Chemical Analysis Instruments
Filter
Showing 2131–2160 of 4548 results
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Gas Flow Range | 0–5 L/min |
| Nebulizer Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–0.5 mL/min |
| Light Source (Standard) | 650 nm Laser |
| Detector | Imported Photomultiplier Tube (PMT) |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed Air or Nitrogen |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 195–650 nm (Excitation), 200–800 nm (Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Flow Rate Range | 0–10 mL/min |
| Flow Accuracy | ±0.3% |
| Flow Precision (RSD) | ≤0.1% |
| Injection Valve Pressure Rating | 35.0 MPa (5000 psi) |
| Spectral Bandwidth | 10 nm / 20 nm |
| AD Resolution | 24-bit |
| Software Platform | FStar-2000 Chromatography Data System (CDS) for Windows 7/8/10 |
| Compliance | Fully aligned with Chinese Pharmacopoeia (2015 Edition), GLP/GMP principles, and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-1000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates |
| Maximum Scanning Speed | 100 mm/s |
| Camera Resolution | 12 MP |
| Exposure Time Range | 0–10 s |
| Gain Adjustment | 0–100% |
| Imaging Modalities | Visible, UV, Fluorescence, Chemiluminescence |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodLook-2000 |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light (400–700 nm) |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC plates |
| Scanning Speed | Max 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GoodSee-20E |
| Instrument Type | TLC Imaging System |
| Imaging Wavelengths | 254 nm UV, 365 nm UV, Visible Light |
| Maximum Imaging Area | 200 × 200 mm |
| Camera Resolution | ≥12 MP |
| Power Supply | 220 V, 50 Hz, 90 W |
| Light Source Power | 30 W per channel |
| Scanning Speed | Up to 100 mm/s |
| Interface | USB |
| Software Platform | Windows 7 / 10 |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Optional Nitrogen Purge |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-3500Plus II |
| Instrument Type | TLC Densitometer & Imaging System |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence |
| Wavelength Range | 190–1000 nm |
| Light Sources | Tungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Option |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (Selectable |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (Fully Automated Control) |
| Sample Stage Capacity | 200 mm × 200 mm TLC Plate (Customizable to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL20E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation Wavelength Range | 190–800 nm |
| Emission Wavelength Range | 190–800 nm |
| Spectral Bandwidth Options | 2 / 5 / 10 / 20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Light Source | Solid-State Discharge Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Compliance | Meets GMP/GLP requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-FL30E |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | 150 W DC Xenon Lamp |
| Spectral Bandwidth | 10 nm / 15 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Software | FM-2000 Chromatography Workstation |
| Compliance | Chinese Pharmacopoeia (2010 & 2015 Editions), GLP/GMP-ready, LIMS-compatible, FDA 21 CFR Part 11 support (audit trail & electronic signature enabled) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL30Plus |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Spectral Bandwidth | 10 nm / 15 nm |
| Light Source | 150 W DC Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range | Ambient to 50 °C (Optional) |
| Compliance | Chinese Pharmacopoeia 2010/2015 Edition, GLP/GMP-Ready, LIMS-Compatible |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | KH-FL50E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelength Range | 190–900 nm |
| Detection Modes | Fluorescence, Phosphorescence, Chemiluminescence |
| Light Source | 150 W DC Xenon Lamp or 5 W Pulsed Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Spectral Bandwidth (Excitation & Emission) | 5/10/15/20 nm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| AD/DA Resolution | 24-bit |
| Flow Cell Temperature Control | 5–50 °C |
| Detector Options | Single-Photon Counting Module (SPCM) or Variable-Voltage High-Sensitivity PMT |
| Compliance | Chinese Pharmacopoeia 2010/2015, GLP/GMP-ready, LIMS-compatible |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PrepChromaster-7000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–250 mL/min (single pump), 0–500 mL/min (dual pump) |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.5% |
| Maximum Operating Pressure | 200 bar (standard), upgradable to 300 bar |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | PrepChromaster-8000 |
| Flow Rate Range | 0–200 mL/min (single pump), 0–400 mL/min (dual pump) |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | PuriMaster-2000 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1.0% |
| Maximum Pressure | 4000 PSI (27.6 MPa) |
| Wavelength Range | 190–850 nm (dual-wavelength simultaneous detection) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | ±3×10⁻⁵ AU (254 nm) |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PuriMaster-3000A |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0–250 mL/min (single pump), 0–500 mL/min (dual pump) |
| Flow Accuracy | RSD = 0.5% |
| Flow Precision | RSD = 1.0% |
| Maximum Pressure | 50 bar (standard) |
| Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection) |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | PuriMaster-5000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.5% |
| Maximum Pressure | 4000 PSI (27.6 MPa) |
| Wavelength Range | 190–850 nm (simultaneous quad-wavelength detection) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PuriMaster-7000 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–100 mL/min (customizable up to 200 mL/min) |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 1.0% |
| Maximum Pressure | 4000 psi (27.6 MPa) |
| Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Repeatability | ±0.4 nm |
| Baseline Noise | ≤3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Autosampler Capacity | 42 or 144 positions |
| Fraction Collector Capacity | 160 × 15 × 150 mm test tubes |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriSmart-100 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0–50.00 mL/min (per pump) |
| Maximum Operating Pressure | 30 MPa |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.1 mAU (at 254 nm) |
| Baseline Drift | 0.2 mAU/h (at 254 nm) |
| Detection Modes | Dual-Wavelength UV-VIS, Online UV-VIS Spectral Scanning |
| Gradient Capability | Binary, Low-Delay Mixing |
| Fraction Collection | X-Y Robotic Fraction Collector |
| Software Compliance | Audit Trail, User Management, Data Integrity per FDA 21 CFR Part 11 & GLP Principles |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriSmart-200 |
| Application Level | Laboratory-Scale R&D |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 0–100 mL/min |
| Flow Accuracy | ±1.5% |
| Pressure Range | 0–30 MPa |
| Pressure Pulsation | < ±0.2 MPa |
| Wavelength Range | 190–850 nm (dual-wavelength simultaneous detection) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ±0.1 mAU at 254 nm |
| Baseline Drift | 0.2 mAU/30 min at 254 nm |
| Sample Injection Volume | 5 mL (standard), customizable |
| Detector Light Source | Deuterium–Tungsten dual-lamp assembly |
| Monochromator | 1200-line/mm holographic grating |
| Fraction Collection | X-Y matrix-type collector |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ScalePuri-100 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | Medium-to-High Pressure Preparative LC |
| Flow Rate Range | 0–100 mL/min (pump), up to 800 mL/min (gradient mixing) |
| Flow Accuracy | RSD = 0.5% |
| Flow Precision | RSD = 1% |
| Max Operating Pressure | 150 bar |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 3 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Detection Mode | UV-VIS with Quad-Wavelength Real-Time Monitoring |
| Column Compatibility | Axial Compression Columns, 50–100 mm ID |
| Prep Capacity | Gram-scale (up to 100 g per run) |
| System Control | Fully Software-Driven with Audit Trail, User Management, and Electronic Signature Support |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ScalePuri-150 |
| Application Level | Laboratory & Pilot-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0.01–1000 mL/min |
| Flow Accuracy | ±2.0% |
| Flow Precision | ±1.5% (injector pump) |
| Maximum Pressure | 10 MPa (100 bar) |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | ±0.1 mAU @ 254 nm |
| Baseline Drift | 0.2 mAU/30 min @ 254 nm |
| Data Acquisition Rate | Not specified |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A1 / 2DMax1100P1 |
| Flow Rate Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 0–4000 psi with overpressure protection |
| UV-Vis Detection Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P1 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A2 / 2DMax1100P2 |
| Flow Range | 0–200 mL/min (customizable up to higher rates) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-VIS Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P2 only) | 160 positions, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 2DMax1100A3 / 2DMax1100P3 |
| Price | Upon Request |
| Pump Flow Range | 0–200 mL/min (customizable higher flow available) |
| Maximum Pressure | 4000 psi with overpressure protection |
| UV-Vis Detector Wavelength Range | 190–850 nm (quad-wavelength simultaneous detection), wavelength accuracy: ±0.2 nm |
| Light Source | Deuterium lamp + Tungsten lamp |
| Autosampler Capacity | 144 vials (sealed vial design with needle wash function) |
| Fraction Collector (2DMax1100P3 only) | 160-tube rack, 15 mm tube diameter |
| Software Platform | Windows 7/10 (64-bit) |
| Communication Interface | Ethernet |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A1 / 2DMax1500P1 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Sealing Force | Up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.3 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi (A1) / 0–4,000 psi (P1) |
| UV-VIS Detection | Four simultaneous wavelengths, 190–900 nm |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200-line grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitation Loop | 20 µL (A1) / 2 mL (P1) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 2DMax1500A2 / 2DMax1500P2 |
| TLC Plate Max Size | 200 × 200 mm |
| Laser Power | 5 mW |
| Seal Force | up to 500 N |
| Solvent Flow Rate (Extraction) | 0.05–0.5 mL/min |
| Extraction Probe Options | Ø4 mm, Ø5 mm circular |
| HPLC Flow Range | 0–100 mL/min (customizable) |
| Pressure Range | 0–10,000 psi |
| UV-VIS Detection Wavelength Range | 190–900 nm (quad-wavelength simultaneous detection) |
| Wavelength Accuracy | ±0.2 nm |
| Monochromator | 1200 lines/mm grating |
| Light Source | Deuterium–Tungsten dual lamp |
| Quantitative Loop | 20 µL (customizable) |
| Autosampler | Integrated |
| Fraction Collector Capacity | 160 positions |
| Gradient Composition Range | 0–100% linear A:B |
| Software Platform | Windows 7/8/10 |
| Communication Interface | Ethernet |
| Power Supply | 110–220 V AC, 500 W |
| Gas Supply | Nitrogen or compressed air |
| [Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200E |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 144 × 2 mL vials |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | 10–80 °C |
| UV-Vis Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz] |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200F1 |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20–100 °C |
| Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200F2 |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20–100 °C |
| Wavelength Range (Fluorescence Detector) | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200V |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| UV-Vis Wavelength Range | 190–850 nm |
| Data Acquisition Rate | 100 Hz |