| Brand | PIKE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 16x-xxxx |
| Price | USD 1,400 (approx.) |
| Brand | Pine Instruments (Pine Test Equipment, Inc.) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AFMSRCE / MSR |
| Rotation Speed Range | 0–10,990 rpm |
| Motor Power | 20 W |
| Speed Display Accuracy | ±1% |
| Control Architecture | Separated Motor & Controller Units |
| Electrical Protection | Integrated Surge and Voltage Instability Protection |
| Interface | Analog Input/Output (0–10 V) for External Speed Command and Tachometer Signal Output |
| Electrode Compatibility | Standard RDE, RRDE, and Rotating Ring-Disk Electrode (RRDE) configurations |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-IR |
| Instrument Type | High-Temperature GPC System |
| Pump Flow Range | 1 mL/min |
| Maximum System Pressure | 1000 psi |
| Column Oven Temperature Range | Up to 250 °C |
| Detector Configuration | IR4 or IR5 MCT Infrared Detector (C–H selective) |
| Optional Detectors | Four-Capillary Viscometer, Multi-Angle Light Scattering (MALS), Refractive Index (RI) |
| Automation | 42-position Autosampler with Integrated Sample Dissolution, Online Filtration & Backflush, Nitrogen Deoxygenation, Flow Marker Injection |
| Software | GPC-One (Multi-Detector Synchronization, Real-Time Data Acquisition, Mark–Houwink Analysis, Branching Quantification) |
| Brand | Polytech |
|---|---|
| Origin | Anhui, China |
| Manufacturer | Yes |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Cold Vapor Atomic Fluorescence Spectrometry (CVAFS) |
| Detection Limit | ≤0.002 ng/L (methylmercury), ≤0.002 ng/L (ethylmercury), ≤0.03 ng/L (total mercury) |
| Repeatability | ≤2% RSD |
| Linear Range | 0–40 ng/L (methylmercury), 0–40 ng/L (ethylmercury), 0–400 ng/L (total mercury) |
| Sample Capacity | 96 positions |
| Dimensions | 1200 × 400 × 400 mm |
| Weight | 43 kg |
| Power Supply | 220 VAC, 50 Hz, 5 A |
| Analysis Throughput | 9 samples/hour (methylmercury), 5 samples/hour (alkylmercury) |
| Sample Volume | 25 mL or 40 mL (aqueous) |
| Optional Total Mercury Module | Yes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PoolDirect 9-in-1 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PoolDirect |
| Pricing | Available Upon Request |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Linear Ion Trap |
| Application Field | General-Purpose |
| Mass Range | m/z 50–1000 |
| Sensitivity | 0.5 ng/mL (for standard test compound under defined LC-MS conditions) |
| Resolution | ≤0.5 Da (FWHM at m/z 500) |
| Dimensions | 33.3 × 23.5 × 14.6 cm |
| Weight | 8.5 kg |
| Battery Life | Up to 2 hours (integrated Li-ion power supply) |
| Vacuum System | Dual-stage non-continuous atmospheric pressure interface (DAPI) with built-in turbomolecular pump |
| Analysis Time | <3 minutes from sample introduction to report-ready output |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 1600 |
| Price | Upon Request |
| Wavelength Range | 325–1100 nm |
| Wavelength Repeatability | ≤1 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.4% T |
| Optical System | Single-Beam with 1200 lines/mm Holographic Grating |
| Display | Large Backlit LCD (Wavelength Resolution: 1 nm) |
| Data Storage | Up to 100 calibration curves and 2000 measurement records |
| Interface | RS-232, USB flash drive support, Bluetooth 4.2 (for data export, mobile app sync, and optional thermal printer) |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | CF2000 |
| Maximum Rotational Speed | 6500 rpm |
| Separation Mechanism | Size-based and Density-based Fractionation |
| Application Focus | Nanomaterial Sizing, Branched vs. Linear Polymer Analysis in Aqueous and Organic Solvents |
| Instrument Type | Centrifugal Field Flow Fractionation System |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | EAF2000 |
| Instrument Type | Asymmetric Flow Field-Flow Fractionation (AF4) with Integrated Electric Field-Flow Fractionation (EF4) |
| Operating Solvent Compatibility | Aqueous only |
| Channel Configuration | Dual-field, orthogonal separation channel module |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | GF2000 GS |
| Separation Mode | Gravitational Sedimentation FFF |
| Core Technology | SPLITT (Split Flow Thin Cell Fractionation) |
| Channel Configuration | Horizontal, Membrane-Free, Stationary-Phase-Free |
| Applicable Sample States | Aqueous or Low-Viscosity Suspensions |
| Typical Particle Size Range | 10 nm – 100 µm (dependent on density contrast and flow conditions) |
| Max. Sample Concentration | ≤ 5% w/v (varies by particle density and dispersibility) |
| Flow Rate Range | 0.1–5.0 mL/min (per inlet) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | SC2000 |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–9.995 mL/min |
| Pump Pressure Limit | 40 MPa |
| RI Detector Drift | 1 × 10⁻⁷ RIU/h |
| RI Detector Cell Volume | 8 µL |
| UV Detector Wavelength Range | 190–800 nm |
| UV Detector Noise | ±0.3 × 10⁻⁵ AU |
| Column Oven Temperature Range | +5 °C to +90 °C |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | TF 2000 |
| Field Type | Thermal |
| Instrument Category | Field Flow Fractionation (FFF) |
| Regulatory Class | Imported Analytical Instrument for Macromolecular & Nanoparticle Characterization |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | FJ3003 |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Analog Input Channels | 2 (auto-ranging: ±0.2 V, ±2 V, ±20 V) |
| Input Impedance | >10 MΩ |
| Sampling Rate | 100 MS/s |
| Display & Measurement Resolution | 4 significant digits |
| Temperature Measurement Accuracy | ±0.01 °C |
| Temperature Control Range | 15 °C above ambient to 100 °C |
| Temperature Setpoint Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Output Actuation | Zero-crossing triggered thyristor |
| Control Output | 5-step power output (max. 300 W) |
| Electrical Isolation | Analog-to-digital and overvoltage protection integrated |
| Compliance | Designed for academic lab environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JH11X |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Potentiostatic Range | ±2 V |
| Current Range | ±2 mA / ±20 mA (dual-range) |
| Potential Resolution | 0.001 V |
| Current Resolution | 0.001 mA |
| Reference Electrode Input Impedance | ≥10¹² Ω |
| Cell Voltage Range | ±13 V |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 320 × 215 × 130 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PRE-2000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision | ≤0.2% RSD |
| Flow Reproducibility | ≤0.2% RSD |
| Maximum Pressure | 5000 psi |
| Wavelength Range | 190–800 nm (±1 nm) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤0.15 × 10⁻⁵ AU |
| Data Acquisition Rate | 100 Hz |
| Pump Configuration | Dual Isocratic or Gradient Capable |
| Gradient Composition Range | 0–100% B |
| Auto-Cleaning Pump Head | Integrated |
| Maintenance Interval | ≥6 months under continuous operation |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | 330XM |
| Heating Source | Halogen Lamp |
| Display | High-Contrast VFD Screen |
| Weighing System | Integrated 320XB Precision Electronic Balance |
| Sensor Technology | MFR Electromagnetic Force Restoration |
| Construction | Full Die-Cast Aluminum Housing |
| Calibration | External Calibration Mode |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ) |
| Regulatory Features | Real-Time Clock, Password Protection, Mechanical Safety Interlock |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | EM120-HR |
| Heating Source | Halogen Lamp |
| Display | Backlit LCD with Graphical Real-Time Moisture Trend Plot |
| Construction | Full Cast-Aluminum Housing |
| Calibration | Fully Automatic Smart Calibration System (SCS) |
| Compliance | Supports 3Q Validation (IQ/OQ/PQ), GxP-Compliant Real-Time Clock, Multi-Level User Access Control with Password Protection |
| Software Features | Built-in Automatic Repeatability Test (ART), Checkweighing, Statistical Analysis |
| Connectivity | Standard RS232 & USB |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM120 |
| Maximum Capacity | 124 g |
| Minimum Readability | 0.001 g |
| Moisture Resolution | 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Drying Time Range | 0.1–99.9 min |
| Termination Modes | Automatic, Semi-Automatic (Δdigit/sec or Δ%/sec), Fixed-Time |
| Data Output Interval | 0.1–10.0 min |
| Password Protection | Yes |
| Statistical Functions | Count, Mean, Max, Min, Standard Error |
| Interface | RS232 |
| Memory | 50 Method Programs, 999 Test Records |
| Preheating | 30–100 °C |
| Multi-Stage Heating | 3 programmable segments (temp + time per stage) |
| Boost Mode | 140% target temp for first 3 min |
| Firmware Update | Remote via network |
| Brand | Precisa |
|---|---|
| Origin | Switzerland |
| Model | XM60 |
| Maximum Capacity | 62 g |
| Minimum Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost Function (140% target temp for first 3 min) |
| Termination Modes | Automatic, Semi-Automatic (user-defined mass change per second), Timed (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Preset Methods | 5 |
| Security | Password Protection, Physical Lock Slot |
| Interface | RS232 |
| Firmware Update | Remote download via network |
| Brand | EXPECLIN / Puju Medical |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Domestic |
| Model | PreMed 7000 |
| Pricing | Available Upon Request |
| Brand | PREVAC |
|---|---|
| Origin | Poland |
| Model | HPPES |
| Pressure Range | 2×10⁻⁹ mbar – 50 mbar |
| Base Pressure (UHV mode) | ≤1×10⁻⁹ mbar (configuration-dependent) |
| Sample Temperature Range | 20 K (LHe/LN₂-cooled) to 1400 °C |
| Analyzer Type | High-Pressure Hemispherical Energy Analyzer (EA15-HP5 / EA15-HP50) |
| X-ray Sources | Dual-anode monochromated AlKα / AgLα and non-monochromated AlKα / MgKα |
| UV Source | Powered He(I)/He(II) discharge lamp |
| Ion Source | Broad-beam Ar⁺ for sputter depth profiling or surface cleaning |
| Neutralizer | Electron flood gun |
| Manipulator | Motorized or manual 4–6 axis, with precise angular and translational control |
| Load-Lock Chamber | Integrated, with linear transfer to analysis chamber |
| Vacuum System | Composite pumping stack including roughing pump, turbomolecular pump (TMP), titanium sublimation pump (TSP), and cryo-shielded ion pump |
| Software Platform | Spectrium (Tango-compatible, PLC-integrated) |
| Compliance | UHV/HPXPS/APXPS/UPS/ARPES/AES/EELS/ISS/IPES/LEIPS standards |
| Brand | PREVAC |
|---|---|
| Origin | Poland |
| Model | PES |
| Base Pressure | ≤1×10⁻¹¹ mbar |
| Analysis Chamber Diameter | Ø310 mm |
| Sample Temperature Range | 20 K (LHe) to 1400 °C |
| Sample Manipulator | 4–6-axis motorized |
| Energy Analyzer | Hemispherical EA15 UHV |
| X-ray Sources | Monochromated dual-anode (AlKα/AgLα) and non-monochromated dual-anode (AlKα/MgKα) |
| UV Source | Powered He-I (21.2 eV) and He-II (40.8 eV) lamps |
| Flood Gun | Electron flood source for charge neutralization |
| Ion Sources | Ar⁺ sputter gun and gas cluster ion beam (GCIB) for depth profiling/cleaning |
| Optional Add-ons | LEED, RGA, IPES/LEIPS, AES, EELS, ISS modules |
| Control Software | Spectrium (Tango-compliant, PLC-integrated) |
| Vacuum System | Composite pumping stack including roughing pump, turbomolecular pump (TMP), ion pump, and titanium sublimation pump (TSP) with LN₂ shroud |
| Brand | Pri-eco |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | EA-IRMS-SCAR |
| Pricing | Upon Request |
| 14C Measurement Precision | 1–1.5 pMC @ 10 min |
| Measured Isotopes | ¹³C, ¹⁴C, ¹⁵N |
| Resolution (Central Collector) | 80 |
| Brand | Pribolab |
|---|---|
| Origin | Shandong, China |
| Model | MDS-3100 |
| Temperature Range | Ambient +5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.01–9.999 mL/min |
| Reaction Coil Volume | 1 mL |
| Material Construction | PEEK fluidic path |
| Flow Accuracy | ≤0.5% |
| Flow RSD | ≤0.1% |
| Safety Features | Backflow prevention valve, overpressure protection (500 psi), overtemperature cutoff (150 °C), leak detection shutdown, inert gas pressurized reagent reservoir (optional) |
| Compliance | Designed for GLP/GMP-compliant HPLC workflows |
| Brand | Prin-Cen |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | ELSpe-2 |
| Pricing | Upon Request |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Autosampler Capacity | 120 positions × 2 mL vials |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | 616A, 636A |
| Rotation Speed Range | 50–10,000 rpm |
| Speed Accuracy | < ±1% |
| Speed Control | Analog voltage input (0–10 V DC, linear proportionality) |
| Motor Type | Solid-state servo-controlled permanent magnet DC motor |
| Power Supply | Bipolar, high-voltage DC |
| Compatibility | Integrates with standard potentiostats/galvanostats including PAR electrochemical workstations |
| Compliance | Designed for ASTM G102, ASTM G59, ISO 17475, and electrochemical kinetic studies per IUPAC recommendations |
| Application Domain | Electrocatalysis (HER, OER, HOR, ORR), mass-transport-controlled reaction analysis, reaction intermediate detection |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PAR STAT MC |
| Instrument Type | Electrochemical Workstation |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% of full scale |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| [Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PAR 273A |
| Maximum Output Voltage | >±100 V |
| Maximum Output Current | >±1.0 A |
| Slew Rate | 10 V/µs |
| Open-Loop Bandwidth (Unity Gain) | >2.5 MHz |
| Electrometer Input Impedance | >10¹² Ω |
| Input Bias Current | <20 pA at 25°C |
| Differential Input Range | ±10 V |
| Reference Input Range | ±11 V |
| Small-Signal Bandwidth | >8 MHz |
| Full-Signal Bandwidth | >400 kHz |
| IR Compensation Range | 2 Ω to 20 MΩ |
| Current Ranges | 1 A to 100 nA (8 decades) |
| Current Measurement Accuracy | 0.2% (10 µA–1 A), 0.5% (100 nA–1 µA) |
| Potentiostatic Control Resolution | 14-bit DAC, ±8 V range |
| Galvanostatic Control Resolution | 14-bit DAC, ±200% of full scale |
| Rise Time (High-Speed Mode) | <750 ns (no load), <3 µs (1 Ω, 1 A) |
| Noise | <25 µV rms (with external input) |
| Interfaces | RS-232C, IEEE-488 (GPIB) |
| Dimensions | 48 cm W × 30 cm H × 51 cm D |
| Weight | 31 kg |
| Power | 100–260 V AC, 50–60 Hz, max 350 W] |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PARSTAT 2273 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 pA to ±2 A (optional ±20 A) |
| Current Resolution | 1.2 fA |
| Current Accuracy | <0.4% of reading (for 20 µA–2 A range) |
| Potential Accuracy | ±0.2% of value ± 2 mV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (extendable) |
| Cell Voltage Compliance | ±100 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Input Impedance | >10¹³ Ω |
| Electrometer Bandwidth | >15 MHz (–3 dB) |
| Minimum Time Base | 20 µs |
| Minimum Potential Step | 2.5 µV |
| iR Compensation | Positive feedback (2 Ω to 2000 MΩ) |
| Interface | USB |
| Weight | 31 kg |
| Dimensions | 50.8 cm W × 47.6 cm H × 22.9 cm D |
| Power Supply | 90–260 V AC, 50–60 Hz, max. 600 W |