Chemical Analysis Instruments
Filter
Showing 181–210 of 4194 results
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-2900P II |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 1–100 mL/min |
| Maximum Operating Pressure | 20 MPa |
| UV-Vis Wavelength Range | 200–800 nm |
| Touchscreen Interface | 12-inch Capacitive Display |
| Autosampler Volume Range | 1–20 mL |
| Fraction Collection Modes | Peak-based, Full-run, Manual, Time/UV Window-triggered |
| Compatible Collection Vessels | 15 mm, 18 mm, 25 mm ID tubes and custom containers |
| Pump Configuration | Dual High-Precision Plunger Pumps |
| Gradient Mixing Accuracy | ≤0.5% RSD |
| Column Compatibility | Static HPLC prep columns (10–50 mm ID) |
| Software | Dedicated preparative chromatography control suite with user permission hierarchy and 21 CFR Part 11-compliant audit trail |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Model | OCTOPUS |
| Application Level | Laboratory-grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤2% |
| Maximum Pressure | 20 MPa |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 1 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU |
| Data Acquisition Frequency | Not Specified |
| Gradient Configuration | Binary or Quaternary Pump Options |
| Compatible Detectors | PDA, ELSD, RI |
| Automation Features | Auto-sampler, Column Switcher, Intelligent Fraction Collector with Vial Rack ID Recognition and Solvent/Waste Level Sensing |
| Column Compatibility | Flash cartridges, medium-pressure glass columns, high-pressure stainless-steel columns |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | Multiple Catalog Numbers |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Refractive Index Detector (RID) |
| Flow Rate Range | 1–50 mL/min |
| Flow Cell Volume | 7 µL |
| Temperature Control Range | 35–55 °C (adjustable in 1 °C increments |
| Flow Cell Pressure Rating | 6 kg/cm² |
| Internal Cell Dead Volume | 88 µL or 353 µL (selectable) |
| Linear Range | 0–2000 µRIU |
| Noise Level | ≤10 × 10⁻⁸ RIU |
| Drift (Full-Scale) | <1 mV/hour with 1 mL/min H₂O flow |
| Auto-Zero Function | Yes |
| Integrated Flush Valve | Yes |
| Digital Interface | RS-232 (bidirectional parameter transmission) |
| Brand | Agela |
|---|---|
| Model | ZAM4000 |
| Detection Principle | Evaporative Light Scattering |
| Flow Rate Range | 1–50 mL/min |
| Nebulizing Gas Pressure | 3.5–5 bar |
| Nebulizing Gas Flow Rate | 1.7 L/min |
| Auxiliary Drying Gas Flow Rate | <2 m/min |
| Evaporator Temperature Range | Ambient to 85 °C |
| Light Source | Tungsten Lamp |
| Detector | Photomultiplier Tube (PMT) |
| Output Signal | 0–5 V Analog + RS-232 Digital |
| Power-Saving Mode | Enables independent shutdown of gas, lamp, heater, and PMT |
| Fault Monitoring | Real-time diagnostics for gas flow, heater, lamp, and PMT failure |
| 雾化气流控制 | Integrated electronic pressure controller for nebulizer gas |
| Auxiliary drying gas control | Built-in controller |
| Brand | Agena Bioscience |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MassARRAY Nucleic Acid Mass Spectrometer |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Application Scope | General-Purpose Biomolecular Analysis |
| Resolution | >750 across full detection range |
| Sensitivity | ≥5% for routine somatic mutation detection |
| Stability | Measurement deviation ≤ ±5% |
| Throughput | ≤15 minutes for 96 samples |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Third-Party Service Provider |
| Product Category | Imported Instrumentation |
| Model | Agilent 1100/1200/1360 HPLC 3Q Qualification Package |
| Price Range | USD 11,000–20,500 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical Use |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Flow Accuracy | < ±0.1% RSD |
| Injection Volume Range | 1–50 µL |
| Autosampler Tray Capacity | 100 positions |
| Column Oven Temperature Range | 10–60 °C |
| UV-Vis Detector Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent |
|---|---|
| Model | 1120 |
| Type | Compact Liquid Chromatograph (HPLC) |
| Pump Flow Rate Range | 0.001–10.0 mL/min (0.001 mL/min increments) |
| Flow Precision | ≤0.07% RSD |
| Autosampler Injection Volume | 0.1–100 µL (0.1 µL increments) |
| Injection Precision | <0.25% RSD (5–100 µL), <1% RSD (1–5 µL) |
| Sample Capacity | 100 × 2 mL vials or 2 × 40-position half-trays or 15 × 6 mL vials |
| Column Oven Temperature Range | 10 °C above ambient to 60 °C |
| Temperature Stability | ±0.15 °C |
| VWD Wavelength Range | 190–600 nm |
| VWD Noise | ±0.75 × 10⁻⁵ AU |
| Detector Compatibility | RID, FLD, ELSD |
| Software | EZChrom Elite Compact (English/Chinese/Japanese UI), LMD predictive diagnostics |
| Regulatory Support | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compliant operation |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1200 |
| Quotation | Upon Request |
| Instrument Type | Triple Quadrupole |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1220 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.2–10 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1220 Infinity II |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical use in QA/QC and research laboratories |
| Flow Range | 0.2–10 mL/min |
| Injection Volume Range | 0.1–100 µL |
| Width | 370 mm |
| Pump Configuration | Isocratic or Binary Gradient Pump (optional Quaternary configuration) |
| Maximum Number of Temperature-Controlled Zones | 1 (with optional column oven) |
| Maximum Solvent Channels | 4 (with Solvent Selection Valve, SSV) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Column Oven Compatibility | Yes (optional) |
| Detector Options | Variable Wavelength Detector (VWD), Diode Array Detector (DAD), Refractive Index (RID), Fluorescence (FLD), Evaporative Light Scattering (ELSD), Mass Selective Detector (MSD) |
| Software Platforms | OpenLab CDS (ChemStation Edition, EZChrom Edition, or modern OpenLab CDS workstation) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Sustainability Certification | My Green Lab ACT Label (verified lifecycle environmental impact assessment) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity II Analytical-Scale Purification |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.05–5 mL/min (with G7112B Pump) |
| Maximum Operating Pressure | 600 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1260 Infinity II Bio-Inert |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | Universal for Biomolecular Analysis |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Pressure | up to 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Bio-SEC |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Biopharmaceutical Characterization |
| Flow Rate Range | Up to 10 mL/min (with G5654A Pump Module) |
| Injection Volume Range | 0.1–100 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Model | 1260 Infinity II |
| Configuration | Ambient-Temperature Gel Permeation Chromatography System with Optional RI, Viscometry, and Multi-Angle Light Scattering (MALS) Detection |
| Software Platform | Agilent GPC/SEC Software (v4.x or later) |
| Compliance | Designed for GLP/GMP environments |
| Detector Compatibility | Refractive Index (RI), Differential Viscometer, MALS (via optional interface module) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity II GPC/SEC |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Polymer Characterization |
| Flow Rate Range | Up to 10 mL/min (G7110B Pump Module) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Temperature Control | Dual-Zone Column Compartment (G7116A/B) |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II High-Temperature GPC |
| Instrument Type | High-Temperature Gel Permeation Chromatography (GPC) / Size Exclusion Chromatography (SEC) System |
| Pump Flow Range | Up to 10 mL/min (with G7110B high-temperature pump module) |
| Pump Pressure Rating | Up to 600 bar |
| Column Oven Temperature Range | Ambient to 220 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Manual Preparative |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 1–50 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 1260 Infinity II |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-purpose QC/QA, R&D, and routine analytical laboratories |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Pressure | 600 bar |
| Flow Precision | ≤0.07% RSD |
| Injection Volume Range | 0–100 µL |
| Sample Tray Capacity | 100 positions (expandable to 6144 via microtiter plates) |
| Column Oven Temperature Range | 4–80 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 80 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Multi-Detector GPC/SEC |
| Instrument Type | Ambient-Temperature GPC/SEC System |
| Column Oven & Detector Temperature Range | Independent temperature control per detector, 30–60 °C |
| Maximum Number of Temperature Zones | 2 (G7116A/B Dual-Zone Module) |
| Integrated Column Oven with Autosampler | Single-Zone Configuration |
| Pressure Operating Range | Up to 600 bar |
| Flow Cell Volume (Light Scattering Detector) | 10 µL |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1260 Infinity II MDS |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative LC/MSD |
| Application Level | Laboratory-Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 1–50 mL/min |
| Maximum Operating Pressure | 20–420 bar |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity II Preparative |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.01–50 mL/min |
| Flow Accuracy | ≤0.3% RSD |
| Flow Precision | ≤0.3% RSD |
| Maximum Pressure | 420 bar |
| Wavelength Range | 190–700 nm (0.1 nm resolution) |
| Baseline Noise | 2.5 µAU at 254 nm, 1 s time constant |
| Data Acquisition Rate | 120 Hz |
| Injection Volume Range | 0.1–5000 µL |
| Fraction Capacity | Up to 648 tubes (with optional fraction collector upgrade) |
| System Dead Volume | Minimized via integrated delay sensor calibration |
| Solvent Channels | 2 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W × D × H) | 941 × 462 × 640 mm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 1260 Infinity III Amino Acid Analysis System |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-purpose amino acid analysis |
| Flow Rate Range | Up to 10 mL/min (G7111B pump module) |
| Maximum Operating Pressure | 600 bar |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 5 °C above ambient to 80 °C |
| Solvent Reservoir Capacity | 4 channels |
| Power Supply | 100–240 VAC |
| Dimensions (W × D × H) | 396 × 468 × 560 mm |
| Column ID Reader | Optional |
| Smart System Emulation | Not supported |
| ACT Certification | My Green Lab ACT certified for environmental accountability, consistency, and transparency |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity III Analytical-Scale LC |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.05–5 mL/min (with G7112B pump), 0.2–10 mL/min (with G7110B/G7111A/G7111B pumps) |
| Maximum Operating Pressure | 600 bar |
| Column ID Reader | Optional |
| Solvent Reservoir Capacity | Up to 15 channels (with optional Solvent Selection Valve) |
| Fraction Collection Capacity | Up to 384 fractions (4 × 96-well microplates) or 216 tubes (glass, 4 tube OD sizes) |
| Injection Volume Range | 0.1–100 µL (standard), up to 1800 µL (with Multi-Draw Kit) |
| Column Temperature Zones | 2 (with G7116A/B), 1 (with Vial Sampler + Integrated Column Compartment) |
| Detector Compatibility | UV/Vis, RI, FL, ELSD, Single-Quadrupole LC/MSD |
| Software Platform | Agilent OpenLab CDS ChemStation |
| Delay Volume Sensor | Integrated, auto-calibrating |
| System Dimensions (W × D) | 980 × 468 mm |
| Power Supply | 100–240 VAC |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 1260 Infinity III Bio-Inert Analytical LC System |
| Maximum Operating Pressure | up to 600 bar |
| Flow Path Material | Metal-Free (Titanium, PEEK, Sapphire, Ceramic) |
| pH Range | 1–13 (short-term exposure to pH 14) |
| Salt Tolerance | up to 2 mol/L NaCl |
| Residual Carryover | <9 ppm |
| Fraction Collection Capacity | up to 384 wells (4 × 96-well plates) or 216 tubes (4 tube diameters) |
| Detection Options | Bio-inert UV and Fluorescence Flow Cells |
| Solvent Mixing | Quaternary Gradient Mixing with Active Seal Wash |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Origin Category | Imported |
| Model | 1260 Infinity III Bio-Inert LC System |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application | Universal for Biomolecular Analysis |
| Flow Rate Range | 0.2–10 mL/min |
| Maximum Operating Pressure | up to 600 bar |
| Injection Volume Range | 0.1–100 µL (0.1–1000 µL with Multi-Draw Kit, max 400 bar) |
| Solvent Channels | 4 (expandable to 15 with Solvent Selection Valve) |
| Column Temperature Zones | 2 (with G7116A) |
| Column ID Reader | Optional |
| Column Capacity | 4 |
| pH Range | 1–13 (short-term exposure to pH 14) |
| Salt Tolerance | up to 2 mol/L NaCl |
| Residual Carryover | <9 ppm |
| Power Supply | 100–240 VAC |
| Dimensions (W × D) | 435 × 468 mm |
| ACT Certification | Yes (My Green Lab ACT Label) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Bio-Inert Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Operating Pressure | Up to 600 bar |
| Carryover | <9 ppm |
| Temperature Control Range (Optional) | 4–40 °C |
| Flow Path Materials | Ceramic needle, PEEK needle seat, stainless-steel-coated PEEK capillary |
| Intended Use | Research Use Only (RUO), Not for Diagnostic Purposes |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Diode Array Detector WR |
| Instrument Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–950 nm |
| Short-Term Noise | < ±7 µAU (ASTM compliant) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III ELSD |
| Detection Principle | Evaporative Light Scattering Detection |
| Compatible Systems | Agilent 1260 Infinity III LC, Other HPLC/UHPLC Platforms via Analog/Digital I/O |
| Operating Temperature Range | Up to 120 °C |
| Carrier Gas | Nitrogen or Compressed Air |
| Detection Sensitivity | Sub-nanogram (ng) Level for Non-Volatile and Semi-Volatile Analytes |
| Baseline Stability | Minimal Drift (<0.5 mV/h after equilibration) |
| Data Acquisition Rate | Up to 100 Hz |
| Reproducibility | RSD < 2% (n = 6, repeated injections) |
| Solvent Compatibility | Fully compatible with DMSO, THF, DMF, chlorinated solvents, and high-boiling-point mobile phases |
| Regulatory Compliance | Designed for GLP/GMP environments |