| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Mg to U |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability (RSD) | ≤0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Spot Size | Adjustable down to ~25 µm |
| Excitation Source | Rh anode microfocus X-ray tube |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Floor-Standing |
| Element Range | Mg–U |
| Detection Limit | 1 ppm |
| Quantitative Range | 0.0001–99.99 wt% |
| Energy Resolution | <140 eV at Mn Kα |
| Repeatability (RSD) | ≤0.1% |
| Detector | Silicon Drift Detector (SDD) |
| Excitation | Dual X-ray Tube Option with Up to 6 Automatic Filter Positions |
| Optics | Polycapillary Focusing Lens |
| Sample Stage | Motorized X-Y-Z with Turbo Drive |
| Imaging Mode | Real-time Elemental Mapping “On-the-Fly” |
| Vacuum Capability | Integrated Vacuum Chamber |
| Quantification Method | Fundamental Parameters (FP) Algorithm without Standards |
| Compliance | Fully Compatible with ISO 17025, ASTM E1621, and USP <233> for Elemental Impurities |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M4 TORNADO PLUS |
| Configuration | Benchtop |
| Element Range | C–U (Z = 6–92) |
| Energy Resolution | <140 eV |
| Detector | Dual Large-Area Silicon Drift Detectors (SDD) with Light-Element Windows |
| X-ray Source | Rh-target Microfocus Tube |
| Aperture Management System (AMS) | Integrated |
| Sample Compatibility | Flat & Topographically Irregular Surfaces |
| Compliance | ASTM E1598, ISO 22073, IEC 62471 (LED/X-ray Safety), GLP/GMP-Ready Data Audit Trail |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M4 TORNADO PLUS |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | C (Z=6) to Am (Z=95) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Compliance | CE, RoHS, IEC 61000-4 series |
| Safety | IEC 62471 (LED/X-ray emission), EN 61326-1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M6 JETSTREAM |
| Configuration | Benchtop/Floor-Standing |
| Application Field | Geological & Mineralogical Analysis |
| Elemental Range | Na (11) – U (92) |
| Quantification Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Sample Orientation | Vertical or Horizontal (motorized stage with collision avoidance) |
| Spot Size Adjustment | 5 discrete steps (25–400 µm) |
| Mobility | Modular disassembly into four transportable units |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | M6 JETSTREAM |
| Configuration | Benchtop/Floor-Standing |
| Application Type | General Purpose |
| Elemental Range | Na–U |
| Quantification Range | ppm to wt% |
| Energy Resolution | <140 eV |
| Detector | XFlash® Silicon Drift Detector (SDD) |
| Sample Orientation | Horizontal & Vertical |
| Spot Size Adjustment | 5-step variable microfocus |
| Safety | Integrated X-ray interlock & ultrasonic collision avoidance |
| Portability | Modular design—disassembles into four transportable components |
| Compliance | Designed per IEC 61000-6-3, IEC 61000-6-4, and EN 62471 for radiation safety and EMC |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ESR5000 |
| Instrument Type | Continuous-Wave (CW) ESR |
| Sensitivity | 50 pM spin detection limit (aqueous standard, DPPH) |
| Operating Frequency | X-band (~9.5 GHz) |
| Magnet System | Permanent magnet with temperature-stabilized gap |
| RF Bridge | Dielectric resonator-based |
| Software Platform | Windows-based ESR Studio v4.x |
| Optional Accessories | Liquid nitrogen variable-temperature unit (93–473 K), optical access window for in situ photolysis, motorized sample rotator, autosampler, flow cell, tissue cell |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX-F II |
| Instrument Type | Online FT-NIR Spectrometer |
| Measurement Principle | Fourier Transform (FT) Interferometry |
| Sampling Modes | Diffuse Reflectance, Transflectance, Liquid Transmission (with variable-pathlength fiber-optic probes) |
| Chemometrics Software | OPUS |
| Compliance | Designed for industrial process environments per IEC 61508 SIL2-ready architecture |
| Connectivity | Ethernet with support for OPC UA, Modbus TCP, and Profibus DP |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Quadrupole-TOF |
| Application Scope | Universal LC-MS/MS |
| Optional Features | ETD, HighMass Mode |
| Resolution (FSR) | >80,000 at full sensitivity |
| Mass Accuracy | <1 ppm RMS (calibrated, typical) |
| Mass Range | Up to 20,000 m/z (HighMass mode) |
| Isotopic Pattern Fidelity | True Isotopic Pattern (TIP) enabled |
| Software Platform | Compass DataAnalysis, Compass AutoPrep, SmartFormula™, SmartFormula 3D™ |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant workflows available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Metabolic Profiler™ |
| Instrument Type | High-Field Nuclear Magnetic Resonance Spectrometer |
| Sample Format | Solid-Liquid Dual-Mode Compatibility |
| Sensitivity | Not Specified |
| Resolution | Not Specified |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | microESR |
| Instrument Type | Pulsed ESR |
| Magnet System | Permanent Rare-Earth Magnet with Low-Power Electromagnetic Core |
| Resonator | High-Q Cylindrical TE₀₁₁ Cavity |
| Microwave Frequency | X-band (~9.5 GHz) |
| Sensitivity | <1 × 10⁹ spins/Gauss (for DPPH, 1 s acquisition) |
| Dimensions | 32 × 24 × 18 cm |
| Weight | 8.5 kg |
| Power Consumption | <30 W |
| Operating Temperature | 15–30 °C |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Time-of-Flight (TOF) |
| Configuration | Benchtop MALDI-TOF |
| Operating Modes | Linear & Reflectron |
| Resolution | Up to 15,000 (m/z 1,000–2,000, reflectron mode) |
| Laser | Nitrogen laser, 337 nm, adjustable repetition rate up to 60 Hz |
| Ion Source | microScout™ pulsed ion extraction source |
| Detector | Microchannel plate (MCP) |
| Vacuum System | Oil-free, maintenance-free turbomolecular pump with WhisperMode™ acoustic dampening |
| Sample Target | AnchorChip™ patterned stainless steel target |
| Software Platform | Compass Suite (including ProteinScape™, BioTools™, Polymerix™) |
| Regulatory Compliance Option | Compass Security Pack (21 CFR Part 11 compliant audit trail, electronic signatures, user access control) |
| Sample Throughput | High-speed automated acquisition enabled by precise AnchorChip™ spot positioning and integrated autoPSD (automated post-source decay) capability |
| Ionization Mode | Positive/Negative selectable |
| Mass Range | Broad dynamic range suitable for small molecules (e.g., lipids, additives), peptides, oligonucleotides, and synthetic polymers |
| Brand | Bruker |
|---|---|
| Origin | France |
| Instrument Type | Low-Field Time-Domain Nuclear Magnetic Resonance (TD-NMR) Analyzer |
| Sample Type | Liquid |
| Operating Frequency | 20 MHz |
| Sample Preparation | None required |
| Compliance | ASTM D 7171, ASTM D 4808, ASTM D 3701 |
| Brand | Bruker |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | minispec mq |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Type | Solid-Liquid Compatible |
| Operating Frequency | 20 MHz |
| Measurement Mode | Direct Analysis Without Sample Preparation |
| Temperature Range | –100 °C to +200 °C |
| Regulatory Compliance | 21 CFR Part 11, IQ/OQ/PQ Protocols, GLP-Compliant Operation |
| Calibration | Linear Calibration with ≥3 Samples, Chemometric Options Available |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Models | mq20, mq10 |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 60 positions |
| Minimum Injection Volume | 0.1 µL |
| Loop Volume | 100 µL |
| Positioning Accuracy | ±0.3 mm |
| Motion Axes | XYZ three-dimensional robotic arm |
| Needle Wash | Internal & external wall cleaning |
| Repeat Injection Capability | Unlimited |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| FT-IR Architecture | Interferometric (Michelson-type) |
| Wavenumber Range | 6000 – 670 cm⁻¹ |
| Detector | Thermoelectrically Cooled MCT (TE-MCT), No Liquid Nitrogen Required |
| Enclosure Rating | IP65 (Instrument Body), IP67 (Carrying Case) |
| Light Source | CenterGlow™ Broadband IR Source (Lifespan >5 years) |
| Interferometer | RockSolid™ Dynamic Alignment-Free Design (Lifespan >10 years) |
| Laser | Solid-State Diode Laser (Lifespan >10 years) |
| ATR Accessory | Heated Diamond Crystal |
| Power Supply | Integrated Rechargeable Lithium Battery (Field-Operable, Grid-Independent) |
| Software Platform | OPUS TOUCH™ (Touch-Optimized, Role-Based Workflow Interface) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MOVE-T |
| Instrument Type | Laboratory |
| Principle | Fourier Transform Near-Infrared (FT-NIR) |
| Design | Benchtop, Flow-Through Configuration |
| Sample Form | Liquid dairy matrices only |
| Compliance Context | Designed for routine QC in dairy processing per ISO 9622:2013, IDF 141:2000, and AOAC Official Method 972.16 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MPA III |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Near-Infrared Spectroscopy |
| Wavelength Range | 12500–3600 cm⁻¹ |
| Scan Speed | 8 scans/sec at 8 cm⁻¹ resolution |
| Data Sampling Interval | 2 cm⁻¹ |
| Sampling Modes | Diffuse Reflectance, Transmission, Diffuse Transmission, Fiber-Optic Probe |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MultiRAM |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 3600 – 50 cm⁻¹ |
| Spectral Resolution | < 0.5 cm⁻¹ |
| Detector Options | Room-temperature InGaAs (1× or 2×), Liquid-nitrogen-cooled Ge photodiode |
| Laser Source | Software-controlled Nd:YAG, 1064 nm |
| Interferometer | RockSolid™ permanent-alignment, gold-coated optics |
| Beam Splitter | Broadband quartz |
| Sample Chamber | Triple-side access, switchable 90° scattering geometry, defocusing optics |
| Standard Accessories | Motorized sample stage, integrated white-light source for response calibration, dual fiber-coupling ports, polarization control module |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Nanophoton RAMANtouch |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm (X), 500 nm (Y), 1 µm (Z) |
| Detection Method | Line-illumination + 2D CCD Acquisition |
| Imaging Speed | Full-spectrum mapping of >100,000 pixels in minutes |
| Automation Level | Fully motorized stage, autofocus, auto-alignment, auto-calibration |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanophoton RAMANwalk |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spatial Resolution | 350 nm in X and Y |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | TOF-TOF |
| Application Domain | Universal |
| Model | neofleX™ |
| Category | Biomass Spectrometer |
| Import Status | Imported |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | oIR3-s |
| Instrument Type | Laboratory-Based Fourier Transform Infrared Spectrometer |
| Wavenumber Range | 900–3600 cm⁻¹ |
| Spatial Resolution | <10 nm |
| Spectral Resolution | <1 cm⁻¹ |
| Acquisition Speed | 10 s per spectrum |
| Signal-to-Noise Ratio | 200:1 |
| Key | Brand: Bruker |
|---|---|
| Origin | Germany |
| Model | PepSep™ C18 |
| Type | Reversed-phase analytical column for nano/micro-flow LC-MS |
| Packing Material | Surface-modified silica with endcapping |
| Particle Size | 1.6 µm (typical for PepSep™ series) |
| Pore Size | 100 Å |
| Column ID | 75 µm × 25–50 cm (standard configurations) |
| Pressure Rating | ≤1000 bar |
| Compatible With | NanoLC, microLC, and timsTOF platforms (e.g., timsTOF Pro, timsTOF SCP) |
| Surface Chemistry | C18 bonded phase with low silanol activity |
| Batch-to-batch reproducibility | ≤3% RSD in retention time (n=5 injections, standard peptide mix) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Configuration | Dual Detector (PMT + CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 170–685 nm |
| Number of Analytical Channels | 32 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop |
| Excitation Source | Spark Discharge |
| Detector Configuration | Dual Detector (PMT + CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 170–685 nm |
| Number of Analytical Channels | 32 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q4 POLO |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–200 nm |
| Number of Channels | 128 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Q4 POLO |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–785 nm (dual optical paths: 130–785 nm total coverage) |
| Number of Channels | 128 |
| Optical System | MultiVision™ with argon-purged vacuum UV path |
| Temperature Compensation | AAC™ Active Ambient Compensation |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Q4 TASMAN |
| Instrument Type | Desktop |
| Excitation Method | Spark |
| Detector Type | Dual Detector (PMT + CCD) |
| Focal Length | 800 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 130–800 nm |
| Number of Channels | 128 |