Chemical Analysis Instruments
Filter
Showing 1801–1830 of 4548 results
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT800 |
| Instrument Type | Multifunctional Autosampler |
| Flow Control Precision | ±0.001 psi (EPC) |
| Sample Capacity | 96-position water/soil dual-mode autosampler |
| Trapping System | High-efficiency U-shaped trap with integrated spiral water removal |
| Sample Preservation | Optional refrigerated sample tray (4–10 °C) |
| System Inertness | Fully passivated flow path (inertized valves, tubing, and fittings) |
| Cleaning Protocol | Hot water and methanol purge cycles |
| Stirring | Integrated magnetic stirring for soil matrix enhancement |
| Software Interface | Modular workstation with guided workflow buttons |
| Compliance Support | Audit-trail ready |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | S900 GC-MSD |
| Pricing | Upon Request |
| GC Configuration | Conventional Capillary GC-MS |
| Brand | Fulu |
|---|---|
| Origin | Russia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TDA |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Sample Capacity | 50-position Auto-sampler |
| Sample Tube Format | US Standard Adsorption Tubes (89 mm × OD 6.4 mm) |
| Temperature Control Range | –20 °C to 450 °C |
| Cold Trap Heating Rate | Up to 3000 °C/min |
| Carrier Gas Control | Full Electronic Pressure Control (EPC) |
| System Liner | Fully Inert Flow Path |
| Peak Area Repeatability | RSD ≤ 2% |
| Operating Interface | Integrated Touchscreen Display |
| Functional Modes | Analysis, Tube Conditioning (Aging), Cold Trap Cleaning, Cold Trap Performance Test |
| Cooling Method | Thermoelectric (No Liquid Nitrogen Required) |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | BreathSpec® |
| Sample Introduction | 6-port valve direct injection |
| Sensitivity | sub-ppb (pptv–ppbv range) |
| Spectral Library | Volatile Organic Compounds (VOCs) |
| Ionization Source | ³H beta emitter (300 MBq, exempt per IEC 61017 & GB 18871-2002 Annex A) |
| Drift Voltage Polarity | Switchable positive/negative mode |
| Detection Principle | Coupled Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Data Acquisition | High-speed ADIO board with X-scale real-time processing |
| Display | 6.4″ TFT VGA screen |
| Connectivity | RS232 / USB-A ×2 / Ethernet (RJ45) |
| Power Input | 100–240 V AC, 50–60 Hz |
| Dimensions | 449 × 375 × 177 mm (W × D × H) |
| Weight | 15.5 kg |
| Enclosure | 19″ rack-mountable chassis, IP20 rated, EMC compliant |
| Cooling | Thermally regulated axial fan (max. 5.5 m³/h) |
| Gas Fittings | 3 mm stainless steel Swagelok® for drift gas, sample inlet/outlet, carrier gas, and IMS exhaust |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | FlavourSpec® 25 |
| Sample Introduction | Headspace Auto-sampling |
| Sensitivity | Sub-ppb (without preconcentration) |
| Spectral Output Formats | 2D ion mobility chromatograms, 3D retention time–drift time–intensity plots, and compound-specific fingerprint spectra |
| Brand | Kunyuan Instruments |
|---|---|
| Origin | Tianjin, China |
| Model | Gaia |
| Acceleration Voltage | ±10 kV |
| Sample Carousel Capacity | 21 filament positions (single/dual filament) |
| Mass Analyzer Type | Nier-Johnson geometry |
| Mass Dispersion | 560 mm |
| Magnetic Field Control | Hall-effect sensor with closed-loop feedback |
| Polarity Switching | Computer-controlled for positive/negative ion mode |
| Detector Configuration | Up to 16 Faraday cups + 4-channel discrete-dynode electron multiplier |
| RPQ Energy Filter | Optional |
| Preamp Capacity | Up to 32 units |
| Gain Range | 10¹⁰–10¹³ Ω selectable |
| Data Acquisition | 24-bit synchronized ADC, ppm-level precision |
| Dimensions (L×W×H) | 2160 × 1840 × 1810 mm |
| Power Supply | AC 220 V / 50 Hz, grounding resistance < 2 Ω |
| Cooling | Dedicated 500 W chiller for turbo pumps & magnet |
| Ambient Requirements | 18–24 °C, 40–60 % RH |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | GaiaField-V10 Lite |
| Price Range | USD 70,000–140,000 |
| Operating Principle | Push-broom |
| Imaging Modality | Computed Tomographic Imaging (CTI)-assisted Hyperspectral Data Acquisition |
| Deployment Mode | Ground-based & Airborne Compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm |
| Field of View (TFOV) | 22° |
| Instantaneous Field of View (IFOV) | 696 × 700 pixels (2× binning) |
| F-number | f/2.8 |
| Slit Size | 30 µm × 9.6 mm |
| Detector | CCD, 1392 × 1040 pixels (spatial × spectral) |
| Spectral Bands | 1040 (1×), 520 (2×), 256 (4×, default), 128 (8×) |
| Dynamic Range | 14-bit |
| Interface | USB 2.0 |
| Weight | 2.8 kg |
| Integrated Battery | 40 Wh (≥4 h continuous operation) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GaiaGeo |
| Pricing | Upon Request |
| Spectral Range | 970–2500 nm (400–970 nm optional) |
| Spectral Channels | 256 (continuous, at 970–2500 nm) |
| Spatial Resolution | 0.2–2 mm |
| Spatial Pixels per Line | 320 |
| Max Scan Speed | 100 lines/sec (e.g., 20 mm/sec at 0.2 mm pixel size |
| Data Format | BIL (ENVI-compatible) |
| Calibration | Factory spectral calibration |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | GaiaSky-mini |
| Price Range | USD 140,000 – 280,000 (based on ¥1–2M at 7.1 CNY/USD) |
| Operating Principle | Push-broom scanning |
| Imaging Mode | 3D spatial-spectral data cube |
| Platform | Airborne (rotor UAV-mounted) |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 3.5 nm (FWHM) |
| Spatial Resolution (detector) | 960 × 1040 pixels |
| Total Field of View (TFOV) | Configurable per lens option (17/18.5/23 mm) |
| Instantaneous Field of View (IFOV) | 0.16–0.23 m @ 300 m AGL |
| Frame Rate | Up to 160 line images/s (GaiaSky-mini2-VN, USB 3.0) |
| Optical Aperture | f/2.8 |
| Detector | Sony ICX674 CCD (GaiaSky-mini2-VN), 14-bit output |
| Pixel Pitch | 4.54 µm |
| Interface | USB 3.0 |
| Power Supply | 12–19 V DC |
| Power Consumption | 45 W |
| Weight | 1.5 kg (integrated camera + internal controller) |
| Onboard Storage | 240 GB SSD |
| Mounting Envelope | ≥330 × 200 × 260 mm (H×W×D, suspension height included) |
| Compatible Platforms | DJI Matrice 600 Pro, S1000+, and other stabilized rotor UAVs capable of hover-based acquisition |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Redox Colorimetric Titration |
| Wavelengths | 650 nm (test), 810 nm (reference) |
| Range | 0–1,000 ppm (customizable) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Analysis Cycle Time | 10 min |
| Sensitivity | 1% FS |
| Ambient Temperature | 20–60 °C (−4–140 °F) |
| Dimensions | 1016 mm H × 406 mm W × 241 mm D |
| Weight | 45.3 kg |
| Sample Interface | 1/4″ compression fitting |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Max Suspended Solids | <1,000 µm |
| Power Supply | 24 VDC or 90–240 VAC |
| Analog Outputs | up to eight isolated 4–20 mA (self-powered) |
| Digital Inputs | 8 dry/wet contacts (24 VDC) |
| Ethernet | Embedded GUI via Modbus TCP/IP |
| Serial Protocols | Modbus RTU over RS-232/RS-485 |
| Alarm Outputs | User-configurable relay outputs |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Corrosion Resistance | H₂S- and Cl₂-resistant housing |
| Flow Path Architecture | Modular, scalable to 6 independent sample streams |
| Control Architecture | Physically segregated electronics and wet chemistry modules |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Model | EIS Box |
| Instrument Type | Electrochemical Workstation |
| Channel Count | 8-channel multiplexer |
| Current Range | ±50 µA to ±5 A |
| Current Accuracy | ±25 pA ±0.2% of reading |
| Potential Accuracy | ±1 mV ±0.2% of reading |
| Potentiostatic Range | ±6 V |
| AC Impedance Frequency Range | 10 µHz – 100 kHz |
| Maximum AC Amplitude | 3 V (peak-to-peak) or 5 A (peak-to-peak) |
| Electrode Cable Length | 8 × 3 m four-terminal leads |
| Rack Mount | 19″ (48.3 cm), 3 U height |
| Interface | Ethernet or USB 2.0 |
| Operating System | Windows 10 only |
| Input Isolation | Fully floating, ground-referenced voltage limit ≤28 V |
| Weight | ~10 kg |
| Dimensions | 13.3 cm H × 41.5 cm W × 45.7 cm D |
| Power Supply | 100–240 VAC, 50–60 Hz, max. 120 W |
| Brand | Gamry |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Interface 1010E |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Dual Independent Potentiostatic Channels |
| Current Range | ±10 nA to ±1 A (9 decades) |
| Current Accuracy | ±5 pA ±0.3% of reading |
| Potential Accuracy | ±1 mV ±0.2% of reading |
| Potentiostatic Range | ±12 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 10 µHz – 2 MHz |
| Brand | Gangdong |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | F-180 |
| Wavelength Range (Excitation) | 200–800 nm (standard excitation filter: 365 nm) |
| Wavelength Range (Emission) | 200–900 nm |
| Spectral Bandwidth (EX/EM) | 10.0 nm |
| Resolution | ≤0.5 nm |
| Wavelength Accuracy | ±1.0 nm |
| Sensitivity (S/N) | >150:1 (water Raman peak) |
| Scan Speed | 30–30,000 nm/min (7 speeds) |
| Minimum Sample Volume | 0.5 mL (in 10 mm cuvette) |
| Excitation Source | 150 W imported high-intensity pulsed xenon lamp with ozone removal |
| Monochromator (EM) | Holographic concave grating, 1200 lines/mm |
| Excitation Filter | Precision narrowband interference filter |
| Slit Design | Fixed 10 nm spectral bandwidth |
| Detector | High-sensitivity PMT with gated optical shutter |
| Data Interface | USB 2.0 |
| Display | 320×240 blue OLED LCD |
| Power Supply | 220 V/50 Hz or 110 V/60 Hz |
| Dimensions & Weight | 600 × 450 × 335 mm |
| Brand | Huazhun Chromatography |
|---|---|
| Model | GC-2021plus |
| Origin | Jiangxi, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 5 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | ≤8 min (from 350 °C to 50 °C at 25 °C ambient) |
| Carrier Gas Flow Control Range | 0–200 mL/min (N₂), 0–1250 mL/min (H₂ or He) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (0–150 psi) |
| Injector Maximum Operating Temperature | 420 °C |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Argon Humidifier |
| Application | In-line humidification of argon carrier gas for ICP-OES/ICP-MS sample introduction systems |
| Compliance | Designed for integration with ISO/IEC 17025-compliant analytical workflows |
| Regulatory Context | Supports GLP/GMP-aligned sample introduction stability in high-salinity matrix analysis |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra1010 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2.0 nm (fixed) |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-Zero |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra2020 |
| Optical Design | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1200 nm |
| Spectral Bandwidth | Adjustable from 1.0 to 5.0 nm |
| Wavelength Accuracy | ±0.3 nm |
| Stray Light | <0.01% T at 220 nm and 340 nm |
| Automation | Motorized Wavelength Scanning & Auto-zeroing |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra3030 |
| Optical Design | Dual-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | Adjustable from 0.2 nm to 5.0 nm |
| Wavelength Accuracy | ±0.2 nm |
| Stray Light | <0.0005% T at 220 nm and 340 nm |
| Automation Level | Motorized wavelength scanning and slit control |
| Compliance | ASTM E275, ISO 6223, USP <857>, FDA 21 CFR Part 11 ready (with optional audit trail module) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | Cintra4040 |
| Optical Design | True Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Automation | Fully Automatic |
| Slit Width Range | 0.1–2.0 nm |
| Stray Light | <0.0005% T at 220 nm |
| Photometric Linearity | ±1.2% up to 5 Abs |
| Monochromator Configuration | Dual Littrow, Czerny-Turner |
| Dynamic Range | >6 Abs (measured) |
| Compliance | ASTM E275, ISO 6358, USP <857>, EP 2.2.25, JP 2.03 |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Emma |
| Price Range | USD 135,000 – 205,000 (FOB Australia) |
| Instrument Type | Powder X-ray Diffractometer |
| Power Consumption | <0.1 W (standby), <150 W (operational) |
| Beam Geometry | Variable parallel-beam and Bragg–Brentano focusing geometry |
| Sample Stage | Motorized variable-height powder stage + Eulerian cradle (χ, φ, ω rotation) |
| Detector Configuration | Dual fixed-position detectors — one parallel-beam detector with 0.4° Soller slit collimator, one focusing detector with variable slits and graphite monochromator |
| X-ray Source Optics | XOS polycapillary optic delivering 10 × 10 mm quasi-parallel beam |
| parallel-beam radius | 250 mm |
| focusing radius range | 175–250 mm |
| Optional Integrated Detection | Simultaneous XRD/XRF capability via integrated Si-PIN or SDD X-ray fluorescence detector |
| Portability | Modular chassis with integrated handles |
| Goniometer | Harmonic drive-based θ–2θ goniometer with <0.001° angular reproducibility |
| Radiation Safety | Lead-acrylic interlocked viewing window (large-format, wide-field), software-controlled actuation |
| Electronics | Industrial-grade FPGA-based control architecture with GLP-compliant event logging |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | enduro Z-1000 |
| Instrument Type | Graphite Furnace AAS |
| Optical System | Dual-beam |
| Monochromator | Plane Grating |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Zeeman Effect |
| Adjustable Magnetic Field Strength | 0.6–1.0 T (0.1 T increments) |
| Lamp Holder | 8-position Auto-aligning |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Hollow Cathode & Electrodeless Discharge Lamp Recognition | Encoded |
| Ultra-Lamp Power Supply | 10 V (1 standard, up to 4 optional) |
| Resolution | <0.2 nm |
| Sensitivity | ≤0.003 absorbance units for Cu at 324.8 nm |
| Detection Limit | ≤0.5 pg for Cd in graphite furnace mode |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | FS3000 |
| Sample Capacity | 10 calibration standards + 60 sample positions |
| Dedicated Vial Locations | rinse solution, blank solution, and recalibration standard |
| Programmable Parameters | measurement interval, pre-measurement delay, wash cycle duration, recalibration frequency, restandardization frequency, number of calibration standards, replicate count per sample, first/last sample position indexing |
| Distribution Status | Authorized International Distributor (Imported Equipment) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | HG3000 |
| Type | Continuous-flow hydride generation system for atomic absorption and atomic fluorescence spectroscopy |
| Compatible Elements | As, Sb, Bi, Ge, Pb, Se, Te, Sn, Hg (via cold vapor mode) |
| Detection Capability | Sub-ppb (ng/L) level for all supported elements |
| Sample Throughput | Up to 60 samples/h (triplicate readings) |
| Operating Principle | Acid–sodium borohydride (NaBH₄) reduction in laminar-flow segmented manifold |
| Compliance | Designed to meet ISO/IEC 17025 method validation requirements |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | HG3000PII |
| Type | Continuous-Flow Hydride Generation System |
| Sample Throughput | Up to 60 samples/h |
| Detection Capability | Sub-ppt for As, Bi, Sn, Sb, Te, Se, and Hg |
| Construction | Precision Borosilicate Glass Reaction Manifold |
| Flow Architecture | Segmented Gas-Liquid Flow with Integrated Phase Separation |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC 3000 |
| Pricing | Upon Request |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optimass 9500 |
| Instrument Type | Inductively Coupled Plasma Time-of-Flight Mass Spectrometer |
| Mass Resolution (Unit Mass Resolution at m/z = 238) | 2000 |
| Detection Limit | 1–10 ng·L⁻¹ (ppt level, 3–5 s integration time) |
| Sensitivity | Mcps per ppm |
| Mass Range | 1–260 amu (full-spectrum acquisition) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Optimass 9600 |
| Price Range | USD 420,000 – 700,000 (FOB) |
| Instrument Type | Time-of-Flight Mass Spectrometer (ICP-TOFMS) |
| Mass Resolution (FWHM at 1 amu) | >4000 |
| Detection Limit (in aqueous solution) | <0.1 pg/mL (ppt-level) |
| Sensitivity | >1 × 10⁶ cps per µg/L (Mcps/ppm) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | PS720 |
| Type | Automated Dilution Module for Atomic Absorption Spectroscopy |
| Integration | Designed exclusively for use with GBC SDS720 Autosampler and SavantAA Software |
| Control Interface | Fully integrated via SavantAA v5.0+ |
| Compatibility | Flame AAS (FAAS) and Hydride Generation AAS (HGAAS) |
| Automation Scope | Full dilution, standard addition, internal standard recovery, and up to two chemical modifier additions |
| Mechanical Integration | Synchronized with GBC’s motorized burner head rotation system for extended linear dynamic range |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quantima / Integra |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit (Cu) | 0.7 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (RSD) | ≤1.0% |
| Wavelength Range | 160–800 nm |
| Optical Resolution | 0.006 nm (160–200 nm) |
| RF Generator Frequency | 40.68 MHz |
| Argon Consumption (aqueous samples) | <11 L/min |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | SavantAA |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Double-Beam |
| Detector | Photomultiplier Tube (PMT) |
| Background Correction | Deuterium Lamp |
| Resolution | 0.1 nm |
| Sensitivity | >0.9 Abs for 5 mg/L Cu solution |
| Repeatability (RSD) | 0.45% |
| Detection Limit | ≤0.003 ppm for Cu |
| Lamp Holder | 8-position Automatic with Auto-Alignment |
| Wavelength Selection | Automatic |
| Slit Width | 0.1–2.0 nm (0.1 nm increments) |
| Slit Height | Adjustable (Standard & Reduced) |
| Gas Control | Fully Automated with Safety Interlocks |
| D₂ Lamp Lifetime | Up to 10× Longer Than Conventional Lamps |
| Lamp Identification | Encoded HCL & EDL Recognition (Standard on SavantAA Σ, Optional on SavantAA) |
| EDL Power Supply | 10 V Optimized Design (1 Standard on SavantAA & SavantAA Si |