| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | C2008 |
| Pricing | Upon Request |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM-6240BD / RM-6240CD |
| Interface | USB 2.0 |
| Max Sampling Rate | 1000 kHz (single channel) |
| Input Impedance | ≥100 MΩ (differential) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS |
| Frequency Response | DC–10 kHz |
| Input Range | 5 µV–500 mV |
| Sensitivity Ranges | Bioelectric: 20 µV/div–500 mV/div |
| Blood Pressure | 0.48–24 kPa/div or 3.6–180 mmHg/div |
| Hardware Filters | Low-pass: 3/10/30/100/500/1k/3k Hz, OFF |
| Time Constant | 0.001–5 s, DC |
| Stimulator Output | Voltage: 0–150 V (opt.), Current: 0–150 mA |
| Pulse Width/Delay/Interval | 0.1–1000 ms |
| Frequency | 1–3000 Hz |
| Calibrated Transducers | Tension: 0–50 g, Sensitivity: 100 mV/30 g (6 V DC) |
| Pressure | −10 to +40 kPa, Sensitivity: 25 mV/12 kPa (6 V DC) |
| Brand | Chengyi (SCChengyi) |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CQY-1 |
| Pricing | Available Upon Request |
| Brand | SCChengyi |
|---|---|
| Model | PHG-1 |
| Temperature Range | Ambient to 100°C |
| Max Heating Power | 350 W |
| Heating Time (Ambient → 38°C) | <10 min |
| Operating Voltage | AC 220 V, 50 Hz |
| Temperature Control Accuracy | ≤0.2°C |
| Display Resolution | 0.1°C |
| Dual Display | Actual & Set Temperature |
| Dual Preheating Reservoirs | 45 mL and 200 mL |
| Preheating Glass Tubes | Three 20 mL + One 60 mL Quartz Tubes |
| Leakage Protection | 10 mA Trip Current |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | MGS-1/4 |
| Price | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MSZ-1 |
| Pricing | Upon Request |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DSWY-1 |
| Pricing | Available Upon Request |
| Sensor Included | Yes |
| Brand | SCChengyi |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SQG-1 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 100°C |
| Max Heating Power | 350 W |
| Warm-up Time (Ambient → 38°C) | <10 min |
| Operating Voltage | AC 220 V, 50 Hz |
| Temperature Control Accuracy | ≤0.1°C |
| Display Resolution | 0.1°C |
| Dual Display | Actual & Set Temperature |
| Bath Capacity | 20 mL (±1 mL precision) |
| Preheating Rack | Holds five 20 mL glass tubes + accommodates ≥200 mL auxiliary reservoir |
| Modular Bath Design | Detachable for cleaning or replacement |
| External Circulation & Gas Supply Unit | Decoupled from bath chamber to eliminate pump-induced vibration |
| Adjustable Gas Flow Rate | Compatible with ambient air or externally supplied O₂ |
| Integrated Tissue Suspension Assembly | One-dimensional precision micrometer stage with synchronized transducer–tissue movement |
| Leakage Protection | 10 mA residual-current device |
| Waste Collection | Dedicated waste reservoir included |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DHX |
| Pricing | Upon Request |
| Tidal Volume Range | 1–50 mL / 1–150 mL / 1–300 mL / 1–500 mL (selectable) |
| Respiratory Rate | 1–199 breaths/min |
| I | E Ratio Options: 1:1, 1:2, 1:3, 2:1 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 400 × 140 × 280 mm |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MTS-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JTC-1 |
| Pricing | Upon Request |
| Output Voltage Range | 0–120 V AC (50 Hz), Continuously Adjustable |
| Output Current | ≥100 mA |
| Stimulation Modes | Single Pulse, Continuous Train, Externally Triggered Programmable Mode |
| Stimulation Duration | 0.2, 0.3, 0.4, 0.5, 0.6 s |
| Inter-Stimulus Interval (ISI) | Single Pulse, 1, 2, 5, 10 s |
| Trigger Sources | Internal Clock or External TTL-Compatible Signal (5–15 V) |
| Brand | SCChengyi |
|---|---|
| Model | XY-2 |
| Category | Animal Metabolism Detection System |
| Origin | Sichuan, China |
| Measurement Capabilities | Blood Pressure (Systolic/Diastolic), Peripheral Capillary Oxygen Saturation (SpO₂), Pulse Rate |
| Operating Modes | Manual, Automatic, Continuous Monitoring |
| SpO₂ Range | 0–99% |
| Pulse Rate Range | 0–255 bpm |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MYS-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MDS-1 |
| Pricing | Upon Request |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HSS-1B |
| Quotation | Upon Request |
| Temperature Control Range | Room Temp +10°C to 100°C |
| Temperature Stability | ±0.03°C |
| Heating Power | 1 kW |
| Circulation Pump Flow Rate | 6 L/min |
| Bath Tank Dimensions (L×W×H) | 330 × 200 × 180 mm |
| Bath Opening Dimensions | 190 × 160 mm |
| External Dimensions | 385 × 250 × 380 mm |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Bath Tank Material | Stainless Steel (304) |
| Bath Volume | 12 L |
| Analgesia Chamber Diameter | φ160 mm |
| Brand | Chengyi (scchengyi) |
|---|---|
| Origin | Sichuan, China |
| Model | RM6240E/EC |
| Channel Count | 4 (expandable to 8 or 16 via daisy-chaining) |
| A/D Resolution | 16-bit |
| Max Single-Channel Sampling Rate | 1,000 kHz |
| Min Sampling Rate | 0.01 Hz |
| Continuous 4-Channel Sampling Rate | 200 kHz |
| Input Impedance | ≥100 MΩ (differential), ≥50 MΩ (single-ended) |
| CMRR | ≥100 dB |
| Input Noise | ≤±1 µV RMS / ≤±3 µV P-P |
| Frequency Response | DC–20 kHz |
| Input Range | 5 µV–500 mV |
| Gain Settings | 10 µV/div–500 mV/div (bioelectric), 0.36–360 mmHg/div (blood pressure) |
| Hardware Filters | Low-pass (0.3 Hz–20 kHz, OFF), Time Constant (0.001 s–DC), 5+ order analog filtering |
| Stimulator Output | ±50 V max, ≤100 mA, programmable pulse modes (single, train, dual, incremental, timed), galvanically isolated |
| ECG Lead Support | Full 12-lead (I, II, III, aVR, aVL, aVF, V1–V6), software-switchable |
| Environmental Sensors | Integrated temperature, atmospheric pressure, and humidity measurement |
| Software Certifications | Certified software copyright (No. 2012SR137470), Sichuan Software Registration Certificate (Chuan DGY-2013-0154) |
| Data Export | MATLAB (.mat), SPSS (.sav), SAS (.sas7bdat), CSV |
| Compliance | Meets national safety standards for biomedical instrumentation (leakage current <3 mA) |