| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ELSD-2000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Baseline Noise | ≤ 0.04 mV |
| Baseline Drift | ≤ 0.4 mV / 30 min |
| Minimum Detectable Mass | < 1 ng |
| Quantitative Range | 0.1 µg – 30 µg |
| Quantitative RSD | ≤ 2% |
| Evaporator Temp Range | Ambient to 130 °C (1 °C increments) |
| Nebulizer Temp Range | Ambient to 56 °C (1 °C increments) |
| Temperature Accuracy | ±1 °C |
| Carrier Gas | Clean Air or Nitrogen |
| Gas Pressure Range | 2–5 bar |
| Gas Pressure Resolution | 0.01 bar |
| Gas Flow Rate | 1–4 L/min |
| Flow Control Accuracy | ≤1% or 0.02 L/min |
| Mobile Phase Flow Compatibility | 0.01–3 mL/min |
| Analog Output | −1200 to +1200 mV |
| Gain Adjustment | 0.3–30 (continuous) |
| Data Acquisition Rate | 100 Hz (digital), 20 Hz (analog) |
| Interface | RS-232, RS-485, USB/LAN (TCP/HTTP), Programmable External Event I/O |
| Dimensions (W×H×D) | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ELSD-3300 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser Diode |
| Brand | Sanotac |
|---|---|
| Model | Omnitor ELSD |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Evaporative Light Scattering Detector |
| Wavelength | 650 nm semiconductor laser |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | 650 nm semiconductor laser diode |
| Dimensions | 26 × 19 × 46 cm |
| Weight | 10 kg |
| Power Supply | 85–264 VAC, 50 Hz |
| Evaporator Temperature Range | Ambient to 130 °C (1 °C increment) |
| Nebulizer Temperature Range | Ambient to 56 °C (1 °C increment) |
| Temperature Control Accuracy | ±1 °C |
| Carrier Gas | Clean compressed air or nitrogen |
| Gas Pressure Range | 2–5 bar (0.01 bar resolution) |
| Gas Flow Rate | 1–4 L/min (accuracy ≤1% or ±0.02 L/min) |
| Mobile Phase Flow Rate Compatibility | 0.01–3 mL/min |
| Baseline Noise | ≤0.03 mV |
| Baseline Drift | ≤0.3 mV / 30 min |
| Minimum Detectable Mass | <1 ng (e.g., cholesterol in methanol) |
| Quantitative Range | 0.1 µg–30 µg |
| Quantitative Repeatability (RSD₆) | ≤1.5% |
| Dynamic Range | 10⁴ (at fixed gain) |
| Analog Output Range | –1200 to +1200 mV |
| Gain Adjustment | Continuous, 0.3–30× |
| Output Offset | –1000 to +1000 mV |
| Sampling Rate | 100 Hz (digital), 20 Hz (analog) |
| Data Interfaces | RS-232, RS-485, USB, LAN (TCP/HTTP), programmable external event I/O |
| Software Compliance | FDA 21 CFR Part 11–compliant chromatography data system with audit trail |
| Method Storage | 10 methods × 25 parameters |
| Power Consumption | Low-power standby mode reduces nitrogen consumption by >50% |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omnitor |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Pilot1000 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Static Axial Compression System |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Pilot600 |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Pump Material | 316L Stainless Steel (PEEK optional) |
| Flow Rate Range | 0.01–600.00 mL/min (gradient mode) |
| Flow Accuracy | ±0.5% |
| Maximum Pressure | 10 MPa |
| Pressure Pulsation | ≤0.2 MPa |
| Gradient Types | Step, Linear, Real-time Adjustable |
| Minimum Gradient Increment | 1% |
| Detection Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | 0–2 AU |
| UV-Vis Light Source | Imported Deuterium + Tungsten Lamps |
| Sample Injection | Manual 10 mL loop (customizable loops available) |
| Injection Modes | Solid or Liquid Loading |
| Power Supply | 220 V ±10%, 50 Hz |
| Control Interface | Graphical UI via USB/RS-232 |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | QP-0010 |
| Instrument Type | Quaternary Pump |
| Maximum Pressure | 42 MPa |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Key | Brand: Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | QP0010 |
| Pump Type | Quaternary HPLC Pump |
| Max Pressure | 42 MPa |
| Flow Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pump Head Material Options | 316L Stainless Steel or Full PEEK |
| Drive Mechanism | Dual-Piston Series with Floating Piston Design |
| Flow Pulsation | ≤0.1 MPa |
| Display | 256×64 Dot Matrix Backlit LCD |
| Communication Interfaces | RS232/RS485/RS422, USB, Ethernet (wired), Optional Wireless |
| Control Protocols | Custom, Modbus RTU/ASCII, Profibus DP, Profinet |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 260 × 110 × 110 mm³ |
| Fluidic Connections | 1/16″ Standard Fittings |
| Wetted Materials | 316L SS, Sapphire, PTFE, Ceramic |
| Brand | Sanotac |
|---|---|
| Model | S-0150 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Isocratic Pump |
| Max. Operating Pressure | 50 MPa (7,250 psi) |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Flow Increment | 0.001 mL/min |
| Fluid Path Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Connection | 1/16″ Standard Fittings |
| Display | 256×64 Dot Matrix LCD with Backlight |
| Communication | RS232 & USB (standard), RS485/RS422 (optional) |
| Protocols | Sanotac Proprietary, Modbus RTU/ASCII |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | S0150 |
| Instrument Type | Isocratic Pump |
| Maximum Pressure | 50 MPa (7250 psi) |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Pumping Mechanism | Dual-Piston Series Configuration with Floating Piston Design |
| Wetted Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Tubing Connection | 1/16" Standard Fittings |
| Display | 256×64 Dot Matrix Backlit LCD |
| Communication Interfaces | RS232 & USB (standard), RS485/RS422 (optional) |
| Communication Protocols | Sanotac Proprietary Protocol, Modbus RTU/ASCII |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | S0160 |
| Instrument Type | Isocratic Pump |
| Max Pressure | 60 MPa |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | ±0.1% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Drive Mechanism | Dual-Piston Series Configuration with Floating Piston Design |
| Wetted Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Connection | 1/16″ Standard Fittings |
| Display | 256×64 Dot Matrix LCD with Backlight |
| Communication | RS232 & USB (Standard), RS485/RS422 (Optional), Modbus RTU/ASCII, Sanotac Proprietary Protocol |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions | 370 × 240 × 152 mm |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Domestic (China) |
| Model | SP1020 |
| Max. Operating Pressure | 20 MPa |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Increment | 0.01 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.2 MPa |
| Display | 256×64 dot-matrix backlit LCD |
| Control Interface | Front-panel keypad + RS232/USB open communication protocol compliant with ASTM E1381 and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | SP1110 |
| Instrument Type | Binary Pump |
| Max Pressure | 10 MPa |
| Flow Rate Range | 0.1–1000 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Brand | Sanotac |
|---|---|
| Model | SS1040 |
| Pump Type | Isocratic High-Pressure Solvent Delivery Pump |
| Max Operating Pressure | 40 MPa |
| Flow Rate Range | 0.01–100.00 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Pressure Pulsation | ≤0.1 MPa |
| Wetted Materials | 316L Stainless Steel, Sapphire, PTFE, Ceramic |
| Communication Interfaces | USB, RS232, RS485/422 (optional), Modbus RTU/ASCII |
| Power Supply | 85–264 VAC, 50 Hz |
| Power Consumption | 75 W |
| Dimensions | 370 × 240 × 152 mm |
| Weight | 8 kg |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | T6000 |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Model | UV-2001 |
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | UV-Vis Chromatographic Detector |
| Wavelength Range | 190–800 nm |
| Detection Mode | Simultaneous Dual-Wavelength Online Detection |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Flow Cell Pathlength | Adjustable from 1 to 5 mm |
| Flow Cell Inlet/Outlet | 1/16″ for Analytical & Semi-Preparative |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, Time Constant = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Absorbance Range | ≥3 AU |
| Time Constants | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Digital Zero Adjustment | Full-Scale Auto-Zero |
| Display | 256 × 64-dot Self-Illuminating LCD with Adjustable Backlight |
| Control Interface | Front-Panel Keypad + RS-232 / USB Computer Remote Control (Open Protocol) |
| Power Supply | 85–264 VAC, 50/60 Hz, 150 W |
| Brand | Sanotac |
|---|---|
| Model | UV1000 |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Ultraviolet-Visible Absorbance Detector (UVD) |
| Wavelength Range | 190–800 nm |
| Detection Modes | Simultaneous dual-wavelength detection across full range |
| Light Sources | Deuterium Lamp (190–400 nm) + Tungsten-Halogen Lamp (400–800 nm) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Flow Cell Pathlength | Adjustable from 1 to 5 mm |
| Flow Cell Inlet/Outlet | 1/16" for analytical & semi-preparative |
| Baseline Noise | ±0.5 × 10⁻⁵ AU at 254 nm, time constant = 1 s |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h at 254 nm |
| Absorbance Range | ≥3 AU |
| Time Constants | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Zero Adjustment | Digital full-scale auto-zero |
| Display | 320 × 240 pixel monochrome LCD, 4.7-inch active-matrix, adjustable backlight |
| Control Interface | Front-panel keypad + RS-232/USB digital interface with open communication protocol for third-party HPLC software integration |
| Power Supply | 85–264 VAC, 50/60 Hz, max. 150 W |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | UV1001 |
| Price Range | USD 1,400–2,800 (FOB) |
| Compatible Instrument | HPLC Systems |
| Instrument Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–700 nm |
| Detection Mode | Simultaneous Dual-Wavelength Online Detection |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Flow Cell Pathlength | Adjustable from 1 mm to 5 mm |
| Flow Cell Inlet/Outlet | 1/16" for Analytical & Semi-Prep |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Full-Scale Range | ≥3 AU |
| Time Constants | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Zero Adjustment | Digital Full-Scale Auto-Zero |
| Display | 256 × 64 Dot Matrix OLED, Self-Illuminating, Adjustable Backlight |
| Control Interface | Front Panel Keypad + RS-232 / USB Serial Communication (Open Protocol) |
| Power Supply | 85–264 VAC, 50/60 Hz, 150 W |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UV2000D |
| Instrument Type | UV-Vis Detector (UVD) |
| Wavelength Range | 190–800 nm |
| Detection Method | Dual-Beam, Full-Wavelength Scanning |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Flow Cell Path Length | Adjustable from 0.2 to 5 mm |
| Flow Cell Interface | 1/16″ for analytical/semi-preparative, 1/8″ for preparative |
| Baseline Noise | ±0.5 × 10⁻⁵ AU at 254 nm, TC = 1 s |
| Baseline Drift | 1.5 × 10⁻⁴ AU at 254 nm |
| Absorbance Range | ≥3 AU |
| Time Constant Options | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Digital Zero Adjustment | Full-scale auto-zero |
| Display | 320 × 240 pixel, 4.7-inch backlit LCD |
| Control Modes | Front-panel keypad + PC remote control via RS-232/USB |
| Communication Protocol | Open ASCII-based protocol |
| Data Acquisition | Onboard 24-bit ADC, analog-to-digital conversion at sensor interface |
| Power Supply | 85–264 VAC, 50/60 Hz, 150 W |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | UV2001 |
| Quotation Range | USD 1,400–2,800 (FOB) |
| Compatible Instrument | HPLC Systems |
| Instrument Type | UV-Vis Absorbance Detector |
| Wavelength Range | 190–800 nm |
| Detection Mode | Simultaneous dual-wavelength detection across full range |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Flow Cell Pathlength | Adjustable from 1 to 5 mm |
| Flow Cell Inlet/Outlet | 1/16″ for analytical & semi-preparative |
| Baseline Noise | ±0.5 × 10⁻⁵ AU at 254 nm (TC = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h at 254 nm |
| Linear Dynamic Range | ≥3 AU |
| Time Constants | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Digital Zero Adjustment | Full-scale auto-zero |
| Display | 320 × 240 pixel, 4.7-inch monochrome LCD with uniform backlighting |
| Control Interface | Front-panel keypad + RS-232/USB bidirectional communication with open protocol |
| Power Supply | 85–264 VAC, 50/60 Hz, 150 W |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | UV7001 |
| Instrument Type | UV-Vis Detector (UVD) |
| Wavelength Range | 190–800 nm |
| Detection Method | Dual-Beam |
| Light Source | Deuterium Lamp + Tungsten Lamp |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Flow Cell Pathlength | Adjustable (1–5 mm) |
| Maximum Flow Rate | 20 L/min |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Baseline Drift | 1.5 × 10⁻⁴ AU/h (254 nm) |
| Absorbance Range | 0–3 AU |
| Time Constants | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Display | 320 × 240 pixel, 4.7-inch backlit LCD |
| Control Interface | USB + RS-232 |
| Software Compliance | Fully compliant with CFDA GxP and FDA 21 CFR Part 11 |
| Power Supply | 85–264 VAC, 50 Hz |
| Brand | Sanotac |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Z6000 ELSD |
| Instrument Type | Evaporative Light Scattering Detector |
| Wavelength | 650 nm |
| Detection Mode | Low-Temperature Evaporation |
| Light Source | Semiconductor Laser |
| Brand | Sanotac |
|---|---|
| Model | Z9000 |
| Detector Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength | 650 nm |
| Detection Principle | Low-Temperature Evaporation Mode |
| Light Source | Semiconductor Laser |
| Temperature Control Accuracy | ±1 °C |
| Evaporator Temp Range | Ambient to 150 °C (1 °C increment) |
| Nebulizer Temp Range | Ambient to 60 °C (1 °C increment) |
| Gas Flow Range | 1–4 L/min (±1% or ±0.02 L/min) |
| Mobile Phase Flow Rate | 0.01–3 mL/min |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.2 mV/30 min |
| Quantitative Repeatability (RSD₆) | ≤1.5% |
| Minimum Detectable Mass | 0.5 ng |
| Typical Linear Quantitation Range | 0.1–30 μg |
| Analog Output | −1200 to +1200 mV with adjustable offset (−1000 to +1000 mV) and gain (0.3–30×) |
| Digital Output Rate | 20 Hz |
| Data Interface | RS-232, RS-485, USB, LAN (TCP/HTTP) |
| Software Compliance | FDA 21 CFR Part 11 with audit trail |
| Power Supply | 85–264 VAC, 50 Hz |
| Dimensions (W×H×D) | 260×190×460 mm |
| Weight | 10 kg |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 200 °C (1 °C increments) |
| Valve Temperature Control Range | 40–220 °C (±1 °C accuracy) |
| Sample Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL vials |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Capacity | 20 positions |
| Vial Size Compatibility | 10 mL or 20 mL |
| Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | 40–220 °C |
| Temperature Control Accuracy | ±1 °C |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.25 MPa (continuously adjustable) |
| Sampling Time | 0–30 min |
| Pressurization Time | 0–999 s |
| Injection Time | 0–999 s |
| Bake-out Time | 0–30 min |
| RSD | <1.0% (for 100 ppm ethanol in water) |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C (1 °C increment) |
| Valve Oven Temperature Range | 40–220 °C (±1 °C accuracy) |
| Quantitative Loop Volume | 1 mL |
| Sample Capacity | 20 positions |
| Compatible Vial Sizes | 10 mL or 20 mL |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | 40–220 °C (±1 °C) |
| Valve Heating Range | 40–220 °C (±1 °C) |
| Transfer Line Heating Range | 40–220 °C (±1 °C) |
| Temperature Stability | < ±0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressurization Time | 0–999 s |
| Sampling Time | 0–30 min |
| Injection Time | 0–999 s |
| Bake-out Time | 0–30 min |
| Minimum Time Resolution | 1 ms |
| Pressurization Pressure | 0–0.25 MPa (continuously adjustable) |
| Loop Volume | 1 mL (optional: 0.5 mL, 2 mL, 3 mL, 5 mL) |
| Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL (customizable up to 100 mL) |
| RSD | < 1.0% (measured with 100 ppm ethanol in water) |
| Purge Flow Rate | 0–100 mL/min (continuously adjustable) |
| Synchronization | GC trigger, data system start, external event input |
| Communication Interface | USB 2.0 |
| Display | 7-inch TFT LCD with Chinese/English UI |
| Power Supply | AC 220 V ± 10%, 50/60 Hz |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | AS-2902 |
| Pricing | Upon Request |
| Syringe Volumes | 1 µL, 5 µL, 10 µL, 25 µL, 50 µL, 100 µL, 250 µL, 500 µL |
| Sample Tray Capacity | 15-position and 110-position trays |
| Injection Repetition | 1–99 times per sample |
| Injection Interval | 0–65,535 s |
| Method Storage | 20 methods |
| Minimum Injection Volume | 0.1 µL |
| Maximum Injection Volume | 500 µL |
| Maximum Inlet Ports Supported | 2 |
| Maximum Injection Cycles per Sequence | 20 |
| Rinse Cycles | 1–15 |
| Viscosity Delay | 0–120 s |
| Pre-/Post-Injection Dwell Time | 0–300 s |
| PTV-Compatible Interval | 0–7200 s |
| Injection Speed Modes | Fast, Medium, Slow, User-Defined |
| Sampling Accuracy | ±0.01 µL |
| Injection Precision (RSD) | ≤0.2% |
| Brand | Sanpu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100 to 450 °C |
| Cryo-Focusing Trap Temp Range | −35 to Ambient °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cold Trap Cooling Method | Electronic Peltier Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |
| Valve Actuation | Motor-driven 6-port switching valve |
| Dimensions (L×W×H) | 350 × 450 × 510 mm |
| Weight | ~40 kg |
| Brand | Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Two-stage Thermal Desorber |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption Temp Range | 100–450 °C |
| Cryotrap Temp Range | −35 °C to Ambient |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Capacity | 20 positions |
| Cold Trap Cooling Method | Electronic Peltier Cooling |
| Temperature Control Accuracy | ±0.5 °C |
| RSD | ≤2.5% (for 0.05 μg benzene in methanol) |
| Sample Tube Format | 1/4″ OD × 3.5″ (ASTM D6196-compliant) |