor, UV-assisted pyrolysis injector |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Online FTIR Spectrometer |
| Interferometer Design | Patented "Double Cat’s Eye" Alignment System |
| Detector | High-Sensitivity Sealed DLATGS |
| Spectral Resolution | Standard ≤ 4 cm⁻¹ (configurable to ≤ 0.5 cm⁻¹) |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Signal-to-Noise Ratio | ≥ 30,000:1 (at 4 cm⁻¹, 1 min scan) |
| Environmental Protection | Integrated Desiccant Monitoring & Auto-Alert for Optical Chamber Humidity |
| Software Compliance | GLP-Ready, FDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signature Support |
| Sample Compartment | Extra-Large Bore (≥ 180 mm Ø), Compatible with Pike Technologies ATR, DRIFTS, Gas Cells, Liquid Cells, and Microscope Modules |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector Options | FID, FPD |
| Control Interface | 7-inch TFT capacitive touchscreen |
| Gas Control | Mechanical valves with electronic pressure & flow monitoring |
| Column Oven | Dual-sensor temperature monitoring, thermal fuse protection, flame-retardant materials (UL94 V-0 rated) |
| Compliance | Designed to support GLP/GMP workflows, ASTM D3606/D1319, ISO 17025-aligned operation |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Control Architecture | Dual-AFC (Carrier Gas & Detector Auxiliary Gas) or Full-AFC Mode |
| Detection Systems | FID, FPD (Wide-Range Configurable) |
| Injection Options | Multiple Configurable Inlet Types |
| Software Platforms | FL97Plus, MyLab Chromatography Data Systems (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows with audit trail-ready CDS options |
| Human-Machine Interface | 7-inch capacitive touchscreen with real-time multi-channel status visualization |
| Maintenance Intelligence | Consumables tracking (septa, liner, split cold trap), usage-based alerts, and automated leak-check protocol |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FL1092C |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 150 positions (with optional extended sample tray) |
| Optional Modules | Integrated internal standard addition, programmable heating/stirring, barcode scanning, full-tray temperature control (via recirculating water bath) |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Model | FL1092T |
| Sample Capacity | 16 vials per tray |
| Configuration Options | Single-tower or dual-tower operation |
| Module Options | Vial agitation, temperature control (cooling/heating), barcode scanning |
| Compliance | Designed for integration with GC systems compliant with ISO/IEC 17025 laboratory practices and compatible with FDA 21 CFR Part 11–enabled data acquisition software |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 24-position or 91-position |
| Heated Positions | 12 independent temperature-controlled vial positions |
| Sampling Modes | Static and Dynamic (with optional trap enrichment) |
| Electronic Pneumatic Control | Advanced AFC/EPC (Analog Flow Control / Electronic Pressure Control) |
| Equipped with Vial Agitation | Yes, programmable orbital shaking |
| Software Interface | Integrated intelligent workstation with method sequencing, audit trail, and GC trigger synchronization |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose LC Analysis |
| Model | L75 |
| Pricing | Upon Request |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC5090Plus |
| Pricing | Upon Request |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Use |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LC5190 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical Instrument |
| Flow Rate Accuracy | ≤0.1% RSD |
| Pressure Range | Up to 60 MPa |
| Wavelength Range (UV Detector) | 190–900 nm |
| Injection Volume Precision | ±0.1 µL |
| Column Temperature Control Range | 5–85 °C (with cooling & heating) |
| Detection Modes Supported | UV-Vis, DAD, FL, ELSD, RI |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |