BrandChengyi
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJP-2C
Price RangeUSD 2,800 – 4,300 (FOB)
Polarographic Sensitivity<5×10⁻⁸ mol/L (Cd²⁺, Linear Sweep Polarography)
Resolution of Polarographic Peaks<32 mV
Tolerance to Pre-reduced Interferents>10,000:1
Repeatability Error<0.5%
Range Switching Error<0.5%
Current Range15 nA – 400 µA F.S., 23 programmable decades
Polarization Potential Range±3904 mV, minimum step 32 mV
Scan Rate250 mV/s
Scan Amplitude500 mV
Scan Period1 s – 1000 s
Power Supply100–240 VAC, 50/60 Hz
Weight15 kg
Display19″ LED LCD (1366×768), USB mouse & dual USB host ports (for firmware update & data export)
Parameter StorageUp to 5 user-defined methods
Onboard QuantificationStandard Comparison Method supported
ADC/DAC Resolution12-bit (1/4096 precision)
Embedded PlatformARM-based real-time control system
ComplianceDesigned for GLP-aligned laboratory workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSCChengyi
OriginSichuan, China
ModelQFS601
Measurement Range-80 to +20 °C dew point (≈ 0.5–23,632 µL/L H₂O)
Accuracy≤ ±1 °C
Response Time<30 s (63%), <60 s (90%) for rise at DP < -40 °C
Output Signals4–20 mA, RS232 or USB (user-specified)
Power SupplyAC 220 ± 22 V, 50–60 Hz / Internal rechargeable battery (DC)
Operating ConditionsGas Temp < +60 °C, Pressure < 2 MPa, Recommended Flow Rate: 200 mL/min
Dimensions260 × 170 × 300 mm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelZLS-23B / ZLS-24C
Minimum Detectable Leak Rate2 × 10⁻¹¹ Pa·m³/s
Pump TypeOil-Diffusion Vacuum System
Detection GasHelium (⁴He⁺)
Mass Separation PrincipleMagnetic Sector Mass Filter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi
OriginSichuan, China
ModelJP-2D
Polarographic Current Range15 nA–400 µA (F.S., 23 programmable ranges)
Polarization Potential Range±3904 mV (32 mV resolution)
Scan Rate50–1000 mV/s
Scan Amplitude50–1000 mV
Scan Period1–1000 s
Sensitivity<5×10⁻⁸ mol/L (Cd²⁺, linear sweep polarography)
Resolution<32 mV
Anti-Interference Ratio (pre-reduction substances)>10⁴:1
Repeatability Error<0.3%
Range-Switching Error<0.3%
ADC Precision18-bit
Power Supply100–240 VAC, 50/60 Hz
Power Consumption~30 W
Weight15 kg
InterfaceUSB 2.0
Integrated Control Unit19.5″ all-in-one industrial PC (optional external Windows PC support)
SoftwareJP-2D Polarographic Analysis Suite (Windows 7/8/10, 32/64-bit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi (SCChengyi)
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZLS-23B
PricingAvailable Upon Request
Minimum Detectable Leak Rate< 2 × 10⁻¹¹ Pa·m³/s
Warm-up Time~1 h
Response Time≤ 3 s
Maximum Operating Pressure in Mass Spectrometer Chamber1 × 10⁻² Pa
Leak Test PortKF25
Dimensions (L×W×H)950 × 600 × 570 mm
Weight~65 kg
Power SupplyAC 220 V, ~2 kW
Ambient Temperature Range+5 °C to +40 °C
Relative Humidity< 80 % RH
Electromagnetic EnvironmentLow-interference zone recommended
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi / scchengyi
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-made)
ModelZLS-24D/M
PricingAvailable Upon Request
Startup Time≤5 min
Minimum Detectable Leak Rate<1×10⁻¹¹ Pa·m³/s (Negative-Pressure Mode)
Response Time≤3 s
Maximum Operating Pressure in Mass Spectrometer Chamber1×10⁻² Pa
Maximum Allowable Test Port Pressure1000 Pa
Leak Test InterfaceKF25
Dimensions (L×W×H)640×550×980 mm
Weight~75 kg
Power Supply220 V ±10%, ~2 kW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi (scchengyi)
OriginSichuan, China
ModelCZD-1
Measurement RangepH 0.00–14.00
Accuracy±0.06 pH (pH measurement), ±0.2% (volumetric repeatability)
Resolution0.01 pH / 1 mV
Stability±0.01 pH per 3 h
Endpoint Setting Range0.00–14.00 pH or ±1400 mV
Control Sensitivity±0.1 pH / ±5 mV
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption10 W
Net Weight5 kg
Environmental Operating Conditions5–40 °C, ≤85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSichuan, China
Manufacturer TypeDistributor
Origin CategoryDomestic
ModelKLY-2
PricingUpon Request
Product TypePortable Dew Point Meter
Measurement Range–80 to +20 °C dew point (approx. 0.5–23,632 µL/L H₂O)
Accuracy≤±0.5 °C (at factory calibration)
Response Time<30 s (63%), <60 s (90%) for rise at DP < –40 °C
Output Signal4–20 mA analog
Operating Media ConditionsGas temperature < +60 °C, pressure < 2 MPa, flow rate 200 mL/min
Dimensions260 mm × 170 mm × 300 mm (W×H×D)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelJP-2E
PricingUpon Request
Polarographic Sensitivity<5×10⁻⁸ mol/L (Cd²⁺, Linear Sweep Voltammetry)
Polarographic Peak Resolution<32 mV
Anti-Interference Capability (Pre-reduced Species)>20,000:1
Repeatability Error<0.4%
Current Range15 nA–400 µA F.S., 23 programmable decades
Polarization Potential Range±4000 mV, minimum step: 2 mV
Scan Rate50–1600 mV/s
Scan Amplitude50–1600 mV
Scan Period2–22 s
Power SupplyAC 220 V ±10%, 50 Hz
Weight15 kg
InterfaceUSB 2.0 for PC connectivity
Software ModesLinear Sweep Voltammetry, Stripping Voltammetry (Anodic/Cathodic), Cyclic Voltammetry (Anodic/Cathodic), First/Second Derivative Voltammetry
Quantitative MethodsCalibration Curve (Linear & Quadratic Regression), Standard Addition, Standard Comparison
Electrode CompatibilityGlassy Carbon Electrode (GCE) interface with full Dropping Mercury Electrode (DME) functional equivalence
Data ExportNative CSV/Excel-compatible output, curve annotation, overlay, and statistical post-processing
Added to wishlistRemoved from wishlist 0
Add to compare
Brandscchengyi
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelUSI-1AB
Product TypeOnline Dew Point Moisture Analyzer
Measurement PrinciplePhosphorus Pentoxide (P₂O₅) Electrolytic Method
Operating Temperature5–40 °C (ambient)
Supply Gas Pressure<100 kPa
Accuracy±5% of reading
Repeatability<0.08 µL/L at sample moisture ≤260 µL/L
Range0–1000 µL/L (ppmv)
Response Time (t₆₃)≤3 min
Output Signals0–10 mV and 4–20 mA
Power SupplyAC 220 V ±10%, 50–60 Hz
Sample Flow Rate100 mL/min (measurement), 1 L/min (bypass)
Dimensions380 × 300 × 170 mm
Weight6.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
Brandscchengyi
OriginSichuan, China
ModelJP-06A
Current Measurement Range1×10⁻³ A to 1×10⁻⁹ A (F.S.)
Sensitivity5×10⁻⁸ mol/L for Cd²⁺ (Linear Sweep Polarography)
Potential Range−4000 mV to +4000 mV (min. step: 0.15 mV)
Scan Rate0.05–1 V/s
DME Drop Period1–1000 s
Resolution< 2.5 mV
Anti-Interference Ratio (for pre-reduced species)10⁴ : 1
Repeatability Error< 0.1 %
Range Switching Error< 0.1 %
ADC24-bit
DAC16-bit
Power Consumption< 10 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic Lab-Scale Dew Point Analyzer
ModelUSI-3
PricingAvailable Upon Request
Instrument PrincipleElectrolytic (Phosphorus Pentoxide Sensor)
Operating Temperature5–35 °C
Accuracy±3% of total water mass
Repeatability≤1% RSD
Measurement Range0.0000–99.999 mg H₂O
Power SupplyAC 220 ± 22 V, 50–60 Hz or DC 10–45 V (for integrated dryer unit)
Carrier GasUltra-Dry Nitrogen (<10 ppmv H₂O), Flow Rate: 70 ± 20 mL/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi (SCChengyi)
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZLS-26D/M
PriceUpon Request
Minimum Detectable Leak Rate< 5×10⁻¹² Pa·m³/s
Response Time≤ 3 s
Maximum Operating Pressure in Mass Spectrometer Chamber1×10⁻² Pa
Maximum Inlet Pressure at Test Port1000 Pa
Backpressure Test Duration Range5–30 s
Pump-Down & Startup Time≤ 5 min
Dimensions (W×D×H)640 × 550 × 980 mm
Weight~75 kg
Power Supply220 V ±10%, 50 Hz
Display12-inch Touchscreen LCD with Real-Time Leak Rate Plotting & Unit Conversion (Pa·m³/s, atm·cm³/s, mbar·L/s, Torr·L/s)
Data ManagementOnboard Storage, Print Export, GLP-Compliant Audit Trail (via V1.0 Control Software)
Detection PrincipleMagnetic Sector Helium Mass Spectrometry (m/z = 4) with Positive Ion Detection and Quadrupole-Assisted Peak Discrimination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi
ModelJP-303E
OriginSichuan, China
Sensitivity<2×10⁻⁸ mol/L (Cd²⁺, linear sweep polarography)
Peak Resolution<30 mV
Antioxidant Tolerance>20,000:1
Repeatability Error<0.1%
Range Switching Error<0.2% (≥1.5×10³ nA), <0.4% (≤1.0×10³ nA)
Potential Resolution2 mV
Current Resolution0.03% of full scale (conventional, 1st & 2nd derivative modes)
Current Range(6–4×10⁵) nA, 25 programmable ranges
Polarization Potential Range±4094 mV, min. step 2 mV
Scan Rate50–1000 mV/s, continuously adjustable
Scan Amplitude0–1600 mV, min. step 2 mV
Scan Duration1–1000 s
Power SupplyAC 220 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandChengyi
OriginSichuan, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJP-2E
Price RangeUSD 4,200 – 7,000
Sensitivity<5×10⁻⁸ mol/L (Cd²⁺, linear sweep polarography)
Resolution<32 mV
Anti-interference Ratio (pre-reduction substances)>20,000:1
Repeatability Error<0.4%
Range Switching Error<0.4%
Current Range15 nA – 400 µA F.S., 23 programmable ranges
Polarization Potential±4000 mV, min. step 2 mV
Scan Rate50–1000 mV/s
Scan Amplitude50–1000 mV
Cycle Time2–22 s
Power SupplyAC 220 V ±10%, 50 Hz
Weight~15 kg