Chemical Analysis Instruments
Filter
Showing 2221–2250 of 10669 results
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | -20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-210-P |
| Instrument Principle | Electrolytic (P₂O₅ sensor) |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm, 0–100 ppm, 0–1,000 ppm, 0–2,500 ppm (auto/manual range switching) |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Alarm Outputs | Configurable high/low limit relays |
| Analog Output | 4–20 mA (user-configurable) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Enclosure Rating | IP20 |
| Dimensions | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Weight | ~6 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1 ppm |
| Repeatability | ±0.1 ppm |
| Range | 0–10 / 100 / 1,000 / 2,500 ppm (Auto-ranging) |
| Sensitivity | ±0.1% of full scale |
| Display | Backlit LCD with multilingual interface (including English, German, French, Spanish, Chinese) |
| Alarm Output | 1 relay (SPDT) |
| Analog Output | 4–20 mA or 0–10 V (user-configurable) |
| Power Supply | Rechargeable NiMH battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-Ex |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -10 °C to 50 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Measurement Range | 0–10 / 100 / 1,000 / 2,500 ppmv H₂O (auto-ranging) |
| Display | Backlit LCD |
| Output | 4–20 mA or 0–10 V analog + 1 relay alarm |
| Power | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm |
| Weight | ~6 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P-EX |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 ppm(v/v) |
| Repeatability | ±1 ppm(v/v) |
| Range | 0–10 / 100 / 1000 / 2500 ppm(v/v) (Auto-ranging) |
| Sensitivity | 0.1% of full scale |
| Display | Backlit LCD with multilingual interface (including English, German, French, Spanish, Chinese) |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 relay outputs |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Environmental Operating Range | 5–65 °C |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Dimensions (Portable Variant) | 257 mm (W) × 160 mm (H) × 316 mm (D) |
| Brand | CMC (Himsy) |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-Ex |
| Type | Portable Dew Point Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | 5–150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto/manual range switching) |
| Sensitivity | ±0.1% of full scale |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Alarm Outputs | High/Low configurable relay outputs |
| Analog Output | 0/4–20 mA (user-configurable) |
| Intrinsic Safety | Integrated Zener barrier |
| Power Supply | Rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Power Consumption | 8 W |
| Ambient Operating Temperature | −10 to +50 °C |
| Enclosure Rating | IP20 |
| Dimensions | 363 × 115 × 377 mm (W × H × D) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMA-210-P-IP54 |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | +5 °C to +150 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Ranges | 0–10 ppm / 0–100 ppm / 0–1000 ppm / 0–2500 ppm (auto-ranging or manual selection) |
| Response Time | <1 s |
| Sample Flow Rate | 100 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including English) |
| Output | 0/4–20 mA (configurable) |
| Alarm Outputs | High/Low limit relays (user-definable thresholds) |
| Power Supply | Internal rechargeable Li-ion battery or 80–230 VAC, 50–60 Hz |
| Enclosure | Portable aluminum-framed case, IP54 rated |
| Cable Length | Standard 3 m, optional up to 300 m |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P-ZB |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −5 to 50 °C |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.01 % of full scale |
| Measurement Range | 0–10 / 100 / 1000 / 2500 ppmᵥ (auto-ranging) |
| Sensitivity | 0.1 % of full scale |
| Response Time (T₉₀) | < 1 s |
| T₅₀ Response | < 8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| Ambient Temperature | 5–65 °C |
| Display | Multifunctional High-Resolution LCD |
| Analog Output | 4–20 mA |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Dimensions (Portable Version) | 363 mm (W) × 115 mm (H) × 377 mm (D) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMA-210-P-ZB |
| Product Type | Portable Dew Point Analyzer |
| Measurement Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | -20 °C to +50 °C |
| Accuracy | ±1 ppmv |
| Repeatability | ±1 ppmv |
| Range | 0–10 / 100 / 1000 / 2500 ppmv (Auto-ranging) |
| Full-Scale Accuracy | ±1% FS |
| Sensitivity | 0.1% FS |
| Display | Backlit LCD |
| Analog Output | 4–20 mA or 0–10 V |
| Alarm Outputs | 2 Relay Outputs |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Sample Temperature | 5–150 °C |
| T₅₀ Response Time | <8 s |
| Total Response Time | <1 s |
| Ambient Operating Temperature | 5–65 °C |
| Standard Cable Length | 3 m (up to 300 m optional) |
| Dimensions (Desktop) | 257 mm (W) × 160 mm (H) × 316 mm (D) |
| Brand | CMC (HimSi) |
|---|---|
| Origin | Germany |
| Model | TMA-404 |
| Type | In-line Dew Point / Moisture Analyzer |
| Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature | 5–50 °C |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.1% of full scale |
| Measurement Range | 0–1 / 10 / 100 / 1000 ppmᵥ (auto/manual range switching) |
| Response Time (T₉₀) | <1 s |
| T₅₀ Response | <8 s |
| Sample Flow Rate | 20 NL/h |
| Recommended Sample Pressure | 0.1–0.5 barg |
| Display | Touchscreen with multilingual UI (including Chinese) |
| Analog Output | 0/4–20 mA (configurable) |
| Alarm Outputs | 2 relay outputs |
| Power Supply | 80–230 VAC, 50–60 Hz |
| Enclosure Options | Rack-mount (482 × 133 × 350 mm), Wall-mount (300 × 260 × 280 mm), Bench-top (257 × 160 × 316 mm) |
| Weight | ~6 kg |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-100 |
| Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Flow Rate | 100 NL/h |
| Sample Gas Temperature Range | 5–50 °C |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Electrode Substrate | Hastelloy |
| Sensor Cell Housing | Borosilicate Glass |
| Sealing Material | FEP |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-100-P |
| Type | Portable Dew Point Meter |
| Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Gas Flow Rate | 100 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Measurement Cell Material | Hastelloy |
| Housing/Carrier Material | PEEK |
| Seal Material | FEP |
| Gas Inlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-20 |
| Type | Portable Dew Point Analyzer |
| Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Measuring Cell Material | Hastelloy |
| Electrode Material | Platinum |
| Substrate | Glass |
| Seal Material | FEP |
| Sample Gas Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-style compression fitting, Hastelloy |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-H-P-20-F |
| Type | Online Dew Point Analyzer |
| Principle | Electrolytic (P2O5) Sensor Technology |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sample Gas Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Electrode Material | Platinum |
| Measurement Cell Material | Hastelloy |
| Sensor Substrate | Borosilicate Glass |
| Seal Material | FEP (Fluorinated Ethylene Propylene) |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible compression fitting, Hastelloy C-276 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TMS-SS-P-20 |
| Product Type | In-line Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | -20 to +50 °C |
| Accuracy | ±1 ppmv |
| Repeatability | ±1 ppmv |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20 |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | 5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Seal Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure | 0.1–0.5 barg |
| Gas Inlet Fitting | 6 mm Swagelok®-style stainless steel compression fitting |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | TMS-SS-P-20-F |
| Product Type | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5) Method |
| Operating Temperature | +5 °C to +50 °C |
| Accuracy | ±1% of reading |
| Sensor Cell Material | Stainless Steel |
| Electrode Material | Platinum |
| Substrate | Glass |
| Sealing Ring Material | Viton |
| Sample Gas Temperature Range | 5–50 °C |
| Flow Rate | 20 NL/h |
| Operating Pressure Range | 0.1–0.5 barg |
| Gas Inlet/Outlet Fitting | 6 mm Swagelok®-compatible stainless steel compression fitting |
| Brand | CMC |
|---|---|
| Origin | Germany |
| Model | CMC-TM-H2O System |
| Instrument Principle | Phosphorus Pentoxide (P₂O₅) Electrolytic Method |
| Operating Temperature Range | −20 °C to +80 °C |
| Accuracy | ±0.2 °C dew point equivalent |
| Repeatability | ±0.1 °C dew point equivalent |
| Sample Flow Rate | 20 NL/h or 100 NL/h |
| Operating Pressure | 0.1–1.5 barg |
| Sensor Material Options | Stainless Steel, Monel 400, Hastelloy, Glass, PFA |
| Electrode Material | Platinum or Rhodium |
| Sealing Materials | Viton, FEP, or FFKM |
| Electrical Connector | LEMO waterproof |
| Enclosure Rating | IP20 (benchtop/rack), IP65 (wall-mount) |
| Power Supply | 80–230 VAC, 50/60 Hz |
| Power Consumption | 8 W |
| Dimensions (Analyzer) | 363 × 115 × 377 mm (portable), 482 × 133 × 350 mm (19″ rack), 300 × 260 × 280 mm (wall-mount), 257 × 160 × 316 mm (desktop) |
| Weight (Analyzer) | ~6 kg |
| Probe Dimensions | Ø43 × 120 mm |
| Probe Weight | ~300 g |
| Display | Backlit LCD |
| Output Signals | 4–20 mA / 0–20 mA / 0–10 V (user-configurable) |
| Digital Interface | RS232 |
| Relay Outputs | 2 alarm relays (230 VAC / 1 A), 5 range-indication relays |
| Input | 5 external relay contacts for range switching |
| Calibration | Automatic zero and span calibration at power-on |
| Response Time (T₅₀) | <8 s |
| Measurement Range (with TMA-202/204/210) | 0–10 / 100 / 1000 / 2500 ppmᵥ |
| Measurement Range (with TMA-404) | 0–1 / 10 / 100 / 1000 ppmᵥ |
| Environmental Operating Temp. | −10 °C to +50 °C |
| Sample Gas Temp. | +5 °C to +150 °C (recommended ≤50 °C |
| Ambient Temp. (Probe) | +5 °C to +65 °C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CMC-TW-H2O |
| Price Range | USD 14,000 – 28,000 |
| Product Type | Online Dew Point Analyzer |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Operating Temperature | −20 °C to +50 °C |
| Accuracy | ±1 ppmv H₂O (in dry gas matrix) |
| Repeatability | ±1 ppmv H₂O |
| Sample Flow Rate | 20 NL/h (nominal) |
| Pressure Regulation | Dual-stage stainless steel pressure regulators (1.0 MPa inlet → 0.1 MPa sensor inlet) |
| Filtration | 320TP fully sealed PTFE membrane filter (0.1 µm pore size) |
| Drainage Architecture | Dual three-way valve + precision needle valve purge system for liquid water removal |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CMS5000 |
| Price Range | USD 42,000 – 70,000 |
| Application Field | Environmental Monitoring |
| Temperature Control Range | Not Applicable (Fixed-temperature operation) |
| Heating Rate | Not Applicable |
| Cooling Rate | Not Applicable |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (PRC) |
| Model | Co Foil |
| Price Range | USD 0.15–1,500.00 (per piece, volume-dependent) |
| Thickness | 0.01–1.0 mm |
| Packaging | Vacuum-sealed in Class 100 cleanroom bags, stored and shipped under Class 1000 cleanroom conditions |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 83057-02 |
| Price | Upon Request |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | AutoHS 128 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Ambient to 180 °C |
| Injection Valve Temperature Range | 35–210 °C (same as needle temperature) |
| Temperature Control Accuracy | ±1.0 °C |
| Injection Volume Control | Time-based sampling (adjustable via dwell time) |
| Sample Tray Capacity | 128 positions |
| Vial Format | 20 mL standard headspace vials |
| Operating Modes | Gas Purge Mode, Constant Mode, Time-Gradient Mode, Multiple Headspace Extraction (MHE) Mode |
| Optional Feature | Vial Agitation Module |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AutoHS 20 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 180 °C |
| Valve & Transfer Line Temperature Control Range | 35 °C to 210 °C (isothermal with needle temperature) |
| Injection Mode | Time-based quantitative sampling (no fixed loop volume) |
| Sample Vial Capacity | 20 positions |
| Vial Specification | 20 mL standard crimp-top vials |
| Optional Feature | Programmable vial agitation module |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 40 positions |
| Vial Size | 20 mL |
| Vial Heating Range | Ambient to 180 °C |
| Valve & Needle Temperature Control Range | 35–210 °C |
| Injection Mode | Time-based quantitative sampling (no fixed loop volume) |
| Operating Modes | Gas Purge Mode, Constant Mode, Time-Gradient Mode, Multiple Headspace Extraction (MHE) Mode |
| EPC Integration | Yes, compatible with all major GC/GC-MS platforms |
| Optional Feature | Mechanical Vial Agitation (Shaking) |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 40 positions |
| Vial Size | 20 mL |
| Oven Temperature Range | Ambient to 180 °C |
| Valve & Needle Temperature Range | 35–210 °C |
| Sampling Mechanism | Time-based quantitative injection (no fixed loop volume) |
| Method Storage | 10 user-defined methods |
| Electronic Pressure Control (EPC) | Yes |
| Compliance | Designed for ASTM D3699, ISO 11843-2, USP <467>, and EPA Method 502.2 / 524.2 workflows |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AutoS 50A |
| Instrument Type | Dual-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automatic |
| Primary Desorption Temp Range | 50–400 °C |
| Secondary Desorption (Cold Trap) Temp Range | −40 to 400 °C |
| Valve & Transfer Line Temp Range | 50–300 °C |
| Cold Trap Temp Control Accuracy | < ±0.1 °C |
| Spike Recovery Rate | 99.5% |
| Sample Tube Capacity | 50 positions |
| Liquid Standard Positions | 16 |
| Mass Flow Controller Range | 0–500 mL/min |
| Flow Control Accuracy | ≤ 0.1 mL/min |
| Max Operating Pressure | ≥ 1.0 MPa |
| Applicable Concentration Range | ppt to ppm |
| Liquid Heating Zone Temp Range | Ambient to 300 °C |
| Temp Stability | ≤ ±1.0 °C |
| Brand | ColinTech (Chengdu Colin Analytical Instrument Co., Ltd.) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | AutoTD 20A |
| Instrument Type | Two-stage thermal desorber |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | 50–400 °C |
| Secondary Desorption (Cold Trap) Temperature Range | −40 to 400 °C |
| Valve & Transfer Line Temperature Range | 50–300 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | > 99.5% |
| Sample Capacity | 20 positions |
| Dual-Stage Split Flow Capability | Enables quantitative analysis across concentration ranges from ng to µg per analyte |
| Method Storage | Up to 10 user-defined methods |
| GC/GC-MS Compatibility | Universal interface for all major gas chromatography and mass spectrometry platforms |
| Brand | ColinTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AutoTD 50S |
| Instrument Type | Single-Stage Thermal Desorber |
| Desorption Temperature Range | 50–400 °C |
| Cold Trap Temperature | Not Applicable (Single-Stage Design) |
| Desorption Recovery Rate | ≥90% |
| Sample Capacity | 50 Positions |
| Brand | ColinTech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AutoTD A |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | 50–400 °C |
| Secondary Desorption Temperature Range | −40–400 °C |
| Valve Injection Zone Temperature Range | 50–300 °C |
| Transfer Line Temperature Range | 50–300 °C |
| Cryo-Trap Temperature Range | −40–400 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | 99.5% |
| Sample Capacity | 50 positions |
| Method Storage | 10 user-defined methods |
| Sample Recovery Function | Yes (≥90% recovery efficiency) |
| Leak Test & Moisture Purge | Automatic |
| Cap Handling | Automated cap removal and resealing |
| Optional Accessories | Electronic Pressure Control (EPC), Electronic Flow Control (EFC) |