| Brand | SSI |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pump Type | Isocratic (Single-Solvent) High-Pressure Liquid Chromatography Pump |
| Maximum Pressure | 6000 psi (stainless steel head) / 5000 psi (PEEK head) |
| Flow Rate Range | 0.001–5 mL/min (standard configuration) |
| Flow Accuracy | ±2% |
| Flow Precision | 0.2% RSD |
| Pressure Monitoring | Integrated piezoresistive sensor with LED display |
| Pulse Damping | Low-volume diaphragm-type damper |
| Priming Mechanism | Internal high-speed cam-driven suction |
| Control Interface | Front-panel membrane keys + RS232 digital communication |
| Solvent Compatibility | Full compatibility with organic solvents (acetonitrile, methanol, THF, chlorinated solvents) and aqueous buffers |
| Wetted Materials | PEEK or 316L stainless steel (user-selectable) |
| Dimensions | 140 H × 254 W × 432 D mm |
| Weight | 11 kg |
| Power Supply | 115 V / 230 V, 50 / 60 Hz |
| Brand | SSI |
|---|---|
| Origin | USA |
| Model | SeriesIII |
| Pump Type | Isocratic (Single-Solvent) HPLC Pump |
| Construction | Stainless Steel Flow Path with Optional PEEK Fittings |
| Pressure Protection | Dual High/Low-Pressure Limit Shutdown |
| Control Interface | Front-Panel Keypad + LED Display + RS-232 Serial Port |
| Self-Cleaning Capability | Integrated Pump Head Flush Function + Quick-Release Drain Valve |
| Flow Path Design | Dual Check Valve Architecture |
| Seal Maintenance | Tool-Free Seal Ring Replacement |
| Operational Duty | Continuous Duty Rated for Stable Flow Delivery |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | GC Autosampler for Summa Canisters and Tedlar Bags |
| Model | GHD-5000 |
| Maximum Sample Capacity | Configurable (Standard: 1–12 canisters/bags) |
| Motion Control | Fully Automated Stepper-Motor-Driven Carousel |
| Repeat Injection Capability | Unlimited cycles with programmable sequence logic |
| Filtration Module | Integrated PTFE-membrane particulate filter (0.5 µm) |
| Carrier Gas Flow Range | 10–500 mL/min (N₂ or He, ±2% full-scale accuracy) |
| Sampling Line Material | SilcoNert®-coated stainless steel tubing |
| Backflow Prevention | Dual-stage check valve assembly |
| Housing Material | 316L stainless steel |
| Power Consumption | <45 W |
| Interface | RS-232 + Analog 0–10 V output |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | RI-500 Series |
| Detector Type | Refractive Index Detector (RID) |
| Compatible Systems | HPLC |
| Flow Cell Volume | 2.5–8 µL |
| Linear Range | 600–6000 µRIU |
| Noise | 2.5–5 nRIU (H₂O, 1.5 s response) |
| Drift | 0.2–2 µRIU/h |
| Response Time | 0.1–6 s (adjustable) |
| Temperature Control | 30–55 °C (dual-zone) |
| Max Backpressure | 50 kPa |
| Interface | LAN |
| Power | AC 100–240 V ±10%, 50/60 Hz, 150 VA |
| Dimensions | 260 W × 420 D × 165 H mm |
| Weight | 12.5 kg |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-3115 |
| Detection Principle | Bipolar Pulsed Electrode Conductivity Measurement |
| Measuring Range | 0.05–10,000 µS |
| Rise Time | 0–10 s |
| Cell Volume | 0.2 µL |
| Temperature Control Range | Ambient to 85 °C |
| Temperature Stability | ±0.01 °C |
| Signal Offset Adjustment | 0–20% of full scale |
| Digital Signal Smoothing | Enabled |
| Auto-zero Function | Supported |
| External Control Interface | Analog (0–10 V) and RS232 |
| Dimensions | 330 × 220 × 160 mm |
| Weight | ~8 kg |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-3210, S-3210S, S-3210DAD, S-3240, S-3240DAD |
| Wavelength Range | 190–720 nm |
| Spectral Bandwidth | 6 nm (2 nm per diode) |
| Noise | ±1.5 × 10⁻⁵ AU |
| Drift | 5 × 10⁻⁵ AU/h |
| Wavelength Accuracy | ±0.5 nm |
| Absorbance Range | 0.0005–2.0 AU (full scale, 8 selectable ranges) |
| Flow Cell | PEEK, 10 mm path length, 12 µL volume |
| Scan Speed | 0.1 s for full 190–720 nm spectrum |
| Analog Outputs | 4 channels (0–1.0 V, full-scale matched to absorbance range) |
| Interface | RS232 |
| Detector Type | Diode Array Detector (DAD) or Programmable Single-Channel UV-Vis |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S-3580 |
| Refractive Index Range | 1.00–1.75 RIU |
| Flow Rate Range | 0.2–3.0 mL/min (analytical/micro), 1.0–50 mL/min (semi-preparative) |
| Linear Range | 0–500, 0–1,000, or 0–20,000 µRIU |
| Noise Level | 5×10⁻⁹ to 10×10⁻⁸ RIU |
| Drift | <1 mV/h (at 1.0 mL/min, H₂O) |
| Cell Volume | 4 µL, 7 µL, or 9 µL |
| Cell Angle | 45° or 5° |
| Maximum Pressure Rating | 6 kg/cm² |
| Dead Volume | 6 µL, 24 µL, or 88/353 µL |
| Temperature Control | Ambient, 35–55 °C (1 °C increments) |
| Response Time Options | 0 s (real-time), 0.4 s, 0.8 s, 1.2 s |
| Output | ±1 V analog |
| Interface Frequency | 1 Hz or 10 Hz |
| Housing Dimensions | 220 × 350 × 155 mm |
| Weight | ~11 kg |
| Brand | Sykam |
|---|---|
| Origin | Germany |
| Model | S5200 |
| Instrument Type | HPLC Autosampler |
| Sample Capacity | 120 vials (2 × 60-position trays) |
| Standard Loop Volume | 20 µL (exchangeable) |
| Precision | RSD < 0.5% (fixed-volume mode) |
| Carryover | < 0.01% (low-pressure wash) |
| Programmable Wash Protocol | Yes |
| Control Interface | Analog signal or RS-232 digital |
| Dimensions | 415 × 300 × 445 mm |
| Weight | ~20 kg |
| Brand | Colintech |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TDC20 |
| Temperature Control Range | Ambient to 400 °C |
| Gas Flow Rate | 0–1000 mL/min |
| Tube Capacity | 20 tubes |
| Power Supply | 220 V AC, 3 A |
| Compliance | Designed for ASTM D6196, ISO 16017-1, and USP <621> thermal desorption system preparation protocols |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Model | AQUATek LVA |
| Sample Tray Capacity | 84 positions |
| Vial Size | 40 mL |
| Trap Temperature Range | Ambient to 350 °C |
| Sample Handling | Fully enclosed, refrigerated processing |
| Injection Loop Material | PEEK |
| Loop Volume Options | 5 mL, 10 mL, 20 mL, 25 mL |
| Internal Standard Storage | UV-protected amber vials with PEEK caps |
| System Cleaning | High-temperature water rinse of liquid pathways |
| Software | TekLink™ (integrated control for autosampler and purge-and-trap concentrator) |
| Regulatory Compliance | HJ 639–2012, HJ 686–2014, HJ 788–2016, HJ 806–2016, HJ 866–2017, HJ 893–2017, HJ 896–2017, GB/T 5750.8–2023 |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water & Soil Compatible |
| Sample Tray Capacity | 84 positions |
| Trap Temperature Range | Ambient to 350 °C |
| Brand | Tekmar |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water & Soil Compatible |
| Sample Tray Capacity | 84 positions |
| Trap Temperature Range | Ambient to 350 °C |
| Purge Volumes | 5 mL and 25 mL selectable |
| Flow Control | Mass Flow Controller (MFC) with programmable pressure/flow profiles |
| Cleaning | High-Temperature Water Rinse |
| Optional Features | Foam Monitoring/Elimination, Multi-Application Traps |
| Regulatory Compliance | ASTM D6866, EPA Methods 502.2, 524.2, 524.4, 624, 8260D, 8270E |
| Origin | USA |
|---|---|
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | Velocity XPT |
| Instrument Category | Water & Soil Integrated Purge and Trap System |
| Sample Tray Capacity | 72 positions |
| Injection Precision | RSD < 3% (typical, per ASTM D6059) |
| Trap Temperature Range | 180–300 °C |
| Sample Heating Temperature Range | –90 to 100 °C (cryogenic to ambient heating) |
| Vial Cooling Temperature Range | 4–10 °C |
| Brand | CETAC |
|---|---|
| Origin | Imported |
| Model | Aridus3 |
| Instrument Type | Multifunctional Autosampler for ICP-MS/ICP-OES |
| Construction Materials | PFA-only fluid path |
| Nebulizer Type | Low-flow, micro-consumption concentric nebulizer |
| Desolvation Technology | Heated hydrophobic membrane-based solvent removal |
| Waste Liquid Handling | Active vacuum-assisted back-purge |
| Gas Control | Integrated mass flow controllers (MFCs) for carrier and make-up gases |
| Software Interface | Aridus Link with remote temperature and flow setpoint control |
| Compliance | Compatible with GLP/GMP workflows |
| Safety | Full PFA compatibility enables direct analysis of HF-containing matrices (e.g., geological digests, semiconductor etchants) |
| Brand | CETAC |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | U5000AT+ |
| Instrument Type | Multifunctional Autosampler for ICP-OES and ICP-MS |
| Nebulization Principle | High-Efficiency Ultrasonic Nebulization (USN) |
| Detection Limit Improvement | 5–25× vs. Conventional Pneumatic Nebulizers |
| Compatibility | Integrated with Teledyne CETAC Apex Q, Apex HF, and standard ICP/OES/MS sample introduction systems |
| Energy Control | Closed-loop automatic RF power tuning for real-time droplet size stabilization |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tekmar 3100 |
| Instrument Type | Water & Soil Dual-Mode Purge and Trap System |
| Sample Tray Capacity | 84 positions |
| Injection Precision | RSD ≤ 10% |
| Trap Temperature Range | 180–300 °C |
| Purge Heater Temperature Range | Ambient to 90 °C |
| Sample Vial Chilling Temperature | 4–10 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AI/AS 1310 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity | 8-position (AI 1310) or 155-position (AS 1310) |
| Needle Wash Options | Single or dual-solvent (A/B/C/D, A+B, C+D) pre- and post-injection |
| Injection Modes | Minimum Needle Depth & Standard Needle Depth |
| Compatibility | Thermo Scientific GC systems (e.g., TRACE 1300/1600 series) |
| Upgrade Path | AI 1310 → AS 1310 |
| Optional Dual-Inlet Kit | AS 1310 Gemini Kit (enables simultaneous dual-port injection) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-AP |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 1152 positions (microtiter plate) / 81 vials (10 mL) |
| Injection Cycle Time | <30 s for 5 µL injection |
| Precision | RSD <0.3% |
| Fluidic Path | Full PEEK™ construction |
| Needle Design | Moving-needle architecture |
| Temperature Control | 4–60 °C sample tray cooling |
| Integrated Pre-injection Analysis | Conductivity & pH measurement |
| Automation Capabilities | Automated internal standard addition, on-line dilution, pre-column derivatization, matrix removal, analyte preconcentration, fraction collection, re-injection, and sample ejection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-DV |
| Instrument Category | Multifunctional Autosampler |
| Fluidic Path Material | PEEK™ |
| Compatible Systems | All Dionex ICS Ion Chromatography Systems |
| Sample Vial Capacity | 5.0 mL and 0.5 mL polymer vials |
| Valve Options | Optional 6-port or 10-port switching valves |
| Software Control | Thermo Scientific Chromeleon CDS (v7.3 or later) |
| Audit Trail & Electronic Signatures | Compliant with 21 CFR Part 11 |
| Dual-IC System Operation | Supported |
| Sample Overlap Injection | Enabled |
| Filtration Option | Available with filter cap accessory |
| Detection Limit Enhancement | Via automated on-line preconcentration and matrix elimination |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | AS-HV |
| Instrument Category | Multifunctional Autosampler |
| Sample Capacity | Up to 250 mL |
| Syringe/Pump Options | Syringe, Peristaltic, or Piston Pump |
| Rack Compatibility | 21-position (50 mL vials, 30 mm O.D.), 24-position (26 mL vials, 24 mm O.D.), 40-position (15 mL vials, 20 mm O.D.), 60-position (10 mL vials, 16 mm O.D.), or 21-position (60/40 mL ASE™ Collection Vials) |
| Fluid Path Material | All-PEEK™ |
| Loading Mode | Programmable “push” or “pull” |
| Arm Motion | High-speed, high-precision robotic positioning |
| Footprint | Compact benchtop design |
| Optional Integration | Dionex AutoPrep™ system, RFIC™-ESP platform, trace analysis cover |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | FPD Detector |
| Instrument Type | Flame Photometric Detector |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CAD |
| Instrument Type | Universal Chromatographic Detector |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Corona Veo |
| Instrument Type | Universal Chromatographic Detector |
| Flow Rate Range | 0.01–2.0 mL/min |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Sensitivity | Sub-nanogram |
| Linear Dynamic Range | >4 orders of magnitude |
| Compatibility | HPLC, UHPLC, microLC, capillary LC |
| Software Drivers | Chromeleon CDS, ChemStation, EZChrom, OpenLab, Empower 2/3 |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP-compliant data integrity workflows |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | SSL Inlet |
| Instrument Type | Gas Chromatography Injector |
| Compatibility | GC and GC-MS systems |
| Operating Modes | Split, Splitless, Cool-on-Column (COC), Large Volume Injection (LVI) |
| Thermal Management | Optimized heater profile with minimal thermal stress on septum |
| Septum Compatibility | Merlin Microseal™ (with adapter) |
| Column Compatibility | Capillary columns (50–530 µm ID) |
| Maintenance Design | Tool-free, top-access inlet body with removable liner and septum assembly |
| Oxygen-Free Operation | Certified inert flow path for high-fidelity transfer to mass spectrometers |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PTV Inlet |
| Instrument Type | Gas Chromatography (GC) Programmable Temperature Vaporizing Inlet |
| Temperature Range | Ambient +5 °C to 450 °C (standard) |
| Optional Cryogenic Cooling | Liquid Nitrogen to –100 °C or CO₂ to –50 °C |
| Max Ramp Rate | 870 °C/min |
| Programmable Temperature Steps | Up to 3 gradients |
| Compatible Autosamplers | Thermo AI/AS 1310 (requires syringe 365D1831), TriPlus 100LS & TriPlus RSH (requires syringe 365D0391) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Italy |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | TriPlus 500 |
| Instrument Category | Multifunctional Headspace Autosampler |
| Software Compliance | 21 CFR Part 11 |
| Validation Support | Built-in IQ/OQ/PQ and System Suitability Test Wizards |
| Sample Capacity | Expandable from 12 to 240 vials |
| Shaking Technology | Patented Quick Spin Shaking |
| Gas Path Design | Direct quantitative loop–GC column coupling with integrated leak detection and purge control |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | TriPlus RSH |
| Instrument Category | Gas Chromatography Autosampler |
| Sample Capacity | 972 × 2 mL vials + multiple 100 mL wash/waste bottles |
| Needle Exchange | Automatic Tool Change (ATC) |
| Minimum Sample Uptake | 5 µL (with bottom-sensing precision) |
| Liquid Injection Modes | Conventional, Fast (<100 ms), Sandwich |
| Headspace Capacity | 300 × 10/20 mL vials |
| SPME Automation | Full cycle (conditioning, extraction, desorption, cleaning) |
| Integrated Functions | Continuous dilution, spiking, derivatization, vortexing, barcode reading |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TriPlus 100 LS |
| Instrument Type | Gas Chromatography Autosampler |
| Price Range | USD 13,500 – 27,000 (FOB) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TriPlus 300 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TriPlus 500 Headspace Autosampler |
| Quotation | Upon Request |
| Sample Capacity | 12–240 vials (field-upgradable) |
| Sampling Technology | Valve-and-loop headspace sampling |
| Operating Modes | Standard, Multiple-Head-Space Extraction (MHE), Multiple-Head-Space Injection (MHI) |
| Software Integration | Thermo Chromeleon CDS, TraceFinder, XCalibur |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Compatible GC Systems | Thermo TRACE 1600 series (direct column coupling or transfer line), third-party GCs via TriPlus 100 LS / RSH / RSH SMART interfaces |
| Sample Path Design | Direct column connection option |
| Shaking Mechanism | Quick Spin Shaking (QSS) |
| Footprint Reduction | ~30% vs. conventional HS-GC systems |