Chemical Analysis Instruments
Filter
Showing 1921–1950 of 10669 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 TIGER (3rd Generation) |
| Instrument Type | Floor-standing WDXRF Spectrometer |
| X-ray Tube Power | 3 kW / 4 kW |
| Analyzable Elements | Be to Am |
| Configuration | Simultaneous/Sequential Multi-channel |
| Detector System | HighSense™ XE + SensorBoost™ Signal Processing |
| Operating Voltage Range | 20–60 kV |
| Sample Capacity | 84-position EasyLoad™ Autoloader with AI Vision |
| Vacuum System | Dual-chamber sealed vacuum with high-transmission beryllium window |
| Crystal Options | 8-position analyzing crystal changer |
| Collimator Options | 4-position collimator changer |
| Filter Options | 10-position filter changer |
| Aperture Mask Options | 5-position mask changer |
| Detectors | Flow-proportional counter & scintillation counter |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometry) |
| Model | scimaX™ |
| Resolution | R > 20,000,000 (at m/z 400) |
| Cooling System | Helium-gas-cooled Maxwell™ superconducting magnet (cryogen-free) |
| Ion Sources | Dual ESI/MALDI with automated switching |
| Fragmentation Modes | ECD, EID, ETD, CID, EDD, SORI-CID, MALDI-ISD, NETD |
| Acquisition Mode | CASI (Collision-Activated Selective Ion accumulation) |
| Application Scope | Universal — petroleumomics, phenomics, metabolomics, native proteomics, label-free MSI, fragment-based drug discovery |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SENTERRA II |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 50–4400 cm⁻¹ |
| Spectral Resolution | 1.5 cm⁻¹/pixel |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | 0.06 cm⁻¹ |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 CMOS |
| Price | USD 280,000 (FOB Hamburg) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | solariX |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometer) |
| Magnetic Field Strength Options | 7T, 12T, 15T |
| Ionization Modes | ESI and MALDI (dual-source configurable) |
| Detection Technology | ParaCell detector with AMP (Absorption Mode Processing) |
| Software Platform | Bruker Compass suite including SmartFormula |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TANGO |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 11,500–4,000 cm⁻¹ |
| Scan Speed | 8 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR Spectrometer |
| Model | Tensor 27 |
| Instrument Category | Fourier Transform Infrared Spectrometer |
| Condition | Professionally Refurbished |
| Compliance | Meets ISO/IEC 17025 calibration traceability standards for used analytical instrumentation |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Model | timsMetabo™ |
| Application Scope | Universal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer |
| Model | timsOmni |
| Application Scope | Universal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | timsTOF fleX™ |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Universal Platform for Spatial Omics and Molecular Imaging |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsTOF HT |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Technology | Parallel Accumulation–Serial Fragmentation (PASEF®), CCS-enabled 4D-Proteomics |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF MS) |
| Ionization Modes | Dual MALDI/ESI |
| Application Focus | Label-free Ultra-High-Throughput Screening (uHTS) in Drug Discovery |
| Software Platform | MALDI PharmaPulse® 2023 |
| Compliance Ready | GLP/GMP-aligned data handling, 21 CFR Part 11–compatible audit trail (via optional software configuration) |
| Throughput | Up to 3 samples/sec on 1536-well plates |
| CCS Calibration | Yes, with internal standards |
| MALDI Source | 10 kHz smartbeam™ 3D laser, MALDI-2 option available |
| Sample Handling | Robotic MALDI target auto-loader, disposable targets (96–1536-well compatible) |
| Data Export | Native support for Genedata Screener®, Assay Explorer, and other HTS informatics platforms |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | timsTOF Pro 2 |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Domain | Specialized Omics Research (Proteomics, Lipidomics, Phosphoproteomics, Clinical Biomarker Discovery) |
| Regulatory Context | Compliant with GLP/GMP data integrity requirements |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry–Time-of-Flight Mass Spectrometer (TIMS-TOF) |
| Model | timsTOF SCP |
| Application Domain | Specialized Single-Cell Proteomics, Immunopeptidomics, PTM Analysis, Epigenoproteomics |
| Ion Source | Optimized Dual-Orthogonal Reflectron Ion Source with 1-mm Transfer Capillary |
| Vacuum Architecture | 8-stage Differential Vacuum System |
| Acquisition Mode | dia-PASEF® (Data-Independent Acquisition Parallel Accumulation–Serial Fragmentation) |
| CCS Capability | Yes, Collision Cross Section–enabled Ion Mobility Separation |
| Scan Speed | >120 Hz MS/MS |
| Software Platform | timsControl, PaSER (Real-time Parallel Database Search Engine), Compatible with MaxQuant/Perseus, PEAKS Studio |
| Data Format | Open .d Format (Bruker) |
| Regulatory Compliance | Supports 21 CFR Part 11–compliant workflows (audit trail, electronic signatures, data integrity controls) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | timsUltra AIP |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Specialized Proteomics & Multi-Omics Platforms |
| Software Integration | TIMS PASEF®, TIMScore™, DIA-NN 4D-Proteomics™, Spectronaut® 20, ICC 2.0 |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | TRACER 5 |
| Application | Handheld / Portable |
| Industry Use | General-Purpose |
| Elemental Range | F to U |
| Quantification Range | ppm to wt% |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | TRACER 5g |
| Application | Handheld/Portable |
| Instrument Type | General-Purpose Research-Grade ED-XRF |
| Industry-Specific Use | Geoscience & Mineral Exploration |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) with 1 µm Graphene Window |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tracer 5i |
| Application | Handheld/Portable |
| Industry Type | General-Purpose |
| Elemental Range | Na (11) – U (92), down to F (9) under vacuum/He flush |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <140 eV (at Mn Kα) |
| Repeatability | 0.1% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Type | Total Reflection X-ray Fluorescence (TXRF) Spectrometer |
| Model | Blood Heavy Metal Analyzer |
| Element Range | Al (13) to U (92) |
| Detection Limit | 2 pg |
| Sample Volume (Liquid/Suspension) | 1–50 µL |
| Sample Mass (Powder) | <10 µg |
| Detector | 4th-Generation XFlash® SDD Silicon Drift Detector |
| Cooling | Peltier (No Liquid Nitrogen Required) |
| Energy Resolution | <160 eV at Mn Kα (100 kcps) |
| Automation Options | 1-position or 25-position Auto-sampler |
| Compliance | ASTM D7782, ISO 17294-2, USP <232>/<233>, GLP/GMP-ready data integrity features |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ultrafleXtreme |
| Instrument Type | TOF-TOF |
| Application Domain | Universal |
| Category | Biomass Spectrometer |
| Distribution Status | Authorized Distributor (Imported) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX 70v |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 10–30,000 cm⁻¹ |
| Spectral Resolution | ≤0.4 cm⁻¹ (standard), upgradable to 0.16 cm⁻¹ |
| Scan Speed | 80 scans/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Interferometer | RockSolid™ permanently aligned, gold-coated optics |
| Vacuum Capability | Full-vacuum optical bench optional |
| Beam Splitter Exchange | Motorized BMS-c unit supports up to 4 beam splitters without breaking vacuum |
| Detector Compatibility | Up to 5 software-controlled detectors (RT, LN₂-cooled, LHe-cooled) |
| Compliance | ASTM E1421, ISO 17025, USP <851>, FDA 21 CFR Part 11 (with OPUS software suite) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX 80 / VERTEX 80v |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 50000–5 cm⁻¹ |
| Spectral Resolution | < 0.06 cm⁻¹ |
| Scan Speed | 115 scans/sec |
| Signal-to-Noise Ratio | 55,000:1 |
| Interferometer | UltraScan™ True-Alignment Patent Interferometer |
| Optical Platform | Fully Vacuum-Compatible Cast-Aluminum Base (VERTEX 80v) |
| Data Acquisition | DigiTect™ Digital Detection Technology |
| Beam Splitter Exchange | Automated, Vacuum-Compatible BMS-c |
| Detector Channels | Dual-Channel, 24-bit High-Speed ADC |
| Light Sources | Integrated Air-Cooled Source + Optional External Water-Cooled High-Power Source |
| Beam Ports | 5 Output Ports + 2 Input Ports |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | VERTEX NEO R |
| Instrument Type | Laboratory FTIR Spectrometer |
| Vacuum Capability | Full Vacuum Optical Bench |
| Interferometer | RockSolid™ Permanent Alignment |
| Detector Technology | MultiTect™ Multi-Element Detector Platform |
| Instrument Class | Research-Grade FTIR |
| Compliance | Designed for ASTM E1421, ISO 17025-compliant laboratories, GLP/GMP-ready configuration options |
| Software | OPUS 8.5 with FDA 21 CFR Part 11–compliant audit trail and electronic signature modules |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Laboratory FTIR |
| Model | VERTEX NEO Ultra |
| Spectral Resolution | 0.04 cm⁻¹ |
| Vacuum Operation | Yes |
| Detector Configuration | Up to 6 integrated detectors (MultiTect) |
| Beam Path Environment | Fully evacuated optical bench |
| ATR Capability | Vacuum-compatible attenuated total reflection module |
| Scan Modes | Step-scan (μs–ns–ms dynamics), Rapid-scan |
| Interferometer | UltraScan with linear air-bearing mirror drive |
| THz Extension | verTera module compatible |
| Optical Path Flexibility | 5 output ports, 4 beam splitters, 4 sources, 6 detectors — all switchable under vacuum |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XMS |
| Form Factor | Benchtop / Floor-Standing |
| Application Type | General-Purpose |
| Elemental Range | Mg (Z=12) to U (Z=92) |
| Quantitative Range | 1 ppm – 99.99 wt% |
| Energy Resolution | <140 eV (at Mn Kα, −20 °C) |
| Repeatability | ≤0.1% RSD (for major elements under controlled conditions) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Powder X-ray Diffractometer |
| Model | JV QC3 |
| Application Focus | Compound Semiconductor Epitaxial Layer & Substrate QC |
| Automation Level | Fully Automated Wafer Handling (Optional Robotic Arm) |
| Sample Capacity | Up to 4 × 100 mm wafers per batch |
| Compliance | Designed for ISO/IEC 17025-aligned semiconductor manufacturing environments |
| Software Platform | Bruker JV-RADS (Bede RADS) with automated peak fitting, strain/relaxation quantification, and multi-layer compositional analysis |
| X-ray Source Protection | XRG Protect™ tube longevity technology |
| Power Mode | Eco-standby with reduced idle power consumption |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BSD-MASS |
| Quadrupole Mass Analyzer | INFICON (USA-manufactured, with Certificate of Origin & Factory Calibration Report) |
| Mass Range | Standard 1–100 amu |
| Filament | Dual Iridium-coated filaments (active/standby, software-switchable) |
| Resolution | <0.5 ppm at 40 amu |
| Scan Speed | Up to 1.8 ms/amu, step size 0.1 amu |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹⁵ Torr (4 s dwell time) |
| Sample Flow Rate | Standard down to 2 SCCM |
| Response Time | <1 s at ≤2 SCCM flow |
| Precision Splitting System | Integrated high-accuracy flow splitter |
| Soft Ionization | Electron energy digitally adjustable (0–100 eV) |
| Turbo Molecular Pump | Edwards, 85 L/s, 100,000 RPM, base pressure 1 × 10⁻¹² mbar |
| Dry Scroll Pump | 20 L/s, base pressure 1 × 10⁻¹ mbar |
| Vacuum Chamber | Monolithic, weld-free heated chamber (bakeable to 150 °C) |
| Inlet Interface | 1.2 m passivated stainless steel capillary (anti-condensation & anti-clogging design) |
| Software | INFICON OEM platform (English), TCP/IP communication |
| Dimensions | 510 mm (H) × 520 mm (L) × 225 mm (W), Weight: 30 kg |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2100 W |
| Dimensions (L×W×H) | 320 × 400 × 730 mm |
| Weight | 23 kg |
| Electrical Supply | 220–240 VAC ±10%, 50/60 Hz |
| Safety Certifications | CE, CSA |
| Repeatability | RSD <0.8% |
| Nitrogen Detection Range | 0.02–220 mg N |
| Cooling Water Management | Intelligent Flow Control with Auto-Shutoff |
| Steam Power Control | Adjustable 10–100%, Programmable Steam Gradient |
| Safety Systems | Dual-flow cooling water sensor, steam generator pressure monitoring, sample tube presence detection, transparent safety shield with interlock, reagent/waste/water level sensing |
| Voltage Stabilization | Integrated line regulator for consistent steam output |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Automated Kjeldahl Nitrogen Determinator |
| Model | K-375 |
| Nitrogen Range | 0.02–200 mg N |
| Distillation Time | 1–9999 min (typical: 4 min/sample) |
| Repeatability | RSD ≤ 1% |
| Sample Weight Capacity | ≤ 5 g (solid), ≤ 200 mL (liquid) |
| Nitrogen Recovery Rate | ≥ 99.5% |
| Max Power Consumption | 2.4 kW |
| Dimensions (L×W×H) | 458 × 670 × 431 mm |
